§I. Technical Parameter
A/D Conversion ∑-⊿
Input Signal Range 0 ~ 10 mV
A/D Resolution 1,000,000
A/D Conversion Speed 10times/second
Excitation Voltage DC5V
Excitation Current 4 * 350 Ohm load cells
8 * 700 Ohm load cells
Display 17 digits 0.56” LED
Divisions 1/2/5/0.1/0.2/0.5/0.01/0.02/0.05/0.001/0.002/0.005/10/20/50/
100/200/500 (0.10/0.20/0.50/0.010/0.020/0.050 optional)
Serial Output Interface RS232 continuous transmitting, and RS485 optional
Baud Rate 1200 2400 4800 9600 optional
Printing RS232 printing output
AC Power AC220V50Hz (AC/DC built-in battery 6V 4Ah)
Operating Temperature 0℃~40℃
Storage Temperature -25℃~55℃
Relative Humidity ≦85﹪RH
Exterior Size 256mm * 160mm * 130mm
Weight Around 2 kg
§II. Connection
1. The load cell adopts D 9-pins socket as follows:

GND +E
Indicator Load cell
+E 1 +Excitation
-E 2 +Signal
+S 3 -Signal
-E +S
-S 4 -Excitation

-S

2. Communication Connection (D-SUB-9-pins):


3rd pin:TXD (RS-232 Continuous transmitting) 5th pin:GND
3. Communication Data Format (RS-232C continuous transmitting)
The communication Adr= 00 continuous transmitting the weight and the format is

-1-
=,X1,X2,X3,X4,X5,X6,X7,S. X1,X2,X3,X4,X5,X6,X7 is the displayed data, and “ = ”is the separating
digit, S is the symbol digit.
Example: weight: -123.45kg kg, it will transmits: =54.3210-=54.3210-…….
The communication Adr= 99 continuous transmitting the weight and the format is
=S,X7,X6,X5,X4,X3,X2,X1.
Example: weight: -123.45kg kg, it will transmit: =-0123.45=-0123.45…….
The communication Adr= 98 continuous transmitting the amount or quantity.
(It will transmit amount when used as price computing, and will transmit quantity when used as counting.)
The format is =,X1,X2,X3,X4,X5,X6,X7,B X1,X2,X3,X4,X5,X6,X7 is the displayed data,
and “ = ”is the separating digit , B is the blank.
Example: amount: 123.45, it will transmit: =54.3210 =54.3210 …….
Quantity: 12345, it will transmit: =543210 =543210 …….
4. RS-485 can be added under requirement.
§III. Button Functions, Display and Indication Light

7 8 9 ①

4 5 6 C

1 2 3

SET 0 Enter

①: ON/OFF SET: Setting unit price or weighting.


Enter: Input the date : Accumulation, Printing
: Zero, Tare 0—9: Number keys
C: Price computing/counting conversion, unit price or weight housing
Weight value at the first line,unit price/weight at the second line, total sum/quantity at the third line.
Indication Light:
〖P〗 Price Computing Function 〖C〗 Counting Function
〖AC〗 AC power supply 〖 〗 Low Power
〖◣◢〗 Weighing Stably 〖→T←〗 Tare, present weight value is net weight
〖→0←〗 Zero
§IV: Parameter Setting:
1. Connect the load cell, set the indicator at the normal weighing status.
2. Set the parameters as per the following procedures
(You have to set the short circuit loop at the correct position.)
3. Press【Enter】key to confirm, then you will go to the next step.
Step Operation Display Explanation
1 Press【→0←】 〖000000〗→ When it is switched off, turn on the ON/OFF key.
Press【①】 〖999999〗→ At the back of the indicator, keep pressing 【→0←】 key, at the
〖 0〗

-2-
same time, press 【①】 key, then you can set the parameter and
make the calibration.
2 Press【SET】 〖------〗
〖-Set-〗 Input the password
〖------〗

3 Press【2003】 〖------〗 Input password (2003), you will go into the Parameter setting
〖-Set-〗 status.
〖 2003〗

4 Press【Enter】 〖 1〗
〖-d-〗 Set division
〖 1〗
5 Press【C】 〖 2〗 0.001-0.002-0.005-10-20-50-100-200-500-0.10-0.20-0.50-1-2
Press【C】 〖 5〗 -5-0.1-0.2-0.5-0.01-0.02-0.05
Press【C】 〖 0.1〗
For example:d=0.1
6 Press【Enter】 〖006000〗 Set full capacity
〖-FS-〗
Press【3000】 〖006000〗
〖 3000〗
For example, the full capacity is 3000.
7 Press【Enter】 〖 0〗 0-2: filter parameter, the smaller this figure is, the faster the
〖-FLt-〗 speed is, the larger this figure is, and more stable it is.
〖 0〗
You can choose the small figure, when weighing condition is
good, you can choose large figure, when weighing condition is
poor.
8 Press【1】 〖 0〗
〖-FLt-〗 For example: filter parameter FLt =1
〖 1〗
9 Press【Enter】 〖 10〗 The Ones digit represents the energy saving function:
〖AUtP 〗 The Ones digit =0: the energy saving function is not available.
〖 10〗
The Ones digit =1: the energy saving function is available.
The Tens digit represents zero tracking range (0-9):
0:0.4 d 1:0.8 d 2:1.2 d 3:1.6 d 4:2 d 5:2.4 d
6:2.8 d 7:3.2 d 8:3.6d 9:4 d
Also, the Tens digit represents zero range at turning on.
The Tens digit=0: there is not zero at turning on.
The Tens digit> 0: the zero range is 20%FS at turning on.
10 Press【11】 〖 10〗 For example:AUtP=11
〖AUtP 〗 Energy saving function is available.
〖 11〗
Zero tracking range is 0.8d, zero range at turning on is 20%FS.
11 Press【Enter】 〖 01〗 Choosing the communication address:
〖-Adr-〗 Adr=00 : the continuous serial output: in reverse sequence
〖 01〗

-3-
Adr=99 : the continuous serial output: in right sequence
Adr=98 : amount/ quantity
Adr=01-97: serial printing output
Address range: 00-99
12 Press【Enter】 〖 2400〗
〖bAUd 〗 Baud rate choice: 2400→4800→9600
〖 2400〗
13 Press【C】 〖 4800〗 For example:b=4800
14 Press【P】 〖 0〗 Mode chose when power on:
〖P - c〗 0— Price computing
〖 0〗
1— Counting
Eg:0
15 Press【P】 〖 0〗 Decimal point(in total amount window) chose: 0-4
〖P - c〗 0—NONE
〖 0〗
1-4—0.0 0.00 0.000 0.0000
16 Press【Enter】 〖 0.0〗
〖 0.00〗 The parameter setting is over.
〖 0.00〗
§V. Calibration:
If you just set the parameters, and do not turn it off, you can directly go into the calibration mode:
Step Operation Display Explanation
1 Press【SET】 〖------〗
〖SEt 〗 Input the password
〖------〗
2 Press【8888】 〖 8888〗 Input the calibration password: 8888
3 Press【Enter】 〖n LOAd〗 Enters Calibration mode
〖CAL 0〗 Ready to make zero calibration.
〖0XXXXX〗
0XXXXX:A/D Internal code value
4 Make platform 〖------〗 It is making zero calibration.
empty, then press 〖CAL 0〗
【Enter】 〖------〗
It will show FS 〖 LOAd 〗 Ready to make FS calibration.
after a few 〖CAL 〗
seconds. 〖003000〗
5 Load the poise, 〖------〗 It is making weighing calibration.
input the value of 〖CAL 〗
the poise, then 〖Poise value〗
press【Enter】
〖 300.0〗 It will show the value of the poise loaded on the
〖 0.00〗 platform in a few seconds, then the calibration is over.
〖 0.00〗
§VI. Operation

-4-
1. Turning On/Turning Off
Press 【①】key at the back of the indicator, it will be switched on, keep pressing 【①】 key for 2 seconds,
it will be switched off.
After it is on, press 【①】 key, you will stop the other operations, and go back to the weighing mode.
2. Zero
Press 【→0←】key for 2 seconds when the load <2%F.S, it will display 0, and the 〖→0←〗 light is on.
3. Tare
a) Tare the weight: When 〖→T←〗 light is off, the display ﹥0, and the display is stable, press
【→0←】key, the display will be 0, and 〖→T←〗 light will be on。
b) cancel the tare : When 〖→T←〗 is on, press 【→0←】 key ,cancel the tare, and 〖→T←〗
light will be off.
4. Data Accumulation And Printing:

When the load﹥20d, and is stable, press【 】 key, it will make accumulation, and the first line of display

will show the accumulated weight, the second line shows the accumulation times, the third line shows the
accumulated amount. It will return back to the weighing mode after 1 second. It will accumulate the weight
and quantity when it is in counting mode.
Note: you can only accumulate the weighing data one time, when you remove the first load, and make
sure that the display < 20d, then load the second Weight, then you can accumulate this second weight.
If the printing is available at this time (Adr=01~97), you can print the date with the serial printer in the
following format:
Price Computing: Counting:
No: 0016 (times) No: 0012 (times)
G: 10.00kg(GW) G: 52.01kg(GW)
T: 3.00kg (tare) T: 2.01kg (Tare)
N: 7.00kg (NW) N: 50.00kg(NW)
P: 1.23$ (U.P.) U: 21.322kg(weight/10000pcs)
S: 8.61$ (Amount) C: 2345p (Quantity)
5. Accumulation Checking, Printing And Canceling:

Keep pressing 【 】> 2 seconds,the first line will show accumulated times, the second line and the third

line will show accumulated amount and accumulated quantity, pressing 【C】, you can get the accumulated

weight. If you press【 】 at this time, you can print out the accumulated value , the format is as follows,

then you press【→0←】, you can cancel the accumulation.


For example:
Accumulated Amount Accumulated Times Accumulated Weight
〖n 123〗 〖n 102〗 〖n 102〗
〖S 2〗 〖C 1〗 〖 23〗
〖2301.20〗 〖021389〗 〖0012.85〗
Example for printing:

-5-
Price computing: Counting:
No: 0018 (accu. times) No: 0018 (accu. times)
W: 1926.72kg(accu. weight ) W: 215.72kg(accu. weight)
S: 2369.87$(accu. amount) C: 891213p(accu. quantity)
6. Price Computing/Counting Shifting:
Press 【C】>2 seconds, you can shift between price computing and counting, the light P means that it is in
price computing mode, the light C means it is in counting mode.
7. Price Computing:
a) Input price: If the price is 1.23, you can input 【1】【2】【3】。
If the interval is more than 5 seconds, you have to input the price again.
Press 【Enter】key, you can input the price again.
b) Storing price:Press 【SET】+numerical key+【Enter】
, you can store the current price.
If you want to store the price of 1.23 in Memory 2, you can press 【SET】
【2】
【Enter】
, then 1.23 will be stored in Memory 2. The indicator can store 28 prices, that is, Memory 1-28.
Note: You can not make this operation at the parameter setting mode.
c) Price calling: To call the stored price, you can press【C】+numerical key +【Enter】.
For example, if you want to call the price stored in Memory 3, you can press 【C】
【3】
【Enter】

8. Counting:
a) Weight input: load the items on the platform, it is better that you load the items in bigger
quantity, then input the total quantity number of the items on the platform, then press 【Enter】. For example,
if the quantity for the items are 123pcs, you can input 【1】【2】
【3】
【Enter】。
b) Storing weight :Press 【SET】+numerical key+【Enter】, you can store the current weight. If
you want to store the weight in Memory 2, you can press 【SET】
【2】
【Enter】, then this weight will be
stored in Memory 2. The indicator can store 28 weights, that is, Memory 1-28.
Note: You cannot make this operation at the parameter setting mode.
c) Weight calling: To call the stored weight, you can press【C】+numerical key +【Enter】.
For example, if you want to call the weight stored in Memory 3, you can press 【C】
【3】【Enter】.
9. Battery Volume:
Press 【Enter】>2 seconds at weighing mode, it will show the battery volume, press 【Enter】, it will return.
10. Charging indication:
When battery volume < 20 % , 〖 〗 light will be on, you should charge at this time.
11. Discharging protection:
When battery volume < 10%, it will be switched off automatically to prevent discharging.
12. Energy saving mode:
When energy saving function is available, if non weighing operation lasts For more than 5 minutes, it will
show 〖- 〗 to save the energy.
13. Automatic turning off:
When energy saving function is available, if non weighing operation lasts for more than 30 minutes, it will
be switched off automatically.
14. Working time:

-6-
If you fully charge the built in 4AH battery, It can work 20 hours continuously.
§VII. Maintenance and Notices:
2. Do not use the indicator under strong sunlight for protecting the using life of it. Keep it on flat while using.
2. Do not use it in the places full with dust and strong vibration.
3. Do not overload (including the tare weight) (more than full scale is prohibited.).
4. Do not cleanout the case with strong impregnate (such as, benzene, nitric acid oile, etc.)
5. Keep the interior part of indicator away from the water for avoiding the damage to the electrical components
and electronic shock to people.
6. Switch off the power when some problem happened while in operation. The user (non-manufacturer of scales)
please send the indicator to our company for repair, and it is not allowed to repair at will for avoiding more
damage to the indicator.
7. The indicator will charge the battery automatically while the AC power is connected.
8. The short circuit loop is with the indicator, you can check the indicator with the short circuit loop,
instead of checking the indictor with load cell. If the display is abnormal when connecting the load cell,
you can turn off the indicator, take out the plug of the load cell, fix the short circuit loop, then turn on
the indicator, and then it will make self checking 0-9:
a) The display is stable, meaning the indicator is good.
b) The display is stable, meaning the indicator is with problem.
§VIII. Repair Guarantee & Service
(Please send back to our company for repair guarantee and service)
The repair guarantee time is 1 year from the selling date of this indicator, and the problem should be
happened due to the problem of the indicator itself while in right operation (not due to wrong operation). We
supply the service to the indicator for life. (★Battery exclude the repair guarantee)
★Note: The repair guarantee not responsible for all problem of the weighing system while our indicator
only act as a part of this system, we only take charge of the problem caused from the indicator itself.
§IX. Abnormal Display
〖 OUEr〗-------weight value> 100 % F·S + 9 d
〖-OUEr〗-------weight value negative overflow
〖 〗 -------The battery volume <20%, please connect with AC power for charging immediately.