Vous êtes sur la page 1sur 3

Proj. Name: 2 - Storey Resd'l. Bldg.

General Description:
Location: Lolita Village, Brgy. Caibaan, Tac. City Square Footing
Client: Pitao BL
Designer: Pitao BL
Date: 02/07/2008

SQUARE FOOTING DESIGN (WSD)

fc' : 3,000.00 psi Es = 200,000.00 Beam Dimension:


20.69 Mpa Ec = 4730√fc' 21,514.82 b d
fc = 9.31 n = Es/Ec 9.30 Beam # 1 250.00 400.00
fs : 40,000.00 psi k = n/(n+fs/fc) 0.239 Beam # 2 250.00 400.00
275.86 Mpa j = 1-k/3 0.920 Length Width
R = fckj/2 1.02 Slab 3.25 4.25
DEADLOAD: Thickness 0.13 meter
BEAM: 17.66 kilonewton Wall Ht. 2.6 meter
SLAB: 40.65 kilonewton Col. Dimen. 0.30 meter
WALL: 45.91 kilonewton Col.Height 7.25 meter
Column: 15.36 kilonewton Roofing 3.25 4.25
TOTAL: 119.58 kilonewton
ROOFING: 33.15 kilonewton
SIESMIC: 38.18 kilonewton
LIVELOAD:
2,400.00 33.15 kilonewton
TOTAL LOAD: P 335.09 kilonewton

Allow. Soil Bearing Pressure: 240.00 Kpa


34.78 Psi
Assume Weight of Footing = 6% (Load) 0.02 kilonewton

TOTAL AXIAL LOAD = 335.11 kilonewton

Footing Area Required: 0.001 sq.m.


L = 0.037 meter

Try : L = 1.20 meter Area = 1.44 sq.m.


0.450 0.30
NET UPWARD SOIL PRESSURE:p = 232.72 KN/sq.m.

MOMENT, M = 28.27 KN -m

d = sqrt(M/Rb) 4.80 mm.

Final Depth, d = 154.80 mm.

0.40 0.05
CHECK FOR BEAM SHEAR: 0.30 Critical section for Moment

V = pL 110.36 kilonewton

v = V/bd 0.00 Mpa 0.30 1.20

va =.09sqrt(fc') 0.41 Mpa

If va > v, Safe Na Bay!!!


Critical section for beam shear

CHECK FOR PUNCHING SHEAR:


d/2
Vp = 329.51 kilonewton
0.30 1.20
vp = Vp/Ap 0.001 Mpa
d/2
va = .17sqrt(fc') 0.77 Mpa

If va > vp, Safe Gyud na Kaayo Bay!!!


No. of Bars Bar Diameter Area, sq.mm
0.0 12 113.094

#DIV/0!
If Trial Area>Computed Area, It is Safe
m

1.20 m

for Moment