the availability is expected to reach 95%. As a decreased. Any energy extracted from the bed
result of the stability of the steam reformer material to heat the fluidizing medium up to bed
process, Norampac was able to reduce staff to operating temperature robs energy from the
only one operator per shift. injection zone, which has a very high energy
demand. Colder injection zones can lead to
The GP steam reformers started up in January higher tar formation during pyrolysis of the
2004, and over a similar time period, only liquor. This design deficiency could only be
achieved 8,500 hours of operation on both addressed by the installation of a duct heater or
reformers. GP’s process commissioning was secondary superheater system to increase the
interrupted on several occasions by flow fluidizing medium temperature, but was never
measurement problems and non-process related implemented by GP.
mechanical failures such as fan bearings, high
temperature pump and damper problems, etc. Liquor Uniformity – TRI specified uniform
Once these were resolved, and the system was liquor injection utilizing the complete cross-
able to operate for longer periods, the result of section of the reformer to maximize liquor
the deviations from design specifications became contact with the fluidized bed. This promotes
evident. The major design differences are rapid heating of the liquor by the bed solids
highlighted below. which maximizes volatile yield and minimizes
tar production. In addition, since the liquor at
Reformer Fluidization – Both Norampac and both Norampac and GP contains 40% water, the
GP used bubble cap style fluidizing steam resulting steam bubbles would be uniformly
distributors. The Norampac steam distributor distributed over the bed cross section for
was designed for high pressure drop (to ensure consistent fluidization. For this liquor, the target
uniform bubbling from each cap) and the bubble injection flow is about 1 GPM/injector and
caps were uniformly distributed over the Norampac had 28 liquor injectors that penetrated
reformer cross-section. The GP distributor was the bottom of the vessel in a uniform pattern.
designed with much lower pressure drop (limited During operation, the introduction of liquor in
by air compressor supply pressure) and the this uniform manner does not disrupt the
bubble caps were concentrated in the quadrants, uniformity of bed fluidization. In contrast, GP
leaving gaps down both center lines of the only had 12 liquor injectors that penetrated the
reformer. This deviation proved to be a major side of the vessel forming a circular pattern. In
operational deficiency, and the non-uniform addition, due to layout constraints, the liquor
fluidization patterns caused the bed to defluidize injectors were positioned such that only 3 of the
inside the heater bundles, leading to bed 12 injectors were below the criss-cross heater
agglomeration. GP, Norampac and TRI bundles, with the balance pointing directly into
collaborated on a 1/3 scale cold flow model the open quadrants. The high liquor flow per
testing program that confirmed the Norampac injector and the injector layout encouraged
grid design and verified the deficiency of the GP bypassing of the heater bundles, resulting in
grid design. GP used the cold flow model results cooler liquor injection zones, more tars
to design and test an alternative steam grid. Once production and reduced carbon conversion.
this new grid was installed, GP started to achieve Controlled tests at the pilot scale have
longer operational campaigns. demonstrated that well-atomized liquor droplets
that are uniformly distributed over the whole bed
Fluidizing Steam Temperature – The cross-section increase syngas generation and
fluidizing steam is superheated through heat improve carbon conversion. Similarly,
recovery with the PC heater flue gas. At simulating poor liquor atomization and
Norampac, the fluidizing steam is superheated to distribution, i.e. large droplet size and/or
1100 °F, but at GP the superheater was concentrated flows of liquor into a small volume
undersized and the fluidizing steam was only of the fluidized bed, results in less syngas
delivered to the reformer at approximately 900 production. When poor liquor uniformity was
°F. The zone between the steam grid and the simulated, the pilot heater bundles dropped their
liquor injector, where the steam partial pressure energy input by 10-20% in response to the lower
is high, represents the char reaction zone. When endothermic heat requirement (reduced carbon
steam is introduced below its reaction conversion), syngas production fell by a
temperature, the efficiency of char conversion is
corresponding amount and increased tars Pulse Heater Reliability – Full scale operation
generation was observed. of the PC heaters in both Norampac and GP
revealed that there were several areas that needed
PC Heater Heat Transfer Coefficients – The design improvement; aerovalve assemblies,
measured Heat transfer in the PC heater tube temperature measurement, baffles and the
bundles at Norampac was excellent. The overall decoupler seal. These design improvements
heat transfer coefficients were measured at 95% were implemented on both projects to improve
of maximum design coefficients. Heat transfer the PC Heater reliability.
coefficients at GP were substantially lower,
despite identical heater designs. The higher There were two additional areas where
liquor flows per injector (larger steam bubbles at performance differed between Norampac and
injectors) and the non-uniform injection pattern GP. GP experienced stress corrosion cracking
at GP caused significant disruptions in bed of the combustion chamber tube sheets. Third
fluidization and encouraged heater bypassing. Party forensic testing revealed that the cracking
This resulted in sub-optimal fluidization inside was caused by caustic deposition resulting from
the heater bundles, inhibiting heat transfer excursions in boiler feed water quality. This
performance. kind of failure has been thoroughly inspected at
Norampac with negative results.
Bed Removal – TRI specified bed removal from
the bottom of the vessel to preferentially extract The PC heater refractory at Norampac has
bed solids that had passed through the char continued to perform well over the past three
conversion zone and any oversize particles that years of operation. However, GP experienced
have settled to the bottom. Norampac has had failures after very short duration runs. After
relatively good experience with the TRI- testing several different refractory materials, it
specified removal of the bed through three lock was eventually determined that the refractory
hoppers in the bottom of the vessel. GP’s was over heating because of maldistribution of
engineer elected to remove the bed material from combustion air, resulting from the air intake
the side of the vessel via a single lock hopper, being much smaller than recommended; the
near the first pulse heater, and directly above the velocity profile entering the heater was too high.
liquor injection zone. Extracting bed material at By designing and installing a distributor to
this point not only allows short circuiting and improve combustion air distribution to the
reduced residence time, but also disrupts the wall aerovalves, the combustion chamber
effect and changes material flow patterns in the temperatures cooled and became more uniform
vessel. The effects of this disruption could be resulting in dramatically improved refractory
detected in the heater bundle temperature life.
measurements. Over an extended period of
operation, larger particles would accumulate at Summary
the bottom of the reformer and when they built It is regrettable that GP chose not to continue the
up to the level above the steam grid, the bed project, especially in light of Norampac’s
fluidization would be compromised. GP success. This outcome reinforces the need for
installed a manual intermittent single lock close collaboration between the technology
hopper system at the bottom of the reformer to supplier and the owner in the early stages of
address this but stopped using it for safety project development for new technologies.
concerns. TRI’s long term partnership with Norampac will
result in continued improvement of the
technology.