Vous êtes sur la page 1sur 44

AGS-20 IDU

TDM/PACKET equipment
Up to 2048 QAM
Adaptive Code Modulation
Enhanced Ethernet Features
Installation, Configuration and Commissioning
Guideline for

Issued by Approved by Date Page


Guideline Installations, Configurations and Commissioning EKO BAYU 11/12/17 1 of 44
44
Property of
Rev.01
Siae Microelettronica.
All rights reserved
Contents
1. REFERENCE DOCUMENT .................................................................................. 4
2. INSTALLATION ............................................................................................. 4
2.1 AGS-20 Indoor Unit ....................................................................................... 4
2.2 ASNK Outdoor Unit ....................................................................................... 8
3. CONNECTION TO AGS-20 ................................................................................ 10
3.1 Connection via LAN 3 AGS-20 with ASNK ODU Sub Band High..................................... 11
3.2 Connection via LAN 3 AGS-20 with ASNK ODU Sub Band Low ..................................... 12
3.3 Connection via LCT port AGS-20 ...................................................................... 14
3.4 Connection via Console port AGS-20.................................................................. 15
4. AGS-20 MICROWAVE LINK LINE UP ..................................................................... 17
4.1 Delete the Default Radio Link ......................................................................... 17
4.2 1+0 Radio Link ........................................................................................... 18
4.2.1 Create a 1+0 Radio Link ............................................................................................ 19
4.2.2 Radio Parameters Configurations ................................................................................. 20
4.2.3 Channel Duplex Frequency Configuration ....................................................................... 21
4.2.4 Transmitter Frequency.............................................................................................. 21
4.2.5 Set the Transmitter Power ......................................................................................... 22

5. DCN/IP ADDRESS CONFIGURATION..................................................................... 23


5.1 Modify the Equipment ID and Agent IP Address ..................................................... 24
5.2 Create VLAN for Management (only for In Band) ................................................... 25
5.3 Modify DCN LAN 3 Parameters......................................................................... 26
5.4 Modify the Remote Element List ...................................................................... 27
5.4.1 Rename Station ...................................................................................................... 27
5.4.2 Remove Equipment List............................................................................................. 28
5.4.3 Add new Equipment List ............................................................................................ 29
5.5 Restart the Equipment ................................................................................. 31
5.6 LAN 3 Port Priority. ..................................................................................... 32
6. CREATE USERS MANAGMENT ............................................................................ 32
7. VIRTUAL LAN (VLAN) CONFIGURATION ................................................................ 35
8. ETHERNET PORT CONFIGURATION ..................................................................... 39
8.1 Enable/Disable Port..................................................................................... 39
8.2 Modify LAN1/LAN2 Interface Type .................................................................... 39
8.3 Change MTU .............................................................................................. 39
Issued by Approved by Date Page
Guideline Installations, Configurations and Commissioning EKO BAYU 11/12/17 2 of 44
44
Property of
Rev.01
Siae Microelettronica.
All rights reserved
9. QOS SETTING.............................................................................................. 41
10. ACM CONFIGURATION .................................................................................. 41
10.1 Enable the ACM Engine. ................................................................................ 42
10.2 Modify the Upper and Lower Modulation ............................................................ 43
11. REVISION RELEASE NOTE ............................................................................... 44

Issued by Approved by Date Page


Guideline Installations, Configurations and Commissioning EKO BAYU 11/12/17 3 of 44
44
Property of
Rev.01
Siae Microelettronica.
All rights reserved
1. REFERENCE DOCUMENT

No DOCUMENT NAME

1 mn00329e rev012 - AGS20 User Manual

2 mn00327erev010 - AGS-20 WebLCT Manual

2. INSTALLATION

Purpose of this document is to be use as reference to install, configure and commission AGS-20 in Indosat Ooredoo
network.

2.1 AGS-20 Indoor Unit

17

22 21 19 15 13
18 11 9 6 4 1

14 12 10 7 5 3 2
23 20 16

1. Power Supply - 48Vdc ±15% (decoupled). 12. LAN 3 - RJ45 Management


2. Power On LED 13. LAN 1 – RJ45
3. Power supply Fuse 14. LAN 2 – RJ45
4. Console (RS232) 15. LAN 2 – SFP Optical
5. User Alarm (RJ45) 16. LAN 1 – SFP Optical
6. Sync (2MHz or 2Mb clock) 17. LCT – RJ45
7. PTP -1588v2 - Time Of Day 18. LAN D - SFP optical or electrical
8. Pulse Per Second (Siemens 1.0/2.3) 19. LAN C - SFP optical or electrical
9. LAN 6 - SFP optical or electrical interface 1 Gbps, 20. Slot SDHC (up to 32GByte)
SFP optical interface 2.5 Gbps (proprietary) 21. ODU B - 50 Ohm interconnection (IF Cable)
10. LAN 5 - SFP optical or electrical interface 1 Gbps, 22. ODU A - 50 Ohm interconnection (IF Cable)
SFP optical interface 2.5 Gbps (proprietary) 23. LED’s
11. LAN 4 - RJ45

Issued by Approved by Date Page


Guideline Installations, Configurations and Commissioning EKO BAYU 11/12/17 4 of 44
44
Property of
Rev.01
Siae Microelettronica.
All rights reserved
AGS-20 installation to the rack

AGS-20 Power Supply -48Vdc

Issued by Approved by Date Page


Guideline Installations, Configurations and Commissioning EKO BAYU 11/12/17 5 of 44
44
Property of
Rev.01
Siae Microelettronica.
All rights reserved
AGS-20 Grounding

AGS-20 IF Cables Connection

Issued by Approved by Date Page


Guideline Installations, Configurations and Commissioning EKO BAYU 11/12/17 6 of 44
44
Property of
Rev.01
Siae Microelettronica.
All rights reserved
Typical Connection

Issued by Approved by Date Page


Guideline Installations, Configurations and Commissioning EKO BAYU 11/12/17 7 of 44
44
Property of
Rev.01
Siae Microelettronica.
All rights reserved
2.2 ASNK Outdoor Unit

Issued by Approved by Date Page


Guideline Installations, Configurations and Commissioning EKO BAYU 11/12/17 8 of 44
44
Property of
Rev.01
Siae Microelettronica.
All rights reserved
2.3 ODU Mounting

Integrated Antenna
STANDARD POLE MOUNTING KIT

1+0 1+1

Not Integrated Antenna


STANDARD POLE MOUNTING KIT

1+0 1+1

For more details related to hardware installations please refer to mn00329e rev012.pdf

Issued by Approved by Date Page


Guideline Installations, Configurations and Commissioning EKO BAYU 11/12/17 9 of 44
44
Property of
Rev.01
Siae Microelettronica.
All rights reserved
3. CONNECTION TO AGS-20

This section describe a step by step procedure to establish a connection to AGS-20 with factory default
configurations.
Needs instrument:
 Personnel Computer (Laptop) installed with internet browser (Internet Explorer 9 or later, Firefox 4.0 or
later).
 RJ45/LAN Cable
 Serial Console Cable
All AGS-20 coming from factory comes with a default configurations. Ethernet connection between PC and AGS-20
can occur if both the IP Addresses belong to the same subnet.
The Ethernet ports available for the management of AGS-20:

• RJ45 LCT port with IP address 192.168.0.1 and netmask 255.255.255.0 (default settings)
• RJ45 LAN3 port with default address is
- 172.20.255.15 and netmask 255.255.0.0 if the IDU has been tested with an ASNK ODU Sub Band High.
- 172.20.254.14 and netmask 255.255.0.0 if the IDU has been tested with an ASNK ODU Sub Band Low.
When the connection is active the WebLCT is available in order to configure and manage unit and link. Through
the same ports, using HyperTerminal, a CLI session can be used to configure the Ethernet switch of the unit. The
maximum number of CLI sessions, active at the same time, is 7. The maximum number of WebLCT sessions active
at the same time is 4.
Connection using LAN 3 will allow users to access the AGS-20 web interface. From LAN 3 its feasible to access
Local and Remote AGS-20.
Connection using LCT port with default AGS-20 configuration will only allow user to access web interface of Local
AGS-20.
Connection using Console (RS323) port via serial cables will only allow users for access AGS-20 to Command Line
Interface (CLI).

Figure 1 AGS-20 Port for Management

Issued by Approved by Date Page


Guideline Installations, Configurations and Commissioning EKO BAYU 11/12/17 10 of 44
44
Property of
Rev.01
Siae Microelettronica.
All rights reserved
3.1 Connection via LAN 3 AGS-20 with ASNK ODU Sub Band High
Steps below describe how to connect and access AGS-20 when it’s connect to an ASNK ODU Sub Band High with a
default configurations.

1. Connect the LAN cable to a PC and LAN 3 port of AGS-20.


2. Configure PC IP Address in same subnet of LAN 3 of AGS-20. Example as below:

3. Open Command Prompt and ping the default IP address of LAN 3 172.20.255.15

4. Open a browser (IE 9 or Firefox)


5. Type in the search bar the AGS-20 IP address 172.20.255.15 and hit “enter” at keyboard.

Issued by Approved by Date Page


Guideline Installations, Configurations and Commissioning EKO BAYU 11/12/17 11 of 44
44
Property of
Rev.01
Siae Microelettronica.
All rights reserved
6. In the WebLCT Login page, write:
 username: admin
 password: admin
7. Select or not the “Remember me” option to remind login data for further accesses.
8. Click Login button.

3.2 Connection via LAN 3 AGS-20 with ASNK ODU Sub Band Low
Steps below describe how to connect and access AGS-20 when it’s connect to an ASNK ODU Sub Band Low with a
default configurations.

1. Connect the LAN cable to a PC and LAN 3 port of AGS-20.


2. Configure PC IP Address in same subnet of LAN 3 of AGS-20. Example as below:

Issued by Approved by Date Page


Guideline Installations, Configurations and Commissioning EKO BAYU 11/12/17 12 of 44
44
Property of
Rev.01
Siae Microelettronica.
All rights reserved
3. Open Command Prompt and ping the default IP address of LAN 3 172.20.254.14

4. Open a browser (IE 9 or Firefox)


5. Type in the search bar the AGS-20 IP address 172.20.254.14 and hit “enter” at keyboard.

6. In the WebLCT Login page, write:


 username: admin
 password: admin
7. Select or not the “Remember me” option to remind login data for further accesses.
8. Click Login button.

Issued by Approved by Date Page


Guideline Installations, Configurations and Commissioning EKO BAYU 11/12/17 13 of 44
44
Property of
Rev.01
Siae Microelettronica.
All rights reserved
3.3 Connection via LCT port AGS-20
Steps below describe how to connect and access AGS-20 via LCT port with default configurations.

1. Connect the LAN cable to a PC and LCT port of AGS-20.


2. Configure PC IP Address in same subnet of LCT of AGS-20. Example as below:

3. Open Command Prompt and ping the default IP address of LCT 192.168.0.1

4. Open a browser (IE 9 or Firefox)


5. Type in the search bar the AGS-20 IP address 192.168.0.1 and hit “enter” at keyboard.

Issued by Approved by Date Page


Guideline Installations, Configurations and Commissioning EKO BAYU 11/12/17 14 of 44
44
Property of
Rev.01
Siae Microelettronica.
All rights reserved
6. In the WebLCT Login page, write:
 username: admin
 password: admin
7. Select or not the “Remember me” option to remind login data for further accesses.
8. Click Login button.

3.4 Connection via Console port AGS-20


Console port is a serial connection with RJ45 connector for console access (only for Command Line Interface).
Serial connection parameters 115200 bps 8-N-1-N. With HyperTerminal software or putty it feasible to access the
Console port of AGS-20. In this section show the connection usig putty.

1. Connect the Serial RJ45 console cables to a PC and Console port of AGS-20.
2. Configure Putty connection parameter as example below:

Issued by Approved by Date Page


Guideline Installations, Configurations and Commissioning EKO BAYU 11/12/17 15 of 44
44
Property of
Rev.01
Siae Microelettronica.
All rights reserved
3. Click “Open” button to open console section
4. At the prompt SM-OS login: write admin
5. At the prompt Password: write admin

6. Push Enter to have the prompt SM-OS#

Issued by Approved by Date Page


Guideline Installations, Configurations and Commissioning EKO BAYU 11/12/17 16 of 44
44
Property of
Rev.01
Siae Microelettronica.
All rights reserved
4. AGS-20 MICROWAVE LINK LINE UP
This section describe a step by step procedure to configure AGS-20 line up. All configuration in this section need
to refers to the link design document (link budget).
The configurations need to be done with a PC connected to LAN 3 of AGS-20.

4.1 Delete the Default Radio Link

WARNING Operation available if at least one Radio Link is defined.


A Link whose port is aggregated cannot be deleted. To perform the operation, it is first necessary to delete
the aggregation (see Delete the aggregation of the Radio ports).
1. Select Equipment > Radio Configurator.
2. Select Delete a Link and press Next>.

3. Select ( ), in the Select Link to Delete table, the Radio Link(s) you want to delete.

Issued by Approved by Date Page


Guideline Installations, Configurations and Commissioning EKO BAYU 11/12/17 17 of 44
44
Property of
Rev.01
Siae Microelettronica.
All rights reserved
4. Press Done.
The Radio Link is removed from the table Current Radio Configuration

4.2 1+0 Radio Link

WARNING Operation not available if all the Radio ports have been already used for other Links. This operation
allows defining Radio Links with native configuration (1+0, 2x(1+0), 2+0 XPIC).
In order to define a system radio configuration, it is necessary to create two or more Radio Links in native
configuration and, possibly, aggregate them.
The system radio configuration allowed for each type of AGS-20 Dual IF are indicated in Table 1.

Table 1 AGS-20 Dual IF Radio Link Configurations

Figure 2 1+0 Radio Link


In 1+0 configuration, only ODU A are used to connect to ODU with Vertical or Horizontal Polarization.
Refer to Link Budget.
Issued by Approved by Date Page
Guideline Installations, Configurations and Commissioning EKO BAYU 11/12/17 18 of 44
44
Property of
Rev.01
Siae Microelettronica.
All rights reserved
4.2.1 Create a 1+0 Radio Link
1. Select Equipment > Radio Configurator.
2. Select Create New Link and press Next>.

3. Set, in the Select Link Type box, the Radio Link type: 1+0

4. Set, in the Link Name box, the site ID of the Remote Link. Example 14BYL028.
5. In the table Available Radio, select the wished ODU’s according to the set type of Radio Link.
• 1+0, select an ODU A
6. Press: Next>, to set the radio parameters of the Link.

Issued by Approved by Date Page


Guideline Installations, Configurations and Commissioning EKO BAYU 11/12/17 19 of 44
44
Property of
Rev.01
Siae Microelettronica.
All rights reserved
4.2.2 Radio Parameters Configurations

1. Set, in the Bandwidth box la reference band (refer to Link Budget).


2. Set, in the Modulation box, the reference modulation (refer to Link Budget).

3.Press: Next>, to set the duplex frequency of the Link.

Issued by Approved by Date Page


Guideline Installations, Configurations and Commissioning EKO BAYU 11/12/17 20 of 44
44
Property of
Rev.01
Siae Microelettronica.
All rights reserved
4.2.3 Channel Duplex Frequency Configuration
1.Set, in the Duplex Frequency Selection table, the duplex frequency (MHz) for the available ODU’s.

2.Press Next>. to set the Transmitter Frequency.

4.2.4 Transmitter Frequency


1.Set, in the Frequency (MHz) Selection table, the transmitter frequency (MHz) for the available ODU’s.
Always refer to Link Budget for frequency need to be use.

2.Press Done. A 1+0 Radio Link will be created with selected parameters.

Issued by Approved by Date Page


Guideline Installations, Configurations and Commissioning EKO BAYU 11/12/17 21 of 44
44
Property of
Rev.01
Siae Microelettronica.
All rights reserved
4.2.5 Set the Transmitter Power
WARNING Asymmetrical configuration of the Radio Link between local and remote equipment, as regards
the value of Ptx / modulation, are not supported.
1. Select Radio > Radio Branch <link name> [ODU A].
2. Select the ODU Powers tab.
The Max Ptx: <current value> dBm parameter indicates the maximum output power value at the
transmitter(Ptx nominal value).

3. To change the parameter, move the cursor on the wished value (refer to Link Budget).
4. Press Apply and confirm.
Repeat the steps for Local/Remote station and perform antenna alignment to get the expected received signal as
in Link Budget.
Proceed as follows:
 Connect a multimeter to BNC connector on the ODU for AGC measurement.
 Adjust antenna pointing as soon as the maximum AGC voltage value is achieved.
The relationship between AGC voltage and received field is shown in Figure 3 and S/N Measurement value as
Table 2. The received field level has a tolerance of ±4 dB in the full temperature range.

Figure 3 Detected voltage vs RF Signal

Issued by Approved by Date Page


Guideline Installations, Configurations and Commissioning EKO BAYU 11/12/17 22 of 44
44
Property of
Rev.01
Siae Microelettronica.
All rights reserved
Minimum S/N values at RX nominal level (-25dBm ÷ -40dBm)
Bandwidth
Modulation
7MHz 14MHz 28MHz 40MHz 56MHz
4QAM st 25 25 25 25 25
4QAM 25 25 25 25 25
16QAM 29 29 29 29 29
32QAM 33 33 33 33 33
64QAM 35 35 35 35 35
128QAM 35 35 35 35 35
256QAM 35.5 35.5 35.5 35.5 35.5
512QAM 38.5 38.5 38 38 38
1024QAM 38 39 39 38.5 38.5
2048QAM 38.5 38.5 38 38

Table 2 Signal to Noise Ratio

5. DCN/IP ADDRESS CONFIGURATION


Data Communication Network (DCN) configuration need to be configure on each installed equipment’s to an IP
address which assign to it. All default configuration must be change with the new parameters given.
AGS-20 can be connected to DCN network using LAN 3 (Out of Band) or In Band using traffic LAN interface (LAN 1
or LAN 2or LAN 4 or LAN 5 or LAN 6 or LAN C or LAN D).
Below are possible network In Band scenario as below:

Figure 4 In Band Scenario with Other Microwave Vendors

Issued by Approved by Date Page


Guideline Installations, Configurations and Commissioning EKO BAYU 11/12/17 23 of 44
44
Property of
Rev.01
Siae Microelettronica.
All rights reserved
Figure 5 In Band Scenario with MetroE

Both Management and traffics share the same LAN interface to connect to the network with a specific VLAN
introduce for management.
WARNING Modification of parameters related to DCN/IP address configuration MUST be perform after antenna
alignment process successfully completed. Modification of Remote Station parameters will be configure first
before proceeding with Local Station.

5.1 Modify the Equipment ID and Agent IP Address

1. Select Main > Equipment Properties.


2. In the Equipment ID field set an alphanumeric string with minimum 1 and maximum 50 characters.
Naming conventions are SITE ID-SITE NAME-IDU(Number). Example 14BYL020-BANYUDONO-IDU1
3. In the Agent IP Address box type the new IP address (refer to Link Design).

4. Press Apply and confirm.


Issued by Approved by Date Page
Guideline Installations, Configurations and Commissioning EKO BAYU 11/12/17 24 of 44
44
Property of
Rev.01
Siae Microelettronica.
All rights reserved
5.2 Create VLAN for Management (only for In Band)
For AGS-20 using In Band Management VLAN ID for management will be use.
1. Select Base Band > Ethernet > VLAN.
2. Select the Static VLANs tab.
3. Press Add.

4. Set, in the box VLAN ID , the identifier (between 2 and 4094) of the Management VLAN will be use. Refer
to Link Design.

5. Set, in the box VLAN Name as MNGT which represent the management VLAN.
6. Select in the box Member Ports the LAN ports to map the VLAN. For In Band configurations, LAN 3 and
ODU A need to be selected.
For AGS-20 which connected to MetroE or other vendors microwave equipment’s this LAN ports also need to
be a member ports of MNGT VLAN.
7. Select in the box Untagged Ports LAN 3.
8. Press Apply and confirm.
Issued by Approved by Date Page
Guideline Installations, Configurations and Commissioning EKO BAYU 11/12/17 25 of 44
44
Property of
Rev.01
Siae Microelettronica.
All rights reserved
The Static VLANs tab displays the row relevant to the new VLAN.

5.3 Modify DCN LAN 3 Parameters

1. Select Base Band > DCN > MNGT Port Configuration.


2. In the IP Address box, set the IP address of the management port. Value = Agent IP Address.

Issued by Approved by Date Page


Guideline Installations, Configurations and Commissioning EKO BAYU 11/12/17 26 of 44
44
Property of
Rev.01
Siae Microelettronica.
All rights reserved
3. In the Net Mask box, set the mask for the network address definition.
4. In the VLAN ID box, select the VLAN ID assigned for management (Example: 33).
5. In the Default Gateway box, set the default gateway IP address (refer Link Design).
6. In the section Physical Interface, Port Alarm Report box select Disable.
7. Press Apply and confirm.
8. Press Store and confirm.

5.4 Modify the Remote Element List

When the WEB page is opened, the Remote elements list area is hidden.
Press to hide the area. Press to display the area again.

5.4.1 Rename Station


1. In the Remote elements list area, select the station to be renamed.
2. Press Rename.

Issued by Approved by Date Page


Guideline Installations, Configurations and Commissioning EKO BAYU 11/12/17 27 of 44
44
Property of
Rev.01
Siae Microelettronica.
All rights reserved
3. Type, into the text box, the new name (alphanumeric string with minimum 1 and maximum 11
characters).

14BYL028

Naming conventions are link ID. Example 14BYL028

4. Press OK.
The application displays the new name of the station into the Remote elements list area.

5.4.2 Remove Equipment List

1. In the Remote elements list area, select the equipment to be removed.


2. Select Equipment 1 and Press Remove.

14BYL028

The application removes the station from the Remote elements list area.
3. Select Equipment 2 and Press Remove.

14BYL028

Issued by Approved by Date Page


Guideline Installations, Configurations and Commissioning EKO BAYU 11/12/17 28 of 44
44
Property of
Rev.01
Siae Microelettronica.
All rights reserved
The program remove the equipments from Station.

14BYL028

5.4.3 Add new Equipment List

1. In the Remote elements list area, select the station to which the equipment has to be coupled.
2. Press Add (Element group).

14BYL028

3. Into the IP Address box, type the IP address of the Local equipment.

4. Set the Type of element box, selecting the option Managed By SCT for Local Equipment.
5. Press Ok.

Issued by Approved by Date Page


Guideline Installations, Configurations and Commissioning EKO BAYU 11/12/17 29 of 44
44
Property of
Rev.01
Siae Microelettronica.
All rights reserved
14BYL028

The program will add Equipment 1 in the Station.


6. Press Add (Element group).
7. Into the IP Address box, type the IP address of the Remote equipment.

8. Set the Type of element box, selecting the option Managed By SCT for Local Equipment.
9. Press Ok.

14BYL028

10. Press Apply and confirm


11. Press to hide Remote elements list

Issued by Approved by Date Page


Guideline Installations, Configurations and Commissioning EKO BAYU 11/12/17 30 of 44
44
Property of
Rev.01
Siae Microelettronica.
All rights reserved
5.5 Restart the Equipment
An equipment restart need to be done to in order to change to the DCN/IP address parameters sets.
Ensure all parameters are correct before performs a restart.
1. Select Base Band > DCN > MNGT Port Configuration.

2. Press Restart and confirm.


Once the equipment’s complete the restart, configure PC IP Address to the same subnet of equipment IP Address.
Connect PC LAN to LAN 3 of equipment. Perform the Ping test to verify the connection between Local and Remote
Equipment’s. Once connectivity is available open an internet browser and insert the new IP address to search bar.
Insert the user name : admin and password : admin to access to WebLCT interface. Click Open Far End to open the
WebLCT interface of Remote equipment and insert the user name : admin, password : admin.

Issued by Approved by Date Page


Guideline Installations, Configurations and Commissioning EKO BAYU 11/12/17 31 of 44
44
Property of
Rev.01
Siae Microelettronica.
All rights reserved
5.6 LAN 3 Port Priority.

1. Select Base Band > Ethernet > VLAN.


2. Select the Port Settings tab.
3. In the Default User Priority box, set a value between 7 for LAN 3.

4. Press Apply and confirm


Perform at Local and Remote equipment’s.

6. CREATE USERS MANAGEMENT

Users management allow to add more Users with different profile to access AGS-20. Each Users must associate to
a Group. All AGS-20 coming from factory comes with a default Users. Below are the default User available from
factory settings.
Users Password Group Profile CLI HTTP HTTPS SNMP FTP SFTP SSH
root admin123 Root Administrator 
admin admin Admin Administrator   SNMPv1 
Table 3 Default Users
An additional Users need to be created as below:
Users Password Group Profile CLI HTTP HTTPS SNMP FTP SFTP SSH
NMS5UX SIAEMICR Admin Administrator   SNMPv1 
Table 4 New Users

WARNING It is possible to set a maximum of 10 groups. Logging as user admin to create new Group and User.

Issued by Approved by Date Page


Guideline Installations, Configurations and Commissioning EKO BAYU 11/12/17 32 of 44
44
Property of
Rev.01
Siae Microelettronica.
All rights reserved
1. Select Main > Group/User Management > Users.
2. Select Add User.

3. Into the User box, type the user name NMS5UX. The parameter is Case Sensitive; pay attention to used
uppercase characters.

Issued by Approved by Date Page


Guideline Installations, Configurations and Commissioning EKO BAYU 11/12/17 33 of 44
44
Property of
Rev.01
Siae Microelettronica.
All rights reserved
4. Press Change at the side of the Password parameter.

SIAEMICR
SIAEMICR

5. Into the New Password and Confirm New Password box, SIAEMICR and press OK. The parameter is Case
Sensitive; pay attention to used uppercase characters.
6. Set the group, to Admin, in the Group box.

7. In the Timeout box, set the timeout of the WEB LCT session opened by the user to 3600 sec.
8. Press OK and confirm.

Issued by Approved by Date Page


Guideline Installations, Configurations and Commissioning EKO BAYU 11/12/17 34 of 44
44
Property of
Rev.01
Siae Microelettronica.
All rights reserved
7. VIRTUAL LAN (VLAN) CONFIGURATION

CELCOM network work in customer bridge configurations which require each Virtual Lan ID (VLAN) need to be
register into Static VLAN Tables. Each traffic need to come with VLAN (802.1q) tagged frames.

1. Select Base Band > Ethernet > VLAN.


2. Select the Static VLANs tab.

3. Press Add.

4. If you wish to create:


 More VLAN’s at the same time, expand the area Group Add. Set, in the box VLAN ID Start, the identifier
(between 2 and 4094) of the first VLAN of the range. Set, in the box VLAN ID Stop, the identifier of the
last VLAN of the range.

Issued by Approved by Date Page


Guideline Installations, Configurations and Commissioning EKO BAYU 11/12/17 35 of 44
44
Property of
Rev.01
Siae Microelettronica.
All rights reserved
The value of VLAN ID Stop must be greater than the value of VLAN ID Start and no VLAN with identifier
between Start and Stop values must not be present in the list.
The system creates a number of VLAN’s (and inserts the corresponding rows in the table) equal to the
difference between the values of the parameters VLAN ID Stop and VLAN ID Start, with progressive identifiers
from the lowest value to the highest value, and automatically assigns the corresponding VLAN Name using the
format <Label> <identifier>.
All the VLAN’s created automatically assume the same enabling policy for the transit of packets through the
ports of the Switch. The system guarantees the contemporary creation of maximum 100 VLANs.

 A single VLAN, set, in the box VLAN ID, the identifier (between 2 and 4094) you wish to assign to the virtual
LAN. An identifier greater than that indicated in the field Max. VLAN ID cannot be used. Set, in the box
VLAN Name, the name (alphanumeric string, 32 characters at most) you wish to assign to the VLAN.
The system automatically suggests, as VLAN name, VLAN <identifier>. This name can be changed as you wish.

1. Activate ( ), in the box Member Ports, the ports enabled to the transit of packets with VLAN ID equal
to the VLAN’s one. For every port are indicated the port identifier (slot number/port number), the port
name LAN 1, LAN 2, LAN4 , LAN 5, LAN 6, LAN C, LAN D and ODUA. LAN3 only used for management
VLAN.

Issued by Approved by Date Page


Guideline Installations, Configurations and Commissioning EKO BAYU 11/12/17 36 of 44
44
Property of
Rev.01
Siae Microelettronica.
All rights reserved
Issued by Approved by Date Page
Guideline Installations, Configurations and Commissioning EKO BAYU 11/12/17 37 of 44
44
Property of
Rev.01
Siae Microelettronica.
All rights reserved
2. Press Apply and confirm.

The Static VLANs tab displays the row relevant to the new VLAN.

Issued by Approved by Date Page


Guideline Installations, Configurations and Commissioning EKO BAYU 11/12/17 38 of 44
44
Property of
Rev.01
Siae Microelettronica.
All rights reserved
8. ETHERNET PORT CONFIGURATION

8.1 Enable/Disable Port


1. Select Base Band > Ethernet > Port Manager.
2. In the Admin State box, select the option:
• Disabled. The port is not enabled to use: the port does not transmit/receive traffic.
• Enabled. The port is enabled to use: the port transmits/receives traffic.

The port cannot transmit/receive traffic if the physical connection does not work (Link Status -Down).
3. Press Apply and confirm

8.2 Modify LAN1/LAN2 Interface Type

WARNING Operation available and meaningful only for the ports supporting both the Electrical and the Optical
interface LAN 1 and LAN2. This operation involves the re-configuration of the port parameters Auto Neg. and MTU
to the default value.
1. Select Base Band > Ethernet > Port Manager.
2. In the Media box, select the option:

• Combo (Copper). Ethernet port with electrical interface.


• Combo (Fiber). Ethernet port with optical interface.
3. Press Apply and confirm.

Issued by Approved by Date Page


Guideline Installations, Configurations and Commissioning EKO BAYU 11/12/17 39 of 44
44
Property of
Rev.01
Siae Microelettronica.
All rights reserved
8.3 Change MTU

1. Open Putty software

2. Login to the equipment

3. Press Open
4. Login: admin
Password: admin

Issued by Approved by Date Page


Guideline Installations, Configurations and Commissioning EKO BAYU 11/12/17 40 of 44
44
Property of
Rev.01
Siae Microelettronica.
All rights reserved
5. Run this script :
configure terminal
system mtu 2048
exit
exit

Check MTU should have changed to 2048

9. QOS SETTING

1. Select Base Band > Ethernet > QoS > Egress.


2. In the Media box, select the option:

3. Press Apply and confirm.

Issued by Approved by Date Page


Guideline Installations, Configurations and Commissioning EKO BAYU 11/12/17 41 of 44
44
Property of
Rev.01
Siae Microelettronica.
All rights reserved
10. ACM CONFIGURATION

10.1 Enable the ACM Engine.

1. Select Equipment > BW & Mod./Link ID.


The ACM Engine parameter indicates the operating status of the adaptive modulation.
WARNING If the Reference Modulation at 2048 QAM or 1024 QAM(for XPIC), ACM will be Disable.

2. To change the parameter, select the option:


• Disabled. Adaptive modulation disabled.
• Enabled. Adaptive modulation enabled.

3. Press Apply and confirm.

Issued by Approved by Date Page


Guideline Installations, Configurations and Commissioning EKO BAYU 11/12/17 42 of 44
44
Property of
Rev.01
Siae Microelettronica.
All rights reserved
10.2 Modify the Upper and Lower Modulation

WARNING Operation available only if the adaptive modulation is enabled.

1. Select Equipment > BW & Mod./Link ID.


The Upper Profile and Lower Profile parameters respectively indicates the upper threshold and the lower
threshold of the ACM profile (code and modulation).
2. To change the parameters Upper Profile and Lower Profile, select the value relevant to the wished
modulation.

 Upper Profile = 2048 QAM or 1024 QAM (for XPIC)


 Lower Profile = Reference Modulation
3. Press Apply and confirm.

Issued by Approved by Date Page


Guideline Installations, Configurations and Commissioning EKO BAYU 11/12/17 43 of 44
44
Property of
Rev.01
Siae Microelettronica.
All rights reserved
11. REVISION RELEASE NOTE

Version Date Description Owner


1.0 11/12/2017 Initial Version Eko Bayu P

Issued by Approved by Date Page


Guideline Installations, Configurations and Commissioning EKO BAYU 11/12/17 44 of 44
44
Property of
Rev.01
Siae Microelettronica.
All rights reserved

Vous aimerez peut-être aussi