P&H ROPE SHOVEL 2100BL

[10.7m3, 14yd3] Payload 18mt-20mt)


OLD BUCKET NEW BUCKET
DC CURRENT : 122 A DC CURRENT : 122 A
REFERENCE : 1.47 V REFERENCE : 1.47 V
FEEDBACK(VOLTAGE) : 0.09 V FEEDBACK(VOLTAGE) : 0.09 V
DC VOLTAGE : 56V DC VOLTAGE : 56V

Empty Bucket:- Empty Bucket:-


Bucket weight – 25 tons Bucket weight - 34 tons
Time Taken for hoist : (10-12sec) Time Taken for hoist : (20-23sec)
Loading time magnetorque Temp: Loading time magnetorque Temp:
(60o C to 63o C) for 12 hours (Above 117oC ) within 20 mins.
operation.

RPM: Normal speed of generator is RPM: Inner member slipping due


good. to more load. Generator slow and
more current consumption in
operation.

In Empty bucket Normal Torque In Empty bucket get more Torque


and speed. and cause low speed.

Crowd system is normal in operation. Crowd system current is abnormal due


to heavy bucket.

Main motor RPM is 595. When loading Main motor RPM 440 in
Inner member and slipping down.

Insulation is good condition & normal. Within 20 minutes during operation of


loading Trucks smoke coming &more
heat during testing time. After checking
magnet torque field resistance with
ground in Kilo Ohms range found
insulation is poorly weak.
NOTE: NOTE:
In Mangampet we having other spare If we use the same magnet torque in
magnet torque repaired from future it will badly failure.
BICOKLORY KOLKATA. Field
resistance value is 10 mega ohms&
Field resistance is 0.15 ohms.

Magnet torque [magnetic clutch] have a If increase the Bucket size it will
standard bucket size of (10.7 m3) [14yd] damage the Magnet Torque.
payload 18 metric tons. If bucket size is
increased inner member slip, due to This Bucket not suitable for this
excessive of load. This will create Machine.
smoke &excessive heat and insulation
also damaged.

Vous aimerez peut-être aussi