CLASSIC

Aeration at its finest!


RUDOLF MESSNER UMWELTTECHNIK RMU
Aeration at its finest!
The MESSNER® Aeration Panel
Arguments:
● Maximum Oxygen Intake The proven MESSNER® Aeration Panel, contains no plasticizers or other additives
● Highest Energy Efficiency equipped with a permanently elastic, ­ and is suitable for continuous and intermittent
● Up to 20 Years of Service Life low-maintenance, non-clogging membrane operation in aeration tanks of municipal and
● Stainless Steel AISI 316L of thermoplastic polyurethane (TPU) industrial wastewater treatment plants.

Technical Data:
MESSNER® Aeration Panel Classic Classic HT Air Connection

Type: V200 -100M50 V200 -100H50


Dimensions (L x W): 2.0 m x 1.0 m 2.0 m x 1.0 m
Active Membrane Area: 2.0 m² 2.0 m²
Airflow per Diffuser: 0 - 60 m³N /h 0 - 40 m³N /h
Max. Wastewater Temperature: 30.0 °C 40.0 °C

Item Material Delivery


1 Air Distribution Pipeline On Site
2 Welding Nipple, 5/4‘‘ On Site Limit of Delivery
3 Ball Valve, 5/4“ Stainless Steel RMU Standard
4 Elbow Union 90°, 40 x 5/4“ PE RMU
5 Air Supply Hose, 40 x 2.3 HD-PE RMU
6 Wall Clip 40 PE RMU
7 Peg 8 x 40 Nylon RMU
8 MESSNER® Aeration Panel Stainless Steel/TPU RMU
9 Drop in Anchor M10 x 40 Stainless Steel RMU

Section „ A - A“

1 Rest Bar RMU – A4


2 Threaded Bolt / DIN913 A4 / M10x80
3 Hex Nut / DIN934 A4 / M10
4 Disk Washer / DIN9021 A4 / 10.5
5 Disk Washer / DIN125 A4 / 10.5
6 Anchor Plug A4 / M10
X Height Adjustment

RUDOLF MESSNER UMWELTTECHNIK AG · Höchstadter Straße 33a · D-91325 Adelsdorf, Germany


Phone: +49 (0) 9195 807-0 · Fax: +49 (0) 9195 807-40 · Email: info@rmu.de · www.rmu.de
Project: WWTP Hanoville - Egypt 10.07.2019
Alternative 1: Temp. < 30°C

Basis of Dimensioning SBR 1 SBR 2 Sludge Tank


(intermittent) (intermittent) (permanent)

Basic Data Unit Rectangular Rectangular Rectangular


Length m 64,20 64,20 23,00
Width m 18,50 18,50 10,00
Water Depth m 5,00 5,00 5,00
Surface m² 1.188 1.188 230
Volume m³ 5.939 5.939 1.150
Above See Level m 5 5 5
V200 100H50 4A V200 100H50 4A
Dimensioning V200-100H50 V200-100H50
Diffuser V200-100M50 V200-100M50 V200-100M50
Number of Pcs. 105 105 16
Membrane Area m² 210 210 32
Floor Coverage % 17,68 17,68 13,91
Mounting Hight m 0,05 0,05 0,05
Aeration Depth m 4,95 4,95 4,95

Oxygen Intake Minimal Load


Oxygen Transfer, Clean Water SOTR1000 kgO2/h 150,7 150,7
Specific Oxygen Transfer SSOTR gO2/m³N.mAD 29,0 29,0
Specific Oxygen Transfer SSOTE %/mAD 9,7 9,7
Specific Airflow per Diffuser q L,St,Bel. m³N/m²Dif.h 5,0 5,0
Standard Airflow 2) Q L,St m³N/h 1.050 1.050
Airflow 3) Q L,St m³/h 1.191 1.191
System Air Pressure 1) ∆p mbar 535 535

Oxygen Intake Normal Load


Oxygen Transfer, Clean Water SOTR1000 kgO2/h 320,0 320,0
Specific Oxygen Transfer SSOTR gO2/m³N.mAD 22,3 22,3
Specific Oxygen Transfer SSOTE %/mAD 7,4 7,4
Specific Airflow per Diffuser q L,St,Bel. m³N/m²Dif.h 13,8 13,8
Standard Airflow 2) Q L,St m³N/h 2.902 2.902
Airflow 3) Q L,St m³/h 3.293 3.293
System Air Pressure 1) ∆p mbar 545 545

Oxygen Intake Design Load


Oxygen Transfer, Clean Water SOTR1000 kgO2/h 400,0 400,0 48,1
Specific Oxygen Transfer SSOTR gO2/m³N.mAD 20,6 20,6 20,2
Specific Oxygen Transfer SSOTE %/mAD 6,9 6,9 6,8
Specific Airflow per Diffuser q L,St,Bel. m³N/m²Dif.h 18,7 18,7 15,0
Standard Airflow 2) Q L,St m³N/h 3.923 3.923 480
Airflow 3) Q L,St m³/h 4.451 4.451 545
System Air Pressure 1) ∆p mbar 552 552 547

Oxygen Intake Maximal Load


Oxygen Transfer, Clean Water SOTR1000 kgO2/h 568,1 568,1 80,5
Specific Oxygen Transfer SSOTR gO2/m³N.mAD 18,2 18,2 16,9
Specific Oxygen Transfer SSOTE %/mAD 6,1 6,1 5,7
Specific Airflow per Diffuser q L,St,Bel. m³N/m²Dif.h 30,0 30,0 30,0
Standard Airflow 2) Q L,St m³N/h 6.300 6.300 960
Airflow 3) Q L,St m³/h 7.148 7.148 1.089
System Air Pressure 1) ∆p mbar 574 574 574

Blowers (existing)
Supplier Aerzener Aerzener
Blower Type 4) GM 80 L GM 35 S
Number of Pcs. 2+1 2x
2)
Standard Airflow Q L,St m³N/h 8.600 2.000
Airflow 3) Q L,St m³/h 9.757 2.269
Air Pressure ∆p mbar 700 700
Motor Power PMot kW
1013 45 77

Tolerances for Oxygen Transfer Values according to DWA-M 209


1) Pressure Loss (Waterdepth, Membrane and Connection Pipe) in as-new condition in clean water
2) Standard airflow: T=273K, P=1,013 bar, RH=0%
3) Intake airflow: T=273+30 K, p=1013 mbar, rF=50 %.
4) Basis of guarantee values
5) Condition: mixer activity during aeration - average flow speed measured above the aerator: v = 0,2-0,25 m/s!
MESSNER Aeration Panel: Pipeline Connection
Type: V20M.. and V20H... Variant 1

Bull 709 - RMU Pipeline Connection 1.doc 1/1 Date: 04/16


64,20m
18,50m

DN300
3 x Magnetic Valve
Drawing number:
RUDOLF MESSNER UMWELTTECHNIK
/-ES01-105F Höchstadter Str. 33a w D-91325 Adelsdorf w Tel.: +49 (9195) 807-0 w Fax: +49 (9195) 807-40
E-Mail: info@rmu.de w www.messner-umwelttechnik.de
Offer number: Description:
-- Tank Layout Sketch 105 MAP
Remark: Project: Scale:
Alternative 1 WWTP Hanoville SBR 1 : 250
09.07.2019 - 15:17
File: Layout Hanovillle.dwg Date: 09.07.2019 Designer: OB K:\Angebote\ÄGYPTEN\WWTP Hanoville\Layout Hanoville.dwg
23,00m

10,00m
DN100
Magnetic Valve
Drawing number:
RUDOLF MESSNER UMWELTTECHNIK
/-ES01-16F Höchstadter Str. 33a w D-91325 Adelsdorf w Tel.: +49 (9195) 807-0 w Fax: +49 (9195) 807-40
E-Mail: info@rmu.de w www.messner-umwelttechnik.de
Offer number: Description:
-- Tank Layout Sketch 16 MAP
Remark: Project: Scale:
-- WWTP Hanoville Sludge Holding Tank 1 : 100
05.07.2019 - 10:53
File: Layout Hanovillle120F.dwg Date: 05.07.2019 Designer: OB K:\Angebote\ÄGYPTEN\WWTP Hanoville\Layout Hanoville120F.dwg
MESSNER Aeration Panel: Solenoid Valve for Maintenance Cycle

Background maintenance cycle:


The unavoidable growth of mineralised and biological deposits (EPS) on the
membrane causes a higher opening pressure of the membrane, resulting in an
efficiency loss of the aeration system. To avoid this negative effect on the aera-
tion system the membrane has to be relaxed several times a day. By switching
off the air supply the membrane, under normal operation conditions stretched
and curved, is relaxing and is laying down plain and flat on the stainless steel
plate. During the relaxing process the above described deposits are unsoldered
from the membrane and therefore a further growth of deposits will be mostly
prevented. This process is called “maintenance cycle”. Important for good
cleaning results of the membrane are the amount of daily cycles, a correct bio-
logical process control and the assured control of the system pressure inside
the piping by using manometers or pressure sensors.
Usage and Function:
After shutdown of the air supply (either by locking the gate valve in the piping or by switching of the blowers) a
pressure equalisation of the air system has to be done, allowing the membrane to relax and therefore maintain
the membrane quality. For this purpose a solenoid valve with assisted lift and reference pipe to the bottom of
the aeration basin is an important part of the MESSNER aeration technology. The solenoid valve will be opened
after shutting down the air supply, allowing the compressed air to escape via the reference pipe until the system
pressure and the hydrostatic pressure are equal (see picture below).
Mode of Operation:
The number of maintenance cycles as well as the “open time” of the solenoid valve are depending on the oper-
ation method of the WWTP and will be defined whilst the initial operation of the aeration system.
a) Continuous operation of the WWTP (e.g. nitrification with upstream or simultaneous denitrification)
In case of continuous operation of the WWTP the duration until the pressure equalization of the aeration system
has to be manually measured. Afterwards an additional buffer time will be added to the measured equalisation
time resulting in the “opening time”. The calculated “opening time” is the necessary parameter for the program-
mable logic control (PLC) of the operational control system of the WWTP.
WWTP without PLC can realize this automated process by using a common timer clock. After the maintenance
cycle is finished the normal aeration mode can be continued. The maintenance cycle should be done several
times a day, but at least twice a day as a minimum.
b) Intermittent operation of the WWTP (e.g. intermittent denitrification or Sequence-Batch Reactor)
In case of intermittent operation of the WWTP the solenoid valve must be closed whilst aeration mode (nitrifica-
tion) and has to be opened whilst non-aeration mode (denitrification).

Technical Data (Danfoss EV250B):


Type: 2/2-way with assisted lift (NC = normally closed)
Installation: Vertical solenoid system is recommended
Electrical data: 230V / 50Hz / 10W (installation by the client)
Coil enclosure: IP 67 (Type: Danfoss BE230AS)
Thread connector: G 1“ (increased to 5/4” with additional connector)
Media Temperature: -30°C to + 120°C
Ambient Temperature: + 80°C max.
Pressure range: 0 – 10 bar
Valve Material: body: brass / armature: stainless steel
Seal material: EPDM
Length: 120 mm inclusive additional connector

Bull 707 - RMU Solenoid Valve for Maintenance Cycle.doc 1/1 Date: 04/16