TCL= 107.

900

750
BCL= 107.150
POST TENSIONING SYSTEM OVM.M15A -12/-15/-19 BONDED

1425
1500
THE ANCHORING NICHES HAVE TO BE CLOSED SO THAT
105.725
R=19475MM
46
ANY ENTRY OF WATER WILL BE EXCLUDED.
R=20975MM EG.:

1075
104.650
1. ROUGHENING OF THE CONCRETE SURFACE.
45
GROUPS SCHEDULE OF TENDONS CUT SCHEDULE OF TENDONS 2. CLEAN UP SURFACES OF CONCRETE AND PAINTING WITH

875
103.775
EPOXY RESIN (150G/M² SURFACE OF FORMWORK).

8x 12 strands
44
3. CEMENT MORTAR MIXTURE 1:3 WITH SAND INCLUDING

725 775 825


102.950
AN EXPANDING AGENT.
INSIDE 43
102.175 OUTSIDE GROUPS GROUPS ONE GROUP OF TENDONS CONSISTS OF
TOTAL NUMBERS DUCTS LENGTH TOTAL LENGTH WEIGHT TOTAL WEIGHT 4. FILL IN OF CEMENT MORTAR.
42 MARKS OF TENDON NOS. OF TENDON
101.450
41 ATTENTION:

700
100.750 UNITS NUMBERS LENGTH [M] *) ØINS./ØOUTS.[MM] [M] [M] [KG/M] [KG] THE DEPTH OF ALL ANCHORING RECESSES TO BE 150MM.
40 LESS DEPTH WILL NOT BE ACCEPTED!

650
100.100
39 19 68.640M + 2X0.70M
1+3 2 2 4 100/105.5 70.040 280.160 20.938 5865.99

650
99.450
STRANDS =70.040M PRESTRESSING SYSTEM STRAND TENSIONING METHOD
38
OVM.M15A.

700
98.750
19 68.09M + 2X0.70M
37 2+4 2 STRANDS 2 =69.490M 4 100/105.5 69.490 277.960 20.938 5819.93 STEEL CHARACTERISTIC FPK= 1860 N/MM².

7x 15 strands
675
98.075
36 STRANDS AP=140MM².
625 97.450 15 67.500M + 2X0.70M
8-12 8 2 =68.900M 16 90/95.5 68.900 1102.400 16.530 18222.67 INDICATED LENGTHS OF TENDONS COUNT FROM FRONT FACE
35 STRANDS
600
96.850 OF ANCHOR PLATE TO FRONT FACE OF ANCHOR PLATE.
34 572-03-04-018 19 67.500M + 2X0.70M
13-31 19 2 38 100/105.5 68.900 2618.200 20.938 54819.87
575

96.275
STRANDS =68.900M
33 ALL TENDONS OF ONE HOOP TO BE TENSIONED
550

95.725
2 32 2 32-38 7
15
2
67.500M + 2X0.70M
14 90/95.5 68.900 964.600 16.530 15944.84
SIMULTANEOUSLY FROM BOTH ENDS (4 TENSIONING JACKS
600

95.125
STRANDS =68.900M ARE NECESSARY).
31
612

94.513
25550

12 67.500M + 2X0.70M

46x Y1860S7 / 140mm²


30 39-46 8 2 =68.900M 16 90/95.5 68.900 1102.400 13.224 14578.14 FOR POST TENSIONING PROCEED AS FOLLOWS:
575

93.938 STRANDS
29 93.388 AT FIRST ALL HOOPS 1, 3, 5, 15, 17, 19 ETC.
550

28 92.863
IN A SECOND STEP THE HOOPS 2, 4, 16, 18, 20 ETC.
525

27 92.350
115251.44
513

R=20450MM *) INCLUDING
450 26 91.850
HELIX :
TO BE CONFIRMED BY CIVIL CONSTRUCTOR
500

25
EXTRA LENGTH FOR JACKS 12 STRANDS =Ø270MM, REBAR DIAMETER =Ø16MM
91.350
500

R=20000MM
19x 19 strands

24
15 STRANDS =Ø300MM, REBAR DIAMETER =Ø16MM
90.850
500

270 180 23
19 STRANDS =Ø310MM, REBAR DIAMETER =Ø18MM
90.350
500

22 89.850
500

R=20270MM THE HELIXES HAVE TO BE SUPPLIED WITH ANCHOR


21 89.350
500

AXIS OF TENDONS BY SUPPLIER OF PRESTRESSING SYSTEM.


20 88.850
500

19 88.350
500

NUMBER OF ANCHORAGES:
18 87.850
2 UNITS TYPE OVM.M15A-12 STRANDS X 16 CABLES = 32UNITS
500

17 87.350 2 UNITS TYPE OVM.M15A-15 STRANDS X 30 CABLES = 60UNITS


500

16 86.850 2 UNITS TYPE OVM.M15A-19 STRANDS X 46 CABLES = 92UNITS


500

15 86.350
500

14 BY CONTRACTOR REQUIRED CONCRETE STRENGTH AT


85.850
PRESTRESSING FORCE AT ANCHOR TOTAL LENGTH ELONGATION ELONGATION
500

13 85.400 POST TENSIONING FCM0 = 35N/MM²


450

12 85.000 OF ELONGATION 1ST JACK 2ND JACK


400

11 84.600
(MM) (MM)
400

8x 15 strands

10 84.150 PA L
450

9 83.650
500

8 83.100 WALL T=1200MM


550

19 3800KN 420MM 210MM 210MM


7 82.500
STRANDS
600

6 (L=68640MM) NOTES: SYMBOLS:


600

81.900
150 300

TCL= 81.600
5 81.450
260 450

WALL T=1200MM - CONCRETE QUALITIES: CONCRETE REALISED


572-03-04-017
170

81.280 19
34
STRANDS
3800KN 414MM 207MM 207MM ACCORDING TO SYMBOLS.
WITH SLIDING FORMWORK
C 30/37 / F'C = 306 KG/CM²
12 81.020
strands

(L=68090MM) - STEEL REINFORCEMENT:


170

1 1
4x 19

80.850 CONCRETE CAST-IN-SITU

375 450 375


WALL T=450MM
- REBAR Ø < 16MM: Fy = 280 MPa.
- REBAR Ø ≥ 16MM: Fy = 420 MPa.
C 30/37 / F'C = 306 KG/CM²
NOMENCLATURE:
CONCRETE CAST-IN-SITU
19 3800KN 404MM 202MM 202MM - ANCHOR BOLTS: Q345B, C 25/30 / F'C = 255 KG/CM²
EL = EXCAVATION LEVEL
R=20825MM STRANDS
6400

1200 IF NOT SPECIFIED OTHERWISE. SLOPED CONCRETE


TCL = TOP CONCRETE LEVEL
R=19625MM - EMBEDDED STEEL PARTS: Q235B, C 25/30 / F'C = 255 KG/CM² BCL = BOTTOM CONCRETE LEVEL
WALL T=450MM IF NOT SPECIFIED OTHERWISE. BOF = BOTTOM OF FOUNDATION
15 3000KN 404MM 202MM 202MM LEAN CONCRETE
NGL = NATURAL GROUND LEVEL
STRANDS - CONCRETE COVER: C 12/15 / F'C = 122 KG/CM²

ACCORDING TO SPECIFICATIONS FFL = FINISH FLOOR LEVEL


CRUSHED LIMESTONE
ON REINFORCEMENT DRAWINGS. E.J. = EXPANSION JOINT
WALL T=450MM
TCL= 75.200 - ALL CONCRETE CORNERS TSL = TOP STEEL LEVEL
12 2400KN 404MM 202MM 202MM REFILL COMPACTED
STRANDS SHALL BE CHAMFERED TGL = TOP GRATING LEVEL
WITH A LENGTH APPROX. 25MM. TPL = TOP PLATE LEVEL FOR EMBEDS
PENDING
- DIMENSION IN MM, LEVELS IN M BPL = BOTTOM OF PLATE LEVEL
FOR EMBEDS
REVISIONS

SECTION 3 - 3 45°

NORTH
32° OF PLANT
572-03-04-017 / -018 SCALE 1:100

APPROVED ASTRONOMIC
FOR NORTH PREVAILING WIND
CONSTRUCTION 3 4
(MAINLY NORTHEAST)
2000
2800 A

5800
B

5200
2
0° 360° C
N

6300 23
11°
D
E
F
Approved Approved as Noted

4400 66
00
SUN PATH 45° G
For Information Revised as Noted

00 2600
14

30
00 H

05
Ø4 J

6
90°
By: RTM Date: 07/10/2018 00 0 K

36480
0m 32000

00
m L

04400
270°
M

APPROVED
2700 33
00

5 6

FOR

33746
180° 11°

CONSTRUCTION N 1000.600
1

E 836.620

3500
N

9000
KEY PLAN
3500
O
7000
7 8

SCALE 1:1000