Académique Documents
Professionnel Documents
Culture Documents
From Tekla/Analysis select the pull down menu called NEW MODEL.
Press NEW
More settings
Allows the user to activate a secondary windows with more advanced options
Note:
The other TABS called Analysis , jobs are not used by the procedure
The analysis option , in particular the seismic options must be input directly using Midas Gen.
Press EXPORT
The procedure asks to activate or Not the load combination generator
Select NO
Select OK
In case of errors during the MXT file generation the following message could be showed
The LOG review the list of errors (the file is saved in the C:/TEKLASTRUCTURES MODELS)
Import the A&D model in Midas, complete the FEM model , run and design
Note:
In case of an ERROR Midas/Gen stops the import procedure. The User must check the messages
and restart the procedure from Tekla S.
An ERROR typically comes from the following reasons:
In case of a WARNING the procedure continues . A WARNING typically comes from the following
reasons:
- Overlapped elements
- complete the MIDAS model (input loads, analysis options, etc)
- perform the analysis and design
- change the cross sections that not satisfy the checks
- Select FILE/EXPORT /see the following image)
Note:
The name of the model must be the same of the name before imported. The file extension must
be MXT
- Confirm with Save in order to overwrite the previous MXT file used
Recovery of Cross section changes in Tekla S
Deleted Members
The list of element deleted in Midas/Gen that must be removed in Tekla S.
Profile Changes
The list of the cross section changed that must be updated in Tekla S.
From Midas Gen / Civil to Tekla Structures
From Midas/Gen
Note:
The file must have an .Mxt extension and must be saved in Tekla S. working folder , under the
ANALYSIS folder of the model
For example:
From Tekla S.
- open a new model
- open a new A&D model .
- Press NEW
- select Get results command and wait for the procedure termination