Vous êtes sur la page 1sur 23

Assessment of Electrodialysis Water Desalination Process Costs

H. Strathmann,
Institute of Chemical Engineering,
University of Stuttgart, Germany

Abstract:
Electrodialysis has been one of the first commercially available large scale water
desalination processes based on membranes and is still widely used all over the world. However,
in spite of long term reliable operation experience and clear technical advantages of
electrodialysis in brackish water desalination and waste water treatment the process is replaced
more and more by reverse osmosis and nanofiltration in recent years. The main reason for the
decreasing use of electrodialysis in the production of potable water are the overall process costs.
In this presentation the fundamentals of electrodialysis are briefly described and the various
parameters determining the process costs are analyzed. As result it is shown that in addition to
the investment related costs, energy consumption is the dominating factor determining the
economics of the process.
In electrodialysis both investment as well as the energy costs depend strongly on the feed
water salt concentration. By comparing the costs of various desalination processes the range of
feed and product water concentration, in which electrodialysis has a clear advantage over the
competing processes in terms of the overall costs including pre- and post-treatment procedures,
has been identified. The assessment indicates that electrodialysis can be most effectively used for
the production of potable water from feed waters with concentrations between 1000 to 10 000
ppm total dissolved salts. For sea water desalination electrodialysis can presently not compete in
terms of overall process costs with reverse osmosis.

Key words: Electrodialysis, water desalination, ion-exchange membranes, desalination costs

32
1. Introduction
Electrodialysis has been the first membrane based water desalination process based on
membranes which became commercially available more than 40 years ago and is still widely
used all over the world for the production of potable water from brackish water. The world-wide
installed capacity of electrodialysis plants for brackish water desalination is well in excess of 106
m3 d-1. The majority of these plants is operated in reversed polarity mode which is referred to as
electrodialysis reversal. In water desalination, electrodialysis is competing directly with
distillation, with reverse osmosis and more recently with nano-filtration. However, in a certain
range of feed water salt composition electrodialysis has a clear economic advantage over other
desalination processes. Electrodialysis is mainly used in small to medium size plants with
capacities of less than a few 100 m3 d-1 to more than 20 000 m3 d-1 and brackish water salinity of
1000 to 5000 mg L-1 total dissolved solids. Since in electrodialysis both the energy consumption
and the required membrane area are strongly increasing with increasing feed water concentration
reverse osmosis is considered to have an economic advantage for the desalination of saline water
with total dissolved salts in excess of 10 000 mg L-1. Nevertheless, electrodialysis has been used
successfully to desalinate well water with a total salt concentration of 36 000 mg L-1. The
advantages of electrodialysis compared to reverse osmosis and nanofiltration are:
high water recovery rates even for raw water with high sulfate content,
long useful life of membranes due to higher chemical and mechanical stability,
operation at elevated temperatures up to 50oC possible,
less membrane fouling or scaling due to process reversal,
less raw water pretreatment,
ion-exchange membranes tolerate higher level of chlorine and extreme pH-values,
the process can easily be adjusted to varying feed water quality,
easy start-up and shut-down of the process for intermittent operation.
The desalination of brackish water by electrodialysis has also several disadvantages
compared to reverse osmosis or nanofiltration because neutral toxic components such as viruses
or bacteria are not removed by electrodialysis. Therefore, a post-treatment may be required prior
to the use as potable water. Furthermore, the generation of chlorine gas at the anode can lead to
corrosion problems in the surrounding of the plant if the venting is insufficient. In spite of the
fact that electrodialysis reversal is significantly less sensitive to membrane fouling than reverse
osmosis some pretreatment of the feed water is required to achieve trouble free operation.
Brackish water desalination plants used for the production of potable water can be rather different
in size. Container mounted units with a capacity of 50 to 300 m3d-1 are often used to supply
isolated hotels, small islands or the labor force in camps in isolated dessert areas with potable
water. Larger installations with capacities between 10,000 to 30,000 m3d-1 are used for municipal
water supply or in industrial applications.

2. Electrodialysis Processes Operating Principle and Fundamentals


The principle of electrodialysis is illustrated in Figure 1 which shows a schematic diagram of
a typical electrodialysis cell arrangement consisting of a series of anion- and cation-exchange
membranes arranged in an alternating pattern between an anode and a cathode to form individual
cells. If an ionic solution such as an aqueous salt solution is pumped through these cells and an

33
electrical potential is established between the anode and cathode, the positively charged cations
migrate towards the cathode and the negatively charged anions towards the anode. The cations
pass easily through the negatively charged cation-exchange membrane but are retained by the
positively charged anion-exchange membrane. Likewise, the negatively charged anions pass
through the anion-exchange membrane, and are retained by the cation-exchange membrane. The
overall result is an increase in the ion concentration in alternate compartments, while the other
compartments simultaneously become depleted. The depleted solution is referred to as the diluate
and the concentrated solution as the brine or the concentrate. The driving force for the ion
transport in the electrodialysis process is the applied electrical potential between the anode and
cathode. The total space occupied by the diluate and the concentrated solutions, i.e. the
concentrate and diluate cells, and the contiguous anion- and cation-exchange membranes make
up a cell pair. The cell pair is a repeating unit in an electrodialysis stack. An actual electrodialysis
unit which is referred to as a stack may have a few hundreds of cell pairs. Although there are
many different components necessary for the proper and efficient operation of an electrodialysis
plant such as the electrical power supply, pumps, and control and monitoring devices, the stack is
the key element. There are various stack design concepts described in the literature [1]. In praxis
only two different stack designs are used on a large scale. One is the so-called sheet-flow and the
other the tortuous path-flow concept. Both stack designs will be discussed in more detail later.

cell unit

concentrate diluate concentrate

-
+ - + - + -
+
- -
- + - +
- - + + - - + +
- -
- + - +
anode + - + - + - cathode
- -
- + + -
-
+ - + - +
- - + - - +
- - + + - +
- + - +
- -

feed solution

Fig.1 Schematic diagram illustrating the principle of desalination by electrodialysis in a stack of


cation- and anion-exchange membranes in alternating series.

3. The Ion-Exchange Membranes, their Properties and Structures


Ion-exchange membranes are key properties in electrodialysis. They consist of highly
swollen gel-type polymer structures carrying positive or negative charged groups. Membranes
which contain negatively charged groups fixed to the polymer matrix are referred to as cation-
exchange membranes and those containing positively charged groups are referred to as anion-
exchange membranes. In a cation-exchange membrane, the fixed anions are in electrical

34
equilibrium with mobile cations in the interstices of the polymer, as indicated in Figure 2, which
shows schematically the matrix of a cation-exchange membrane with fixed negative charges and
mobile cations, the latter are referred to as counter-ions. The mobile anions are called co-ions and
are more or less completely excluded from the polymer matrix because of their electrical charge
which is identical to that of the fixed ions. Due to the exclusion of the co-ions, a cation-exchange
membrane is preferentially permeable to cations. Anion-exchange membranes carry positive
charges fixed on the polymer matrix. They therefore exclude cations more or less completely and
are preferentially permeable to anions. To which extent the co-ions are excluded from an ion-
exchange membrane depends on membrane as well as on solution properties. Furthermore,
cation- and anion-exchange membranes are classified as strong acid and strong base or weak acid
and weak base membranes depending on the degree of dissociation of the charged group. Strong
acid membranes contain sulfonic acid as charged groups. In weak acid membranes carboxylic
acid is the charge carrying group. Quaternary and tertiary amines are the fixed charges in strong
and weak base cation-exchange membranes, respectively [2].

+− +− − + − + −
+ −
+ + +
− − −
+ − +
+ − + −+ + −
− − −+
+ + −
+ −
− − +− −
+ + + −
+ −+
− −
+ − + +
− +
− + − −
+ − + − + +

− fixed ions + counter-ions − co-ions

polymer matrix

Fig. 2 Schematic drawing illustrating the structure of a cation-exchange membrane.

The properties of ion-exchange membranes are determined by different parameters, such as


the density of the polymer network, the hydrophobic or hydrophilic character of the matrix
polymer and the type and concentration of the charges in the polymer, and the morphology of the
membrane itself [3]. The most desired properties of ion-exchange membranes are:
High permselectivity
Low electrical resistance
Good mechanical and form stability
High chemical and thermal stability
Many of today's available ion-exchange membranes meet most of these requirements.

35
4. Mass Transfer in Electrodialysis
The mass transfer in electrodialysis is determined by the driving forces acting on the
individual components of the solution and by the friction which the components have to
overcome when being moved in the solution and the ion-exchange membranes. The driving
forces acting on the components of a system can be expressed by gradients in their
electrochemical potential. The friction or the resistance that has to be overcome by the driving
force to achieve the transport of the component can be expressed by a mobility, i.e. a diffusion
coefficient or by the electrical resistance of the electrolyte and the membranes. To describe mass
transport phenomena in electrodialysis the extended Nernst-Planck equation can be applied [4].
dC i z i Ci F d
Ji Di Di vk Ci (1)
dz RT dz
Here J is flux, D is the diffusion coefficient, C is the concentration, j is the electrical
potential, vk is the convective flow, z is the charge number, F is the Faraday constant, R is the gas
constant, and T is the absolute temperature, and dz is a directional coordinate; the subscript i
refers to a component.
The Nernst-Planck equation considers three modes of mass transport: (1) diffusion, (2)
migration, and (3) convection.
dC i
The first term Di in Equation 1 represents the diffusion due to a concentration gradient,
dz
zCF d
the second term Di i i the migration due to an electrical potential gradient, and the third
RT dz
term v k Ci the convection due to a pressure gradient which is less important in electrodialysis
and generally neglected.
The Nernst-Planck flux equation is a very convenient approach to describe the transport of
ions in ion-exchange membranes. It must, however, be realized that a series of assumptions has
been made such as the activity coefficients 1 which in practical ion-exchange membrane
separation processes are not always applicable.

4.1. Electrical Current and Ion Fluxes


In electrodialysis it is assumed that the total current through the membrane is carried by ions
only, thus is:
I
i F zi J i (2)
A i

Here i is the current density, I is the current, A is the membrane surface, F is the Faraday
constant, J is the flux, z is the charge number, and x is a directional coordinate; the subscript i
refers to cations and anions.
The current density i can be related to the specific conductivity by:
d
i (3)
dz

36
Here is the specific conductivity, the electrical potential, and z is the directional
coordinate.
The specific conductivity can be expressed by the specific electrical resistance, the
equivalent conductivity, the ion migration velocity, or the ion diffusivity:
1 Di
z i Ci i F2 z i Ci (4)
i i RT
Here is the specific resistance, C is the concentration, F is the Faraday constant, is the
equivalent conductivity, D is the ion diffusion coefficient, R is the gas constant, T the absolute
temperature, and the subscript i refers to anions and cations.
Introducing the Nernst-Planck Equations into Equation 2 and neglecting the convection term
leads to:
C i Di RT dC i d
i F2 z i2 (5)
i RT z i C i F dz dz
The application of Equations 1 and 5 for determining the ion fluxes or the current in
electrolyte solutions, however, is restricted by the electroneutrality requirement and the
conservation of charges which must be fulfilled on a macroscopic scale at all times. For a system
consisting of a membrane and solutions the electroneutrality condition requires for the solution:
z i Ci 0 (6)
i

and for a membrane:


z i C im z fix C mfix 0 (7)
i

Here the superscript m refers to ions in an ion-exchange membrane, the subscript fix refers to
charges fixed to the membrane matrix, the subscript i refers to cations and anions.

4.2. The Transport Number and Membrane Permselectivity


In an electrolyte solution the current is carried by both ions. However, cations and anions
usually carry different portions of the overall current. In ion-exchange membranes the current is
carried preferentially by the counterions. The fraction of the current that is carried by a certain
ion is expressed by the ion transport number [4] which is given by:
zi J i
Ti (8)
zj Jj
j

Here Ti is the transport number of the component i, Ji is its flux, and zi its valence, the
subscript j refers to all ions involved in the charge transport.
The transport number Ti indicates the fraction of the total current that is carried by the ion i,
the sum of the transport number of all ions in a solution is 1.

37
The membrane permselectivity is an important parameter for determining the performance of
a membrane in a certain ion-exchange membrane separation process. It describes the degree to
which a membrane passes an ion of one charge and retains an ion of the opposite charge. The
permselectivity of cation- and anion-exchange membranes can be defined by the following
relations [3]:

cm Tccm Tc am Taam Ta
and (9)
Ta Tc
Here is the permselectivity of a membrane, T is the transport number, the superscripts cm
and am refer to cation- and anion-exchange membranes, and the subscripts c and a refer to cation
and anion, respectively.
The permselectivity of an ion-exchange membrane relates the transport of electric charges by
a specific counterion to the total transport of electric charges through the membrane and the
transport number of the ion in the solution. An ideal permselective cation-exchange membrane
would transmit positively charged ions only, i.e. for a transport number of a counterion in an
cm
cation-exchange membrane is Tccm = 1 and the permselectivity 1 . The permselectivity
approaches zero when the transport number within the membrane is identical to that in the
electrolyte solution, i.e. for Tccm = Tc is cm 0 . For the anion-exchange membrane holds the
corresponding relation.
The transport number of a certain ion in the membrane is proportional to its concentration in
the membrane which again is a function of its concentration in the solutions in equilibrium with
the membrane phase, due to the Donnan exclusion [3]. For a monovalent salt and a dilute salt
solution and assuming the activity coefficients of the salt in the membrane and the solution to be
1 the co-ion concentration is given to a first approximation by:
s 2
m Cs
C co (10)
C fix
Here C is the concentration, the subscripts co, s and fix refer to co-ion, salt and fixed ion of
the membrane, the superscripts s and m refer to membrane and solution.
Equation 10 indicates that the co-ion concentration in the membrane is decreasing with
increasing salt concentration in the solution and will vanish when the salt concentration in the
solution is identical to the fixed ion concentration of the membrane.

5. Processes Effecting the Efficiency of Electrodialysis


In practical application electrodialysis is effected by concentration polarization, by
incomplete current utilization and by osmotic and electroosmotic water transport through the
membranes. Especially the two first phenomena influence the efficiency of the process.

38
5.1. Concentration Polarization and Limiting Current Density
An electric current passing through an electrodialysis cell pair is carried in the solution by
both cat- and anions according to their transport numbers which are in aqueous solutions not very
different for cat- and anions. In the ion-exchange membranes, however, the current is carried
mainly by the counterions. The differences in the transport numbers of ions in the solution and in
the ion-exchange membranes results in a depletion of counter-ions at the surface of the ion-
exchange membranes facing the diluate solution, and a concentration gradient is established in
the solution between the membrane surface and the well mixed bulk. This concentration gradient
results in a diffusive electrolyte transport. A steady state situation is obtained when the additional
ions that are needed to balance those removed from the interface due to the faster transport rate in
the membrane are supplied by the diffusive transport. The other side of the ion-exchange
membrane is facing the concentrate solution. Here, an accumulation of ions occurs, because more
ions are transferred through the membrane that can be carried away by the electric current due to
the lower transport numbers in the solution than in the membrane. Thus, a concentration gradient
of the salt is established in the solution which results in an additional diffusive salt flux from the
membrane into the solution. The concentration gradients and thus the diffusive flux are limited to
a thin boundary layer at the membrane surface due to turbulent mixing of the bulk solution. The
process of concentration polarization is illustrated in Figure 3 which shows the profiles of the salt
concentration in the solutions near the surface of the cation-exchange membrane under steady
state conditions and the fluxes of salt, cation and anion. In the membranes cations are transported
mainly by migration indicated by J cmig . Anions are more or less completely excluded from the
cation-exchange membrane and their flux through the membrane by migration and diffusion in
opposite direction is very small. It is expressed in the current utilization as will be discussed later.
In the boundary layers at the membrane surfaces both cations and anions are also transported by
migration, however, in opposite directions and thus, generating a concentration gradient leading
to a diffusion of salt J sdiff . In the diluate side of the membrane the diffusive flux is towards the
membrane and at the concentrate side it is towards the bulk solution following the concentration
gradients in the boundary layers. The different fluxes lead to a depletion of salt at the membrane
surface in the diluate solution and an increase of the salt concentration at the membrane surface
in the concentrate solution. In Figure 3 the symbols J and C denote the flux and the concentration, the
superscripts mig and diff refer to migration and diffusion, the superscripts d and c refer to diluate and
concentrate solution, and the superscripts b and m refer to bulk phase and membrane surface, respectively,
the subscripts a and c refer to anion and cation.
Jmig
c
_
_
Jdiff _ Jcmig
s
m Cc _
b c s _
Cs _
_ Jamig
_ anode
cathode _
_
b
Csd
mig
Jc
_
_ Jdiff
s
_
_
mig _
bulk solution Ja _ m d
C bulk solution
s
diff
Js

laminar boundary layer


Fig. 3 Schematic drawing illustrating concentration profiles of a salt in the boundary layer on both sides
of a cation-exchange membrane and the fluxes of cations and anions in the boundary layer, and in the
membrane.

39
The concentration polarization occurring in electrodialysis, i.e. the concentration profiles at
the membrane surface can be calculated by a mass balance taking into account all fluxes in the
boundary layer and the hydrodynamic conditions in the flow channel between the membranes. To
a first approximation, however, concentration polarization phenomena in electrodialysis can be
treated by applying the so-called Nernst film model which assumes that the solution in a cell
between two membranes can be divided into a bulk phase between two laminar boundary layers
at the membrane surfaces. The bulk solution between the laminar boundary layers is well mixed
and has a uniform concentration, whereas the concentration in the boundary layers changes over
the thickness. It is assumed that under steady state conditions in the bulk phase the electrical
potential gradient is the only driving force for the flux of ions in the direction towards the
membranes while in the boundary layer the concentration and electrical potential gradients
perpendicular to the membrane surfaces are causing the mass transport.
A mass balance taking into account the diffusion and migration of ions in the boundary layer
leads to:
i dC id i (11)
J idiff J imig J im Ti m Di Ti s
zi F dz zi F
Here J is the flux, D is the diffusion coefficient, T is the transport number, F is the Faraday
constant, z is the valence, and dz is a directional coordinate, the subscript i refers to cat- or
anions; the superscripts mig and diff refer to ion migration and ion diffusion, respectively, and the
superscripts s, m and d refer to the solution, membrane, and diluate.
Rearranging gives the current through an ion-exchange membrane as a function of the ion
concentration gradient in the solution, i.e. in the boundary layer, the diffusion coefficient in the
solution, and the transference numbers of the ion in the membrane and in the solution:

F Di dC id F Di b
C id m
C id
i (12)
z i Ti m Ti dz z i Ti m Ti z

Here z is the boundary layer thickness, b C id and m C id are the concentrations in the diluate in
the bulk and the membrane surface.
Thus, Equation 12 relates the current density to the concentration gradient in the boundary
layer.

5.2. The Limiting Current Density, Causes and Consequences


The consequences of concentration polarization in electrodialysis are twofold. In the diluate
containing cell the salt concentration at the membrane surface is decreased and in the concentrate
containing cell increased. Both effects impair the technical feasibility and the economics of the
process. When, due to concentration polarization, the salt concentration in the concentrate cell
exceeds the solubility limits of the solution constituents, precipitation of salts occurs. When, due
to concentration polarization, in the diluate containing cell the salt concentration at the membrane
surface is reduced to zero there are no more salt ions available to carry the electric current. Thus,
the voltage drop across the boundary layer increases drastically resulting in a higher energy
consumption and in an electric field enhanced water dissociation. The consequence of the water
dissociation is a loss of current utilization and drastic pH-value shifts, with an increase of the pH-
value at the surface of the anion-exchange membrane in the concentrate containing cell and a
decrease of the pH-value at the surface of the cation-exchange membrane. The increase in the

40
pH-value can lead to a precipitation of multivalent ions on the membrane surface. Thus, in a
practical application of electrodialysis the concentration polarization effects should be minimized
and especially water dissociation should be avoided. For a given cell design diluate concentration
and flow conditions concentration polarization is determined by the current density. When the
hydrodynamic flow conditions are kept constant the current density is limited. This maximum
current density is reached when the salt concentration at the membrane surface in the diluate cell
becomes 0. This current density is referred to as the limiting current density. Thus i = ilim for
m
Cs 0:
b d
FDs Cs
ilim m
(13)
z c Tc Tc z

The limiting current density can be determined by Equation 13 by assuming that the limiting
current density is reached when the salt concentration at the membrane surface in the diluate cell
goes towards zero. Generally the thickness of the laminar boundary layer in an electrodialysis cell
is difficult to measure experimentally. Therefore, in praxis generally an empirically derived
expression is used to describe the limiting current density as a function of the feed flow velocity
in the electrodialysis stack [5]. The limiting current density is expressed by:

i lim a u b C sd (14)
d
Here C s is the concentration of the solution in the diluate cell, u is the linear flow velocity
of the solution through the cells parallel to the membrane surface, and a and b are characteristic
constants for a given stack design and must be determined experimentally. This is done in
practice by measuring the limiting current density in a given stack configuration and constant
feed solution salt concentrations as a function of the feed flow velocity.
Since the laminar boundary layers in a cell are very thin the concentration in the diluate cell is to
a first approximation equal to the bulk concentration. Thus is C sd b
C ds .
The limiting current density can be determined by measuring the current as a function of the
applied voltage across a membrane. The procedure is illustrated in Figure 4 which shows the
current density measured through a cation-exchange membrane.

6
current density [mA cm -2]

5
current density [mA cm-2]

limiting current density


4

0
0 0.2 0.4 0.6 0.8 1 1.2
voltage drop [V] voltage drop [V]

Fig. 4 Experimentally determined current versus voltage curve measured with a cation-exchange
membrane (CMX of Tokuyama Soda) in a 0.05 molar NaCl-solution [5].

41
The slope of the curve is inverse proportional to the electrical resistance of the solutions in
the boundary layers at the membrane surfaces. The current versus voltage curve shows a more
ore less linear increase of the current with an increase of the applied voltage up to a certain
voltage drop and then the slope of the curve decreases drastically because of a drastic increase in
the boundary layer resistance which is result of the depletion of the salt at the membrane surface.
The current at the point is referred to as the limiting current density.
By measuring the limiting current density in a given stack design and diluate concentration
the constants a and b can be determined from the slope of the curve which is obtained by plotting
the limiting current density versus the solution flow velocity.
The measurement of the current versus voltage curve shown in Figure 4. is carried out with a
single membrane in a laboratory type test cell. Measurements in a multi-cell stack often do not
show such a clear indication of the change in the resistance when the limiting current density is
exceeded. Therefore, Cowan and Brown [6] devised another analytical procedure for determining
the limiting current density by plotting the overall resistance versus the reciprocal current density.
Additionally, a change in the pH-value in the diluate solution can be used to determine the
limiting current density. When the limiting current density is exceeded a sharp drop in the pH-
value of the diluate solution is observed.

5.3. The Current Utilization


In any practical electrodialysis process not all of the current flowing through the stack can be
utilized for desalting the feed solution. Several factors may contribute to incomplete current
utilisation in an electrodialysis stack: (1) the membranes are not perfectly selective, (2) there may
be parallel current paths through the stack manifold, (3) there iswater transfer across the
membranes due to osmosis and electroosmosis. The ratio of the salt transported through a
membrane from a feed to a concentrate stream in reality to the theoretical current requirement is
referred to as current efficiency which is given by:
(15)
tot F w ms l w

Here is an efficiency term, and the superscripts tot, F, ms, l, and w refer to total efficiency,
Faraday efficiency, membrane permselectivity, current leakage through the manifold, and water
transport through the membranes. The efficiency terms ms, l, and w are all defined in such a
way that under ideal conditions they approach 1.
The total efficiency is the product of Faraday efficiency which is given by the membrane
selectivity and current leakage through the manifold, and the water transport due to osmosis and
electroosmosis.
The total current utilization in an electrodialysis stack is expressed by the net removal of salt
from a feed volume and the water transport efficiency. It is given by:

cm am

tot l N cell 1 Twam Twcm Vw C sf C sd (16)


2

42
cm am
Here and are the permselectivities and Twcm and Twam the transport numbers of the
cation- and anion membranes, Vw and C sf and C sd are the partial molar volume of water and the
salt concentrations in the feed and diluate.
For relatively dilute feed solutions, i.e. C sf < 0.1 mol L-1, the efficiency loss due to water
transfer is very low, i.e. w 1. However, for higher feed solution salt concentration the water
transfer may effect the efficiency of electrodialysis quite significantly.
The current leakage through the manifold system depends on the difference between the
diluate and concentrate salt concentration and on the stack design. In a well designed stack and
for concentration differences between the concentrate and the diluate of less than a factor of 10
the efficiency loss due to current leakage can be neglected, i.e. l 1.

6. Electrodialysis process design


In addition to the actual stack and the power supply, an electrodialysis plant consists of
several other components essential for a proper operation, such as pumps, process monitoring and
control devices, and feed solution pretreatment equipment. Again, as in the design of the
electrodialysis stack, there are several operating modes for the electrodialysis process. Depending
on the feed solution composition and the product requirements electrodialysis units may be
operated in a batch-type, in a continuous, or in a feed-and-bleed mode with partial recycle of the
diluate and concentrate streams. Independent of the mode of operation there are two basic
concepts of using electrodialysis in large scale applications. The first concept is referred to as the
unidirectional electrodialysis[4] and the second as electrodialysis reversal [7].
In an unidirectional operated electrodialysis stack the electric field is permanently applied in
one direction and the diluate and concentrate cells are also permanently fixed over the period of
operation. Unidirectionally operated electrodialysis plants are rather sensitive to membrane
fouling and scaling and often require a substantial feed solution pre-treatment and stack cleaning
procedures in form of periodical rinsing of the stack with acid or detergent solutions. The
unidirectional operating concept is no longer used in the desalination of brackish waters. Here
generally electrodialysis reversal is applied which allows a good control of membrane fouling.
In the electrodialysis reversal operating mode which has been developed by Ionics
Incorporated [7] the polarity of the electric field applied to the electrodialysis stack as the driving
force for the transport of ions is reversed in certain time intervals. Simultaneously the flow
streams are reversed, i.e. the diluate cell becomes the concentrate cell and vice versa with the
result that matter that has been precipitated at the membrane surface will be redisolved and
removed with the flow stream passing through the cell.

6.1. The Electrodialysis Stack and Process Design


An electrodialysis stack is composed of a multitude of cells placed in parallel between two
electrodes as illustrated in Figure 5.

43
ion-exchange
electrode membrane
cell

concentrate
diluate

electrode
rinse solution

feed solution

feed solution

electrode diluate cell


spacer concentrate cell

Fig. 5 Schematic drawing illustrating the construction of a sheet-flow electrodialysis stack.

The different cells are separated by ion-exchange membranes. In alternating cells a feed
solution is concentrated and desalinated, respectively. A spacer-gasket arrangement separates the
membranes and contain the manifolds to distribute the process fluids in the different
compartments. A proper electrodialysis stack design should provide a maximum effective
membrane area per unit stack volume and ensure equal and uniform flow distribution in each
compartment. The spacer screen should provide a maximum of mixing of the solutions at the
membrane surfaces and should cause a minimum in pressure loss. In praxis, two different stack
types are used on a large scale. One is the so-called sheet-flow and the other the tortuous path-
flow stack. In a sheet-flow electrodialysis stack the solution flow is in a straight path from the
entrance to the exit ports, which are located on opposite sides in the gasket as indicated in Figure
6 a). In the tortuous path flow stack, the membrane spacer gaskets have a long serpentine cut-out
which defines a long narrow channel for the fluid path which provides higher residence times of
the solution in the cells even at high flow velocities. A sheet flow and a tortuous path flow spacer
gasket are shown schematically in Figure 6 b).
a)
product outlet b)

product outlet

feed inlet

feed inlet

Fig. 6 Concept of a a) sheet-flow and b) tortuous path flow electrodialysis spacer gasket.

44
The distance between the membrane sheets, i.e. the cell thickness, should be as small as
possible to keep the energy consumption due to electrical resistance of the solutions as low as
possible. In industrial-size electrodialysis stacks, membrane distances are typically between 0.3
to 2 mm. A spacer is introduced between the individual membrane sheets to support the
membrane and to control the solution flow distribution.
Solution flow velocities in sheet-flow stacks are typically 3 to 10 cm s-1, whereas in tortuous
path flow stacks the solution flow velocities are 15 to 50 cm s-1. Because of higher flow
velocities and longer flow paths, higher pressure drops in the order of 2 to 3 bars are obtained in
stacks with tortuous path flow spacers than in sheet-flow systems where pressure drops are
between 0.5 and 2 bars. In a practical electrodialysis system, 200 to 1,000 cation- and anion-
exchange membranes are installed in parallel to form an electrodialysis stack providing 100 to
500 cell pairs. At each end of a stack there is an end-plate that contains the electrodes. Depending
on the feed solution composition and the product requirements electrodialysis units may be
operated in a batch-type, in a continuous, or in a feed-and-bleed mode with partial recycle of the
diluate and concentrate streams.
In practical applications two basic concepts of electrodialysis are used. One is referred to as
the unidirectional electrodialysis and the other as electrodialysis reversal. In an unidirectional
operated electrodialysis stack the electrical potential gradient across the stack is permanently
applied in one direction and the diluate and concentrate cells are also permanently fixed over the
period of operation. Unidirectionally operated electrodialysis plants are rather sensitive to
membrane fouling and scaling and often require frequent stack cleaning procedures. In
electrodialysis reversal the change of the electric potential across the stack is accompanied with a
reversal of the flow streams, i.e. the diluate becomes the concentrate and vice versa as shown in
the flow scheme of Figure 7.
In this operating mode, the polarity of the current is changed at specific time intervals
ranging from a few minutes to several hours and the hydraulic flow streams are reversed
simultaneously, i.e. the diluate cell will become the brine cell and vice versa.
The advantage of the reversed polarity operating mode is that precipitation in the brine cells
will be redesolved when the brine cell becomes the diluate cell in the reverse operating mode.
During the reversal of the polarity and the flow streams there is a brief period when the
concentration of the desalted product exceeds the product quality specification. Thus, in
electrodialysis reversal there is always a certain amount of the product lost to the waste stream.
feed inlet
feed

concentrate electrode waste

inlet
electrode

 FI CI CI
product

stack
feed
FI CI
off-spec
product
electrode waste

concentrate recycle

concentrate
blowdown
Fig. 7 Flow scheme of electrodialysis reversal in a continuous operating mode with the feed solution also
used as electrode rinse.

45
The main advantage of electrodialysis reversal is that suspended matters, polyelectrolytes,
and multivalent salts that are precipitated on the membrane surfaces are removed when the
polarity and the flow streams are reversed.
The degree of desalination that can be achieved in passing the feed solution through a stack
is a function of the solution concentration, the applied current density, and the residence time of
the solution in the stack which determines the process path length. If in a single process path the
required product concentrations are not achieved electrodialysis can be operated as a multi-stage
process, or a process with feed and bleed in which the diluate or the concentrate or both are
partially recycled.

6.2. Mass Transport in an Electrodialysis Stack


The degree of desalination in electrodialysis can be expressed by a material balance between
the feed, the concentrate, and the diluate solutions. It is a function of the residence time of the
different solutions in the cells, i.e. the flow velocities of the solutions, the membrane area in a cell
pair, and the applied current density. Calculation of the complete mass balance between the
diluate and concentrate flow stream can be rather complex for multi-component solutions and
high ion concentrations, which means high osmotic pressures and activity coefficients that
deviate largely from 1 and the two flow streams having different flow velocities and directions.
However, in many electrodialysis applications, e.g. in the desalination of brackish water the
concentrate and diluate cells have identical geometries and flow conditions, i.e. the flow rate in
both cells is co-current and of identical velocity. The transfer of ions in such a cell arrangement is
illustrated in Figure 8 which shows a cell pair of an electrodialysis stack containing a diluate and
concentrate flow stream parallel to the membrane surface in x-direction. The geometry of both
cells are identical and the two flow streams have the same flow velocity. It is assumed that the
concentration potential between the two flow streams due to different concentrations in the
diluate and concentrate solutions is negligibly low compared with voltage drops due to the
resistance of the solutions, and changes in the resistance of the solutions due to the boundary
layer effects are also negligible. Finally it is assumed that all diffusion processes between the two
flow streams can be neglected and the only driving force for the transport is the electrical
potential gradient which is constant over the entire cell length.
Under the above stated assumption the degree of desalination of a given feed solution, i.e.
the changes in the ion concentration in the diluate and concentrate cells in an area element
expressed in equivalents can be calculated as a function of the solution properties, the applied
voltage and the stack design by:
dC sd dC sc d C s J s (17)

i U cell
Furthermore is: J s dAcell , dAcell Ydx , and i (18)
FQcell C C sd
c
s am cm
c d
r r
s Cs Cs

Here i is the current density, F is the Faraday constant, is the current utilization, Ucell is the
applied voltage across the cell pair, dAcell is a cell pair area element, is the thickness of the cell,
s is the equivalent conductivity of the solution, ram and rcm are the resistances of the anion- and
cation-exchange membranes, and d Csd and d Csc are the concentration changes in a volume

46
element of the diluate and concentrate cell, d C s is the concentration change in a volume
element of the diluate and concentrate cell due to the ion flux through the membrane, Qcell is the
flow stream in the diluate or concentrate cell, Y is the cell width, and dx is a distance change in
direction of the flow stream parallel to the membrane surface, and s is an average value for the
cell pair

diluate concentrate
d c
(Csd , Q ) (Csc , Q )

x+dx x+dx
C
s
x x x

d
am (Csfd, Q ) cm (C fc, Qc ) am z
s
feed solution feed solution

Fig. 8 Schematic drawing illustrating the flow of a diluate and concentrate stream parallel to the
membrane surface in a cell pair of an electrodialysis stack and the concentration change between diluate
and concentrate solution C s due to the ion flux through the membrane.

Introducing Equation 17 into Equation 18 and integrating over the cell length leads to:

C sc C sfd s r am r cm C sfd C sd s U cell YX


ln (19)
C sd C sfc FQcell
Here C sfd and C sfc are the concentrations of the diluate and the concentrate at the cell inlet, C sd
and C sc are the concentrations of the diluate and the concentrate at the cell outlet, Y X and are
the cell width, length and thickness.
The total flow of the diluate or concentrate solution through a stack is given by:
Qst N Qcell N Yu (20)
Here Qst is the total solution flow of the diluate, respectively, the concentrate through the entire
stack, Qcell is the flow through one cell, N is the number of cells in the stack, is the thickness
and Y the width of a cell, and u is the linear flow velocity in the cell.
The total voltage across the stack Ust is given by:

47
U st NU cell (21)
Equations 19 to 21 give the relations between the various stack construction data such as cell
length, cell width, and cell thickness, the solution properties such as the concentrations of the
feed, the concentrate and the product, and their conductivity, the flow velocity in the cells and the
applied voltage. But to design an electrodialysis stack for a certain plant capacity it must be taken
into consideration that the current density cannot exceed the limiting current density.
Introducing the limiting current density and multiplying with the number of cell pairs in the
stack gives the maximum voltage applied to the stack Ust,lim that should be exceeded in
electrodialysis:
N ! C sd sCs
d
U st ,lim ilim c
1 r am r cm (22)
s Cs
Here Ust,lim is the limiting applied voltage across a stack, ilim is the limiting current density
C s and C sd are the concentrations in the diluate and concentrate solution, s is the equivalent
d

conductivity of the salt solution, ram and rcm are the area resistances of the anion- and cation-
exchange membrane, is the cell thickness, and " is the number of cell pairs in a stack.
Combination of Equations 20, 21 and 22 and rearranging gives the required membrane area
of the complete stack as function of the applied voltage and the feed, the diluate and the
concentrate solution, the cell geometry, the solution flow velocities

! C sc C sfd s r am r cm C sfd C sd
ln
C sd C sfc Yu u sd
Ast N cell (23)
! C sd s C sd am cm
ilim
1 r r
C sc
Here Ast is the total cell pair area installed in the stack, and Ncell is the number of cell pairs in
the stack, C sfd and C sfc are the concentrations of the diluate and the concentrate at the cell inlet,
C sd and C sc are the concentrations of the diluate and the concentrate at the cell outlet, s is the
am cm
equivalent conductivity of the salt solution, r and r are the area resistances of the anion- and
cation-exchange membrane, is the cell thickness, i.e. the distance between the cation- and
anion-exchange membrane, Y is the cell width, u is the linear flow velocity, F is the Faraday
constant, ilim is the limiting current density, and is the current utilization.
From the cell pair area required for a certain capacity plant and the cell dimensions the
process path length can be determined by:
Acell
L pp (24)
Y
Here is Lpp the process path length for a given plant capacity and cell dimensions. It becomes
identical with the cell length X when desalination is achieved in one path through the cell.

48
7. Energy Requirements in a Electrodialysis Desalination Process
The total energy requirements in a practical electrodialysis process is the additive of four
terms:
the energy required for the transport of ions from a feed to a concentration solution,
the energy necessary to pump the solutions through the stack from a feed solution
reservoir to the product tank and brine disposal,
the energy consumed by the electrode reactions, and
the energy required to operate various process control and measuring instruments.
The last two terms can generally be neglected in larger capacity plants.
The energy required for transfer of ions through a membrane consists of two parts. The first
part is the reversible energy given by the Gibb's free energy of mixing the diluate and concentrate
solutions. It is the minimum energy required for the separation of components in a mixture. It is
identical for any separation process. The second part is the energy required to overcome the
friction between the transported components and the membrane matrix. It represents the
irreversible energy loss.
In electrodialysis the minimum work that is required for converting a feed solution into a
concentrate and a diluate is given to a first approximation by [3]:
C sf C sf
ln ln
G C sc C sd
RT C sf C sd (25)
Vd C sf C sf
1 1
C sc C sd

Here G is the Gibb’s free energy required for the production of the diluate, C is the salt
concentration, the superscripts f, d, and c refer to feed, diluate, and the concentrate, respectively;
Vd is the volume of the diluate.
Equation 25 gives the energy required per volume diluate to convert a given feed solution
into a diluate and a concentrate.
The total energy required in a practical electrodialysis for the transfer of ions includes
irreversible losses due to the electrical resistances of the membrane and the solutions and is given
by the total current passing through the stack multiplied by the applied voltage. The total current
passing through a cell pair is given by:
N cell Qcell F C sfd C sd
I (26)

Here I is the total electric current passing through the cell pair, Qcell is the flow rate of the
solution in the diluate cell, C sfd and C sd are the diluate feed and product equivalent
concentrations, and Ncell are the numbers of cell pairs in the stack.
The required electrical power for the transfer of ions in a desalination process is given by the
total current passing through the stack multiplied by the applied voltage. It is given by:

49
FQ cell C sfd C sd
Pdes N cell U cell I N cell U cell (27)

Introducing Equations 18 and 19 into Equation 27 and rearranging gives the power
requirements for the desalination process in a stack:
! C sfd C sc
ln fc d d fd 2
N cell Cs Cs am cm ! Qcell F C s C sd
Pdes N cellU cell I fd
r r (28)
Acell s Cs C sd

Multiplying the power requirements with the time of operation gives the energy required for
the amount of product obtained in this time:
! C sfd C sc
ln 2
N cell t C sfc C sd am cm
d
! Qcell F C sfd C sd
E des N cellU cell I t r r (29)
Acell s C sfd C sd

Thus, the specific energy required for an unit volume product is:
! C sfd C sc
ln 2
N cellU cell I N cell C sfc C sd am cm
d
! Qcell F C sfd C sd
E des/spec. r r (30)
Qst Acell Qst s C sfd C sd

Here Edes and Edes/spec are the desalination costs for the desalination in electrodialysis and the
cost per unit volume product, I is the total current and Ucell the voltage per cell, Ncell is the number
of cell pairs in a stack, t is the time of operation; C sfd and C sfc are the equivalent concentrations of
the diluate and the concentrate at the cell inlet, C sd and C sc are the concentrations of the diluate
and the concentrate at the cell outlet, s is equivalent conductivity of the salt solution, ram and rcm
are the area resistances of the anion- and cation-exchange membrane, is the cell thickness, is
the current utilization, and Qcell and Qst are the diluate flow velocities in a cell and in the entire
stack, respectively, Acell is the cell pair area.
The energy needed to pump the various flow streams through the stack is given by:

Ep Qd pd Qc pc Qe pe
E p / spec k eff (31)
Qd t Qd
Here Ep/spec is the total energy per unit diluate water for pumping the diluate, the concentrate,
and the electrode rinse solution through the stack, keff is an efficiency term for the pumps, and Qd,
Qc, and Qe are the volume flow rates of the diluate, the concentrate, and the electrode rinse
solution through the stack.
The energy consumed by the electrode reaction and required for the operation of the control
and measuring instruments are generally neglected or taken as a fixed item which is between 1
and 3% of the energy used for the ion transfer and pumping of the solutions

50
8. Electrodialysis Processes Costs
The total production costs in electrodialysis are the sum of fixed charges associated with
amortization of the plant investment costs and of operating costs such as energy and maintenance
requirements.
The investment costs include non-depreciable items such as land and depreciable items such
as the electrodialysis stacks, pumps, electrical equipment, monitoring and control devices, and
membranes. The required membrane area for a given capacity plant is inverse proportional to the
current density and is direct proportional to the quantity and quality of the product from a given
feed solution.
The total operating costs of the electrodialysis plant include energy and maintenance costs
and all pre- and post-treatment procedures. They are also a function of the membrane properties,
feed and product composition, and several process and equipment design parameters such as
stack construction. A dominant role in electrodialysis process costs plays the applied current
density since it effects the investment costs as well as the energy costs directly. The required
membrane area is decreasing with increasing current density while the consumed energy is
increasing with the current density as shown in Equations 22 and 23. Thus, the total product costs
which are the sum of energy costs, amortization and maintenance costs are a function of the
current density and will reach a minimum at a certain current density. This is schematically
shown in Figure 9. Here, the total process costs, the energy costs, the amortization on membrane
and hardware investment, and the maintenance costs are shown as function of the applied current
density. The optimum operating current density in electrodialysis depends to a large extent on the
equipment, and especially on the membrane costs and life, and on the cost of energy. The current
density to be applied in electrodialysis is determined by the limiting current density.

total process costs


costs

energy costs

membrane investment costs

maintenance costs
applied current density

Fig. 9 Schematic diagram illustrating the process costs in electrodialysis as a function of the
applied current density.

In many applications, electrodialysis competes with other separation processes such as


reverse osmosis. Although the theoretically required minimum energy is identical in both
processes, the irreversible energy dissipation differs considerably. The irreversible energy loss in
reverse osmosis is caused by hydraulic resistance of the membrane to the water flux and is thus
independent of the feed salt concentration. In electrodialysis the irreversible energy loss is caused

51
by the electrical resistance of the ions flux through the membrane, it is thus for a given product
water concentration directly proportional to the feed water concentration. For feed solutions with
low salt concentrations the energy requirements are therefore generally lower in electrodialysis
than in reverse osmosis; with feed solutions having a high salt concentration the situation is
reversed.

8.1. Calculation of an Electrodialysis Plant


The calculation procedure for designing an electrodialysis plant is based on a number of
input parameters which consist of values related to a given stack geometry, solution properties,
and operating strategies. The total process path length as calculated by Equation 24 is related to
the path length of a given stack by:
L prac Lst N st (32)
Here are Lprac and Lst the practical process path length and the length of a stack, and Nst is the
number of stacks in series in a plant.
The length of a stack is given by the manufacturer. The number of stacks in series Nst is 1 or
a positive integer. This means that Equation 32 generally does not balance when the practical
process path length is used. Therefore, the practical process path length must be adjusted to meet
the requirements of Equation 32. The practical process path length is related to the product
concentration, the feed concentration, the concentrate concentrations, the linear flow velocity, the
limiting current density, etc. However, this relation cannot be solved for a desired product
concentration and process path length explicitly, and an iteration must be executed based on an
assumed value of the product concentration and length of the stack or the stacks in series.
Another important parameter for the design of a plant is the recovery rate applied in the
process. The recovery rate determines which fraction of a feed solution is obtained as product,
i.e.:
p
Q prac
f
(33)
Q prac
p f
Here is the recovery rate, and Q prac and Q prac are the flow rates of the product and the two
feed solutions of the diluate and concentrate cell.
The recovery rate has a value between 0 and 1. If in a stack, where the diluate and
concentrate cells have identical geometries the recovery rate is 0.5, the product flow rate is
identical to that of the concentrate. For any other recovery rate product and concentrate flow rates
are different, and one flow stream must be operated in a feed and bleed mode to obtain identical
linear flow velocities in the diluate and concentrate cells.
The concentrations of diluate and concentrate are related to the recovery rate by a mass
balance. If identical flow velocities of the diluate and concentrate streams are assumed the
required concentrations of the concentrate feed solution and the final concentration of the
concentrate for a given diluate feed concentration and required product concentration are given
by:

52
C sfd C sd C sfd 1 C sc 2 1
C sc and C fcs (34)
1-
The calculation procedure for the construction of a typical brackish water electrodialysis
desalination plant is illustrated in the flow scheme of Figure 10.

feed and product concentration


current efficiency stack related
production rate input data
recovery rate
flow velocity

solution properties
membrane properties operation related
stack geometry input data
design parameters (#$%)
limiting current constants(a,b,s)

brine concentration
required cell pair area
process path length basic
number of cell pairs output data
voltage and current density
energy consumption

yes number of stacks no


integer? round up/down
number of stacks

basic corrected output data


output data (path length, membrane area,
number of cell pairs,flow velocity,
voltage, current, current density
energy consumption)

stack voltage and current


power supply for desalination

Fig. 10 Flow sheet illustrating the calculation procedure for an electrodialysis desalination plant.

The input data consist of values related to the plant hardware components such as the
membrane properties, the electrodialysis stack geometry including safety factors taking into
account the current utilization and the effect of the spacer on the cell volume or the flow
distribution, the feed and product solution concentrations, and the operating strategies such as
feed flow velocities and recovery rate. Output data are the process path length, the number of
stacks in series or in parallel, the total required membrane area, the limiting current density, the
applied voltage, and the energy consumption. For the cost analysis energy required for pumping
the solutions through the stack must be calculated and charges related to the total investment and
operation must be estimated.

53
8.2. Product Water Costs
The product water costs in the above described example calculation are made under certain
assumptions in terms of feed and product water quality, and equipment and energy costs. These
items may vary substantially depending on feed water composition, plant capacity and location,
etc. However, some general relations are true for all electrodialysis applications. The water
production costs are increasing with the feed water salinity assuming a given product water
quality as indicated in Equation 23 which relates the required membrane area to the feed solution
concentration and Equation 29 which gives a relation between the desalination energy and the
feed solution concentration. Pumping energy requirements and investment for equipment such as
pumps, piping and control devices are independent of the feed solution concentration. The
product water costs as function of the feed solution concentration assuming a constant product
concentration are illustrated in Figure 11 which shows schematically the operating costs which
also include the energy costs and the membrane area and other investment related costs as well as
total desalination costs as function of the feed water concentration.
specific costs [US $ m-3]

1.2 total costs


1
0.8 desalting costs
0.6
0.4 membrane related costs
0.2
0
0 0.2 0.4 0.6 0.8
feed concentration [eq L-1]

Fig. 11 Schematic diagram illustrating the electrodialysis desalination costs as function of the
feed solution concentration assuming constant product concentration [5].
Figure 11 shows that both the operating and the investment related costs and thus the total
product costs are strongly increasing with the feed solution concentration when the product
concentration and all other parameters are kept constant. The absolute cost values are subject to
plant capacity and location, costs of hardware components, labor costs, etc. Costs of water
produced in a commercial electrodialysis desalination plant can vary significant, i.e. more than
50% from that given in the Figure 11.

References
1. Schaffer, L.H., Mintz, M.S. , 1966. Electrodialysis, in: Principles of desalination, edt.:
Spiegler, K.S., pp. 3-20, Academic Press, New York.
2. Bergsma, F., Kruissink, CH.A., 1961. Ion-exchange membranes, Fortschr. Hochpolym.-
Forsch., 21: 307-362.
3. Strathmann, H., 2004. Ion-exchange Membrane Separation Processes, Elsevier, Amsterdam
4. Spiegler, K.S., Laird, A.D.K., edts., 1980. Principles of desalination, 2nd edition, Academic
Press, New York.
5. Lee, H.J., Safert, F. Strathmann, H., Moon, S.H., 2002. Designing of an electrodialysis
desalination plant, Desalination, 142: 267-286.
6. Wilson, J.R., edt., 1960. Demineralization by electrodialysis, Butterworth Scientific
Publications, London.
7. Katz, W.E., 1979. The electrodialysis reversal (DER) process, Desalination,, 28: 31-40.

54

Vous aimerez peut-être aussi