Vous êtes sur la page 1sur 2

(a) AwMœ‡ivwaZv (b)

MCQ MODEL TEST- 02 Zvc‡ivwaZv


(c) kã †ivaK (d) Av`ªZv †ivaK
1. BDjv‡ii w_Iwi Abyhvqx Dfq w`‡K Hinge I 12. Various activities of project are shown on bar
L ˆ`N¨© wewkó GKwU Kjv‡gi Cripling chart by (evi Pv‡U© †cÖv‡R‡±i Gw±wfwU
IRb n‡e- †`Lv‡bv nq-)
(a) P= (𝜋2E)/L2 (b) P= (𝜋2EI)/L (a) Horizantal line
(c) P= (𝜋2EI)/L2 (d) P= (𝜋EI)/L2 (b) Verticle line
2. ACI Code Abyhvqx slab G shirinkage / (c) Arrow
temparature reinforcement Gi maximum (d) circle
spacing KZ n‡e?
(a) 3 t (b) 4 inch
13. The pigment in paints is mixed to give
(c) 12 inch (d) 5 t desired (†cB‡›U wcM‡g›U wgkv‡bv nq
3. Diameter of a rivet in terms of plate thickness Avkvbyiæc....†c‡Z)
is (wi‡e‡Ui e¨vm †cø‡Ui cyiæ‡Z¡i KZ ¸Y A. smoothness B. colour
(a) D = 2 t (b) D = 4 t C. appearance D. durability
(c) D = 6 t (d) None
4. For effective drainage, the finished surface of 14. The wedge shaped unit (voussoir) placed at
flat roof should have a minimum slope- the crown of an arch, is called (Av‡P©i
(Kvh©Kix †Wª‡b‡Ri Rb¨ d¬¨vU Qv‡`i m‡ev©”P we›`y‡Z ¯’vwcZ f‡mŠi †K
b~¨bZg Xvj n‡e-)
(a) 1 in 20 (b) 1 in 10 e‡j)
(c) 1 in 5 (d) 1 in 50 A. skew back B. intrados
5. KY©vi ev‡ii †¯úwms Kvi †¯úwms Gi C. extrados D. keystone
mgvb 15. The angle which the line of nosing of the stair
(a) Main bar (b) Shriange bar
(c) Top bar (d) Minimum spacing makes with the horizontal, is called
6. Load factor Gi †ÿ‡Î wb‡Pi †KvbwU mwVK- (Abyf~wg‡Ki mv‡_ jvBb Ad †bvwRs
(a) 1.2×D.L +1.6×L.L m„ó †KvY‡K e‡j-)
(b) 1.4×D.L +1.6×L.L A. riser B. flier
(c) 1.4×D.L +1.7×L.L C. soffit D. pitch or slope
(d) 1.2×D.L +1.7×L.L 16. cøv÷vi KvR wKDwis b~b¨Zg mgqKvj
7. Dfq cÖvšÍ Ave× Kjv‡gi Effective length A. 18 NÈv-7 w`b B.
18 NÈv - 15 w`b
factor, K Gi gvb KZ- C. 18 NÈv -24 w`b D. 24 NÈv - 15 w`b
(a) 0.65 (b) 0.75
17. 3 wgwg cyiæ 1 eM©wgwgUvi Kvu‡Pi IRb
(c) 0.8 (d) 0.85
KZ
8. Pure Buckling occurs in a ( wcIi evKwjs N‡U)
(a) 8 †KwR (b) 8.07 †KwR
(a) Short column
(c) 9 †KwR (d) 9.07 †KwR
(b) Medium Column
18. Kbwµ‡U GwMÖ‡MU _v‡K †gvU AvqZ‡biÑ
(c) Long column
(a) 60% (b) 65%
(d) None (c) 70% (d) 75%
9. A column that fails due to direct stress, is 19. which of the following is the purest form of
called-. (wW‡i± wkqv‡i e¨_© Kjvg‡K e‡j-) iron..(wb‡Pi †KvbwU ‡jvnvi wbLv`
(a) short colum (b) long column
MVb..)
(c) weak column (d) medium column
(a) cast iron (b) wrought iron
10. 2. 1 Mpa mgvb KZ Kg/cm2
(c) mild steel (d) high carbon steel
(a) 10.2 Kg/cm2 (b) 145 Kg/cm2
20. B¯úvZ‡K k³ Ki‡Z †KvbwUi cÖfve
(c) 0.00689Kg/cm2 (d) 9.81 Kg/cm2
me‡_‡K †ekx-
11. _vg©vj Bbmy‡jwUs g¨v‡Uwiqvjm Gi †Kvb
(a) Kve©b (b) dmdivm
¸YwU _vKv Avek¨K-
(c) Kcvi (d) wmwjKb
21. Kve©‡bi GKwU we‡kl iæc n‡jv-
(a) nxiK (b) B¯úvZ
(c) ‡÷Bb‡jm w÷j (d) gvBì w÷j
22. 1 NbwgUvi (10×8) †m.wg mvB‡Ri Kv‡Vi
ˆ`N¨© KZÑ
(a) 115 wgUvi (b) 120 wgUvi
(c) 125 wgUvi (d) 130 wgUvi

Vous aimerez peut-être aussi