Siemens Superbreed Cage Motors are suitable for the most diverse applications. The Motors
are available in the wide range from frame sizes 63 to 355M and they conform to EFF2
standards for efficiency. These motors have a high efficiency and high uptime. Consequently
the productivity is higher and energy consumption lower. The motors have low life cycle costs,
hence great saving!!!
This datasheet deals specifically with motors from frame sizes 160M to 355L.
s
3~Ind. Mot 1LA0253–4YA80 IS:325
No.N8 / 425440 Frame 250M Ins.Cl. F
%Eff 93.8 IP 55 Duty S1 Amb.45OC
IEC 60034–1
Hz V kW A rpm pf.
50 415 55 96 1480 0.85
± 5% ± 10%
MADE IN INDIA
2
Motors of international design and quality
Protection
Motors have IP55 degree of protection
as a standard feature. This degree of
protection conforms to IS: 4691. All
motor, which have a shaft extension
pointing upwards, must have a means
(provided by the user) of preventing the
ingress of liquids along the shaft.
For all motors with the shaft end
pointing downwards, the version ‘with
canopy’ is recommended.
3
Energy Saving, Cost Saving
Earthing Terminals
All motors are provided with 4 earthing
terminals, two in the terminal box and
one on each foot.
Efficiency
IMB3 160M-355L
Efficiency of motors conforms to “EFF2”
values and remains unchanged from
100% to 60% of rated output utilisation. IMB5 160M-315M2)
IMB35 160M-355L
160M-280M
IMV5* without canopy
315M, 315L1)
160M-280M2)
IMV1 without canopy
315M-355L1)
4
Converter Operation Bearing System It is advisable to check the permitted
1LA0 motors for use with converters Frames upto 225M have pre-lubricated bearing loads.
can be offered with dielectrically bearings as a standard feature but If high cantilever forces are exerted at
strengthened special insulation regreasing facility can be provided on the drive end, e.g. owing to belt
impregnation. To avoid damage from request. Frames 250 and above are transmissions, motors can be fitted with
bearing currents, insulated bearing equipped with regreasable bearings as a strengthened / appropriate bearings on
arrangement at the NDE is standard feature. request.
recommended for frame sizes 280 and
above.
Bearing Data, for direct coupled motors
Note: For Constant Torque application,
please refer to us for calculations and Bearing Type
selection. Motor Horizontal Vertical
Frame Type Poles Construction Construction
Re-rating factors size 1LA0
Drive end Non-Drive Drive end Non-Drive
The re-rating factors applicable under end end
different conditions are as follows.
160 M,L 16 2...8 6209 C3 6209 C3 6209 C3 6209 C3
Altitude of Location 180 M,L 18 2...8 6210 C3 6210 C3 6210 C3 6210 C3
Altitude above Permissible
Mean Sea Level Output as % of 200 L 20 2...8 6212 C3 6212 C3 6212 C3 6212 C3
in Metres Rated Value
225 S,M 22 2...8 6213 C3 6213 C3 6213 C3 6213 C3
1000 100
250 M 25 2...8 6215 C3 6215 C3 6215 C3 6215 C3
1500 97
2 6216 C3 6216 C3 6216 C3 6216 C3
280 S,M 28
2000 94
4...8 6317 C3 6317 C3 6317 C3 6317 C3
2500 90
2 6217 C3 6217 C3 6217 C3 6217 C3
315 S,M 310,313
3000 86
4...8 6319 C3 6319 C3 6319 C3 6319 C3
3500 82 2 6217 C3 6217 C3 6217 C3 7217 B
315 L 316,317
4000 77 4...8 6319 C3 6319 C3 6319 C3 6319 C3
Variation in supply voltage and frequency Packing Case Dimensions For “1LA” motors
Combined Permissible Packing Case Dimensions
Voltage Frequency Voltage and Output as % of L x B x H (mm) for
Variation % Variation % Frequency Rated Value For Motor
Variation % Foot Mounted Motor
Flange
±6 ±3 ±9 100 Frame T. Box on T. Box on Motor
Type
Size Top side
±10 ±5 ±10 100
160 1LA0 16 850x494x642 970x649x682 840x600x600
±12.5 ±5 ±12.5 95
5
Selection and Ordering Data
3000 rev/min. 2-Pole. 415V ±10%, 50Hz ±5%, Combined V and F 10%, Ambient 45OC. IP55. Class F Insulation.
Locked Locked Break-
Rated Frame Order No. Operating characteristics at rated output rotor rotor down Rotor GD2 of Weight
Output size (for Order No. current torque Torque Class rotor approx.
suffixes for
voltage and type Rated Efficiency Power Rated Rated
of construction, Current Factor Speed Torque For direct-on-line starting as
see table below) at 415V multiples of rated
11 15 160M 1LA0 163-2YC.. 20 88.0 0.88 2910 3.7 6.0 1.8 2.5 10 0.20 100
15 20 160M 1LA0 164-2YC.. 26 89.5 0.88 2910 5.0 6.0 1.8 2.5 10 0.22 115
18.5 25 160L 1LA0 166-2YC.. 32 90.5 0.88 2910 6.2 6.0 2.1 2.5 10 0.26 130
22 30 180M 1LA0 183-2YA.. 38 91.5 0.87 2940 7.3 6.5 2.4 3.0 16 0.31 165
30 40 200L 1LA0 206-2YB.. 51 92.5 0.88 2950 9.9 6.0 2.1 2.7 13 0.56 230
37 50 200L 1LA0 207-2YB.. 63 92.5 0.88 2950 12.2 6.0 2.1 2.7 13 0.64 250
45 60 225M 1LA0 223-2YB.. 76 93.7 0.88 2955 14.8 6.0 2.1 2.7 13 0.96 310
55 75 250M 1LA0 253-2YB.. 92 93.5 0.89 2970 18.0 7.0 2.1 2.7 13 1.80 415
75 100 280S 1LA0 280-2YC.. 126 94.2 0.88 2970 24.6 7.0 1.9 2.7 10 3.16 570
90 120 280M 1LA0 283-2YC.. 149 94.6 0.89 2970 29.5 7.0 1.9 2.7 10 3.68 610
110 150 315S 1LA0 310-2YC.. 181 94.8 0.89 2980 36.0 7.0 1.8 2.7 10 5.20 790
132 180 315M 1LA0 313-2YC.. 217 95.2 0.89 2980 43.1 7.0 1.8 2.7 10 6.00 850
160 215 315L 1LA0 316-2YC.. 258 95.7 0.90 2985 52.2 7.0 1.8 2.7 10 7.20 990
200 270 315L #1LA0 317-2YC.. 323 95.7 0.90 2985 65.3 7.0 1.8 2.7 10 9.20 1100
250 335 355L 1LA0 356-2YC.. 397 96.2 0.91 2985 81.6 7.0 1.6 2.8 10 13.20 1470
315 425 355L 1LA0 357-2YC.. 500 96.3 0.91 2985 102.8 7.0 1.6 2.8 10 16.00 1650
1500 rev/min. 4-Pole. 415V ±10%, 50Hz ±5%, Combined V and F 10%, Ambient 45OC. IP55. Class F Insulation.
Locked Locked Break-
Rated Frame Order No. Operating characteristics at rated output rotor rotor down Rotor GD2 of Weight
Output size (for Order No. current torque Torque Class rotor approx.
suffixes for
voltage and type Rated Efficiency Power Rated Rated
of construction, Current Factor Speed Torque For direct-on-line starting as
see table below) at 415V multiples of rated
11 15 160M 1LA0 163-4YA.. 21 89.2 0.81 1450 7.4 6.5 2.8 2.8 16 0.22 105
15 20 160L 1LA0 166-4YA.. 29 90.2 0.81 1450 10.1 6.5 2.8 2.8 16 0.26 130
18.5 25 180M 1LA0 183-4YA.. 34 91.3 0.83 1463 12.3 6.0 2.5 2.5 16 0.52 165
22 30 180L 1LA0 186-4YA.. 40 91.7 0.83 1460 14.7 6.0 2.5 2.5 16 0.60 180
30 40 200L 1LA0 207-4YA.. 54 92.5 0.84 1470 19.9 6.5 2.5 2.5 16 0.96 240
37 50 225S 1LA0 220-4YA.. 64 93.5 0.86 1475 24.4 6.0 2.5 2.5 16 1.91 310
45 60 225M 1LA0 223-4YA.. 78 93.6 0.86 1475 29.7 6.0 2.5 2.5 16 2.16 335
55 75 250M 1LA0 253-4YA.. 96 93.8 0.85 1480 36.2 6.0 2.5 2.5 16 3.20 435
75 100 280S 1LA0 280-4YA.. 130 94.5 0.85 1485 49.2 6.0 2.5 2.5 16 5.60 610
90 120 280M 1LA0 283-4YA.. 155 95.0 0.85 1485 59.0 6.0 2.5 2.5 16 6.40 660
110 150 315S 1LA0 310-4YA.. 189 95.5 0.85 1485 72.1 6.0 2.5 2.5 16 8.80 830
132 180 315M 1LA0 313-4YA.. 226 95.7 0.85 1485 86.6 6.0 2.5 2.5 16 10.80 910
160 215 315L 1LA0 316-4YA.. 270 95.8 0.86 1485 104.9 6.0 2.5 2.5 16 12.80 1060
200 270 315L #1LA0 317-4YA.. 336 96.2 0.86 1485 131.2 6.0 2.5 2.5 16 16.80 1200
250 335 355L 1LA0 356-4YB.. 420 96.2 0.86 1488 163.6 6.5 2.1 2.5 13 24.00 1590
315 425 355L 1LA0 357-4YB.. 529 96.3 0.86 1488 206.2 6.5 2.1 2.5 13 29.60 1790
Temperature rise limited to Class B for all motors except those marked # (values subject to tolerance as per IS : 325)
# Temperature rise limited to Class F For 11kW, 2-pole “EFF 2” motors select 1LA0 164-2YC..
6
Selection and Ordering Data
1000 rev/min. 6-Pole. 415V ±10%, 50Hz ±5%, Combined V and F 10%, Ambient 45OC. IP55. Class F Insulation.
Locked Locked Break-
Rated Frame Order No. Operating characteristics at rated output rotor rotor down Rotor GD2 of Weight
Output size (for Order No. current torque Torque Class rotor approx.
suffixes for
voltage and type Rated Efficiency Power Rated Rated
of construction, Current Factor Speed Torque For direct-on-line starting as
see table below) at 415V multiples of rated
7.5 10 160M 1LA0 163-6YB.. 15 87.0 0.78 955 7.6 5.5 2.1 2.5 13 0.22 105
11 15 160L 1LA0 166-6YB.. 22 88.5 0.80 955 11.2 5.5 2.1 2.5 13 0.28 130
15 20 180L 1LA0 186-6YA.. 30 89.5 0.79 970 15.1 6.0 2.5 2.3 16 0.80 170
18.5 25 200L 1LA0 206-6YA.. 36 90.5 0.78 975 18.5 6.0 2.5 2.3 16 1.16 220
22 30 200L 1LA0 207-6YA.. 42 91.2 0.79 975 22.0 6.0 2.5 2.3 16 1.32 235
30 40 225M 1LA0 223-6YA.. 56 92.0 0.81 978 29.9 6.1 2.5 2.3 16 2.28 305
37 50 250M 1LA0 253-6YA.. 68 92.7 0.82 980 36.8 6.1 2.3 2.3 16 3.56 410
45 60 280S 1LA0 280-6YA.. 80 93.0 0.84 984 44.5 6.5 2.4 2.3 16 5.20 540
55 75 280M 1LA0 283-6YA.. 97 93.5 0.84 984 54.4 6.5 2.4 2.3 16 6.00 580
75 100 315S 1LA0 310-6YA.. 131 93.7 0.85 985 74.2 6.0 2.3 2.5 16 9.60 770
90 120 315M 1LA0 313-6YA.. 160 94.4 0.83 988 88.7 6.5 2.4 2.5 16 11.60 830
110 150 315L 1LA0 316-6YA.. 190 94.7 0.85 985 108.8 6.0 2.3 2.5 16 14.00 970
132 180 315L 1LA0 317-6YA.. 228 94.7 0.85 985 130.5 6.0 2.3 2.5 16 17.20 1060
160 215 355L 1LA0 356-6YB.. 275 95.4 0.85 988 157.7 6.0 2.1 2.3 13 24.00 1460
200 270 355L 1LA0 357-6YB.. 343 95.5 0.85 988 197.2 6.0 2.1 2.3 13 30.00 1580
250 335 355L 1LA0 358-6YB.. 428 95.7 0.85 988 246.5 6.0 2.1 2.3 13 36.40 1790
750 rev/min. 8-Pole. 415V ±10%, 50Hz ±5%, Combined V and F 10%, Ambient 45OC. IP55. Class F Insulation.
Locked Locked Break-
Rated Frame Order No. Operating characteristics at rated output rotor rotor down Rotor GD2 of Weight
Output size (for Order No. current torque Torque Class rotor approx.
suffixes for
voltage and type Rated Efficiency Power Rated Rated
of construction, Current Factor Speed Torque For direct-on-line starting as
see table below) at 415V multiples of rated
5.5 7.5 160M # 1LA0 164-8YB.. 13 84.5 0.72 710 7.5 4.5 1.9 2.3 13 0.22 105
7.5 10 160L 1LA0 166-8YB.. 17 85.5 0.72 710 10.3 4.5 1.9 2.3 13 0.28 130
11 15 180L 1LA0 186-8YB.. 25 87.5 0.71 725 14.8 5.0 2.0 2.2 13 0.84 175
15 20 200L 1LA0 207-8YB.. 31 89.0 0.76 725 20.2 5.0 2.0 2.2 13 1.48 245
18.5 25 225S 1LA0 220-8YB.. 36 90.5 0.78 725 24.9 5.0 1.9 2.2 13 2.32 300
22 30 225M 1LA0 223-8YB.. 45 90.5 0.76 728 29.4 5.2 2.0 2.2 13 2.64 325
30 40 250M 1LA0 253-8YB.. 57 92.0 0.80 730 40.0 5.0 2.1 2.2 13 4.40 435
37 50 280S 1LA0 280-8YB.. 69 92.0 0.81 732 49.2 5.5 2.1 2.2 13 5.60 550
45 60 280M 1LA0 283-8YB.. 83 92.5 0.82 732 59.9 5.5 2.1 2.2 13 6.40 600
55 75 315S 1LA0 310-8YB.. 102 92.5 0.81 737 72.7 5.5 2.1 2.4 13 9.20 740
75 100 315M 1LA0 313-8YB.. 137 93.0 0.82 737 99.1 5.5 2.1 2.4 13 12.00 850
90 120 315L 1LA0 316-8YB.. 163 93.5 0.82 737 118.9 5.5 2.1 2.4 13 14.40 990
110 150 315L 1LA0 317-8YB.. 199 94.0 0.82 737 145.4 5.5 2.1 2.4 13 17.60 1100
132 180 355L 1LA0 356-8YB.. 240 94.5 0.81 738 174.2 6.0 2.1 2.2 13 24.80 1440
160 215 355L 1LA0 357-8YB.. 291 94.5 0.81 738 211.2 6.0 2.1 2.2 13 30.00 1580
200 270 355L 1LA0 358-8YB.. 362 95.0 0.81 740 263.2 6.0 2.1 2.2 13 37.20 1790
Temperature rise limited to Class B for all motors except those marked # (values subject to tolerance as per IS : 325)
# Temperature rise limited to Class F
7
Dimensions in mm
8
Construction : IMB3, IMB6, IMB7, IMB8, IMV5, IMV6
9
Dimensions in mm
10
Construction : IMB5, IMV1
11
Special Designs
• Non-standard output
• Anticondensation heaters
• Labyrinth seal
• Non-standard Construction
12
12.70
12.01
11.00
12.82 12.70
6.00 3.80
8.20
3.82
8.10 3.00
3.83
12.01
11.62
11.01
20.00 10.50
6.00
6.67 3.00
4.00
5.00
6.67
10.00 10.15
5.10
4.00
5.00
4.80
3.00 Rolling contact bearing assembly 5.10 Flange endshield 10.50 Lifting eyebolt
5.67
(fixed bearing) 5.67 Plug 11.00External fan
3.80 Grease nipple 6.00 Endshield, non-drive end 11.01 External fan with key
3.82 Grease pipe 6.67 Plug 11.62 Circlip
5.67 5.67 3.83 Bush 8.10 Shaft 12.01 Fan Cowl
4.00 Rolling contact bearing assembly 8.20 Cage rotor 12.82 Plug
(floating bearing) 10.00 Stator housing with integral 20.00 Terminal box
4.80 Grease nipple feet and wound core packet 12.70 Canopy
5.00 Endshield drive end
13
10.15 Earthing clamp
Your Partners
Sales Offices: • Chandigarh - 134113 • Lucknow - 226001
House No.352, Sector 15 47, HIG ,1st Floor, Avas Vikas Colony
• Ahmedabad - 380009 Panchkula, Haryana Mail Avenue , U.P.
1st Floor, Shanti Chamber & Fax +91 0172-2585902 +91 0522-2217421
Terapanth Marg, Opp. Dinesh Hall Mobile : 94171 21990 Mobile: 9415012500
Near I.T. Cross Road, Navrangpura E-mail: siemenschd@satyam.net.in E-mail: siemens_lko@satyam.net.in
+91 79 27546803, 27546172
Fax +91 79 27546711 • Cochin - 682016 • Ludhiana - 141001
Preethi Building, 1st Floor Flat No.5 (GF), HIG Flats
• Bangalore - 560 001 M.G.Road, Ernakulam Opp. Milk Plant
No.49, Jyoti Mahal, First Floor +91 0484-2380201, 2380506 Bhai Randhir Singh Nagar
St. Marks Road Fax +91 0484-2371564 Ferozpur Road Punjab
+91 80 22042000 E-mail: kumchn@satyammail.com +91 0161-2457199
Fax +91 80 22224131 / 51120735 Mobile: 9417045273
• Durgapur - 713 216
• Chennai - 600034 A-39, Moulana Azad Sarani E-mail: siemens_ldh@satyam.net.in
4, Mahatma Gandhi Road 1st Floor, City Centre • Madurai - 625003
+91 44 2833 4000 +91 0343-2546777 26, 1st Floor, Kumarar Street
Fax +91 44 28334088 Mobile: 9832172046 Alagappa Nagar
• Coimbatore - 641018 E-mail: dgp_sldgp@sancharnet.in Mobile: 9443369375
7th Floor, East Wing, Global Towers • Guwahati - 781003 E-mail: k.shankar@siemens.com
1057, Avinashi Road G1, Hill View Apartment • Nagpur - 440 015
+91 422 5336100 Navagraha Path, Chenikuthi Hill Side Sai Sadan, Plot No.1
Fax +91 422 5336106 +91 0361-2663988 Near Mount Carmel School
• Kolkata - 700042 Mobile: 98640 37562 Ajani Square
43 Shanti Palli, R B Connector E-mail: konard@vsnl.net Mobile: 9850300524
Eastern Metropolitan Bypass • Hardwar - 249 407 E-mail: siemensnagpur@sify.com
+91 33 24449000, 24428641-47 758, 1st Floor, Model Colony • Nashik -
Fax +91 33 24449010 / 13 Awas Vikas, Jwalapur, Uttaranchal Mobile: 9822193204
• Mumbai - 400018 +91 01334 265491 E-mail: siemens_nsk@sancharnet.in
130, Pandurang Budhkar Marg, Worli Mobile: 9897070133 • Rourkela - 769 004
+91 22 24987000-02 E-mail: siemens_hwd@datainfosys.net T-15 Civil Town,
Fax +91 22 24987312 • Indore - 452001 +91 0661-2401724
• New Delhi - 110002 304, 18-19, Yash Tower Mobile: 9437041724
4A, Ring Road, I.P. Estate Maha Durga Nagar, Janki Nagar E-mail: gangulys_sl@yahoo.co.in
+91 11 23455000-09 Mobile: 9826641970 • Shaktinagar - 231 222
Fax +91 11 23455030 E-mail: siemens_indore@yahoo.com Room No. 7, Panchvati Guest House
• Pune - 411004 • Jaipur - 302016 Kota Basti, Dist. Sonebhadra, U.P.
Vasant Vihar, 1205/2/6 Shirole Road Flat No.104 +91 05446-233212, 232044
Shivajinagar Akshat Kailash Apartment Mobile: 9415233345
+91 20 25506000 Basant Marg, Bani Park, Rajasthan E-mail: siemens_upeast@sify.com
Fax +91 20 25506060 & Fax +91 0141-2204910 • Udaipur - 313001
• Hyderabad - 500 004 Mobile: 9829244313 Oasis Park, Flat No.303
5-9-19, Lakshmi Narsinh Estate E-mail: siemens_jpr@dil.in P.P.Singhal Marh, Ambavgarh
4th Floor, Secretariat Road • Jallandhar - 144 004 Mobile: 9829039120
Opp. Secretariat, Saifabad 46, 2nd Floor, Saraswati Vihar • Vapi - 396191
+91 040-2348 2500 (10 Lines) Kapurthala Road, Punjab B-603, Parasmani Apt.
Fax +91 040-2348 2534, 2348 2578 +91 0181 2259099 Opp. Post Office
Mobile: 9815921211 Besides Hanuman Temple
Territory Managers : E-mail: siemensjal@vsnl.net +91 260 2462328
• Aurangabad • Jamshedpur - 831 005 Mobile: 9825147957
Mobile: 9822193204 1511, Kirthar Apartment, E-mail: siemens_vapi@sancharnet.in
E-mail: siemens_nsk@sancharnet.in Vijaya Heritage Uliyan, Kadma • Vijayawada - 520010
• Bhilai - 490 001 +91 657 2311352 G-2, Shreya Towers
C/o. Mr. S. H. Siddiqui Mobile: 9835182772 Moghalrajapuram
Sector -1, Street- 9, Quarter No.1A E-mail: bapi_indranil@rediffmail.com / Near Jammichettu Centre
Mobile: 9826127525 Siemens_jsr@yahoo.com +91 0866-5529933
E-mail: siemens_chg@sify.com • Kanpur - 208001 Mobile: 9849001842
• Bhopal - 462 023 Flat No.19-B, 4th Floor, Prabhu Vatika E-mail: srisachandra.kartikeya@siemens.com
C/o. Mr. A.K. Sundrani, 7/109, Swarup Nagar, U. P. kartikeya_p@rediffmail.com
Sector - D, Plot No. B-204 /Fax +91 0512-2548765 • Visakhapatnam - 530004
Meenal Residency, J.K. Road Mobile: 9839102434 Flat No. 101, Shripal Towers
+91 755 2688662 E-mail: siemens_knp@satyam.net.in Kiralampudi Layout
Mobile: 9425057945 • Kolhapur - 416001 Mobile: 9849077719
E-mail: siemens@sancharnet.in Plot No.35, Vasant Smruti E-mail: siemensvizag@rediffmail.com
• Bhubaneswar - 751 003 Shivaji Park
Flat No. 4C, Aditya Palace +91 0231-2536626
218/219, Paika Nagar Mobile: 9822848415
+91 0661 2563124 E-mail: siemenskpr@sancharnet.in
Mobile : 9437013124
E-mail: angshumanrc@yahoo.com
Siemens Ltd.
Automation & Drives - Motors
Thane Belapur Road
Thane 400601
Fax: +91 22 27600076
E-mail: motors.in@siemens.com
MOT-02-120-034 Product upgradation is a continous process. Hence, data in TimePrints
This replaces MOT-02-120-027 this booklet is subject to change without prior notice. For the
latest information, please get in touch with our Sales Offices. 04200503