2 Model Preparation Model File name comforms to Standard Construction Immediate QCIC ATSB
3 Model Preparation Construction
True North is set correctly, origin of the model shall be reference to an established Immediate
geospatially QCIC
coordinated ATSB
insertion point for all disci
4 Model Preparation Scale and coordinated grid line , correct discipline is selected >> StructuralConstruction
/ ArchitecturalImmediate
/ Mechanical to QCIC ATSB
be Coordination
5 Model Preparation Remove all non-required Views / Legends/ Schedules / Lines / Shapes Construction Immediate QCIC ATSB
6 Model Preparation All families comform to BOQ naming conventions (QC via DE Tools) MTO Immediate QCIC ATSB
7 Model Preparation Overlay CNS model into ARC model, MEP model as well if available,eg: toConstruction Moderate
check for overlapping BE Wall/brickwall,clashes
between RC Suncon b
8 Model Validation Model elements contain right information e.g: Area, Level - top and base constraints,
ConstructionDescription
Immediate(QC via Schedule)
QCIC Suncon
11.3 Model Validation 2D_Check Ceiling level based (RCP) Construction Immediate BE ATSB
11.5 Model Validation 2D_Check Floor Finishes below Door Construction Immediate BE ATSB
11.6 Model Validation 2D_Check Floor Finishes at Drop level Construction Immediate BE ATSB
11.8 Model Validation 2D_Check Section - (Walls, Wall Finishes, Door placement, Ceiling) Construction Immediate BE ATSB
11.9 Model Validation 3D_Visual Check on Wall Finishes Construction Immediate BE ATSB
11.10 Model Validation 3D_Visual Check Ceiling Finishes Construction Immediate BE ATSB
11.11 Model Validation 3D_Visual Check on Floor Finishes Construction Immediate BE ATSB
11.12 Model Validation 3D_Visual Check Staircase for Railing, Skirting , Finishes Construction Immediate BE ATSB
12 Model Validation Perform Wall Profiling to avoid clashes at the upper floor (Plug-In) MTO Immediate BE Suncon
14 Model Validation Check "Warnings" and resolve it accordingly Construction Immediate BE ATSB
16 Model Validation Object Overlapping with Others (Collaborate_Interference Check) Construction Immediate BE Suncon
Page 1 of 136
Item Check Cases Category Description Phase Criticality Correction Imposed
by by
17 Model Validation Is there any DWG files loaded into the model, remove unnecessary files Construction Immediate BE ATSB
18 Model Validation Is there any RVT files loaded into the model, remove unnecessary files Construction Immediate BE ATSB
20 Model Validation Completed QC model is being saved : PRF_PX_FXX_P/LXX_ARC- MTO Minor QCIC Suncon
ARC_Nabila_QC
21 Model Validation Every trade and sub-trade shall be represented with color codes Construction Immediate BE ATSB
assigned and stated in BEP
22 Model Validation LOD of all model element shall be developed in alignment with AIA Construction Immediate BE ATSB
E202-2008 BIM Protocol Exhibit document and Guide, Instructions and
Commentary to AIA Document G202-2013, Project Building Information
23 Model Validation All model shall be developed using object-based element such as Construction Immediate BE ATSB
Modeling Protocol Form by AIA
column, staircase, ramp along with their associated parametric function
24 Model Validation Ungroup grouped items Construction Immediate QCIC ATSB
25 Parameters Object Parameter - Is the Object Code created ? MTO Immediate QCIC Suncon
26 Parameters Object Parameter - assign the object code to Revit Families (QC via MTO Immediate QCIC Suncon
DE Tools)
27 Parameters Object Parameter - Object Code assigned correctly MTO Immediate QCIC Suncon
30 Parameters Object has been tagged with membermark MTO Immediate BE Suncon
Page 2 of 136
Master
1 Survey Point
Check
Model File
name
2 comforms to
Standard
0
True North is
set correctly,
origin of the
model shall
be reference
to an
3 established
geospatially
coordinated
insertion
point for all
disciplines
0
Scale and
coordinated
grid line ,
correct
discipline is
4 selected >>
Structural /
Architectural
/ Mechanical
to be
Coordination
0
Remove all
non-required
Views /
5 Legends/
Schedules /
Lines /
Shapes
0
All families
comform to
BOQ naming
6 conventions
(QC via DE
Tools)
0
Overlay CNS
model into
ARC model,
MEP model
as well if
available,eg:
to check for
7 overlapping
between RC
Wall/brickwa
ll,clashes
between
MEP services
& ceilings.
0
Model
elements
contain right
information
e.g: Area,
8 Level - top
and base
constraints,
Description
(QC via
Schedule)
0
Model
element has
the correct
9 material
assigned (QC
via DE Tools /
Schedules)
0
Correct Revit
Category/Fa
milies
assignment
10 eg: Staircase
use Cast In
Place,
Correct wall
finishes
0
Model is
correctly
assembled
through
visual
inspection :
e.g. (1)
Doors
models at
correct
offset, (2)
Walls and
11 Wall Finishes
at correct
offset (3)
Floor at
correct
elevation
(4) Ceiling
modelled
based on
correct
materials
and height
0
2D_Check
11.1 Offset
(Elevation)
0
2D_Check
11.2 Brickwall
Thickness
0
2D_Check
11.3 Ceiling level
based (RCP)
0
2D_Check
11.4 Door Type
0
2D_Check
Floor
11.5 Finishes
below Door
0
2D_Check
Floor
11.6 Finishes at
Drop level
0
2D_Check
Section -
Staircase
( Number of
steps,
11.7 Railings,
Nosing
tiles,Skirting
height,
Finishes)
0
2D_Check
Section -
(Walls, Wall
11.8 Finishes,
Door
placement,
Ceiling)
0
3D_Visual
11.9 Check on
Wall Finishes
0
3D_Visual
Check
11.10 Ceiling
Finishes
0
3D_Visual
Check on
10.11 Floor
Finishes
0
3D_Visual
Check
Staircase for
11.12 Railing,
Skirting ,
Finishes
0
3D_Scupper
11.13 Drain
Grating
0
3D_Toilet
11.14 Accecories
0
3D_Generic
11.15 Model
0
Perform Wall
Profiling to
avoid clashes
12 at the upper
floor (Plug-
In)
0
All opening
shall be
modeled in
their
respective
element;
13 e.g., ceiling
should have
opening for
lights,
diffusers and
etc.
0
Check
"Warnings"
14 and try to
resolve it
0
Object
15 Duplication
0
Object
Overlapping
with Others
16 (Collaborate
_Interferenc
e Check)
0
Is there any
DWG files
loaded into
17 the model,
can any be
removed?
0
Is there any
RVT files
loaded into
18 the model,
can any be
removed?
0
Purge
unused
elements to
reduce file
size and it
helps MTO
process.
Repeat
process 3
times as
materials are
19 only
removed
after the
parent
object has
been
removed.Sa
ve as in
compact
mode, to
reduce file
size
0
20
Sample
REMARKS
REMARKS
REMARKS
REMARKS
Naming in REVIT & BOQ
REMARKS
REMARKS
** F01P03 model consist of F03&F04 Levels as Base / Top Level reference
REMARKS
*Wrong material used for brickwall: Masonry- Concrete Block instead of Masonr
REMARKS
*Stair should be model in place instead of model by component/sketch
REMARKS
REMARKS
REMARKS
REMARKS
REMARKS
REMARKS
REMARKS
REMARKS
REMARKS
REMARKS
REMARKS
REMARKS
REMARKS
REMARKS
REMARKS
REMARKS
REMARKS
REMARKS
REMARKS
REMARKS
REMARKS
REMARKS
REMARKS
REMARKS
REMARKS
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
Project : Parcel F
Subject : True North
Block Angle
F01 357.764° 357° 45' 50.4"
F02 357.764° 357° 45' 50.4"
F03 357.764° 357° 45' 50.4"
F04 357.764° 357° 45' 50.4"
F05 14.470° 14° 28' 12"
F06 357.764° 357° 45' 50.4"
F07 357.764° 357° 45' 50.4"
F08 19.188° 19° 11' 16.8"
F09 19.188° 19° 11' 16.8"
F10 9.340° 9° 20' 24"
F11 357.764° 357° 45' 50.4"
STEPS TO CREATE COMPARISON TEMPLATE
1 Excel - Copy and paste Value for Revit Family & Revit Type from BQ
3 Revit - Export family and type from DE Tools, select the following
parameter:
a) Revit FamilyType
b) Poundage
c) Zone
d) Membermark
e) Object Code
5 Excel (from DE) - Repeat the process for Worksheets exported from DE
tools in item 2
NA REVIT - Revit Family Type CHECK BOQ - Revit Family Type BOQ - Revit Family BOQ - Revit Type CHECK Remarks
5 Railings?
Doors
Ceiling
Railings
1 ElementID
2 Family
3 Type
4 Object Code
5 Membermark
6 Volume
7 Length
8 Perimeter
ARCHITECTURAL ELEMENTS