Vous êtes sur la page 1sur 2

DELIVERABLES PARAMETERS FOR CASE CASE STUDY

STUDY PROJECT
Total area of site in sq. m along with Site area
the site plan
F.A.R and total built up area F.A.R
sanctioned Total built up area
Satellite image Location
Percentage of site area Open space reservation
Can also be considered as frontage Adjoining road width
AREA CLASSIFICATION
Office
Support the area with single line Retail
plans of each of the requirements Amenities
Miscellaneous
Services (Total)
MASSING
Vertical zoning
Total height from ground floor
Stilt floor & Floor to floor height
No. of Basement floors & floor to floor height
Along with the numbers, support
the massing with a basic 3D model, No. of Podium floors & floor to floor height
with different color coding for No. of Tower floors & floor to floor height
different usage No. of Mechanical/Service floors & floor to
floor height
Total number of floors
Number of tower blocks
EXISTING PROVISIONS PER FLOOR
BASEMENT
No. Of car parking
No. of two-wheeler parking
Services placed on basement
Ramp system to basement/width/slope
Any other noticeable usage
PODIUM
Along with the numbers, short Usage
description and thumbnail sketches Location of fire escape staircase
where ever necessary No. of toilets
No. of retail units
Any other noticeable usage
SERVICES CORE OF PODIUM
LIFTS IN PODIUM
Lift system
No. of lifts
No. of banks
Capacity of each lift
Lift well dimension
TOILETS IN PODIUM
No. of toilets on each floor
Mechanical floors should be clearly SERVICE / MECHANICAL FLOORS
highlighted with color coding on Usage
the 3d model along with Access
descriptions and photographs Floor to floor height
Location
Sketch the outline plan of the floor TOWER
plate along with corridors, service
core, fire escape and clearly color Usage
rentable office space Rentable area
Section of individual floor plate
highlighting the depth of floor plate Depth of floor plate from source of light
up to which there is ample day
lighting
Distance of fire escape from the Location of fire escape staircase
farthest point on the floor plate and
dead end from any corridor
Location and area of refuge area
SERVICE CORE OF TOWER
LIFTS
Passenger lift system
No. of passenger lifts
No. of banks
Capacity of each lift
Lift well dimension
No. of service lifts
Along with numbers and area, short Service lift well dimension
description and sketches where FIRE ESCAPE STAIRCASE
ever necessary, along with No. of fire escape staircase
photographs Distance from farthest point on floor plate
TOILETS IN TOWER
No. of toilets on each floor
MEP IN TOWER
Dimension of air handling unit room
Dimension of electrical room
Dimension of service lift lobby
Any other if provided
AESTHETICS AND AMBIENCE
Describe ambience created for different
users within the building considering day
Support with photographs, sketches lighting, volume, surface treatment etc.
Describe the aesthesis of the building with
respect to the form development, material
used for building envelope
Iconic character, influence on urban fabric,
its presence in skyline, etc.

Vous aimerez peut-être aussi