Académique Documents
Professionnel Documents
Culture Documents
OVER
OIL
ACTUAT
OR
GOV
SERIES
GAS OVER OIL
With the in-house capability to manufacture the complete line of control components, Rotex guarantees....
FEATURES
• Gas driven system
- Sour Gas can be used for Gas Over Oil application
- Gas pressure up to 2000 psi
• Storage tank for extra operation
- Secondary storage tank permits up to 3 operations
- Manual valves and NRV are used for preventing
gas to escape one of the line pressure
• Electrically or mechanically operated
• Large range of operating systems are available
• GOV can be installed on DRS, DRV, HYV or any
other make of actuators
• All pressure parts are as per ‘PED’ and available
with certifications
• Recommended oil “Aero Shell Fluid 4” or equivalent
• GOV panel can be completely gas pressure based.
In such cases the manual valves are used for controls
• Solenoid operated GOV panel can be used for remote
operations. SCADA connectivity available
• Gas Over Oil panel with hydraulic • Gas Over Oil with hydraulic tank, line break
control tank, safety reservoir
• ROTEX GOV can also be used for linear actuator for rising stem
valves
• ISO mounting for direct mounting available on the basis of model
selected for actuator
• Standard temperature -20 °F. Special up to -55 °F
• All parts are manufactured from approved material as per NACE
(MR-01-75) suitable for sour gas
• All valves are zero leak construction. We use high pressure PTFE
sealing system, poppet and spool construction for higher reliability
• Manual override is possible with :
- Hydraulic options, to pump by hand to open or close
- Gas storage tank for 2-3 operations
- Manual overrides on solenoid valves to function the open/close
Operation
• Complete panel in stainless steel with all internal in stainless steel
(for gas wetted parts) is available
• Gas filtration/ dehumidification filters are installed within the panel
• System can be configured for line breakage control valve and torque
control valve depending upon the system requirements
• Gas Over Oil control system with various options • Gas Over Oil with built in torque control device
SCHEMATIC - 1
GAS OPERATED SYSTEM
FEATURES SPECIFICATION
• Manual valve for open/ closed Pressure : 0 - 240 bar
• Line break control valve with normal reset Control : 40 - 240 bar
function Sensitivity forward : 1 bar
• Functional valve for logic Sensitivity Reversed : 30 bar
• Torque control valve will ensure torque of Manual reset : built in
actuator never exceeds the maximum stem Ports : 1/4”, 3/8”, 1/2”, 3/4”, 1”
shear torque (MSST)
SCHEMATIC - 2
ELECTRO GAS OPERATED SYSTEM
2
14
LOCAL
RESET 15 16
4
13 6 3
5 5 3
CLOSE OPEN
12
11
10 9
8
7
CUSTOMER ELECTRICAL
CONNECTION
FEATURES SPECIFICATION
• Field control/ control room Pressure : 0 - 240 bar
• SCADA controls can be adopted Control : 40 - 240 bar
• Exd - ATEX solenoid valve Sensitivity forward : 1 bar
• Line break control function can be integrated Sensitivity Reversed : 30 bar
• Maximum torque output control available Manual reset : built in
Ports : 1/4”, 3/8”, 1/2”, 3/4”, 1”
SPECIFICATION
Main valve : 1/4” 3/8” 1/2” 3/4”
Control pressure : 20 to 70 bar
Sensitivity : ± 4 bar
Main pressure : 0 - 220 bar
Response Pressure: 5 bar
SPECIFICATION
Valve size : 1/4”, 3/8”, 1/2”,3/4”
Pressure range of switching valve : 0 - 140 bar
Max. Differential pressure (A-B) : 80 bar
Switching differential pressure : 0.5 to 5 bar
Size : 4 mm
Temperature range : -30 °F to +80 °F
Sensitivity : 0.1 bar/ min
ELEMENTS
FILTERS
5m/ 25m
filters optionally installed in line for gas filtration
Maximum working pressure 220 bar
LOGIC VALVES
1/4”, 3/8”, 1/2”, 3/4” logic valves can be used,
depending upon the flow and operation needed.
Valves can be individually tubed or can be sub base
mounted
www.rotexindia.com