REPORT OF CALCULATION OF FOUNDATION

No Name Section Reinfocement Bar Drawing

ᶲ 500 mm

1 BORE PILE

L 10500 mm

a 1100 mm Bot(a) DB16@110 Top(a) DB14@130

b 1100 mm Bot(b) DB16@140 Top(b) DB14@140


2 PILE CAP PC1

h 1000 mm

Cover 75 mm

a 300 mm Layer1 3DB16

b 300 mm Layer2 2DB16

3 STUMP COLUMN SP1

h 1000 mm Layer3 3DB16


Cover 30 mm
ng
REPORT OF CALCULATION GROUND FLOOR

No Name Section Reinfocement Bar Drawing

a 300 mm Layer1 3DB16

Stirrup Bar

b 300 mm Layer2 2DB16

1 COLUMN C1

h 4680 mm Layer3 3DB16 end RB6@100

Cover 30 mm mid RB6@200

Support span

a 300 mm Layer1 3DB20 Stirrup Bar

b 600 mm Layer2 3DB20

L 6850 mm Layer3 3DB20 end RB8@100

Cover 30 mm mid RB8@150

2 BEAM GB1(300x600)mm
2 BEAM GB1(300x600)mm

Mid span

a 300 mm Layer1 3DB20 Stirrup Bar

b 600 mm Layer2 3DB20

L 6850 mm end RB8@100

Cover 30 mm mid RB8@150

Sopport span

a 300 mm Layer1 3DB14 Stirrup Bar

b 400 mm Layer2 2DB14

L 6000 mm Layer3 3DB14 end RB6@100

Cover 30 mm mid RB6@150

3 BEAM GB2(300x400)mm

Mid span

Stirrup Bar
a 300 mm Layer1 3DB14 Stirrup Bar

b 400 mm Layer2 2DB14

L 6000 mm Layer3 3DB14 end RB6@100

Cover 30 mm mid RB6@150

Sopport span

a 300 mm Layer1 3DB14 Stirrup Bar

b 400 mm Layer2 3DB14

L 4000 mm end RB6@100

Cover 30 mm mid RB6@150

9 BEAM GB2(300x400)mm
9 BEAM GB2(300x400)mm

Mid span

a 300 mm Layer1 3DB14 Stirrup Bar

b 400 mm Layer2 3DB14

L 4000 mm end RB6@100

Cover 30 mm mid RB6@150

a mm bot(a) DB10@150 top(a) DB10@150

b mm bot(b) DB10@150 top(b) DB10@150


STAIRCASE GROUND
11
FLOOR (TH:120mm)
h 120 mm

Cover 25 mm

a 6850 mm bot(a) DB10@200 top(a) DB10@200

b 21020 mm bot(b) DB10@200 top(b) DB10@200


SLAB FIRST FLOOR
10
(TH:120mm)
SLAB FIRST FLOOR
10
(TH:120mm)
h 120 mm

Cover 25 mm
ng