Ø25
Ø25
31
TL SERIES If a non-set format is selected, the sensor is disabled and the green LED
M12x1
flashes at a low rate.
A setting can be stored selecting a format and executing the procedure
INSTRUCTION MANUAL 18 mm LENS 9 mm LENS 14.1 27.5 28
20.9
described in the “SETTING” paragraph.
When SET is selected (configuration selector section 1), the MARK and
n°.4 M5x6 BKGD pushbuttons are disabled; the REMOTE inputs (TL-x1x) replace
36.6 28 n°.4 M5x0.24 the pushbuttons functionality.
Connecting the REMOTE A and B inputs to the positive power supply
rail is equivalent to pressing the MARK and BKGD pushbuttons
CONTROLS respectively. Connect the unused inputs to 0V.
Ø6.1
42.2
OUTPUT LED READY LED .
OUTPUT LED
TIMING FUNCTION
The red LED indicates the output status.
24
58
When ON is selected ON ON
39.8
READY LED MARK
PUSHBUTTON
BKGD
PUSHBUTTON (configuration selector OUT without TIMER OFF
OFF
During functioning, the green LED permanently ON indicates a normal mm section 2), a delay timer ON ON
operating condition; fast blinking indicates an output overload condition.
4.3
function is enabled which OUT with TIMER 20 ms
OFF 20 ms OFF
See the “SETTING” paragraph for setup procedure indications. extends the minimum ON
MARK / BKGD PUSHBUTTON CAP
output time to 20 ms. The factory setting is OFF (timer disabled).
The pushbutton activates the setup procedure.
TECHNICAL DATA SETTING
INSTALLATION A two-step setup procedure adjusts the switching threshold and the
Power supply: 10 … 30 Vdc limit values; reverse polarity protection LIGHT/DARK mode. Using the procedure given below the sensor output
Operating distance is rated is set to be ON when a mark is detected.
Ripple: 2 Vpp max.
starting from the lens front face.
Current consumption 1) Output ON state acquisition (MARK)
The M12 connector or cable exit 80 mA max.
(output current excluded): Place the target mark into the emission spot and press the MARK
can be rotated in three positions
Output: NPN or PNP, pull down/up resistance 10 k (short-circuit protection) pushbutton until the green LED turns OFF.
by loosening the locking screw.
Output current: 200 mA max. Don’t move the mark during the setting phase (about 1 sec).
Tighten the locking screw when
finished. Analog output: 0 … 2 V ± 10% (white 90%); 5.5 V max.; ripple 40 mVpp max.; output resistance 2.2 k 2) Output OFF state acquisition (BKGD)
The beam direction may be Place the background into the emission spot and press the BKGD
Output saturation voltage: 1V max. NPN versions / 2V max PNP versions
changed swapping the cap and pushbutton; the green LED blinks once.
Response time: 50 s max. / 25 s max. (TL-4xx/5xx) Don’t move the background during the setting phase.
the lens.
Switching frequency: 10 kHz max. / 20 kHz max. (TL-4xx/5xx)
Detecting marks on a reflective surface is improved adjusting the beam
direction to 5° … 20° from surface axis. Timing function: 20 ms minimum output ON If the green LED lights permanently ON, a safe operation has been
Indicators: OUTPUT LED (RED) / READY LED (GREEN) obtained; if it flashes at a low rate the setup procedure has failed due to
CONNECTIONS Setting:
Retention data:
by pushbuttons / by wires; 4 settings storage cable version
non volatile EEPROM memory
insufficient contrast; repeat the procedure from the beginning.
M12 CONNECTOR A double selector and a switch are REMOTE ON TIMING Relative sensitivity
available removing the sensor side %
SET ON TL -x1x/4xx/5xx
ANALOG OUTPUT cover. The selector allows to enable the 100
(WHITE) 2 1 + 10 … 30 Vdc
(BROWN)
output timing function and choose the FORMAT OFF 80
pushbuttons and REMOTE inputs 1 2
60 TL -x6x DATALOGIC AUTOMATION cares for the environment: 100% recycled paper.
DATALOGIC AUTOMATION reserves the right to make modifications and
3 4 operating mode; the switch allows to select the output type (NPN or 40 improvements without prior notification.
0V - NPN/PNP PNP).
(BLUE) (BLACK) 20 Datalogic and the Datalogic logo are registered trademarks of Datalogic
0 S.p.A. in many countries, including the U.S.A. and the E.U.
0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30
Operating distance mm 826000025 Rev.G © Copyright Datalogic 2007-2009