Vous êtes sur la page 1sur 2

SUMMARY OF SPECIFICATIONS

1.1 SCHEDULE OF EXTERIOR FINISHES

a. Concrete Walls - Plastered paint finish by “BOYSEN PAINTS”

1.2 SCHEDULE OF INTERIOR FINISHES:

a. Wooden Partition

- From 2” x 2” and 2” x 3” KD Lauan lumber, S4S for framings and


supports
- Smooth paint rollers on all wooden low wall partition surfaces and counters
- 6mmt clear glass panels with tint as per plan

b. Ceiling Works

- 600 x 1200 acoustic ceiling Armstrong Brand or approved equivalent. Submit


sample prior to purchase and installation.
- 1” x 1” oven baked, Ga. 26 Galvanized Iron on all suspended ceiling systems.
Provide ample supports and hangers.
- 4.5mmt Hardiflex on newly erected comfort rooms

c. Tile Works

- 400 x 400 glazed homogeneous granite tiles. Submit sample prior to installation
for approval.
- 300 x 300 glazed floorl tiles for new comfort rooms
- Provide ABC tiles grouts on all seams and joints

d. All Locksets and Finishing Hardwares

- For Locksets, use “Yale” or approved equal


- For Door Hinges, use “Hafele” or approved equal
- For Drawer Guides and Cabinet Hinges, use “Halefe” brand
- For Cabinet Handles/Pull, submit sample for architects approval

e. Painting Works

- Use “BOYSEN” Paints for all painting works unless otherwise


specified
- Use odorless paints for top coat by “ACE” Paints

f. Electrical Works

- Use 600 x 1200mm, 2-40watts FL on mirrorized fixed louvered lighting fixtures.


Submit sample for approval.
- Use 600 x 600, 2-20watts FL on mirrorized fixed louvered lighting fixtures.
Submit sample for approval.
- Use 40W FL box type lighting fixtures. Submit sample for approval
- Use 150mm diameter, sun-blasted, recessed type pin lights complete with
18watts CFL, warm-white. Submit sample for approval.

1.3 MISCELLANEOUS SPECIFICATIONS

a. Concrete Hollow Blocks

Machine made or equivalent with 350-psi non-load bearing.

b. Reinforcing Bars

Structural grade conforming to the latest edition of ASTM Designation A615-68


Grade 33.

c. Plumbing

a. For Water Lines, use PP pipes Fushiotherm or approved equal


b. For Vent Lines, use Emerald, Neltex or Atlanta brands (PVC Pipe)
c. For Waste Lines, use Emerald, Neltex or Altanta brands (PVC Pipe)
d. For Valves, use Crane, Kitz brands or approval equal
e. For Floor Drains, use Jaman brand

d. Electrical

a. For IMC on Service Entrance Metering Conduits and Circuit Breakers,


use G.E. or approved equal.
b. For all PVC Pipe Feeders, Branch Circuit and Auxiliary System, use
Emerald, Neltex or Atlanta Brands.
c. For wires and cables, use Phelpsdodge, Philflex, Duraflex or approved
equal.
d. For Panel Boards, Cabinets and Safety Switches, use G.E. or approved
equal.

e. Color Selection and Samples

a. All colors of finishes shall be approved by the Architect and Owner prior
to actual application.
b. Provide sample board of finishes for approval prior to installation.
c. All finish materials to submit sample at the site before purchase and
delivery.