Vous êtes sur la page 1sur 72

Back Print Current Page QUIT

Tyco Fire & Building Products is a


leading manufacturer of water-based
fire suppression system components
and ancillary building construction
products. Continually expanding its
capabilities through innovative research
and product development, it provides its
customers effective fire protection and construction
solutions for residential, commercial, industrial, and
institutional buildings.

What's New

Datasheets now
Introducing Rapid Response Home Fire Sprinkler Systems -- state-of-the-art
available in various
languages! fire protection technology designed especially for the home -- from Tyco Fire
& Building Products. For more information, visit www.tyco-rapidresponse.com.

● Learn more about our Rapid


Play Rapid Response Video
Response Home Fire Spinkler
Model PRV-1 System
Current Price Book
Pressure Regulating Valve
Product Flyer ● Learn more about residential
Play Residential Video
sprinklers installed in the home

** Press "Esc" to stop movies.

Play SprinkFDT Overview Video


Valve Animations
Fire Protection Products
New PRV-1 Animation &
General Catalog
Step-by-Step Play SprinkCODE Overview Video
Fire Protection Software for the
Design Professional

Visitwww.Tyco-Fire.com
www.Tyco-Fire.com

451 North Cannon Ave., Lansdale, PA 19446 • (800) 523-6512 • (215) 362-0700 • Fax: (215) 362-4731

© 2006 Tyco Fire & Building Products LP. All Rights Reserved.
Print Current Page Home

<< Back
Valve Animations

Model PRV-1 Pressure Regulating Valve

■ Animation
■ Step-by-Step

DV-5 Deluge System

Electric Actuation Dry Pilot Actuation Wet Pilot Actuation

■ Animation ■ Animation ■ Animation


■ Step-by-Step ■ Step-by-Step ■ Step-by-Step

DV-1 Dry Pipe System

■ Animation
■ Step-by-Step

© 2006 Tyco Fire & Building Products LP. All Rights Reserved.
Print Current Page Home

<< Back

Technical Data
Technical Data Update - May 2006

● Update Summary Note:


On the following pages, DWG CAD drawings may be available as a hot link. If you do not have
● Table of Contents a CAD program on your computer they will not open for you. All the DWG’s are available on
the CD in a folder called “TFP_DWG”

SPRINKLERS

1. Standard Spray Sprinklers 4. Residential Sprinklers


2. Extended Coverage Sprinklers 5. Dry Sprinklers
3. Storage Sprinklers 6. Special Sprinklers

VALVES & ACCESSORIES

7. Sprinkler Warnings, Patterns & Accessories 12. Air Maintenance Devices


8. Nozzles & Nozzle Accessories 13. Deluge System Valves & Accessories
9. Wet System Valves & Water Motor Alarm 14. Preaction Systems
10. Dry System Valves 15. General Purpose Valves
11. Quick Opening Device

SPECIALTY ITEMS

16 Specialty Items 19. CPVC Pipe & Fittings


17. Steel Pipe & Threaded Fittings 20. Miscellaneous
18. Grooved Products 21. Electrical
22. AquaMist®

© 2006 Tyco Fire & Building Products LP. All Rights Reserved.
Print Current Page Home

<< Back

● Standard Spray ● Wet System Valves & Water ● Grooved Products


● Extended Coverage Motor Alarm ● Material Specifications
● Storage ● Dry Pipe Valves ● Installation, Features &
● Residential ● Quick Opening Devices Benefits
● Dry ● Air Maintenance Devices ● Manufacturing Process
● Special ● Deluge Valves & Accessories ● ISO 9001 Approval
● Sprinkler Accessories ● Preaction Systems & Certification
● Nozzles & Nozzle Accessories ● General Purpose Valves
● Specialty Items
● Solenoid Valves

Associate
Products

● Ansul
● Allied Sprinkler Pipe

● CPVC BlazeMaster® Products ● SprinkCAD (N1 & Pro II)


● CPVC BlazeMaster® Product ● SprinkCALC
Addendum (4-24-02) ● SprinkCODE
● CPVC Submittal Sheet [PDF] ● SprinkSLIC
● ISO 9001 Approroval & ● SprinkFDT
Certification
● Enhanced CPVC Listings

© 2006 Tyco Fire & Building Products LP. All Rights Reserved.
Print Current Page Home

<< Back

We carry the industry's broadest line of automatic fire sprinklers and related equipment, including an extensive inventory of pipe,
valves and sprinkler head devices. Below you will find a complete list of product catalogs and brochures available for additional
information on our products.

Installation Manuals Product Flyers


Advertisements
Product Brochures

Animations

Station House Newsletters


Current Price Book
Technical Reports &
White Papers

© 2006 Tyco Fire & Building Products LP. All Rights Reserved.
Print Current Page Home

<< Back

● United States

● Asia

● Australia

● Canada

● Europe & Middle East

● Latin America

© 2006 Tyco Fire & Building Products LP. All Rights Reserved.
Print Current Page Home

<< Back

TYCO FIRE & BUILDING PRODUCTS WEBSITES


● Tyco Fire & Building Products - Americas ● SprinkCAD
● Tyco Fire and Building Products - Europe ● Grinnell Mechanical Products
● Tyco Fire & Building Products - Asia

VOLUNTARY REPLACEMENT PROGRAM


● Info regarding the Central Sprinkler Voluntary Replacement Program

OMEGA RECALL
● Info regarding the Omega Recall

TRADE ASSOCIATIONS
● NFPA ● ASME - American Society of Mechanical Engineers
● AFSA ● CASA
● NFSA ● ANSI - American Natl. Standards Organization
● NAFED - Natl. Assoc. Fire Equipment Distributors ● ISO - Intl. Organization for Standardization

TRADE MAGAZINES
● Sprinkler Age ● SFPE Publications
● FPC ● Sprinkler Quarterly
● NFPA Journal ● CASA Notes
● PM Engineer

TESTING LABORATORIES
● Factory Mutual ● SSL
● VdS ● LPC
● Underwriters Laboratories ● NSF

INDUSTRY LINKS
● Noveon(TM) BlazeMaster (R)

© 2006 Tyco Fire & Building Products LP. All Rights Reserved.
Print Current Page Home

<< Back

Locate a sprinkler using the "Sprinkler Identification Number"

Enter SIN Lookup


number:SIN

Note: Enter entire SIN number including any character prefix (e.g., TY4951)

Open Datasheet

© 2006 Tyco Fire & Building Products LP. All Rights Reserved.
Print Current Page Home

<< Back

Mobile Valve Demo Unit Training Seminars for the Fire Professional

Tyco Fire & Building Products offers several valuable


training classes throughout the year, designed specifically
for the engineering, design, and enforcement communities,
offering those who attend a unique perspective on the
development, use, and application of the various components
used in automatic fire protection and fixed water spray
systems. These intensive, seminars provide instruction that
ranges from the background and history of the automatic
sprinkler and basic hydraulic calculations, to the development
Tyco Fire Products Mobile Valve Demonstration Unit and application of some of the world's most advanced
offers comprehensive training on the industry's newest innovations in fire protection technology.
technologies by bringing our complete range of valve
products to you. For more information, click here.

For more information on Tyco Fire & Building Products'


Valve Demo Unit, please call 1-800-523-6512
or email valvedemo@tycofp.com

For schedule information, please visit www.tyco-fire.com.

© 2006 Tyco Fire & Building Products LP. All Rights Reserved.
Print Current Page Home

<< Back
1: Standard Spray Sprinklers
T.D. Sheet Description PDF CAD Date

TFP110 Series TY-L, Pendent, Recessed Pendent, & Upright, SR, K=5.6 & 8.0 [Open] DWG file 7-04

TFP120 Series TY-L, Sidewall, Horizontal, SR, K=5.6 [Open] DWG file 7-04

TFP130 Series TY-FRL, Pendent, Recessed Pendent, & Upright, QR, K=2.8, 5.6 & 8.0 [Open] DWG file 7-04

TFP140 Series TY-FRL, Sidewall, Horizontal, QR, K=5.6 [Open] DWG file 7-04

Series TY-B, Pendent, Recessed Pendent, & Upright, SR, K=2.8, 5.6 & 8.0
TFP151 [Open] DWG file 4-06
Translated Versions [PDF]: CS, DE, ES, FR, HU, IT, NL, PL, RU

Series TY-B, Sidewall, Horizontal & Vertical, SR, K=5.6


TFP161 [Open] DWG file 4-06
Translated Versions [PDF]: CS, DE, ES, FR, HU, IT, NL, PL, RU

Series TY-FRB, Pendent, Recessed Pendent, & Upright, QR, K=2.8, 4.2, 5.6
TFP171 & 8.0 [Open] DWG file 4-06
Translated Versions [PDF]: CS, DE, ES, FR, HU, IT, NL, PL, RU

Series TY-FRB, Sidewall, Horizontal & Vertical, QR, K=5.6


TFP176 [Open] DWG file 4-06
Translated Versions [PDF]: CS, DE, ES, FR, HU, IT, NL, PL, RU

Series RFII, Concealed, QR & SR, Standard Coverage, Pendent, K=5.6


TFP181 [Open] DWG file 7-04
Translated Versions [PDF]: CS, DE, ES, FR, HU, IT, NL, PL, RU

TFP190 Model TY-QRF, Flush, QR, Standard Coverage, Pendent, K=5.6 [Open] DWG file 9-04

© 2006 Tyco Fire & Building Products LP. All Rights Reserved.
Print Current Page Home

<< Back
2: Extended Coverage Sprinklers
T.D. Sheet Description PDF CAD Date

Model EC-25, Extended Coverage Area/Density, Upright, SR, K=25.2


TFP213 [Open] DWG file 9-04
Translated Versions [PDF]: CS, DE, ES, FR, HU, IT, NL, PL, RU

Series EC-11 & EC-14, Pendent, Recessed Pendent & Upright, QR & SR,
TFP220 [Open] DWG file 9-04
K=11.2 & 14.0

Model EPEC, Enhanced Protection Extended Coverage, Pendent, K=115


TFP221 [Open] DWG file 12-04
Translated Versions [PDF]: DE, NL

TFP223 Series EC-8, Pendent and Recessed Pendent, QR & SR, K=8.0 [Open] DWG file 1-05

TFP228 Series EC-5, Pendent & Recessed Pendent, QR & SR, K=5.6 [Open] DWG file 1-05

TFP230 Model SW-20 & SW-24, ECOH, Horizontal Sidewall, SR, K=11.2 [Open] DWG file 1-05

TFP250 Model ELOC, Concealed, Extended Coverage, Pendent, QR & SR, K=11.2 [Open] DWG file 1-05

TFP260 Series RFII, Concealed, Extended Coverage, Pendent, QR, K=5.6 [Open] DWG file 1-05

TFP265 Model CHEC, Concealed, Extended Coverage, Horizontal Sidewall, QR, K=8.0 [Open] DWG file 4-04

TFP280 Series TY-FRL, QR-EC, Horizontal Sidewall, K=5.6 & 8.0 [Open] DWG file 1-05

Series TY-FRB, QR-EC, Horizontal Sidewall & Rec. Horizontal Sidewall,


TFP296 K=5.6 & 8.0 [Open] DWG file 4-06
Translated Versions [PDF]: CS, DE, ES, FR, HU, IT, NL, PL, RU

TFP298 Series EC-5, QR-EC, Horizontal Sidewall & Rec. Horizontal Sidewall, K=5.6 [Open] DWG file 1-05

© 2006 Tyco Fire & Building Products LP. All Rights Reserved.
Print Current Page Home

<< Back
3: Storage Sprinklers
T.D. Sheet Description PDF CAD Date

Model ESFR-25(TM), Early Suppression Fast Response, Pendent, K=25.2


TFP312 [Open] DWG file 1-05
Translated Versions [PDF]: CS, DE, ES, FR, HU, IT, NL, PL, RU

Model ESFR-17, Early Suppression Fast Response, Pendent, K=16.8


TFP315 [Open] DWG file 1-05
Translated Versions [PDF]: CS, DE, ES, FR, HU, IT, NL, PL, RU

Model ESFR-17, Early Suppression Fast Response, Upright, K=16.8


TFP316 [Open] DWG file 4-04
Translated Versions [PDF]: CS, DE, ES, FR, HU, IT, NL, PL, RU

Model ESFR-1, Early Suppression Fast Response, Pendent, K=14.0


TFP318 [Open] DWG file 7-04
Translated Versions [PDF]: CS, DE, ES, FR, HU, IT, NL, PL, RU

Ultra K17, Specific Application Control Mode, Upright, SR, K=16.8, 155
TFP330 [Open] DWG file 3-06
Degree F & 200 Degree F

Ultra K17, Specific Application Control Mode, Upright, SR, K=16.8, 286
TFP331 [Open] n/a 3-06
Degree F

Model K17-231, Storage, Pendent & Upright, Standard Coverage, SR, K=16.8
TFP332 [Open] DWG file 1-05
Translated Versions [PDF]: CS, DE, ES, FR, HU, IT, NL, PL, RU

TFP335 Model LD, Large Drop, Upright, K=11.2 [Open] DWG file 1-05

TFP340 Series ELO-231, Pendent & Upright, Standard Coverage, SR, K=11.2 [Open] DWG file 1-05

Series ELO-231B, Pendent & Upright, Standard Coverage, SR, K=11.2


TFP342 [Open] DWG file 1-05
Translated Versions [PDF]: CS, DE, ES, FR, HU, IT, NL, PL, RU

TFP344 Series ELO-231FRB, Pendent & Upright, Standard Coverage, SR, K=11.2 [Open] DWG file 1-05

TFP350 Series TY-L, Intermediate Level, Pendent & Upright, SR, K=5.6 & 8.0 [Open] DWG file 1-05

TFP351 Series TY-B, Intermediate Level, Pendent & Upright, SR, K=5.6 & 8.0 [Open] DWG file 1-05

TFP355 Series TY-FRL, Intermediate Level, Pendent & Upright, QR, K=5.6 & 8.0 [Open] DWG file 7-05

TFP356 Series TY-FRB, Intermediate Level, Pendent & Upright, QR, K=5.6 & 8.0 [Open] DWG file 1-05

© 2006 Tyco Fire & Building Products LP. All Rights Reserved.
Print Current Page Home

<< Back
4: Residential Sprinklers
T.D. Sheet Description PDF CAD Date

TFP400 Series LFII, Residential, Pendent and Recessed Pendent, K=4.9 [Open] DWG file 1-06

Series LFII. Residential , Pendent, Recessed Pendent, and Concealed


TFP408 [Open] DWG file 1-06
Pendent, K=6.9

Series LFII, Residential, Horizontal Sidewall and Recessed Horizontal


TFP410 [Open] DWG file 1-06
Sidewall, K=4.2

Series LFII, Residential, Horizontal Sidewall and Recessed Horizontal


TFP415 [Open] DWG file 1-06
Sidewall, K=5.6

TFP420 Series LFII, Residential, Flush Pendent, K=4.2 [Open] DWG file 1-06

TFP425 Series LFII, Residential, Flush Horizontal Sidewall, K=4.2 [Open] DWG file 1-06

TFP440 Series LFII, Residential, (Flat Plate) Concealed Pendent, K=4.2 [Open] DWG file 1-06

TFP442 Series LFII, Residential, (Flat Plate) Concealed Pendent, K=4.9 [Open] n/a 1-06

Series LFII, Residential, (Domed Plate) Concealed Pendent, Domed Plate,


TFP450 [Open] DWG file 1-06
K=4.9

TFP490 Series LFII, Residential Sprinkler Design Guide [Open] n/a 1-06

© 2006 Tyco Fire & Building Products LP. All Rights Reserved.
Print Current Page Home

<< Back
5: Dry Sprinklers
T.D. Sheet Description PDF CAD Date

Series DS-1, Dry, SR, Standard Coverage, Pendent, Upright, and Hor.
TFP500 Sidewall, K=5.6 [Open] DWG file 4-04
Translated Versions [PDF]: CS, DE, ES, FR, HU, IT, NL, PL, RU

Series DS-1, Dry, QR, Standard Coverage, Pendent, Upright, and Hor.
TFP510 [Open] DWG file 4-04
Sidewall, K=5.6

TFP515 Series DS-C, Dry, QR & SR, Standard Coverage, Concealed Pendent, K=5.6 [Open] DWG file 4-04

TFP518 Series DS-ECC, Dry, QR, Extended Coverage, Concealed Pendent, K=5.6 [Open] DWG file 4-04

TFP520 Series DS-1, Dry, QR & SR, Extended Coverage, Horizontal Sidewall, K=5.6 [Open] DWG file 4-04

TFP530 Series DS-2, Dry, QR & SR, Standard Coverage, Pendent, K=11.2 [Open] DWG file 7-04

TFP540 Series DS-2, Dry, QR & SR, Extended Coverage, Pendent, K=11.2 [Open] DWG file 9-04

TFP590 Model DSB-1, Dry Sprinkler Boot, For Use With TFP Dry Type Sprinklers [Open] DWG file 1-05

© 2006 Tyco Fire & Building Products LP. All Rights Reserved.
Print Current Page Home

<< Back
6: Special Sprinklers
T.D. Sheet Description PDF CAD Date

TFP610 Models BB, SD, and HIP, Attic Sprinklers [Open] DWG file 10-05

Model WS, Window Sprinklers, Horizontal & Vertical Pendent


TFP620 [Open] DWG file 7-05
Translated Versions [PDF]: PL

TFP630 Model CC1, Combustible Concealed Space Sprinklers, K=2.8 [Open] DWG file 7-04

TFP632 Model CC2, Combustible Concealed Space Sprinklers, K=4.2 & 5.6 [Open] DWG file 3-05

Model TY-FRFS, TY-FS Special & TY-FS, Flat Spray Sprinklers, K=57, 80 &
TFP635 115 [Open] DWG file 5-06
Translated Versions [PDF]: CS, DE, ES, FR, HU, IT, NL, PL, RU

TFP650 Model TFP PH2, Institutional, Pendent, Standard Coverage, SR, K=5.6 [Open] DWG file 4-04

TFP652 Model TFP MAX, Institutional, Pendent, Standard Coverage, QR, K=5.6 [Open] DWG file 4-04

Model TFP PH5, Institutional, Horizontal Sidewall, Standard Coverage, SR,


TFP654 [Open] DWG file 4-04
K=5.6

Model TFP MAX, Institutional, Horizontal Sidewall, Standard Coverage, QR,


TFP656 [Open] DWG file 4-04
K=5.6

TFP661 Series TY-B, Conventional (Old Style), SR, K= 5.6 & 8.0 [Open] DWG file 7-04

TFP663 Series TY-B, Conventional, Special Response, K=8.0 & 11.5 [Open] DWG file 7-04

TFP666 Series TY-FRB, Conventional (Old Style), QR, K=5.6 & 8.0 [Open] DWG file 7-04

Series TY-B & TY-FRB, Pendent & Upright, SR & QR, 10 mm orifice, ISO 7/1-
TFP670 [Open] DWG file 7-04
R3/8

TFP672 Series TY-B, Pendent & Upright, Special Response, K=5.7, 8.0, & 11.5 [Open] DWG file 7-04

Series TY-B & TY-FRB, Stainless Steel, SMO, and Titanium, Pendent &
TFP680 [Open] DWG file 7-05
Upright, K=5.6, 8.0

TFP690 Issue D Quartzoid, High Temperature, Upright & Pendent, SR, K=5.6 & K=8.0 [Open] n/a 4-06

© 2006 Tyco Fire & Building Products LP. All Rights Reserved.
Print Current Page Home

<< Back
7: Sprinkler Warnings, Patterns and Accessories
T.D. Sheet Description PDF CAD Date

28-2.0 CSC, 65 One-Piece Sprinkler Escutcheon [Open] n/a 2-92

28-3.0 CSC, 401 Two-Piece Adjustable Sprinkler Escutcheon [Open] n/a 2-92

28-6.0 CSC, Sprinkler Head Cabinet (3, 6, or 12 capacity) [Open] n/a 11-94

TFP700 InstallerWarnings [Open] n/a 10-03

TFP710 Sprinkler Spray Patterns [Open] n/a 10-05

TFP770 Escutcheon Plates, Pendent & Sidewall (Recessed Types) [Open] DWG file 1-06

Model G1 & G4 Guard & G1/S1& G4/S3 Guard w/Shield (K=5.6 & K=8.0
TFP780 [Open] DWG file 12-03
Sprinklers)

Model G2 Guard, WS-2 Shield, and WSG-2 Guard w/Shield (K=11.2


TFP782 [Open] DWG file 1-03
Sprinklers)

© 2006 Tyco Fire & Building Products LP. All Rights Reserved.
Print Current Page Home

<< Back
8: Nozzles and Nozzle Accessories
T.D. Sheet Description PDF CAD Date

TFP800 Type EA-1, Automatic Protectospray¨ Nozzles [Open] n/a 4-06

TFP840 Model B-1, Foam-Water Sprinklers [Open] n/a 3-06

TFP802 Type D3, Protectospray Nozzles [Open] n/a 4-06

TFP802A Type D3, Protectospray Nozzles, Appendix [Open] n/a 4-06

TFP804 Type D4a, Protectospray Nozzles [Open] n/a 4-06

TFP806 Type D3S, Protectospray Nozzles, Eastern Hemisphere [Open] n/a 4-06

TFP810 Model F822 through F834, Mulsifyre¨ Nozzles [Open] n/a 4-06

TFP815 Type HV-14 through HV-60, (High Velocity) Nozzles [Open] n/a 4-06

TFP820 Navy Type G, Nozzle [Open] n/a 4-06

TFP825 Navy Type SB, Flush Deck Nozzles [Open] n/a 4-06

TFP830 Type 1 and 2, Cooling Tower Nozzles [Open] n/a 4-06

TFP835 Issue A and B, Exposure (Window) Sprinklers [Open] n/a 4-06

TFP890 Blow-off Plugs - Open Sprinklers and Protectospray Nozzles [Open] n/a 4-06

© 2006 Tyco Fire & Building Products LP. All Rights Reserved.
Print Current Page Home

<< Back
9: Wet System Valves & Water Motor Alarms
T.D. Sheet Description PDF CAD Date

TFP910 Model AV-1 300, Alarm Check Valves, 300 psi 2-1/2, 4, 6, and 8 Inch [Open] DWG file 3-06

TFP920 Model RC-1, Retard Chamber [Open] DWG file 1-04

TFP921 Model WMA-1, Water Motor Alarm [Open] DWG file 7-04

Model WMA-1, Water Motor Alarm (European Conformity)


TFP922 [Open] DWG file 10-05
Translated Versions [PDF]: CS, DE, ES, FR, HU, IT, NL, PL, RU

TFP930 Pressure Relief Connection [Open] DWG file 1-04

TFP950 Model CV-1FR - Riser Check Valve, 2 through 8 Inch [Open] DWG file 9-04

TFP960 Figure 513D & 513D/R Riser Manifold, NFPA 13D & 13R - 1, 1-1/2 & 2 Inch [Open] n/a 4-06

TFP962 Figure 513, Riser Manifold, NFPA 13 - 1-1/2 through 6 Inch [Open] n/a 4-06

TFP980 Model RSV-1, Residential Domestic Shutoff Valve - 1 and 2 Inch [Open] DWG file 1-06

Model AV-1-300, Alarm Check Valves, 300 psi - 4, 6, and 8 Inch (European
TFP990 Conformity) [Open] DWG file 3-06
Translated Versions [PDF]: CS, DE, ES, FR, HU, IT, NL, PL, RU

© 2006 Tyco Fire & Building Products LP. All Rights Reserved.
Print Current Page Home

<< Back
10: Dry System Valves
T.D. Sheet Description PDF CAD Date

TFP1041 Model DPV-1, Dry Pipe Valve, 4 Inch [Open] DWG file 3-06

TFP1061 Model DPV-1, Dry Pipe Valve, 6 Inch [Open] DWG file 3-06

Model DPV-1, Dry Pipe Valves -- 4 and 6 Inch (European Conformity)


TFP1090 [Open] DWG file 3-06
Translated Versions [PDF]: CS, DE, ES, FR, HU, IT, NL, PL, RU

TD106 GEM, Model F3061, Dry Pipe Valves, 2 and 3 Inch [Open] DWG file 6-97

10-2.0 CSC, Model AF Dry Pipe Valve- 2 and 2-1/2 Inch [Open] n/a 7-96

10-3.2 CSC, Model AF Dry Pipe Valve-3 Inch [Open] n/a 7-96

© 2006 Tyco Fire & Building Products LP. All Rights Reserved.
Print Current Page Home

<< Back
11: Quick Opening Device
T.D. Sheet Description PDF CAD Date

TFP1100 Model QRS, Electronic Dry Pipe Valve Accelerator [Open] DWG file 5-06

Model ACC-1, Dry Pipe Valve Accelerator


TFP1112 [Open] DWG file 1-03
Translated Versions [PDF]: CS, DE, ES, FR, HU, IT, NL, PL, RU

2-5.2.10 STAR, Model BB, Exhauster - 2" [Open] n/a 5-92

© 2006 Tyco Fire & Building Products LP. All Rights Reserved.
Print Current Page Home

<< Back
12: Air Maintenance Devices
T.D. Sheet Description PDF CAD Date

Model AMD-1, Air Maintenance Device, Pressure Reducing Type


TFP1221 [Open] DWG file 3-05
Translated Versions [PDF]: CS, DE, ES, FR, HU, IT, NL, PL, RU

Model AMD-2, Air Maintenance Device, Compressor (small, w/o tank) Control
TFP1231 [Open] DWG file 3-05
Type

Model AMD-3, Nitrogen Maintenance Device, High Pressure (Cylinder)


TFP1241 [Open] DWG file 3-05
Reducing Type

© 2006 Tyco Fire & Building Products LP. All Rights Reserved.
Print Current Page Home

<< Back
13: Deluge System Valves & Accessories
T.D. Sheet Description PDF CAD Date

TFP1300 Model DV-5 Red-E Cabinet, Integrated Deluge Fire Protection Package [Open] DWG file 5-06

Model DV-5, Deluge Valve, Vertical or Horizontal, Diaphragm Style, 250 psi, 1-
TFP1305 1/2 thru 8 Inch [Open] DWG file 3-06
Translated Versions [PDF]: CS, DE, ES, FR, HU, IT, NL, PL, RU

Model DV-5, Deluge System, Wet Pilot Actuation, 1-1/2 thru 8 Inch
TFP1310 [Open] DWG file 3-04
Translated Versions [PDF]: CS, DE, ES, FR, HU, IT, NL, PL, RU

Model DV-5, Deluge System, Dry Pilot Actuation, 1-1/2 thru 8 Inch
TFP1315 [Open] DWG file 3-04
Translated Versions [PDF]: CS, DE, ES, FR, HU, IT, NL, PL, RU

Model DV-5, Deluge System, Electric Actuation, 1-1/2 thru 8 Inch


TFP1320 [Open] DWG file 3-04
Translated Versions [PDF]: CS, DE, ES, FR, HU, IT, NL, PL, RU

TFP1330 Model DV-1, Deluge Valve, Vertical, External Resetting, 4 and 6 Inch [Open] DWG file 3-06

TFP1345 Model TCV-1, Thermal Control Valves, 1 and 1-1/2 Inch [Open] DWG file 1-05

TFP1350 Model DV-3, Deluge Valve, Automatic Resetting, 175 psi - 2-1/2 Inch [Open] DWG file 3-06

Model DP-1, Dry Pilot Actuator


TFP1380 [Open] DWG file 3-06
Translated Versions [PDF]: CS, DE, ES, FR, HU, IT, NL, PL, RU

Model MC-1, Manual Control Stations


TFP1382 [Open] DWG file 1-03
Translated Versions [PDF]: CS, DE, ES, FR, PL, RU

Model ASV-1, Automatic Shut-Off Valve for use with DV-5 Deluge Valve
TFP1384 [Open] DWG file 3-06
Translated Versions [PDF]: CS, DE, ES, FR, HU, IT, NL, PL, RU

Model FSV-1, Fail-Safe Valve for use with DV-5 Deluge Valves
TFP1386 [Open] DWG file 3-06
Translated Versions [PDF]: CS, DE, ES, FR, HU, IT, NL, PL, RU

Model FTR-1, Fixed Temperature Release


TFP1388 [Open] DWG file 7-04
Translated Versions [PDF]: CS, DE, ES, FR, HU, IT, NL, PL, RU

© 2006 Tyco Fire & Building Products LP. All Rights Reserved.
Print Current Page Home

<< Back
14: Preaction Systems
T.D. Sheet Description PDF CAD Date

TFP1400 Model DV-5 Red-E Cabinet, Integrated Preaction Fire Protection Package [Open] DWG file 5-06

Single Interlock
TFP1410 Model DV-5, Single Interlock System, Wet Pilot Actuation, 1-1/2 thru 8 Inch [Open] DWG file 9-04

TFP1415 Model DV-5, Single Interlock System, Dry Pilot Actuation, 1-1/2 thru 8 Inch [Open] DWG file 9-04

TFP1420 Model DV-5, Single Interlock System, Electric Actuation, 1-1/2 thru 8 Inch [Open] DWG file 9-04

TFP1422 Model DV-3, Single Interlock System, Wet, Dry or Electric Actuation, 2-1/2 Inch [Open] DWG file 1-05

Model DV-1, Single Interlock System, Wet, Dry, or Electric Actuation, 4 and 6
TFP1424 [Open] DWG file 1-05
Inch

Double Interlock, Electric/Pneumatic


Model DV-5, Double Interlock System, Electric/Pneumatic Actuation, 1-1/2
TFP1460 [Open] DWG file 3-05
thru 8 Inch

TFP1462 Model DV-3, Double Interlock System, Electric/Pneumatic Actuation, 2-1/2 Inch [Open] DWG file 1-05

TFP1467 Model DV-3, Double Interlock System, Electric/Electric Actuation, 2-1/2 Inch [Open] DWG file 1-05

Double Interlock, Electric/Electric


Model DV-5, Double Interlock System, Electric/Electric Actuation, 1-1/2 thru 8
TFP1465 [Open] DWG file 9-04
Inch

Model DV-1, Double Interlock System, Electric/Pneumatic Actuation, 4 and 6


TFP1464 [Open] DWG file 1-05
Inch

TFP1469 Model DV-1,Double Interlock System, Electric/Electric Actuation, 4 and 6 Inch [Open] DWG file 1-05

© 2006 Tyco Fire & Building Products LP. All Rights Reserved.
Print Current Page Home

<< Back
15: General Purpose Valves
T.D. Sheet Description PDF CAD Date

Shut-Off Valves
TFP1510 Model BFV-N Grooved End Butterfly Valves - 2-1/2 through 10 Inch [Open] DWG file 3-06

TFP1515 Model BFV-N Wafer Style Butterfly Valves, 2 through 12 Inch [Open] n/a 3-06

TFP1520 Model BFV-N Lug Style Butterfly Valves, 2 through 12 Inch [Open] n/a 3-06

Check Valves
TFP1550 Model CV-1F - 2 through 8 Inch Check Valve [Open] DWG file 9-04

TFP1555 Maintenance Kit for Model CV-1 Check Valve [Open] n/a 7-04

TFP1560 Model CV-2 Check Valves 2-1/2, 4, 6, and 8 Inch [Open] DWG file 3-06

Special Valves
TFP1580 Model PRV-1 Pressure Reducing Valve, 2 through 8 Inch [Open] n/a 5-06

© 2006 Tyco Fire & Building Products LP. All Rights Reserved.
Print Current Page Home

<< Back
16: Specialty Items
T.D. Sheet Description PDF CAD Date

TFP1610 Model FL-1, Fusible Links, 50 lb. [Open] n/a 5-06

TFP1620 Model G16AC812, Automatic Supervisory Air Supply [Open] DWG file 1-05

TFP1630 Model AD-1, Automatic Drain Valve [Open] DWG file 1-03

TFP1632 Model AD-2, Automatic Drain (Ball Drip) Valve [Open] n/a 5-06

TFP1635 Model F1321, Sight Flow Connections, 1 and 2 Inch [Open] n/a 5-06

TFP1640 Model A, Pipe Line Strainers [Open] n/a 5-06

TFP1642 Model B-1, Pipe Line Strainers [Open] n/a 5-06

TFP1644 ModelC, Pipe Line Strainers [Open] DWG file 5-06

TFP1650 Model F350, Sectional Test &Drain [Open] n/a 5-06

28-9.0 CSC, Signs [Open] n/a 1-95

© 2006 Tyco Fire & Building Products LP. All Rights Reserved.
Print Current Page Home

<< Back
17: Steel Pipe & Threaded Fittings
T.D. Sheet Description PDF CAD Date

TFP1720 Grinnell Figure 40-5 Strap [Open] n/a 9-04

21-3.0 CSC, Ductile Iron Theaded Fittings [Open] n/a 10-01

28-8.0 CSC, Forged Steel Flange - Slip-On Type [Open] n/a 6-91

© 2006 Tyco Fire & Building Products LP. All Rights Reserved.
Print Current Page Home

<< Back
18: Grooved Products
T.D. Sheet Description PDF CAD Date

TFP1800 Grinnell, Fire Protection Submittal Sheet [Open] n/a 10-05

TFP1810 Grinnell, Grooved Fittings [Open] n/a 9-04

TFP1820 Grinnell Figure 705 Flexible Coupling [Open] n/a 7-04

TFP1830 Grinnell Figure 716 Flexible Reducing Coupling [Open] n/a 7-04

TFP1840 Grinnell Figure 707 Flexible Coupling [Open] n/a 7-04

TFP1850 Grinnell Figure 772 Rigid Coupling [Open] n/a 7-04

TFP1854 Grinnell Figure 577 Rigid Coupling [Open] n/a 7-05

TFP1860 Grinnell, Figure 730 Mechanical Tees [Open] n/a 9-04

TFP1880 Grinnell, Figure 71 Flange Adapter [Open] n/a 9-04

TFP1895 Grinnell Fire Protection Gaskets [Open] n/a 7-04

TFP1898 Grinnell Groove Specifications [Open] n/a 7-04

© 2006 Tyco Fire & Building Products LP. All Rights Reserved.
Print Current Page Home

<< Back
19: CPVC Pipe & Fittings
T.D. Sheet Description PDF CAD Date

IH-1900 CPVC Installation & Technical Manual [Open] n/a 1-05

1/IH-1900 CPVC Installation & Technical Manual Addendum #1 [Open] n/a 10-05

TFP1915 CPVC Submittal Sheet [Open] n/a 1-06

19-2.0 CSC, No Block Hanger & Head Set Mounting Bracket [Open] n/a 2-99

© 2006 Tyco Fire & Building Products LP. All Rights Reserved.
Print Current Page Home

<< Back
20: Miscellaneous
T.D. Sheet Description PDF CAD Date

Currently there are no items in this section.

© 2006 Tyco Fire & Building Products LP. All Rights Reserved.
Print Current Page Home

<< Back
21: Electrical
T.D. Sheet Description PDF CAD Date

TFP2180 Solenoid Valves, 1/2 Inch [Open] DWG file 1-03

© 2006 Tyco Fire & Building Products LP. All Rights Reserved.
Print Current Page Home

<< Back
22: AquaMist®
T.D. Sheet Description PDF CAD Date

GEM, AquaMist(R) OH-2 System (AM24 / Light and Ordinary Hazard


TD1172 [Open] n/a 11-97
Occupancies)

GEM, AquaMist Total Compartment Deluge System (AM4 / Flammable Liquid


TD1173 [Open] n/a 6-98
Hazards)

GEM, AquaMist Total Compartment Deluge System (AM10 / Flammable


TD1174 [Open] n/a 11-97
Liquid Hazards)

© 2006 Tyco Fire & Building Products LP. All Rights Reserved.
Print Current Page Home

<< Back

Section 1: Standard Spray Sprinklers


(Click on [summary] for more information or Click on [PDF] or [View] for Technical Data Sheet)
TY-QRF TY-L TY-L
PDF 123kb PDF 176kb PDF 102kb
Flush Pendent Quick Response Pendent, Recessed Pendent & Upright Horizontal Sidewall
Standard Coverage K=5.6 & K=8.0 K=5.6
K=5.6

TY-FRL TY-FRL TY-B


PDF 175kb PDF 101kb PDF 147kb
Quick Response with Q-46 Deflector 5mm Bulb
Pendent, Rec. Pendent & Upright Quick Horizontal Sidewall Pendent, Recessed Pendent & Upright
Response K=5.6 K=5.6 & K=8.0
K=2.8, 5.6 & 8.0
Translated Versions [PDF]:
CS, DE, ES, FR, HU, IT, NL, PL, RU

TY-B TY-FRB TY-FRB


PDF 106kb PDF 191kb PDF 108kb
5mm Bulb 3mm Bulb, Quick Response 3mm Bulb, Quick Response
Horizontal, Recessed Horizontal & Vertical Pendent, Recessed Pendent & Upright Horizontal, Recessed Horizontal Sidewall &
Sidewall K=2.8, K=4.2, K=5.6 & K=8.0 Vertical Sidewall
K=5.6 K=5.6
Translated Versions [PDF]:
Translated Versions [PDF]: CS, DE, ES, FR, HU, IT, NL, PL, RU Translated Versions [PDF]:
CS, DE, ES, FR, HU, IT, NL, PL, RU CS, DE, ES, FR, HU, IT, NL, PL, RU

RFII
PDF 141kb
Standard Response & Quick Response
Royal Flush II Pendent Concealed
K=5.6

Translated Versions [PDF]:


CS, DE, ES, FR, HU, IT, NL, PL, RU

top

© 2006 Tyco Fire & Building Products LP. All Rights Reserved.
Print Current Page Home

<< Back

Section 2: Extended Coverage Sprinklers


(Click on [summary] for more information or Click on [PDF] or [View] for Technical Data Sheet)
EC-25 EC-11 & EC-14 EC-8
PDF 210kb PDF 169kb PDF 112kb
Area/Density, Extended Coverage Quick & Standard Response Quick & Standard Response
Upright Upright, Pendent & Recessed Pendent Pendent & Recessed Pendent
K=25.2 K=11.2 & K=14.0 K=8.0

Translated Versions [PDF]:


CS, DE, ES, FR, HU, IT, NL, PL, RU

EC-5 ELO SW-20 & SW-24 ECOH EC-5


PDF 99kb PDF 101kb PDF 101kb
Quick & Standard Response Sidewall QR-EC
Pendent & Recessed Pendent K=11.2 Horizontal Sidewall & Rec. Horizontal Sidewall
K=5.6 K=5.6

TY-FRB TY-FRL CHEC


PDF 116kb PDF 93kb PDF 149kb
3mm Bulb, Quick Response, Extended Extended Coverage, Quick Response ECLH Concealed, Quick & Standard Response
Coverage Horizontal Sidewall Horizontal Sidewall Extended Coverage
Horizontal & Recessed Horizontal Sidewall K=5.6 & K=8.0 K=8.0
K=5.6 & K=8.0

Translated Versions [PDF]:


CS, DE, ES, FR, HU, IT, NL, PL, RU

ELOC RFII EPEC


PDF 119kb PDF 108kb PDF 105kb
Extended Coverage Royal Flush II Enhanced Protection Extended Coverage
Pendent, Concealed Pendent Concealed Extended Coverage Pendent
K=11.2 K=5.6 K=115

Translated Versions [PDF]:


DE, NL

top

© 2006 Tyco Fire & Building Products LP. All Rights Reserved.
Print Current Page Home

<< Back

Section 3: Storage Sprinklers


(Click on [summary] for more information or Click on [PDF] or [View] for Technical Data Sheet)
ESFR-25 ESFR-17 ESFR-17
PDF 120kb PDF 120kb PDF 173kb
Early Suppression, Fast Response Sprinkler Early Suppression, Fast Response Early Suppression, Fast Response
K=25.2 Pendent Upright
K=16.8 K=16.8
Translated Versions [PDF]:
CS, DE, ES, FR, HU, IT, NL, PL, RU Translated Versions [PDF]: Translated Versions [PDF]:
CS, DE, ES, FR, HU, IT, NL, PL, RU CS, DE, ES, FR, HU, IT, NL, PL, RU

ESFR-1 Ultra K17 Ultra K17


PDF 143kb PDF 76kb PDF 71kb
Early Suppression, Fast Response Sprinkler Upright Upright
K=14.0 Specific Application Specific Application
K=16.8 K=16.8
Translated Versions [PDF]:
CS, DE, ES, FR, HU, IT, NL, PL, RU

K17-231 ELO-231 ELO-231B


PDF 116kb PDF 123kb PDF 110kb
Pendent & Upright Upright & Pendent Upright & Pendent
K=16.8 K=11.2 K=11.2

Translated Versions [PDF]: Translated Versions [PDF]:


CS, DE, ES, FR, HU, IT, NL, PL, RU CS, DE, ES, FR, HU, IT, NL, PL, RU

ELO-231 FRB LD TY-B


PDF 97kb PDF 77kb PDF 106kb
Upright & Pendent Large Drop 5mm Bulb
K=11.2 Upright Intermediate Level Upright w/Shield
K=11.2 K=5.6 & K=8.0

TY-FRB TY-L TY-FRL


PDF 100kb PDF 90kb PDF 105kb
3mm Bulb, Quick Response Standard Response Intermediate Level Upright Sprinkler w/Shield
Intermediate Level Upright w/Shield Intermediate Level Upright w/Shield K=5.6 & K=8.0
K=5.6 & K=8.0 K=5.6 & K=8.0

top

© 2006 Tyco Fire & Building Products LP. All Rights Reserved.
Print Current Page Home

<< Back

Section 4: Residential Sprinklers


(Click on [summary] for more information or Click on [PDF] or [View] for Technical Data Sheet)
LFII LFII LFII
PDF 331kb PDF 562kb PDF 352kb
Low Flow Low Flow Low Flow
Pendent Pendent Sidewall (Horizontal Sidewall)
k=6.9 K=4.9 K=4.2

LFII LFII LFII


PDF 253kb PDF 298kb PDF 270kb
Residential Residential Residential
Concealed Pendent Sprinkler, Domed Plate Concealed Sprinkler Concealed Sprinkler
K=4.9 K=4.2 K=4.9

LFII LFII LFII


PDF 565kb PDF 246kb PDF 263kb
Residential Residential Residential
Flush Pendent Flush Sidewall (Horizontal Sidewall) Sidewall (Horizontal Sidewall)
K=4.2 K=4.2 K=5.6

LFII
PDF 1523kb
Residential Sprinkler Design Guide

top
Print Current Page Home

<< Back

Section 5: Dry Sprinklers


(Click on [summary] for more information or Click on [PDF] or [View] for Technical Data Sheet)
DS-1 DSB-1 DS-1
PDF 253kb PDF 132kb PDF 224kb
Dry, Standard Coverage, Standard Response Dry Sprinkler Boot Dry, Standard Coverage, Quick Response
Pendent, Upright & Horizontal Sidewall For Use With TFP Dry Type Sprinklers Pendent, Upright & Horizontal Sidewall
K=5.6 K=5.6

Translated Versions [PDF]:


CS, DE, ES, FR, HU, IT, NL, PL, RU

DS-C DS-ECC DS-1


PDF 178kb PDF 180kb PDF 152kb
Standard Coverage, Quick & Standard Extended Coverage, Quick Response Dry, Extended Coverage, Quick & Standard
Response Concealed Pendent Response
Concealed Pendent K=5.6 Horizontal Sidewall
K=5.6 K=5.6

DS-2 DS-2
PDF 185kb PDF 211kb
Dry, ELO Standard Coverage, Standard Dry, ELO Extended Coverage, Quick
Response & Quick Response Response & Standard Response
Pendent Pendent
K=11.2 K=11.2

top
Print Current Page Home

<< Back

Section 6: Special Sprinklers


(Click on [summary] for more information or Click on [PDF] or [View] for Technical Data Sheet)
Attic WS CC1
PDF 454kb PDF 167kb PDF 165kb
K=5.6 & K=8.0 Window Sprinklers Combustible Concealed Space Sprinklers
Horizontal & Vertical Pendent K=2.8
K=5.6

Translated Versions [PDF]:


PL

CC2 FTR-1 TY-FRFS, TY-FS Special & TY-FS


PDF 168kb PDF 112kb PDF 167kb
Combustible Concealed Space Sprinklers Fixed Temperature Release Flat Spray Sprinklers
K=5.6 K=57, 80 & 115
Translated Versions [PDF]:
CS, DE, ES, FR, HU, IT, NL, PL, RU Translated Versions [PDF]:
CS, DE, ES, FR, HU, IT, NL, PL, RU

TFP PH2 TFP MAX TFP PH5


PDF 153kb PDF 155kb PDF 184kb
Institutional Pendent Institutional Pendent Institutional Horizontal Sidewall
Standard Response Sprinkler Quick Response Standard Response Sprinkler
K=5.6 K=5.6 K=5.6

TFP MAX TY-B TY-B


PDF 195kb PDF 118kb PDF 108kb
Institutional Horizontal Sidewall 5mm Bulb 4mm Bulb
Quick Response Conventional (Old Style) Conventional, Special Response
K=5.6 K=5.6 & K=8.0 K=8.0 & K=11.5

TY-FRB TY-B & TY-FRB Issue "D" Quartzoid


PDF 112kb PDF 168kb PDF 90kb
3mm Bulb, Quick Response Stainless Steel, SMO, and Titanium High Temperature
Conventional (Old Style) Pendent & Upright Upright & Pendent
K=5.6 & K=8.0 K=5.6, 8.0 K=5.6 & K=8.0

top
© 2006 Tyco Fire & Building Products LP. All Rights Reserved.

© 2006 Tyco Fire & Building Products LP. All Rights Reserved.
Print Current Page Home

<< Back

Section 7: Sprinkler Warnings, Patterns and Accessories


(Click on [summary] for more information or Click on [PDF] or [View] for Technical Data Sheet)
InstallerWarnings Sprinkler Spray Patterns Escutcheon Plates
PDF 420kb PDF 3251kb PDF 262kb
Pendent & Sidewall (Recessed Types)

65 401 Sprinkler Head Cabinet


PDF 34kb PDF 35kb PDF 29kb
One-Piece Sprinkler Escutcheon Two-Piece Adjustable Sprinkler Escutcheon (3, 6 or 12 capacity)

Guards/Shields Guards/Shields
PDF 431kb PDF 411kb
Model G1 & G4 Guard, G1/S1 & G4/S3 Guard Model G2 Guard, WS-2 Shield, and WSG-2
w/Shield Guard w/Shield
(5.6K & 8.0K Sprinklers) (11.2K Sprinklers)

top

© 2006 Tyco Fire & Building Products LP. All Rights Reserved.
Print Current Page Home

<< Back

Section 8: Nozzles and Nozzle Accessories


(Click on [summary] for more information or Click on [PDF] or [View] for Technical Data Sheet)
Protectospray Protectospray Protectospray
PDF 88kb PDF 77kb PDF 83kb
Type D4a Type D-3 Type EA-1

High Velocity Spray A and B B-1


PDF 169kb PDF 73kb PDF 75kb
Type HV Exposure (Window) Sprinklers 1/2" Foam Water Sprinkler

Blow-off Plugs
PDF 45kb
for Open Sprinklers and Protectospray Nozzles

top

© 2006 Tyco Fire & Building Products LP. All Rights Reserved.
Print Current Page Home

<< Back

Section 9: Wet System Valves & Water Motor Alarms


(Click on [summary] for more information or Click on [PDF] or [View] for Technical Data Sheet)
RSV-1 AV-1-300 AV-1-300
PDF 573kb PDF 1206kb PDF 1056kb
Residential Domestic Shutoff Valve Alarm Check Valves Alarm Check Valves, 300 psi - 4, 6, and 8 Inch
1 and 2 Inch 300 psi (European Conformity)
2-1/2, 4, 6, and 8 Inch
Translated Versions [PDF]:
CS, DE, ES, FR, HU, IT, NL, PL, RU

590FR 513 513D and 513D/R


PDF 539kb PDF 99kb PDF 81kb
Riser Check Valve Riser Manifold Riser Manifold
2 through 8 Inch

WMA-1 WMA-1 Pressure Relief Connection


PDF 151kb PDF 85kb PDF 150kb
Water Motor Alarm Water Motor Alarm (European Conformity)

Translated Versions [PDF]:


CS, DE, ES, FR, HU, IT, NL, PL, RU

RC-1
PDF 471kb
Retard Chamber

top

© 2006 Tyco Fire & Building Products LP. All Rights Reserved.
Print Current Page Home

<< Back

Section 10: Dry System Valves


(Click on [summary] for more information or Click on [PDF] or [View] for Technical Data Sheet)
F3061 DPV-1 DPV-1
PDF 785kb PDF 603kb PDF 607kb
Dry Pipe Valves Dry Pipe Valve Dry Pipe Valve
2 & 3 Inch 4 Inch 6 Inch

DPV-1 AF Dry Pipe Valve AF Dry Pipe Valve


PDF 1970kb PDF 246kb PDF 293kb
Dry Pipe Valves -- 4 and 6 Inch (European 2 & 2-1/2 Inch 3 Inch
Conformity)

Translated Versions [PDF]:


CS, DE, ES, FR, HU, IT, NL, PL, RU

top

© 2006 Tyco Fire & Building Products LP. All Rights Reserved.
Print Current Page Home

<< Back

Section 11: Quick Opening Device


(Click on [summary] for more information or Click on [PDF] or [View] for Technical Data Sheet)
QRS ACC-1 BB
PDF 697kb PDF 537kb PDF 541kb
Electronic Dry Pipe Valve Accelerator Dry Pipe Valve Accelerator Exhauster - 2"

Translated Versions [PDF]:


CS, DE, ES, FR, HU, IT, NL, PL, RU

top

© 2006 Tyco Fire & Building Products LP. All Rights Reserved.
Print Current Page Home

<< Back

Section 12: Air Maintenance Devices


(Click on [summary] for more information or Click on [PDF] or [View] for Technical Data Sheet)
AMD-1 AMD-2 AMD-3
PDF 115kb PDF 146kb PDF 172kb
Air Maintenance Device Air Maintenance Device Nitrogen Maintenance Device
Pressure Reducing Type Compressor (small w/o tank) Control Type High Pressure (Cylinder) Reducing Type

Translated Versions [PDF]:


CS, DE, ES, FR, HU, IT, NL, PL, RU

top

© 2006 Tyco Fire & Building Products LP. All Rights Reserved.
Print Current Page Home

<< Back

Section 13: Deluge System Valves & Accessories


(Click on [summary] for more information or Click on [PDF] or [View] for Technical Data Sheet)
DV-5 DV-5 DV-5
PDF 123kb PDF 191kb PDF 1763kb
Red-E Cabinet Deluge Valve (FL x FL) Wet Pilot Actuation
ntegrated Deluge Vertical or Horizontal, Diaphragm Style, 250 psi 1-1/2 thru 8 inch
Fire Protection Package 1-1/2 thru 8 inch
Translated Versions [PDF]:
Translated Versions [PDF]: CS, DE, ES, FR, HU, IT, NL, PL, RU
CS, DE, ES, FR, HU, IT, NL, PL, RU

DV-5 DV-5 DV-1


PDF 2387kb PDF 1905kb PDF 1118kb
Dry Pilot Actuation Electric Actuation Deluge Valve (FL x FL, FL x GR)
1-1/2 thru 8 inch 1-1/2 thru 8 inch Vertical, External Resetting
4 & 6 Inch
Translated Versions [PDF]: Translated Versions [PDF]:
CS, DE, ES, FR, HU, IT, NL, PL, RU CS, DE, ES, FR, HU, IT, NL, PL, RU

DV-3 TCV-1 DP-1


PDF 974kb PDF 88kb PDF 64kb
Deluge Valve Thermal Control Valves Dry Pilot Actuator
Automatic Resetting, 175 psi 1 & 1-1/2 Inch
2-1/2 Inch Translated Versions [PDF]:
CS, DE, ES, FR, HU, IT, NL, PL, RU

MC-1 ASV-1 FSV-1


PDF 91kb PDF 115kb PDF 60kb
Manual Control Stations Automatic Shut-Off Valve Fail-Safe Valve
for use with DV-5 Deluge Valve for use with DV-5 Deluge Valves
Translated Versions [PDF]:
CS, DE, ES, FR, PL, RU Translated Versions [PDF]: Translated Versions [PDF]:
CS, DE, ES, FR, HU, IT, NL, PL, RU CS, DE, ES, FR, HU, IT, NL, PL, RU

FTR-1
PDF 112kb
Fixed Temperature Release

Translated Versions [PDF]:


CS, DE, ES, FR, HU, IT, NL, PL, RU

top

© 2006 Tyco Fire & Building Products LP. All Rights Reserved.
Print Current Page Home

<< Back

Section 14: Preaction Systems


(Click on [summary] for more information or Click on [PDF] or [View] for Technical Data Sheet)
DV-5 DV-5 DV-5
PDF 200kb PDF 1023kb PDF 937kb
Red-E Cabinet Single Interlock System Single Interlock System
Integrated Preaction Wet Pilot Actuation Dry Pilot Actuation
Fire Protection Package 1-1/2 thru 8 inch 1-1/2 thru 8 inch

DV-5 DV-5 DV-5


PDF 881kb PDF 1713kb PDF 902kb
Single Interlock System Double Interlock System Double Interlock System
Electric Actuation Electric/Pneumatic Actuation Electric/Electric Actuation
1-1/2 thru 8 inch 1-1/2 thru 6 inch 1-1/2 thru 8 inch
Preaction System Preaction System Preaction System
PDF 198kb PDF 405kb PDF 254kb
Single Interlock (Supervised) Double Interlock (Electric/Pneumatic Release) Double Interlock (Electric/Electric Release)
DV-1 DV-1 DV-1
4 & 6 Inch 4&6 4 & 6 Inch
Preaction System Preaction System Preaction System
PDF 210kb PDF 265kb PDF 251kb
Single Interlock (Supervised) Double Interlock (Electric/ Pneumatic Release) Double Interlock (Electric/Electric Release)
DV-3 DV-3 DV-3
2-1/2 Inch 2-1/2 Inch 2-1/2 Inch

top

© 2006 Tyco Fire & Building Products LP. All Rights Reserved.
Print Current Page Home

<< Back

Section 15.1: Shut-Off Valves or Section 15.2: Check Valves


(Click on [summary] for more information or Click on [PDF] or [View] for Technical Data Sheet)
CV-1F CV-2 BFV-N
PDF 510kb PDF 213kb PDF 164kb
Check Valve Check Valves Butterfly Valves
2 through 12 Inch 2-1/2, 4, 6, and 8 Inch Grooved End
2-1/2 through 10 Inch

PRV-1 Model BFV-N Model BFV-N


PDF 283kb PDF 190kb PDF 186kb
Pressure Regulating Valve Butterfly Valve Butterfly Valves
2 through 8 inch Wafer Style Lug Style
2 through 12 inch 2 through 12 Inch

top

© 2006 Tyco Fire & Building Products LP. All Rights Reserved.
Print Current Page Home

<< Back

Section 16: Specialty Items


(Click on [summary] for more information or Click on [PDF] or [View] for Technical Data Sheet)
Model FL-1 Model A Model B
PDF 151kb PDF 277kb PDF 480kb
Fusible Links Pipe Line Strainers Pipe Line Strainers
50 lb

Model C Signs Model AD-2


PDF 964kb PDF 41kb PDF 153kb
Pipe Line Strainers Identification Signs Automatic Drain (Ball Drip) Valve

Model F350 Model F1321 G16AC812


PDF 226kb PDF 210kb PDF 162kb
Sectional Test &Drain Sight Flow Connections Automatic Supervisory Air Supply
1 and 2 Inch

AD-1
PDF 91kb
Automatic Drain Valve

top

© 2006 Tyco Fire & Building Products LP. All Rights Reserved.
Print Current Page Home

<< Back

Section 21: Electrical


(Click on [summary] for more information or Click on [PDF] or [View] for Technical Data Sheet)
Solenoid Valves
PDF 94kb
1/2 Inch

top

© 2006 Tyco Fire & Building Products LP. All Rights Reserved.
Print Current Page Home

<< Back

Section
(Click on [summary] for more information or Click on [PDF] or [View] for Technical Data Sheet)
40-5 Strap Ada-Cap(R) Grooved Fittings
PDF 481kb PDF 530kb PDF 530kb
An economical alternative to welded pipe Used to install the last sprinkler head on Provides an economical and efficient method
outlets on steel pipe. It may be used with full grooved branch line piping or as a drain fitting. of changing direction, adding an outlet,
lengths of pipe and eliminates threading and reducing, or capping grooved piping systems.
welding, decreasing installation time.

Figure 705 Figure 716 Figure 707


PDF 88kb PDF 89kb PDF 91kb
Flexible Coupling Flexible Reducing Coupling Flexible Coupling
Used with 1-1/4" through 12" piping to provide Reducing coupling that allows easy transition Used with 1-1/4" through 12" piping to provide
ease of installation. It provides the needed between two different size pipes, making the ease of installation. These couplings provide
flexibility to accommodate differential 716 faster and easier than threading, welding the needed flexibility for movement.
movement. or using flanges.

Figure 772 Figure 577 Figure 730


PDF 92kb PDF 139kb PDF 539kb
Rigid Coupling Rigid Coupling Mechanical Tees
Designed to give secure rigidity in grooved Provides a rigid joint by firmly gripping along May be used for any tee connection where a
piping systems. Sizes 1-1/4" through 12". the circumference of the pipe groove and are threaded or grooved outlet is needed. May be
preferred for dry pipe and freezer applications. converted into a cross when necessary.
Sizes 1-1/4" through 8".

Figure 71
PDF 484kb
Flange Adapter
Allows a direct transition from flanged
components to a grooved piping system.

top

© 2006 Tyco Fire & Building Products LP. All Rights Reserved.
Print Current Page Home

<< Back

Material Specifications

Metallurgical Specifications:
Central Grooved Piping Products are domestically manufactured in our state of the art ductile iron foundry. The applicable
material specifications for ductile iron, galvanizing and rubber-injection apply.

Housing / Fitting Specifications:

ASTM A-536 - Standard Specification for Ductile Iron Castings Grade 65-45-12
Tensile Strength, minimum psi - 65,000
Yield Strength, minimum psi -45,000
Elongated in 2" or 50mm, minimum % - 12
ASTM A-153 - Standard Specification for Hot Dip Galvanizing

Gasket Specifications:

Grade ‘E’ EPDM gaskets have a green color code identification and conform to ASTM D-2000 for service temperature
from -30°F (-34°C) to 230°F (110°C). They are recommended for hot water not to exceed 230°F (110°C), plus a variety of
dilute acids, oil free air and many chemical services. They are not recommended for petroleum services.

Grade ‘T’ Nitrile gaskets have an orange color code identification, and conform to ASTM D-2000 for service temperatures
from -20°F (-29°C) to 180°F (82°C). They are recommended for petroleum products, vegetable oils, mineral oils, and air
with oil vapors.

Grade ‘A’ EPDMA gaskets have a violet color code identification, and conform to ASTM D-2000 for fire protection
services. They are not recommended for hot water services. For dry pipe or freezer systems,
use tri-seal Grade ‘E’ gaskets.

Bolt / Nut Specifications:

Bolts and Nuts: Coupling bolts and nuts are heat treated carbon steel, oval-neck track head bolts and heavy hex nuts,
conforming to ASTM A-183 with a minimum tensile strength of 110,000 psi.

Bolts and nuts are Zinc electroplated.

Paint Specifications:

Orange - non lead (standard)


Fire Brigade Red - non lead (optional)

© 2006 Tyco Fire & Building Products LP. All Rights Reserved.
Print Current Page Home

<< Back

Grinnell® Fire Protection Installation


Grooved Product Features and Benefits

Grinnell® Fire Protection Grooved Products provide several design features and benefits when compared to welded or
flanged systems.

Field modifications are easily accommodated with the Grinnell® Grooved System as couplings and fittings can be easily
rotated, eliminated and/or added to facilitate the necessary modification.

Economical Rigidity Alignment

Grinnell® Grooved Couplings are the Grinnell® Rigid Grooved Couplings are Every Grinnell® Grooved Coupling is a
fastest method to join steel pipe. There is ideally suited for valve and fitting union which provides easy access for
no need for two holing with flanges, and connections, long runs, and risers where maintenance or piping system modification.
the potential of fire hazards is eliminated pipe movement is undesirable. Rigid Field modification can be handled easily
when compared to welding. couplings provide for joints which are with minimal effort due to the
comparable to pipe jointing such as interchangeability of the grooved method.
welding and flanging.

Retrofit Ease of Insulation Dependability

The Grinnell® Grooved System method The Grinnell® Grooved Piping System is The coupling housing are designed to
allows for quick economical changes as easily insulated with pre-fabricated molded engage into the grooves and provide a
necessary for field retrofit, with the ability insulation. The aesthetics of the pre- secure joint. The pipe ends are sealed by a
to isolate equipment and piping systems fabricated insulation with the economics of pressure responsive gasket which is
for tenant changes and system repair. the grooved methods provide the installer a encapsulated by the ductile iron housing.
significant advantage.

Flexibility Noise & Vibration

Grinnell® Flexible Grooved Couplings The resiliency of Grinnell® Grooved Couplings with various elastomer gaskets provide
allow for expansion, contraction and excellent noise and vibration dampening. The engineering design of the couplings
deflection of the piping system. The provide for pipe end gapping which helps to dissipate, isolate, and minimize noise and
benefit of flexibility can minimize or vibration transmission throughout the piping system.
eliminate the need for expansion joints.

© 2006 Tyco Fire & Building Products LP. All Rights Reserved.
Print Current Page Home

<< Back

Grinnell® Fire Protection Installation


Grooved Manufacturing Process

Casting
Tyco Fire & Building Products produces ductile iron, ASTM A-536, Grade 65-45-12 for all of its
Grinnell® Grooved Products. Once the base iron is produced, magnesium is added in precise
measurements to develop the ductile iron grade. The metal is tested chemically, physically, and
microscopically prior to being released for production. Once cast, the ductile iron is again checked
to ensure conformance with these specifications.

Rubber Injection
Tyco Fire & Building Products understands the complexity of providing
gaskets capable of exceeding customer demands. With state of the art
rubber injection presses and tooling, we are able to mold several types of
rubber compounds to meet the various needs of the mechanical market. The
gaskets are manufactured in our facility in Alabama and each gasket is
inspected to ensure it is defect free. Physical tests are performed on the
gaskets to verify compliance with specifications such as ASTM D-2000.

The Paint Process


Grinnell Grooved Products are painted using a computer controlled semi-
automatic process. This process ensures that each product is spray
washed, dried, pre-heated, dipped and fully cured prior to being
assembled or packaged for shipment. All painted parts are quality
controlled to maintain consistent paint coverage and surface condition.

Tooling
Grinnell Products are designed utilizing the finest engineering talent and innovative practices
available. Our engineering department provides product designs to our pattern centers as well as
contracted pattern makers. The Grinnell patterns and our foundry molding machines are capable
of providing the closest tolerance parts available using the green sand method of casting. With our
in-house process, we have the ability to construct, maintain and modify patterns to meet the
demands of the market place.

© 2006 Tyco Fire & Building Products LP. All Rights Reserved.
Print Current Page Home

<< Back

ISO 9001 Approval & Certification

© 2006 Tyco Fire & Building Products LP. All Rights Reserved.
Print Current Page Home

<< Back

Section 19: CPVC Pipe & Fittings


(Click on [summary] for more information or Click on [PDF] or [View] for Technical Data Sheet)
CPVC CPVC CPVC Submittal Sheet
PDF 870kb PDF 117kb PDF 197kb
Installation & Technical Manual Installation & Technical Manual Addendum #1

No Block
PDF 125kb
Hanger & Head Set Mounting Bracket

top

© 2006 Tyco Fire & Building Products LP. All Rights Reserved.
Print Current Page Home

<< Back
Addendum dated April 24, 2002 to Tyco Fire Products
Installation Instructions & Technical Manual
No. 19-1.0, TD910, 4-1.1.10, Rev. 8 Dated 8/2001:

Tyco Fire Products


BlazeMaster™ CPVC Sprinkler Pipe and Fittings for use with Listed Light Hazard, Quick
Response, Extended Coverage Sprinklers

In accordance with the UL Listing, Tyco Fire Products BlazeMaster™ CPVC Fire Sprinkler pipe and
fittings may be installed without protection (exposed) when subject to the following additional limitations:

1. Exposed piping is to be installed below a smooth, flat, horizontal ceiling construction.

2. Listed pendent, light hazard, quick response, extended coverage sprinklers, 155ºF maximum
temperature rating having deflectors installed within 8 in. from the ceiling and a maximum distance
between sprinklers not to be less than 15 ft and not to exceed 20 ft with an application density of
at least 0.10 gpm/sqft.

3. Listed pendent residential sprinklers, 155ºF maximum temperature rating having deflectors
installed within 8 in. from the ceiling and a maximum distance between sprinklers not to be less
than 15 ft and not to exceed 20 ft with an application density of at least 0.10 gpm/sqft.

4. Listed horizontal sidewall, light hazard, quick response, extended coverage sprinklers, 165ºF
maximum temperature rating having deflectors installed within 6 in. from the ceiling and within 4
in. from the sidewall and a maximum distance between sprinklers not to be less than 14 ft and not
to exceed 18 ft with an application density of at least 0.10 gpm/sqft.

5. Listed horizontal sidewall residential sprinklers, 165ºF maximum temperature rating having
deflectors installed within 6 in. from the ceiling and within 4 in. from the sidewall and a maximum
distance between sprinklers not to be less than 14 ft and not to exceed 18 ft with an application
density of at least 0.10 gpm/sqft.

6. When using fittings in the 1-1/2 in. and greater size only schedule 80 fittings may be used.

7. The end use application is limited to unobstructed construction.

8. All solvent cement joints shall be made with TFP-500 One Step Solvent Cement.

© 2006 Tyco Fire & Building Products LP. All Rights Reserved.
Print Current Page Home

<< Back

© 2006 Tyco Fire & Building Products LP. All Rights Reserved.
Print Current Page Home

<< Back

BlazeMaster® Enhanced Listings

BlazeMaster® CPVC Pipe Becomes First Non-Metallic Pipe Approved for Use in Unfinished Basements and Exposed
System Risers
BlazeMaster® CPVC pipe and fittings are now Listed by Underwriters Laboratories, Inc. (UL) for use in unfinished
basements with exposed solid wood joist installations in accordance with NFPA 13D and in exposed system risers in
accordance with NFPA 13D and 13R. BlazeMaster CPVC pipe is the only non-metallic pipe Listed by UL for these
applications.

❍ Unfinished Basements
In one- and two-family dwellings, BlazeMaster CPVC pipe and fittings may be installed
in unfinished basements without protection (exposed) in accordance with NFPA 13D
for horizontal ceilings utilizing 2 in. x 10 in. or 2 in. x 12 in. solid wood joists on 16 in.
centers. When installed exposed, the system must utilize a residential sprinkler head
with a maximum temperature rating of 155°F, with deflectors a maximum of 1-3/4 in.
below the bottom of the wood joist. Installing the sprinkler head with the deflector 1-3/4
in. below the bottom of the joists accommodated the future addition of a finished ceiling
(reference NFPA 13D, Section 4-2.4, 1999 Edition).

There are additional Listing limitations for BlazeMaster CPVC sprinkler systems installed in unfinished basements with
exposed solid wood joists, so the manufacturer's installation instructions must be referenced before beginning
installation.

BlazeMaster CPVC Now in Combustible Concealed Truss Construction when Space Protected by Central Sprinkler's
Model CC1 Sprinkler Head

❍ Change: Combustible concealed spaces not requiring sprinkler protection by NFPA


standards are presently allowed to be piped using BlazeMaster® CPVC. Up to now,
BlazeMaster® CPVC could not be used in any combustible concealed spaces requiring
sprinkler protection. When using Model CC1 Sprinklers, BlazeMaster® CPVC can now
be installed in combustible concealed space requiring sprinklers in open wood truss
construction.

BlazeMaster® CPVC Now in Ordinary Hazard Applications

❍ Change: An exception to Section 3-3.5 of NFPA 13 was implemented in its 1999 edition which allows BlazeMaster®
CPVC to protect ordinary hazard rooms of otherwise light hazard occupancies where the room does not exceed 400
ft2. Use the same installation guidelines as used for light hazard installations for both concealed and exposed
ordinary hazard applications.

❍ Benefit: Fewer transitions between BlazeMaster® piping and other piping systems or materials.

❍ Examples: Light hazard buildings such as schools, apartments and hotels that contain ordinary hazards rooms such
as storage areas, laundry facilities, or mechanical rooms that do not exceed 400 ft2.

© 2006 Tyco Fire & Building Products LP. All Rights Reserved.
Print Current Page Home

<-back

Advertisements

PRV-1 - Pressure Regulating Valve LFII 4.9 K-Factor Residential Flat Plate Series LFII 6.9 K-factor Residential
Industry’s ONLY FM Approved PRV Concealed Sprinkler Sprinkler
Now, FM Approved!

Superior Commitment DV-5 Valve CHEC


to fire protection DV-5 Valve "Simple Redefined" New CHEC Concealed Horizontal
Extended Coverage Sprinklers

Series LFII Grooved Piping CPVC Systems


Series LFII Residential Sprinklers Grooved Piping Products Complete CPVC Systems Solutions

K17 ESFR DPV-1 Valve Storage Sprinklers


K17 ESFR Upright Storage Sprinkler Model DPV-1 Dry Pipe Valve

© 2006 Tyco Fire & Building Products LP. All Rights Reserved.
Print Current Page Home

<< Back

WORLDWIDE HEADQUARTERS
Tyco Fire & Building Products
451 N. Cannon Avenue
Lansdale, PA 19446
Tel: 215-362-0700
Fax: 215-362-5385
www.tyco-fire.com
UNITED STATES
Fire Protection Technical & Engineering State City Tel: Fax:
Services CA Brea 714-993-6111 714-993-6043
1467 Elmwood Ave. GA Decatur 404-243-7336 404-244-7375
Cranston, RI 02910
PA Norristown 610-239-9925 610-239-9936
Tel: 800-381-9312
Fax: 401-781-7317 MD Jessup 301-604-7133 301-604-7138
IL Carol Stream 630-871-7700 630-871-7464
800-323-9485
Grooved & CPVC Piping Products
Technical & Engr. Services TX Coppell 972-745-0043 972-745-8594
1550 Valley Center Parkway WA Kent 253-872-6030 253-872-6547
Bethlehem, PA 18017 MA Avon 508-583-8447 508-583-0034
Tel: 610-882-4390 FL Pompano Beach 954-781-0866 954-781-1475
Fax: 610-882-4399 UT Murray 801-269-0688 801-269-0733
OR Tigard 503-620-4203 503-620-3817
National Distribution Facility OH Parma 216-265-0505 216-265-8354
PO Box 2806
MO Kansas City 816-842-2424 816-842-4433
Lubbock, TX
79408-2806

top of page

© 2006 Tyco Fire & Building Products LP. All Rights Reserved.
Print Current Page Home

<< Back

ASIA Contacts
ASIA – Regional Headquarters

No.45 Tuas Avenue 9,


Singapore 639189
http://www.tyco-fire.com.cn/

Central Sprinkler Company


Singapore: 65- 6743-3212
Fax 65-6743-9181
Shanghai, China: 86-21-5868-3300
Fax 86-21-5868-1160
Beijing, China: 86-10-6515-6191
Fax 86-10-6515-6157
Chengdu, China: 86-28-689-9440
Fax 86-28-666-2538

Gem Sprinkler Company & Star Sprinkler Inc.


Singapore: 65-6861-1655
Fax 65-6861-1312
Kuala Lumpur, Malaysia:Â 60-3-8024-6773
Fax 60-3-8024-2180
Hong Kong: 852-2595-0686
Fax 852-2505-5826

© 2006 Tyco Fire & Building Products LP. All Rights Reserved.
Print Current Page Home

<< Back

LATIN AMERICA - Regional Headquarters


South America, Mexico
Central America & Caribbean Hamburgo 231A Piso 2
1802 SW 2nd St. Colonia Juarez
Pompano Beach, FL 33069 Mexico, D.F. 06600 Mexico
Tel: 954-781-0866, Tel: 525-55-2075766,
Fax: 954-781-9330 Fax: 525-55-2077566

© 2006 Tyco Fire & Building Products LP. All Rights Reserved.
Print Current Page Home

<< Back

CANADA - Regional Headquarters


12-16715 Yonge Street, Suite 316
Newmarket, Ontario L3X 1X4
Canada Toll-free: 1-866-688-9707
Phone: 705-422-0010
Fax: 705-422-1396

© 2006 Tyco Fire & Building Products LP. All Rights Reserved.
Print Current Page Home

<< Back

Tyco Fire & Building Products offers several Training for the Fire Professional
valuable training classes throughout the year,
designed specifically for the engineering,
design, and enforcement communities,
offering those who attend a unique
perspective on the development, use, and
application of the various components used
in automatic fire protection and fixed water
spray systems. These intensive, seminars
provide instruction that ranges from the
background and history of the automatic General Training Seminar - Cranston, RI - USA
sprinkler and basic hydraulic calculations, to During the intensive two days of training, you will gain an appreciation for the
the development and application of some of various components used in automatic fire protection and fixed water spray
the world's most advanced innovations in fire systems. The curriculum of this training seminar is designed so that students with
protection technology. different backgrounds and experience will benefit. View a Class Schedule for Day
One and Day Two. The third day, for those interested, covers in-depth instruction
● Those wishing to participate in the on a variety of topics, which change from month to month, View the optional
seminar should contact their Tyco Fire Third Day Topics for each date listed below
& Building Products sales
representative, Business Advanced Training Seminar - Cranston, RI - USA
Development manager, or the Tyco The two-day Advanced Training Seminar is available to all individuals who have
Fire & Building Products R&D successfully completed the General Training Program. This training seminar is
training coordinator at compilation of all third day topics normally offered as part of the General Training
(401) 781-8220 ext. 500. Program.
● All seminars take place in Cranston,
RI at Tyco Fire Products Research Training Dates
& Development.
● 2006
● More Questions? Need Directions? ● 2007
Download our Training Brochure
(217kb PDF)

Architect & Engineer Training Seminar - Regional


The Architect & Engineer Training Seminars are designed to assist those who
are actively specifying or designing fire protection systems. The instruction is
concentrated on the various components used in automatic fire protection and
fixed water spray systems. Training is conducted at the Cranston, RI Research &
Development Center or on site as required. Training can range from a one-hour
lunchtime presentation to a full two-day training class.

Training Dates
TBD
(Contact your local Business Development Manager for Training in
your area)

© 2006 Tyco Fire & Building Products LP. All Rights Reserved.
Print Current Page Home

<< Back

© 2006 Tyco Fire & Building Products LP. All Rights Reserved.
Print Current Page Home

<< Back

© 2006 Tyco Fire & Building Products LP. All Rights Reserved.
Print Current Page Home

<< Back

Training for the Fire Professional


Those wishing to participate in the seminar should contact their Tyco Fire & Building
Products sales representative, Business Development manager, or the Tyco Fire &
Building Products R&D training coordinator at (401) 781-8220 ext. 500.

All seminars take place in Cranston, RI at Tyco Fire Products Research &
Development.

(Optional) Third Day Topics


January
More Questions? Need Directions?
Download our ESFR Protection – Design and Application
Training Brochure Installation and Maintenance of wet and dry sprinkler systems
(217kb PDF) February
NFPA 13, 13D & 13R 2002 Update
The Day Three agenda is shown on the right. Installation and Maintenance of deluge and preaction sprinkler systems
March
Click here to see Day One and Day Two agenda.
Use and Application of Specific Application Sprinklers
Installation and Maintenance of wet and dry sprinkler systems
April
Designing a Residential Sprinkler System
Installation and Maintenance of deluge and preaction sprinkler systems
June
Special Hazard Systems – Water Spray Systems
Installation and Maintenance of deluge and preaction sprinkler systems
July
Predicting Water Transit Time in Dry Pipe Sprinkler Systems
Installation and Maintenance of wet and dry sprinkler systems
August
Special Hazard Systems – Water Mist
Installation and Maintenance of deluge and preaction sprinkler systems
September
Pipe Types & Joining Methods – Grooved Piping Products & CPVC
Installation and maintenance of wet and dry sprinkler systems
November
Advanced Hydraulics
Installation and Maintenance of wet and dry sprinkler systems
December
Fire Modeling Using Fire Dynamic Simulator (FDS)
Installation and Maintenance of deluge and preaction sprinkler systems

© 2006 Tyco Fire & Building Products LP. All Rights Reserved.
Print Current Page Home

<< Back

Training for the Fire Professional


Those wishing to participate in the seminar should contact their Tyco Fire & Building
Products sales representative, Business Development manager, or the Tyco Fire &
Building Products R&D training coordinator at (401) 781-8220 ext. 500.

All seminars take place in Cranston, RI at Tyco Fire Products Research &
Development.

More Questions? Need Directions? Download our Training Brochure (217kb PDF)

Day One and Day Two agenda are shown below. Click Here to see Day Three (Optional)

Tyco Fire Products Training Class Tyco Fire Products Training Class
Day One Day Two
8:00 – 8:15am 8:00 – 9:15am
Introduction Protection of Storage
Identify the various methods used to store materials and how
8:15 – 10:00 various materials are classified. Explore the historical
development of storage protection from the standard spray
The Use, Application & Types of Automatic Sprinklers
sprinkler to the ESFR. Identify recent innovations in extended
Explore the historical development of the Automatic Sprinkler
coverage sprinkler protection that allow their use in storage
and the fire protection industry. Identify the components of an
scenarios.
automatic sprinkler, the different types of sprinklers commonly
used in a fire protection system, and how these sprinklers are 9:15 – 9:45
properly applied.
SprinkCode
10:00 – 10:15 Using the state of the art in fire protection software, quickly and
accurately identify the appropriate density and area of
Break
coverage for various occupancies and fire hazards.
10:15 – 12:00pm
9:45 – 10:00
Basic Sprinkler Hydraulics
Discuss how a flow test is conducted and identify how this Break
information is used in the design of a sprinkler system. 10:00 – 11:00
Describe what is meant by the term "density" and discuss
the hydraulic requirements for various occupancies or Residential Sprinklers
hazards. Identify the role the sprinkler orifice or k-factor We will explore the historical development of the Residential
and pipe/fittings plays in the hydraulic design of a Sprinkler and the residential fire protection industry. We will
sprinkler system. identify the rules governing residential sprinkler system
installation; identify how the residential sprinkler has evolved,
12:00 – 12:45 and how to properly utilize this technology.
Lunch 11:00 –12:00pm
12:45 – 3:15 Special Sprinklers
Inevitably, applications present themselves that challenge
Wet and Dry Sprinkler Systems
traditional protection schemes. We will discuss "Specific
Discuss the various types of valves used in a wet and dry pipe
Application Sprinklers", sprinklers designed to meet specific
sprinkler systems. Identify the applicable NFPA requirements
challenges such as the Attic Sprinklers, the Combustible
that govern the installation of this equipment. Through hands
Interstitial Space Sprinklers and Window Sprinklers.
on training, learn the proper operation and maintenance of the
valves and devices utilized in wet and dry sprinkler system 12:00 – 12:45
risers.
Lunch
3:15 – 3:30
12:45 – 2:00
Predicting Water Transit Time in Dry Pipe Systems
Sprinkler Spray Demo
3:30 – 3:45 Witness first hand how various sprinklers distribute water and
vary their applied density or coverage area as a function of
Break
increased pressure. Appreciate the uniqueness of specific
3:45 – 5:00 application sprinklers as compared to standard spray
sprinklers. Show how an automatic sprinkler reacts in a
TFP BlazeMaster CPVC simulated fire scenario.
Identify the benefits as well as the areas where TFP
BlazeMaster CPVC piping systems may be used. Through 2:00 – 3:30
hands on training, learn the proper method of joining and
installing TFP BlazeMaster CPVC pipe and fittings. Deluge & Preaction Systems
Discuss the various types of valves and devices commonly
used in a deluge and preaction systems. Identify the applicable
NFPA requirements that govern the installation of this
equipment. Through hands on training, learn the proper
operation and maintenance of the valves and devices utilized
in deluge and preaction system risers.

3:30 – 3:45
Break

3:45 – 4:30
Deluge & Preaction Systems

4:30 – 5:00
Overview, Summation & Quiz

© 2006 Tyco Fire & Building Products LP. All Rights Reserved.
Print Current Page Home

<-back

Installation Manuals

Tyco Fire and Building Products Piping Handbook


BlazeMaster® (IH-1000) Central Grooved Piping
Installation Handbook Products Installation Handbook

© 2006 Tyco Fire & Building Products LP. All Rights Reserved.
Print Current Page Home

<-back

Product Brochures

Fire Protection Products Catalog Series LF II 6.9 K-Factor Residential Student Housing
TFBP General Catalog - 68 pgs. Sprinkler Fire Protection Systems
(Updated 11-1-04) 2005 Launch

Storage Sprinklers Special Hazards AquaMist Package Brochure


Fire Protection Solutions Special Hazards Fire Protection Complete Fire Protection System
Systems
16 pages

Deluge Poster Sprinkler Application Chart Residential Sprinklers


(actual print size: 24 x 34") (actual print size: 24 x 36") Fire Protection Systems

Training Brochure Grooved Piping Products


R&D
Training Brochure

© 2006 Tyco Fire & Building Products LP. All Rights Reserved.
Print Current Page Home

<-back

Product flyers

Model PRV-1 Models CC1 & CC2 Series LFII


Pressure Regulating Valve Combustible Concealed Space Residential Sprinklers
Sprinklers - Specific Application Upright

Red-E Cabinet™ Model AV-1 Alarm Check Valve Model DSB-1


Integrated Fire Protection Packages Model AV-1 Alarm Check Valve 300 Model DSB-1 Dry Sprinkler Boot for
psi (20,7 bar) 2-1/2 — 8 in. use with TFP dry type sprinklers

Model DD-1 Model QRS Model DV-5


Model DD-1 Wiliag™ condensate drain Electronic Dry Pipe Valve Accelerator Deluge Valves, Diaphragm Style, 1-
1/2" - 8", 250 psi, Vertical or Horizontal
Installation

Zonecheck Model TY3201 - 80 k-factor Model CHEC


Flow Switch Tester Model TY3201 pendent quick response 8.0 K-factor, Concealed Horizontal Ext.
clean room application sprinkler Coverage

© 2006 Tyco Fire & Building Products LP. All Rights Reserved.
Print Current Page Home

<-back

Station House Newsletters

May 2006 February 2006 November 2005

August 2005 May 2005 February 2005

November 2004 August 2004 May 2004

February 2004 November 2003 August 2003

May 2003 February 2003 November 2002

August 2002

© 2006 Tyco Fire & Building Products LP. All Rights Reserved.
Print Current Page Home

<-back

Technical Reports and White Papers

Quick Opening Devices Residential Sprinklers 'White Paper' Residential Sprinklers 'White Paper'
Dry Pipe Valve Accelerators Listings and Applications of Residential Residential Sprinklers Used in NFPA
Sprinklers 13, 2002 Applications, A Technical
Analysis

Dry Pipe Systems 'White Paper' Dry Pendent White Paper EC-25
Variables that affect the performance The Use and Maintenance of Dry Type Application of Tyco Fire Products
of a dry pipe system Sprinklers Model EC-25 Sprinkler

Design Alternatives Welding Fire Protection Piping 101


Design Alternatives for the Large Drop
Sprinkler

© 2006 Tyco Fire & Building Products LP. All Rights Reserved.