Académique Documents
Professionnel Documents
Culture Documents
• Apply water repellent according to JIC 122351 PRO 10000 (application SL ATR72 51-6001 (corrosion preventive actions and modifications status
of corrosion inhibiting compounds). report)
• Clean the area during maintenance operation. Moisture and any other
contamination must be removed. For prevention:
• Touch up the damaged existing protection when necessary
JIC 122351 PRO 10000 (application of corrosion inhibiting compounds) in
alternative to the JIC apply dinitrol AV30 or AV15 on internal box of the
3. PRODUCTION CORRECTIVE ACTION hatch door.
MOD. 1335 (ST1 C76; ST2 A)
• Modify overhead hatch 5. REPAIR ACTION UNDERTAKEN
52-22-00
Page 1
Doc. N° : DS/ET 531. 0129/91 REV. 3 Feb. 2005
C.P.C.I.C.F.
ATR42 :
ATR72 :
None
52-22-00
Page 2
Doc. N° : DS/ET 531. 0129/91 REV. 3 Feb. 2005
C.P.C.I.C.F.
DOORS – OVERHEAD HATCH DOOR
52-22-00
Page 3
Doc. N° : DS/ET 531. 0129/91 REV. 3 Feb. 2005
C.P.C.I.C.F.
DOORS – OVERHEAD HATCH DOOR
52-22-00
Page 4
Doc. N° : DS/ET 531. 0129/91 REV. 3 Feb. 2005
C.P.C.I.C.F.
DOORS – CARGO DOOR
1. NATURE AND REASON FOR CORROSION 4. IN SERVICE PREVENTIVE ACTION
The corrosion is located on lower internal box of door at frames and For information:
intercostals. There are also cases of corrosion on the inner door skin.
It is due to the water condensation trapping inside structure and by clogging SL ATR42 51-5002 (corrosion preventive actions and modifications status
of draining system. report)
SL ATR72 51-6001 (corrosion preventive actions and modifications status
report)
2. RECOMMENDATIONS
• Apply water repellent according to JIC 122351 PRO 10000 (application For prevention:
of corrosion inhibiting compounds).
JIC 122351 PRO 10000 (application of corrosion inhibiting compounds)
• Clean the cargo door drains holes.
JIC 122112 CLN 10010 (Cleaning checking of drain holes inside of the A/C)
• Embody SB as indicated in paragraph 4.
• For A/C operating in a severe environment reduce the interval of the 5. REPAIR ACTION UNDERTAKEN
inspection tasks.
• Mild corrosion treated by SRM 51-21-42.
3. PRODUCTION CORRECTIVE ACTION • For allowable damage and repairs refer to SRM 52-31-00 page block
300 and page block 400.
MOD. 0837 (ST1 D31; ST3 A; ST4 A; ST5 A) • Existing repair scheme for severe corrosion
• Add rain water collector Ø 13S523R0011 (Rib cargo door repair)
Ø 13S523R0016 (Frames, intercostal and skin repairs)
MOD. 4029 (ST1 D; ST3 D)
Ø 13S523R0039 (Intercostal repair of cargo door)
• Replace insulation blankets on cargo, passenger, emergency doors &
hatch. • Replace parts affected by severe corrosion and inform ATR
STRUCTURE ENGINEERING SUPPORT for data base collection.
52-31-00
Page 1
Doc. N° : DS/ET 531. 0129/91 REV. 3 Feb. 2005
C.P.C.I.C.F.
ATR42 :
ATR72 :
None
52-31-00
Page 2
Doc. N° : DS/ET 531. 0129/91 REV. 3 Feb. 2005
C.P.C.I.C.F.
DOORS – CARGO DOOR
52-31-00
Page 4
Doc. N° : DS/ET 531. 0129/91 REV. 3 Feb. 2005
C.P.C.I.C.F.
DOORS – AFT SERVICE DOOR
• For A/C operating in a severe environment reduce the interval of the SL ATR42 51-5002 (corrosion preventive actions and modifications status
inspection tasks. report)
SL ATR72 51-6001 (corrosion preventive actions and modifications status
3. PRODUCTION CORRECTIVE ACTION report)
• Modify drain system JIC 122351 PRO 10000 (application of corrosion inhibiting compounds)
JIC 122112 CLN 10010 (Cleaning checking of drain holes inside of the A/C)
MOD. 4029 (ST1 D; ST3 D)
• Replace insulation blankets on cargo, passenger, emergency doors &
hatch.
52-42-00
Page 1
Doc. N° : DS/ET 531. 0129/91 REV. 3 Feb. 2005
C.P.C.I.C.F.
5. REPAIR ACTION UNDERTAKEN 7. MAINTENANCE PROGRAM IMPROVEMENTS
• For allowable damage and repairs refer to SRM 52-42-00 page block
300 and page block 400.
• Existing repair scheme for severe corrosion
• Replace parts affected by severe corrosion and inform ATR
STRUCTURE ENGINEERING SUPPORT for data base collection.
ATR42 :
ATR72 :
52-42-00
Page 2
Doc. N° : DS/ET 531. 0129/91 REV. 3 Feb. 2005
C.P.C.I.C.F.
DOORS – AFT SERVICE DOOR
52-42-00
Page 4
Doc. N° : DS/ET 531. 0129/91 REV. 3 Feb. 2005
C.P.C.I.C.F.
DOORS – MLG DOORS
• It is strongly recommended to keep the area clean and to touch up the • Mild corrosion treated by SRM 51-21-42.
damaged existing protection when necessary. • Repair damage door edge as per SRM 52-81-00 page block 400
• Existing repair scheme for moderate and severe corrosion:
3. PRODUCTION CORRECTIVE ACTION
Ø 14S528R0043 (MLG door panel repair)
MOD. 1101 (ST1 D45; ST4 A; ST5 A) Ø 14S528R0044 (MLG door flange repair)
• Revising the chemical milling of the outer skin and bonding on the • For heavy corrosion not included in the SRM and for data base
inner skin at aft stop location. collection inform ATR STRUCTURE ENGINEERING SUPPORT.
52-81-00
Page 1
Doc. N° : DS/ET 531. 0129/91 REV. 3 Feb. 2005
C.P.C.I.C.F.
ATR72:
52-81-00
Page 2
Doc. N° : DS/ET 531. 0129/91 REV. 3 Feb. 2005
C.P.C.I.C.F.
DOORS – MLG DOORS
MLG. FAIRING
REF.
52-81-00
Page 4
Doc. N° : DS/ET 531. 0129/91 REV. 3 Feb. 2005