SIMPLE CONNECTIONS
1. FULL DEPTH END PLATE- Flange side

1.2 Double sided


1.1 Single sided

Column Beam Beam-1 Column Beam-2

Design checks required are:

1. Check for bolts between end plate and column flange.


2. Check for combined shear and tensile capacity of bolt.
3. Check for bearing capacity of end plate
4. Check for block shear capacity of end plate
5. Check for weld between endplate and incoming beam web
6. Check for bending capacity of end plate.

Variation no: Rev date Description


Client : William Hare india Ltd Date : MAR-05
Project : Design Training Manual Calc'd by : PAK
Estimate no : Checked by : CSN
Contract no : C8860
Sheet no : Part1/2

Full depth end plate connected to column web

1.3 Single sided 1.4 Double sided

Beam-1 Beam-2
Beam
Column

Column

Design checks required are:

1. Check for bolt between column web and end plate


2. Check for combined shear and tension capacity of bolts
3. Check for weld between beam web and endplate
4. Check for bending capacity of end plate
5. Check for bearing capacity of end plate/column web(worst case)

Variation no: Rev date Description


Client : William Hare india Ltd Date : MAR-05
Project : Design Training Manual Calc'd by : PAK
Estimate no : Checked by : CSN
Contract no : C8860
Sheet no : Part1/3

2. CLEAT ANGLE CONNECTION


Flange Side

2.1 Single sided 2.2 Double Sided

BEAM-1 BEAM-2
BEAM-1 COLUMN
COLUMN

Design checks required are:

1. Check for shear capacity of bolt group between cleats and web of supported beam
2. Check for shear and bearing capacity of cleat connected to supported beam
3. Check for shear capacity of bolt group connecting cleats to supporting column
4. Check for shear and bearing capacity of cleats connected to supporting column
5. Check for Tension capacity of double angle web cleats
6. Check for Tension and bearing capacity of beam web

Variation no: Rev date Description


Client : William Hare india Ltd Date : MAR-05
Project : Design Training Manual Calc'd by : PAK
Estimate no : Checked by : CSN
Contract no : C8860
Sheet no : Part1/4

Web sided Cleats


2.3 Single sided 2.4 Double sided

COLUMN
COLUMN

BEAM-2
BEAM BEAM-2

Design checks required are:

1. Check for shear capacity of bolt group between cleats and web of supported beam
2. Check for shear and bearing capacity of cleat connected to supported beam
3. Check for shear and bending capacity of the supported beam
4. Check for shear capacity of bolt group connecting cleats to supporting column
5. Check for Local shear and bearing capacity of supporting column web
6. Check for shear and bearing capacity of cleats connected to supporting column
7. Check for Tension capacity of double angle web cleats
8. Check for Tension and bearing capacity of beam web

Variation no: Rev date Description


Client : William Hare india Ltd Date : MAR-05
Project : Design Training Manual Calc'd by : PAK
Estimate no : Checked by : CSN
Contract no : C8860
Sheet no : Part1/5

3. FIN PLATE CONNECTION

Flange side

3.1 Single Sided 3.2 Double sided

BEAM-1 BEAM-2
BEAM-1 COLUMN
COLUMN

Design checks required are:

1. Check for shear and tension capacity of bolts


2. Check for bearing of beam web / fin plate
3. Check for fin plate plain shear capacity
4. Check for fin plate block shear capacity
5. Check for shear and bending interaction of fin plate
6. Check for weld between fin plate and column flange

Variation no: Rev date Description


Client : William Hare india Ltd Date : MAR-05
Project : Design Training Manual Calc'd by : PAK
Estimate no : Checked by : CSN
Contract no : C8860
Sheet no : Part1/6

FIN PLATE CONNECTION- WEB SIDE

3.3 Single sided 3.4 Double sided

COLUMN

COLUMN BEAM-2 BEAM- 1


BEAM

Design checks required are:

1. Check for shear and tension capacity of bolt group


2. Check for bearing of beam web / fin plate(worst case)
3. Check for fin plate plain shear capacity
4. Check for fin plate block shear capacity
5. Check for shear and bending interaction of fin plate
6. Check for weld between fin plate and column web

Variation no: Rev date Description


Client : William Hare india Ltd Date : MAR-05
Project : Design Training Manual Calc'd by : PAK
Estimate no : Checked by : CSN
Contract no : C8860
Sheet no : Part1/7

4. Bracings:
4.1 Vertical Bracing Connected by web plates

20 min

Design checks required are :

1. Check for combined shear and tension capacity bolt group


2. Check for weld between beam web and end plate
3. Check for bending capacity of end plate
4. Check for bearing of flange/end plate
5. Check for weld between gusset plate and beam flange
6. Check for weld between gusset plate and end plate
7. Check for compression capacity of gusset plate
8. Check for gusset plate against minor axis bending
9. Check for bearing of bracing bar
10. Check for block shear capacity of brace bar / web cover plate(worst case)
11. Check for compression capacity of cover plates
12. Check for tension capacity of cover plates

Variation no: Rev date Description


Client : William Hare india Ltd Date : MAR-05
Project : Design Training Manual Calc'd by : PAK
Estimate no : Checked by : CSN
Contract no : C8860
Sheet no : Part1/8

4.2 Vertical Bracing connection-brace bar(UC/UB) connected by angles

Design checks required are :

1. Check for bolts between endplate and column flange


2. Check for combined shear and tension capacity of bolt group
3. Check for weld between beam web and end plate
4. Check for bending capacity of end plate
5. Check for bearing of flange/end plate
6. Check for weld between gusset plate and beam flange
7. Check for weld between gusset plate and end plate
8. Check for compression capacity of gusset plate
9. Check for gusset plate against minor axis bending
10. Check for bearing of bracing bar
11. Check for block shear capacity of brace bar / web cover plate
12. Check for compression capacity of cover plates
13. Check for tension capacity of cover plates
14. Check for shear capacity of the angles connecting the brace bar and gusset
15. Check for compression capacity of angles

Variation no: Rev date Description


Client : William Hare india Ltd Date : MAR-05
Project : Design Training Manual Calc'd by : PAK
Estimate no : Checked by : CSN
Contract no : C8860
Sheet no : Part1/9

4.3.Vertical Bracing connection-4(brace bar(UC/UB) connected by flange and web plates)

Design checks required are:

1. Check for shear capacity of bolts


2. Check for combined shear and tension capacity of bolts connecting the column flange and
end plate
3. Check for shear, tension and block shear capacities of the brace bar components
4. Check for shear, tension and block shear capacities for cover plates
5. Check for shear and block shear capacity of the gusset plate
6. Check for compression capacity of the gusset plate.
7. Check for endplate connecting beam and gusset for thickness.
8. Check for weld capacity of the gusset plate with beam flange
9. Check for weld capacity of the gusset plate with end plate

Variation no: Rev date Description


Client : William Hare india Ltd Date : MAR-05
Project : Design Training Manual Calc'd by : PAK
Estimate no : Checked by : CSN
Contract no : C8860
Sheet no : Part1/10

4.4 Vertical Bracing connection -brace bar (UC/UB) connected by flange stripping

20 min

Design checks required are :

1. Check for bolts between endplate and column flange


2. Check for combined shear and tension capacity of bolt group
3. Check for weld between beam web and end plate
4. Check for bending capacity of end plate
5. Check for bearing capacity of flange/end plate
6. Check for weld between gusset plate and beam flange
7. Check for weld between gusset plate and end plate
8. Check for compression capacity of gusset plate
9. Check for gusset plate against minor axis bending
10. Check for bearing of bracing bar
11. Check for block shear capacity of brace bar
12. Check for reduced tension capacity of brace bar

Variation no: Rev date Description


Client : William Hare india Ltd Date : MAR-05
Project : Design Training Manual Calc'd by : PAK
Estimate no : Checked by : CSN
Contract no : C8860
Sheet no : Part1/11

4.5 Vertical Bracing connection(Flats as brace bars)

Design checks required are:

1. Check for shear capacity of bolts connecting flat and gusset plate
2. Check for combined shear and tension capacities bolt connecting the beam and column flange
3. Check for shear,tension and block shear capacities of the flat
4. Check for bending capacities of the gusset plate
5. Check for weld between gusset and beam flange
6. Check for weld between gusset and end plate
7. Check the compression capacity of the gusset

Variation no: Rev date Description


Client : William Hare india Ltd Date : MAR-05
Project : Design Training Manual Calc'd by : PAK
Estimate no : Checked by : CSN
Contract no : C8860
Sheet no : Part1/12

4.6 Horizontal Bracing connection (Angles as brace bars):

Design checks required are :

1. Check for combined shear and tension capacity of bolts between endplate and column web
2. Check for weld between beam web and end plate
3. Check for bending capacity of end plate
4. Check for bearing capacity web/end plate
5. Check for weld between gusset plate and beam web
6. Check for weld between gusset plate and end plate
7. Check for compression capacity of gusset plate
8. Check for gusset plate against minor axis bending
9. Check for bearing of bracing bar
10. Check for block shear capacity of brace bar

Variation no: Rev date Description


Client : William Hare india Ltd Date : MAR-05
Project : Design Training Manual Calc'd by : PAK
Estimate no : Checked by : CSN
Contract no : C8860
Sheet no : Part1/13

4.7 Horizontal bracing connection (Hollow section bracings)

Design Checks required are:

1. Check the bolts connecting supporting and supported beam for combined shear and tension
capacity
2. Check the spade plate for shear,tension and block shear capacities
3. Check the gusset plate for shear,tension and block shear capacities
4. Check the cover plates for shear,tension and block shear capacities
5. Check the weld between the brace bar and spade plate
6. Check the weld between the supported beam web and gusset plate
7. Check the weld between the supported beam endplate and gusset plate
8. Check the weld between beam and endplate
9. Check the supporting beam web tying/bending capacity
10. Check the thickness of the endplate
11. Check the compression capacity of the gusset plate
12. Check the wall of the section for shear capacity

Variation no: Rev date Description


Client : William Hare india Ltd Date : MAR-05
Project : Design Training Manual Calc'd by : PAK
Estimate no : Checked by : CSN
Contract no : C8860
Sheet no : Part1/14

4.8 Plan/horizontal bracing connection (Hollow section bracings)

Design Checks required are:

1. Check for combined shear and tension capacities of bolt group.


2. Check for block shear capacities of spade plate
3. Check for bending capacity of end plate.
4. Check for weld between the section/member and the endplate
5. Check for weld between the end plate and spade plate
6. check weld between the beam web and gusset
7. Check for weld between the endplate of the beam and gusset
8. Check for end plate of the beam for tying/bending capacity
9. Check for compression capacity of gusset plate.

Variation no: Rev date Description


Client : William Hare india Ltd Date : MAR-05
Project : Design Training Manual Calc'd by : PAK
Estimate no : Checked by : CSN
Contract no : C8860
Sheet no : Part1/15

5. Column splices:

5.1 with cap and base plate:

A
A

A-A

Design steps involved are:

1. Check for Tension capacity of bolts due to Moment and axial


2. Check for weld between Column flanges and base plate
3. Check for weld between Column web and base plate
4. Check for thickness of cap and base plate required for the Moment carried

Variation no: Rev date Description


Client : William Hare india Ltd Date : MAR-05
Project : Design Training Manual Calc'd by : PAK
Estimate no : Checked by : CSN
Contract no : C8860
Sheet no : Part1/16

5.2 Flange and web plate type column splice

A A

SECTION A-A

Design steps involved are:

1. Check for shear capacity of Flange Bolts


2. Check for Block shear capacity of Column flange plate
3. Check for tension capacity of Flange plates
4. Check for Compression capacity of Flange plates
5. Check for Web Bolt shear capacity
6. Check for Tension capacity of web plate
7. Check for Compression capacity of Web plate

Variation no: Rev date Description


Client : William Hare india Ltd Date : MAR-05
Project : Design Training Manual Calc'd by : PAK
Estimate no : Checked by : CSN
Contract no : C8860
Sheet no : Part1/17

CHS /SHS BRACING BAR WITH SPADE PLATE SLOTED IN TO SECTION USING COVER
PLATES:

CHECKS REQUIRED ARE :

1. Check for shear capacity of bolts


2. Check for bearing capacity of spade/gusset/cover plate (worst case)
3. Check for tension capacity of spade plate
4. Check for weld between spade plate and CHS
5. Check for compression capacity of cover plate
6. Check for shear capacity of CHS bracing wall
7. Check for compression capacity of gusset plate
8. weld between gusset plate and column web
9. weld between gusset plate and base plate

Variation no: Rev date Description


Client : William Hare india Ltd Date : MAR-05
Project : Design Training Manual Calc'd by : PAK
Estimate no : Checked by : CSN
Contract no : C8860
Sheet no : Part1/18

UC BRACING BAR ,FLANGES STRIPPED AND LAPPED ON:

CHECKS REQUIRED ARE:

1. Check for shear and bearing capacity of bolts


2. Check for block shear capacity of brace bar
3. Check for reduced tension capacity of gusset plate
4. Check for Compression capacity of gusset plate
5. Check for gusset plate against minor axis bending
6. Check for weld between gusset plate and beam flange

Variation no: Rev date Description


Client : William Hare india Ltd Date : MAR-05
Project : Design Training Manual Calc'd by : PAK
Estimate no : Checked by : CSN
Contract no : C8860
Sheet no : Part1/19

UC VERTICAL BRACING WITH COVER PLATES:

Work Point

CHECKS REQUIRED ARE:

1. Check for compression capacity of gusset plate


2. Check for Weld b/w gusset plate to column flange
3. Check for Weld between gusset plate and baseplate
4. Check for shear and bearing capacity of bolts between brace and gusset
5. Check for Block shear capacity of web cover plate/brace bar (worst case)
6. Check for compression capacity of cover plates
7. Check for tension capacity of cover plates

Variation no: Rev date Description


Client : William Hare india Ltd Date : MAR-05
Project : Design Training Manual Calc'd by : PAK
Estimate no : Checked by : CSN
Contract no : C8860
Sheet no : Part1/20

HORIZANTAL BRAZING :
Beam to beam end plate connection with UC plan brace

A A

W.P.

SECTION A-A

CHECKS REQUIRED ARE:

1. Check for bolts between brace and gusset


2. Check for bolts in bearing
3. Block shear capacity of brace bar
4. Check for compression capacity of gusset plate
5. Check for weld between end plate and gusset
6. Check for combined shear and tension capacities of bolt group.
7. Check for weld between end plate and beam web
8. Check for weld between end plate and beam flange
9. Check for bending capacity of end plate
10. Check for bearing capacity of end plate / beam web
11. Check for Shear & Bending interaction at the Notch for R.H.S. beam

Variation no: Rev date Description