Vous êtes sur la page 1sur 11

TOP VIEW

LEFT SIDE VIEW FRONT VIEW RIGHT SIDE VIEW


CUSTOMER NOTES:
UNLESS OTHERWISE SPECIFIED DIMENSIONAL TOLERANCE +/-13 mm.
COOLING COND CONNS ARE STRAIGHT OUT THE END OF THE WATER BOX. SHELL TYPE CONN DIA CONN TYPE FLOW DIRECTION
Job01

WATER BOX DRAIN AND VENT LOCATIONS ARE SHOWN ON THE WATER BOX END PLATES.
EVAPORATOR 203 mm VICTAULIC IN FRONT OUT REAR
COOLING COND 254 mm VICTAULIC IN BOTTOM OUT TOP

TOPSS Dimension Drawing


ALL WEI GHTS AND DI MENSI ONS ARE APPROXI MATE.
Page: 1
Items: CCTV-0008

12/20/2018 9:25:50 AM
China CenTraVac Centrifugal Chiller

Qty: 1 Tags: CCTV-0008


CVHG

1533 mm 648 mm
Economizer

Condenser
Purge

Rupture Compressor
Disk 3" NPT

Unit Mounted
EVAPORATOR Solid State Starter

AdaptiView Control Panel


touch screen is field installed
(See accessory drawing for details)

334 mm

TOP VIEW
Job01

3455 mm
184 mm

TOPSS Dimension Drawing


ALL WEI GHTS AND DI MENSI ONS ARE APPROXI MATE.
Page: 2
Items: CCTV-0008

12/20/2018 9:25:50 AM
China CenTraVac Centrifugal Chiller

Qty: 1 Tags: CCTV-0008


Job01 China CenTraVac Centrifugal Chiller
Items: CCTV-0008
Qty: 1 Tags: CCTV-0008
12/20/2018 9:25:50 AM

1073 mm

405 mm
309 mm
FRONT VIEW
2468 mm

3429 mm
CVHG

144 mm

258 mm

TOPSS Dimension Drawing


ALL WEI GHTS AND DI MENSI ONS ARE APPROXI MATE. Page: 3
Job01 China CenTraVac Centrifugal Chiller
Items: CCTV-0008
Qty: 1 Tags: CCTV-0008
12/20/2018 9:25:50 AM

1254 mm
1149 mm

LEFT SIDE VIEW


463 mm

1750 mm
CVHG

TOPSS Dimension Drawing


ALL WEI GHTS AND DI MENSI ONS ARE APPROXI MATE. Page: 4
Job01 China CenTraVac Centrifugal Chiller
Items: CCTV-0008
Qty: 1 Tags: CCTV-0008
12/20/2018 9:25:51 AM

1313 mm

893 mm

RIGHT SIDE VIEW


341 mm

2091 mm
1294 mm
701 mm
225 mm
640 mm
CVHG

391 mm
2635 mm

TOPSS Dimension Drawing


ALL WEI GHTS AND DI MENSI ONS ARE APPROXI MATE. Page: 5
Job01 China CenTraVac Centrifugal Chiller
Items: CCTV-0008
Qty: 1 Tags: CCTV-0008
12/20/2018 9:25:51 AM

NUTS SHOULD NOT BE TIGHT UNIT MOUNTING PAD


LEAVE 1/16 TO 1/8 GAP 1/2 THICK (BY TRANE)

1. HEAVY OBJECTS! VIBRATION ISOLATOR


DO NOT USE CABLES (CHAINS OR SLINGS) EXCEPT AS SHOWN. EACH OF (BY TRANE)
THE CABLES (CHAINS OR SLINGS) USED TO LIFT THE UNIT MUST BE
CAPABLE OF SUPPORTING THE ENTIRE WEIGHT OF THE UNIT. LIFTING
CABLES (CHAINS OR SLINGS) MAY NOT BE OF THE SAME LENGTH. ADJUST 3" STL PIPE
AS NECESSARY FOR EVEN UNIT LIFT. OTHER LIFTING ARRANGEMENTS
TO MEET
MAY CAUSE EQUIPMENT OR PROPERTY-ONLY DAMAGE. FAILURE TO LOCAL CODES
PROPERLY LIFT UNIT MAY RESULT IN DEATH OR SERIOUS INJURY. 1/4
SEE DETAILS BELOW.
2. IMPROPER UNIT LIFT!
TEST LIFT UNIT APPROXIMATELY 24 INCHES TO VERIFY PROPER CENTER 6 X 6 X 3/4
OF GRAVITY LIFT POINT. TO AVOID DROPPING OF UNIT, REPOSITION LIFTING STL PLATE
POINT IF UNIT IS NOT LEVEL. FAILURE TO PROPERLY LIFT UNIT COULD 1/8 CONCRETE
RESULT IN DEATH OR SERIOUS INJURY OR POSSIBLE EQUIPMENT OR
PROPERTY-ONLY DAMAGE. ANCHOR BOLT DETAIL
3. ATTACH SAFETY CHAIN OR CABLE AS SHOWN WITHOUT TENSION, NOT AS RECOMMENDED PROCEDURE TO ALLOW FOR THERMAL
A LIFTING CHAIN OR CABLE, BUT TO PREVENT THE UNIT FROM ROLLING. EXPANSION (UNLESS OTHERWISE SPECIFIED, PARTS ARE
FURNISHED BY CUSTOMER). ANCHORING THE UNIT IS NOT
4. DO NOT FORKLIFT THE UNIT TO MOVE OR LIFT.
A REQUIREMENT, IT MAY BE RECOMMENDED FOR SPECIFIC
5. LIFTING HOLES PROVIDED ON CHILLER TO ATTACH CABLES (CHAINS OR SLINGS).
APPLICATIONS.
6. 36" (900 MM) RECOMMENDED CLEARANCE ABOVE HIGHEST POINT OF COMPRESSOR.
7 FOLLOW NEC SECTION 110 AND OTHER APPLICABLE LOCAL CODES
FOR CLEARANCES IN FRONT OF ELECTRICAL ENCLOSURES.
8. SPECIFIC SHIPPING AND OPERATING WEIGHTS OF THE SUBMITTED
CHILLER ARE PROVIDED IF THE CENTRIFUGAL CHILLER SELECTION
WAS ENTERED IN TOPSS. DETAILED LOAD POINT AND SPRING
ISOLATOR APPLICATION WEIGHTS ARE AVAILABLE FROM "CENTRAVAC
ISOLATOR SELECTION REPORT" AVAILABLE FROM THE REPORT GENERATOR SAFETY CHAINS
OF THE TRANE TOPSS CHILLER SELECTION PROGRAM. CONTACT OR CABLES
YOUR LOCAL TRANE SALES ENGINEER IF THIS DATA IS REQUIRED.

4 E
E SPAC
RANC
CLEA Y
PLTO
OW N,SIAP
ON
PUL
SH MEN
TUBEGOOD EN
BE PULLCE DI
NDLLDISCOND
D TU EA RAN
FT HAPUAN
T HA NLL CL R LE
FOED TU BE R
RATO
GHBE
RITU PU
EN D NCAP O
(SEE NOTE 8 ABOVE) LERE REEV
FTFETH
TAIL BO
MAXIMUM SHIPPING <<2048733~FV>> LE DE
<<2048732~FV>> CH O R HO
SEE AN
MAXIMUM OPERATING 5" TYP (127mm)
TS
IT SHEE
OF UN S TU
BE
FRO NT INCLUDE
2 5/8" TYP (67mm) X .88 (22mm)
SION
DIMEN
1 3/16" TYP (30mm) DIA HOLES FOR
ANCHORING UNIT

870 mm
EVAPORATOR
5" TYP (127mm)
U

TUBESHEET 2" TYP YP T


(12
)OR
TYP
YP
7mm)
(UN6
(3
m m)
I70Tmm)
5//"T2
8"6E
1mm "NG
S ATOR
RFEET T AIL
X.88 H15
2(2
3
HOL
V
E ORI
APO DE
D
ANC
IA YPBESH
U
T
"Tmm) OR NER
HOLE
21
(5 CHC
ENCHOR
A

(51mm)

X .88 (22mm) 2 5/8" TYP (67mm)


1750 mm
DIA HOLES FOR 1 3/16" TYP (30mm)
ANCHOR HOLE DETAIL
ANCHORING UNIT
EACH CORNER

EVAPORATOR
2" TYP TUBESHEET
(51mm)
1327 mm 3429 mm 3581 mm

ANCHOR HOLE DETAIL 8338 mm

EACH CORNER

SEE ANCHOR HOLE DETAIL


CLEARANCE SPACE

RIGHT HAND TUBE PULL SHOWN, APPLY


TUBE PULL CLEARANCE DIMENSION TO
LEFT END FOR LEFT HAND TUBE PULL.
REFERENCED TUBE PULL IS GOOD FOR
BOTH EVAPORATOR AND CONDENSER

FRONT OF UNIT

DIMENSION INCLUDES TUBESHEETS

F
G

TOPSS Dimension Drawing


ALL WEI GHTS AND DI MENSI ONS ARE APPROXI MATE. B E
Page: 6
Job01 China CenTraVac Centrifugal Chiller
Items: CCTV-0008
Qty: 1 Tags: CCTV-0008
12/20/2018 9:25:51 AM

LUG SIZES SHORT CIRCUIT


STARTER MAX APPROX WEIGHT VOLTS PANEL BREAKER
L1-L3 CONNECTION AIC AMPS WITHSTAND
SIZE RLA (kg)
(EACH PHASE) RATING AMPS

L 554 (2)25-240 mm2 279.4 kg 380 DISC N/A 6,000

NOTES:
RATINGS ARE X 1000 AMPS INTERRUPTING CAPACITY (KAIC).
STARTER SCWR RATINGS ARE FOR THE MOLDED CASE SWITCH OPTION.
MOLDED CASE SWITCH = NON-FUSED DISCONNECT SWITCH.
MAIN LUG ONLY (MLO) = NO DISCONNECT OR BREAKER. MLO STARTER
SCWR RATINGS ARE THE SAME AS STARTER SCWR RATINGS OF
THE MOLDED CASE SWITCH OPTION.
BREAKER AIC (AMPS INTERUPTING CAPACITY) =
APPLIES TO THE CIRCUIT BREAKER AS A COMPONENT ONLY
AND IS THE MAXIMUM CURRENT THAT A CIRCUIT BREAKER
CAN INTERUPT WITHOUT DAMAGE TO ITSELF.
145 MAX DOOR SWING THE AIC RATING FOR HIGH INTERRUPT WORLD CLASS CIRCUIT
(965mm) BREAKERS OF 65,000A AT 480V IS EQUIVALENT
TO 70,000A AT 415V.
STARTER SCWR (SHORT CIRCUIT WITHSTAND RATING) =
THE MAXIMUM FAULT CURRENT TO WHICH A STARTER
MAY BE EXPOSED AND SAFELY BE CONTAINED WITHIN
THE STARTER ENCLOSURE. HOWEVER, THE COMPONENTS
MAY SUSTAIN DAMAGE.
CIRCUIT BREAKER FRAME SIZES ARE ELECTRONIC TRIP TYPE.
(X/X/X) VALUES LISTED ARE NEMA 380/400/415 VOLT.
36 mm 394 mm 106 mm 394 mm N/A = NOT APPLICABLE.
40 mm TERMINALS ACCEPT CU/AL WIRE.

254 mm

459 mm

157 mm
965 mm
Ø 38 mm
37 mm 598 mm 48 mm

17 mm 76 mm
66 mm

307 mm

1572 mm
1524 mm

753 mm

TOPSS Dimension Drawing


ALL WEI GHTS AND DI MENSI ONS ARE APPROXI MATE. Page: 7
Job01 China CenTraVac Centrifugal Chiller
Items: CCTV-0008
Qty: 1 Tags: CCTV-0008
12/20/2018 9:25:51 AM

LEFT REAR RIGHT REAR

ISOLATOR SELECTION
LOCATION ISOLATOR LOAD* TRANE P/N ISOLATOR COLOR
LEFT FRONT LEFT
5529.0 lb FRONT X10144507005 GRAY RIGHT FRONT
LEFT REAR 3287.0 lb X10144507002 DK PURPLE
RIGHT FRONT 7728.0 lb X10144507006 WHITE
RIGHT REAR 5051.0 lb X10144507004 DK GREEN
LEFT MIDDLE N/A

UNIT CENTER OF GRAVITY


CG Z (DIMENSION FROM RIGHT TO LEFT) 53.000 in
CG X (DIMENSION FROM FRONT TO REAR) 27.000 in
CG Y (HEIGHT DIMENSION FROM FLOOR) 51.000 in

RIGHT FRONT ISOLATOR MOUNTING HOLE


BOTTOM OF THIS HOLE IS 0,0,0 POINT
FOR CENTER OF GRAVITY DIMENSIONS
Y

Z X

NAMEPLATE PRODUCT DESCRIPTION:


WEIGHTS MODL CVHG VOLT 380 PTON 1758.43 kW NTON 565
EVTM TECU CDTM TECU CPKW 299 CPIM 265
SHIPPING OPERATING
8771 kg 9795 kg CDBS 560 EVSZ 050S EVBS 580
ORSZ 630 CDSZ 080S

*ALL PUBLISHED WEIGHTS ACCURATE TO +/- 10 %

TOPSS Dimension Drawing


ALL WEI GHTS AND DI MENSI ONS ARE APPROXI MATE. Page: 8
Job01 China CenTraVac Centrifugal Chiller
Items: CCTV-0008
Qty: 1 Tags: CCTV-0008
12/20/2018 9:25:51 AM
ADAPTIVIEW CONTROL PANEL TOP VIEW
832 mm
685 mm

66 mm 137 mm

172 mm

168 mm
28 mm DIA HOLE
508 mm
TYPICAL HOME 22 mm DIA HOLE
POSITION

6 HOLES FOR CONTROL WIRING CONDUITS

664 mm

406 mm

NOTE: DISPLAY CAN MOVE TO AN


INFINITE NUMBER OF POSITIONS.

191 mm
REF-BOTTOM FRONT
OF PANEL DOOR

LOWEST POSITION
AVAILABLE

TOPSS Dimension Drawing


ALL WEI GHTS AND DI MENSI ONS ARE APPROXI MATE. Page: 9
Job01 China CenTraVac Centrifugal Chiller
Items: CCTV-0008
Qty: 1 Tags: CCTV-0008
12/20/2018 9:25:51 AM

WARNING
HAZARDOUS VOLTAGE!
DISCONNECT ALL ELECTRIC POWER INCLUDING CAUTION
REMOTE DISCONNECTS AND FOLLOW LOCK OUT
AND TAG PROCEDURES BEFORE SERVICING. USE COPPER CONDUCTORS ONLY!
INSURE THAT ALL MOTOR CAPACITORS HAVE
DISCHARGED STORED VOLTAGE. UNITS WITH
VARIABLE SPEED DRIVE, REFER TO DRIVE UNIT TERMINALS ARE NOT DESIGNED TO ACCEPT
INSTRUCTIONS FOR CAPACITOR DISCHARGE. OTHER TYPES OF CONDUCTORS.
FAILURE TO DO THE ABOVE BEFORE SERVICING
COULD RESULT IN DEATH OR SERIOUS INJURY. FAILURE TO DO SO MAY CAUSE
DAMAGE TO THE EQUIPMENT.

* CONNECTION DIAGRAMS ARE AVAILABLE AT THE WEBPAGE SHOWN IN THE MECHANICAL SPECIFICATIONS SECTION OF THIS SUBMITTAL.
NOTES:
1. DASHED LINES INDICATE RECOMMENDED FIELD WIRING BY OTHERS. CHECK SALES ORDER TO DETERMINE IF WIRING IS REQUIRED FOR SPECIFIC OPTIONS.
2. CAUTION - DO NOT ENERGIZE UNIT UNTIL CHECK-OUT AND START-UP PROCEDURES HAVE BEEN COMPLETED.
REQUIRED
3. ALL CUSTOMER CONTROL CIRCUIT WIRING MUST HAVE A MINIMUM RATING OF 150 VOLTS.
4. ALL FIELD WIRING MUST BE IN ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE
(NEC), STATE AND LOCAL REQUIREMENTS. OUTSIDE THE UNITED STATES, OTHER
COUNTRIES APPLICABLE NATIONAL AND/OR LOCAL REQUIREMENTS SHALL APPLY.
5. EVAPORATOR AND CONDENSER FLOW SWITCHES ARE REQUIRED. THEY MUST BE
INSTALLED AND WIRED TO THE TRANE PANEL BY THE INSTALLING CONTRACTOR.
PURCHASE OF SWITCHES FROM TRANE IS OPTIONAL.
6 2 WIRES, 115 VAC CIRCUIT, SEPARATE POWER SUPPLY IS REQUIRED. MINIMUM
CONTACT RATING AT 115 VAC - 2.88 INDUCTIVE 1/3 H.P.(.25 kW) AT 115 VAC REQUIRED.
7 2 WIRES, 115 VAC CIRCUIT, SEPARATE POWER SUPPLY IS REQUIRED. CONTACTS
ARE N.O. CONTACT RATING - 2.88 INDUCTIVE 1/3 H.P.(.25 kW) AT 115 VAC OPTIONAL. TRACER OR OTHER TRANE REMOTE
8 2 OR 3 WIRES(N.O. &/OR N.C.), 115 VAC CIRCUIT, SEPARATE 115 VAC POWER SUPPLY IS 12
DEVICE (COMMUNICATIONS INTERFACE)
REQUIRED. CONTACTS ARE NO/NC RATINGS - 2.88 INDUCTIVE 1/3 H.P.(.25 kW) AT 115 VAC.

12 SHIELDED PAIR. 30 VOLT OR LESS CIRCUIT. MAX


LENGTH 1500 FT. BELDON TYPE 8760 RECOMMENDED. (2 WIRES)

LOW VOLTAGE (30V MAX)


THE UNIT CONTROL PANEL (CH.530) SUPPLIES A CONTACT DO NOT RUN WITH HIGHER
OUTPUT TO CONTROL THE CUSTOMER SUPPLIED DEVICES VOLTAGE CIRCUITS
SHOWN BELOW. MAXIMUM FUSE SIZE PER DEVICE - 15 AMPS.

CHILLED WATER PUMP STARTER 7 EXTERNAL AUTO/STOP (CONTACT)

CONDENSER WATER PUMP STARTER 6 EMERGENCY STOP NORMAL/TRIP (CONTACT)

HEAD RELIEF REQUEST RELAY 8

MAXIMUM CAPACITY RELAY 8

REMOTE ALARM RELAY (LATCHING) 8

REMOTE ALARM RELAY (NON-LATCHING) 8

LINE
PURGE REMOTE ALARM 8 VOLTAGE
(SEE NAMEPLATE)
COMPRESSOR RUNNING RELAY 8

LIMIT WARNING INDICATOR 8

UNIT
MOUNTED
STARTER

COND CONTROL
WATER PANEL
PUMP LEAVING
COND CONDENSER
WATER

LEAVING
EVAP CONTROL VOLTAGE CHILLED
115 VOLTS
WATER
CHILLED FRONT ELEVATION
WATER PUMP

TOPSS Dimension Drawing


ALL WEI GHTS AND DI MENSI ONS ARE APPROXI MATE. Page: 10
Job01 China CenTraVac Centrifugal Chiller
Items: CCTV-0008
Qty: 1 Tags: CCTV-0008
12/20/2018 9:25:52 AM

CUSTOMER SUPPLIED
LINE VOLTAGE
(SEE UNIT NAMEPLATE)

GND L1 L2 L3

G L1 L2 L3

2Q1 OR 2S1 DISCONNECT


OR 2X3 TERMINAL BLOCK

WARNING
HAZARDOUS VOLTAGE!
DISCONNECT ALL ELECTRIC POWER INCLUDING
REMOTE DISCONNECTS AND FOLLOW LOCK OUT
AND TAG PROCEDURES BEFORE SERVICING.
INSURE THAT ALL MOTOR CAPACITORS HAVE
DISCHARGED STORED VOLTAGE. UNITS WITH
VARIABLE SPEED DRIVE, REFER TO DRIVE
INSTRUCTIONS FOR CAPACITOR DISCHARGE.
FAILURE TO DO THE ABOVE BEFORE SERVICING
COULD RESULT IN DEATH OR SERIOUS INJURY.

CAUTION
USE COPPER CONDUCTORS ONLY!
UNIT TERMINALS ARE NOT DESIGNED TO ACCEPT
OTHER TYPES OF CONDUCTORS.
FAILURE TO DO SO MAY CAUSE
DAMAGE TO THE EQUIPMENT.

WIRE NO OR DEVICE FIELD WIRING CIRCUIT SELECTION INFORMATION


SUPPLY AND MOTOR LEADS SEE NAMEPLATE; MINIMUM CIRCUIT AMPACITY
1A* 4000VA AT 115VAC, 8 AWG MAX WIRE SIZE
2A* AND GRN/YEL 4000VA AT 115VAC, 8 AWG MAX WIRE SIZE (WITHOUT OPTIONAL CPTR)
2A* AND GRN/YEL CIRCUIT PROTECTED AT 20A, 115VAC 1PH, 10 AWG MAX WIRE SIZE (WITH OPTIONAL CPTR)
9A* AND 10A* PUMP MOTOR; 1PH 3/4 HP, 11.7 FULL LOAD AMPS AT 115VAC. 14 AWG MAX WIRE SIZE.
TWISTED, SHIELDED PAIR, 30VDC, MAX LENGTH 1500 FT
WB4
DEVICE PREFIX CODE (BELDEN TYPE 8760 RECOMMENDED)

1 = MAIN UNIT CONTROL PANEL DEVICE 5S1*, 5S2*, 3B* AND 4B* CIRCUIT PROTECTED AT 20A, 115VAC 1PH, 10 AWG MAX WIRE SIZE
2 = REMOTE MOUNTED DEVICE
5S3 THRU 5S8 24VDC, 12MA RESISTIVE LOAD, 14 AWG MAX WIRE SIZE
4 = UNIT MOUNTED DEVICE
5 = CUSTOMER PROVIDED DEVICE ALL REMAINING LLID TERMINALS CONTACT RATING; 2.88A INDUCTIVE, 1/3 HP, 0.25KW AT 115VAC. 14 AWG MAX WIRE SIZE.

* TAPPED CONTROL CONDUCTORS


NOTES:
1. DASHED LINES INDICATE FIELD WIRING BY OTHERS. WIRE NUMBERS SHOWN ARE RECOMMENDED BY TRANE.

2. DO NOT ROUTE LOW VOLTAGE (30V) WITH CONTROL VOLTAGE (115V) AND DO NOT POWER UNIT UNTIL CHECK-OUT
AND START-UP PROCEDURES HAVE BEEN COMPLETED.

TOPSS Dimension Drawing


ALL WEI GHTS AND DI MENSI ONS ARE APPROXI MATE. Page: 11

Vous aimerez peut-être aussi