EVCEC-C2 Calibration and settings IPS Twin

Calibration and Settings IPS Twin


Revision: EVCEC-C2
Document N°: 774 8828
Release date: 05-2008 PT = Port
Auto configuration SB = Starboard
Auto configuration is the EVC system self-identifica-
When starting up for the first time the EVC system
display needs to be configured. * When starting up for the first time or after an update
the display will show “INCORRECT DATABASE”.
tion. Auto configuration should be performed when *Choose twin on an single EVC display system
the system is started for the first time or after system
EVC Control Panel updates. þ PORT ¨ PORT
UPLOADIN
Twin installation IMPORTANT! When using one EVC system ¨ STBD þ STBD


D display , the display must be configured as ¨ TWIN*
E “TWIN” before auto configuration is performed.
In case of using two EVC system display, the UPLOADING DATABASE

port display must be configured as “PORT”


and starboard display must be configured as
C “STBD” before auto configuration is performed.
F
B NOTE! The EVC system starts to download software
to all tachometers followed by the EVC system dis- 1 2 3 4 5 6 7 8 9 10
plays.
G
If the EVC system display has never been used be-
A fore “UPLOADING DATABASE” will be presented
when downloading software and all LEDs are off.
If the tachometer has never been used status bars


will be shown on the tachometer display. First the


A. NAVIGATION WHEEL “SOFTWARE” status bar will be shown and after-
Select: Turn navigation wheel to select sub wards the “ICON” status bar.
menu or select setting.
Enter: Push navigation wheel to reach se- Additional helm stations
lected submenu. Repeat step 11-15 for each helm station.
Confirm: Push navigation wheel to confirm
setting IMPORTANT!
11 12 13 14 15 16 17 18
Calibration mode entered when pushed to- Do not turn off the starter key until all helm sta-
gether with Back button (G). tion has been configured.
B. TACHOMETER DISPLAY SELECTION If PT shows on correct display skip these steps
(twin installations, port/starboard)
Indication LED(s) (red/green)
NOTE! LED(s) indicates which EVC system
tachometer/EVC system display the EVC con-
trol panel controls, port or starboard side.
C. NEUTRAL BUTTON
Confirming Lever calibration
Volvo Penta Lowspeed This applies to top mounted, twin in-
Powertrim override stallation
Warming up NOTE! The following description applies to Volvo
Indication LED(s) green Penta’s electronic controls.
- Constant light: Neutral NOTE! Both levers should be calibrated at the
- No light: FWD/REV same time, to give the same lever travel/positions
- Flashing: Calibration mode or Warming for both engines. Full
up mode throttle

D. ACTIVE STATION BUTTON


Activate helm station
1 2 3 4 5 6 7 8 9 10 11 12

Indication LED(s) red


- Constant light: Station active
- No light: Station inactive
- Flashing: Atempt to take station not per-
missible or boat steering wheel missing


E. STATION LOCK INDICATION
If lit, the system is locked and the engine can
only be controlled from the activated control
panel
F. MULTIFUNCTION BUTTON
Push to increase or decrease the instrument’s Full
throttle
and panel backlighting
- Dimmer
13 14 15 16 17 18 19 20 21
- Auto configuration (together with BACK BUT-
TON)
- Montoring helm (OEM-mode)
G. BACK BUTTON
Push to step backwards in the menu
- Menu structure OEM-mode Exit OEM
- Auto configuration (together with MULTI- NOTE! Always exit OEM-mode before changing mode

 
FUNCTION BUTTON) helm station.

Docking station panel 


C
D

1 2 3 4 5 1 2 3

B
E
A

Menu system
At power-up Volvo Penta logotype will be shown in
display. After a few seconds MAIN MENU will ap-
A. ALARM ACKNOWLEDGE BUTTON pear.
Acknowledge alarm Navigate MAIN MENU by turning NAVIGATION
Indication LEDs (red) WHEEL clockwise or counter clockwise. Push
Lit: Alarm (acknowledged) NAVIGATION WHEEL.
Flashing: Alarm (not acknowledged) or
Service mode
NOTE! Enter Service mode by pushing the IMPORTANT! For all setting procedures:
ALARM Activate helm station by pushing the ACTIVE
ACKNOWLEDGE BUTTON for at least 5 sec. STATION BUTTON on the EVC panel.
B. RESTART BUTTON
Push to start engines.
Indication LEDs (white)
Off: Engine off
Lit: Engine running
Flashing: Ignition on but engine off
C. ACTIVATION BUTTON
Activate helm station
Indication LEDs (red)
D. PADLOCK SIGN
E. STOP BUTTON
Push to stop all engines.

Joystick

B BOOST BUTTON
Push to enable boost mode.
Indication LED (red)

A DOCKING BUTTON
Push to enable docking func-
tion.
Indication LED (red)
Select language and units
Language
IMPORTANT!
Activate helm station by pushing the ACTIVE
STATION BUTTON on the EVC panel.


1 2 3 4 5 6 7 8 9

Units

1 2 3 4 5 6 7 8 9 10 11 12 13


14 15

Fuel tank settings

NOTE! For “Fuel multi-point calibration” and “Full


tank calibration”, please refer to ”Installation EV-
CEC-C2 Electronic Vessel Control, Volvo Penta
IPS”

IMPORTANT!
In case of one fuel tank this must be config-
ured on the port side. In case of two fuel tanks 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
the first must be configured on the port side
and the second one must be configured on the
starboard side.


IMPORTANT!
Activate helm station by pushing the ACTIVE
STATION BUTTON on the EVC panel.

16 17 18 19 20 21 22 23 24 25 26 27 28

Calibration of Volvo Penta


propulsion unit positions


Steering mode settings and
Joystick docking force
The setting of the steering mode, that is the IPS
propulsion units’ steering angles, is depending
on the properties of the boat hull. The steering
angles influence the turning radius of the boat.
1 2 3 4 5 6 7 8 9 10 11 12 13
There are three values when setting the steering
angles:
MINIMUM, MEDIUM and MAXIMUM.
MAXIMUM steering angle results in the smallest
turning radius.
NOTE! Perform a Steering mode setting if needed
after sea trial. Joystick docking force
For Volvo Penta IPS propulsion unit calibration The IPS Docking Force calibration is used when the force moving sideways must be changed.
procedures, please refer to ”Installation EVC - EC
Both the normal force mode and the high force mode will be changed with the same factor.
C2 Electronic Vessel Control, Volvo Penta IPS”. Choose between Minimum, Medium and Maximum.

Joystick calibration
This calibration only needs to be performed if

 
the boat movement does not corresponds to the
movement of the joystick
NOTE! Calibration only needs to be done in one
direction, port or starboard

1 2 3 4 5 6 7 8 9 10 11

Reset Calibra-
tion

7748828 05-2008