NOTES:

1. ALL HARDWARE AND BRACKETS ARE FULL SCALE

00
.0
96

00
.0
96

5371 7805 ANGLE MOLDING


12' HD LINEAR CARRIER FOR 6"" MODULES 1.5" X 1.5"
5370
6440W1 6460W1 FACTORY APPLIED INTEGRAL CLIPS
12' HD LINEAR CARRIER FOR 4.5" MODULES
WOODWORKS LINEAR VENEERED PLANK WOODWORKS LINEAR VENEERED PLANK FACTORY APPLIED INTEGRAL CLIPS
NOMINAL 4.5" MODULE NOMINAL 6" MODULE
6640 6660
FSC CERTIFIED FSC CERTIFIED
0
25
5.

0
75
3.

5373 SNAP CLIP

6459BL RIGID ATTACHMENT CLIP (RAC)


5843 LINEAR SPLICE
XTAC
RC2BL
RADIUS CLIP FOR FACETED APPLICATIONS

AX4SPLICEB

6" AXIOM VECTOR

5948 MODIFIED TWIST CLIP

These drawings show typical conditions in which the Armstrong product depicted is installed. PROJECT NAME:
R

They are not a substitute for an architect's or engineer's plan and do not reflect the unique requirements of
local building codes,laws,statutes,ordinances,rules and regulations (Legal Requirements) that may be WOODWORKS LINEAR VENEERED PLANKS
applicable for a particular installation.
Armstrong Ceiling Solutions does not warrant, and assumes no liability for the accuracy or
DWG. NO. Master Assembly REV: - DATE: -
completeness of the drawings for a particular installation or their fitness for a particular
purpose. 11/30/2017 -
DATE: SCALE: 1 : 25 DESC.:
The user is advised to consult with a duly licensed architect or engineer in the particular locale of the
installation to assure compliance with all Legal Requirements.
Armstrong is not licensed to provide professional architecture or engineering design services. DRAWN BY: NJFriez CHK BY: -

ARMSTRONG CEILING SOLUTIONS * Lancaster, PA * Phone: 877-ARMSTRONG


WALL TO WALL INSTALLATION ISO WALL TO WALL INSTALLATION ISO

RCP - HANGER WIRE LOCATION - NON SEISMIC


MAIN BEAM TO WALL SECTION DETAIL PANEL TO WALL SECTION DETAIL PANEL TO SUSPENSION SYSTEM INTERFACE PANEL TO SUSPENSION SYSTEM INTERFACE

FRIST HANGER WIRE POINTS


MUST BE WITHIN 2' OF WALL

7805 ANGLE MOLDING


48.000

24.000 6.000

RCP - HANGER WIRE LOCATION - SEISMIC


XTAC ON EVERY MAIN
FLOATING INSTALLATION ISO TO WALL CONNECTION
FLOATING INSTALLATION ISO

MAIN BEAM TO FLOATING SECTION DETAIL CROSS TEE TO FLOATING SECTION DETAIL FLOATING TO WALL INSTALLATION ISO FLOATING TO WALL SECTION DETAIL

SEISMIC - FIRST HANGER WIRE


AX4SPLICEB POINTS MUST BE WITHIN 8" OF WALL
AX4SPLICEB

MODIFIED TWIST CLIP


48.000

XTAC

24.000 6.000

SEISMIC WALL TO WALL ISO

SEISMIC SIDE B
SEISMIC SIDE A
XTAC RCP - HANGER WIRE LOCATION - FLOATING - NON SEISMIC
XTAC

24.000

24.000

48.000

FLOATING TRIM

4.000
HANGER WIRE MUST BE
WITHIN 8" OF PERIMETER

BIOACOUSTIC INFILL PANEL ISO

WALL TO CEILING INSTALLATION SECTION DETAIL WALL INSTALLATION SECTION DETAIL

ACOUSTIC INFILL
These drawings show typical conditions in which the Armstrong product depicted is installed. PROJECT NAME:
R

They are not a substitute for an architect's or engineer's plan and do not reflect the unique requirements of
FURRING STRIP local building codes,laws,statutes,ordinances,rules and regulations (Legal Requirements) that may be WOODWORKS LINEAR VENEERED PLANKS
applicable for a particular installation.
Armstrong Ceiling Solutions does not warrant, and assumes no liability for the accuracy or
RIGID ATTACHMENT CLIP DWG. NO. Master Assembly REV: DATE: -
completeness of the drawings for a particular installation or their fitness for a particular
purpose. 11/30/2017
DATE: SCALE: 1 : 25 DESC.:
The user is advised to consult with a duly licensed architect or engineer in the particular locale of the
installation to assure compliance with all Legal Requirements.
DRAWN BY: NJFriez CHK BY: -
ACOUSTIC INFILL DETAIL Armstrong is not licensed to provide professional architecture or engineering design services.
SCALE 1/6

ARMSTRONG CEILING SOLUTIONS * Lancaster, PA * Phone: 877-ARMSTRONG