Energy Transition Conference, Trondheim, 26th of March 2019

Hydrogen firing in flexible industrial gas turbines


Professor Jenny Larfeldt

Restricted© Siemens Industrial Turbomachinery AB 2019 www.sit-ab.se/


Siemens turbine portfolio
The right turbine for every requirement
Steam Turbines Gas Turbines
SST-9000 1,900 MW
SST-6000 1,200 MW
SST-5000 650 MW
SST-4000 380 MW
SST-3000 250 MW
SST-800 250 MW
SST-700/900 250 MW
SST-600 200 MW
SST-500 100 MW
SST-400 60 MW
SST-300 45 MW
SST-200 10 MW
SST-150 20 MW Granada Spain
D-R R 25 MW Andasol 1+2
D-R B 12 MW Mirror fiels 2x510 000m2
D-R RS 10 MW 2xSST-700
D-R K 5 MW
D-R GAF 4 MW Replacement of
D-R AVTTW, 2TA&GTW 5 MW KK&K portfolio
D-R C 3 MW
D-R SST-350/500/700 3 MW
D-R RLA / H / V 2 MW
Utility Industrial DRESSER-RAND Heavy-duty Industrial Aeroderivative
steam turbines steam turbines steam turbines gas turbines gas turbines gas turbines
Unrestricted © Siemens AG 2018
Page 2 Siemens Gas & Power
Industrial gas turbine
SGT-800 / 57MW core engine
• 30 DLE burners of so called 3rd generation in an annular combustor
• Air entering combustor with about 20 bar and 430°C
• Fleet Reliability:
99.6%
• Fleet Availability:
97.7%

Unrestricted © Siemens AG 2018


Page 3 Siemens Gas & Power
Developing towards 100% H2

Engine test of SGT-700 Full string tests :


in 2012 and 2014 SGT-800 50% H2 SGT-600 80% H2
2008 2012 2014 2016 2017 2018 2019

Atmospheric and SGT-700 continuous 100% H2 concept


high pressure tests operation since Sept. burner tested
in 2008, 2009 and 2014 (10%H2)
2012 Siemens high pressure
combustion test center in
Finspång additive Berlin
Experience manufacturing
of ~90% H2 in workshop opens
diffusion type -> R&D speed!
combustors since Rapid manufacturing
1980

Unrestricted © Siemens AG 2018


Page 4 Siemens Gas & Power
A customer case: Martano 420 MW CCPP
- SGT-800 in 6x1
CCPP Efficiency Characteristics

• Highest CCPP full load efficiency at full


load.

• Excellent CCPP part load efficiency - up


to +5%-units higher than alternative GTs

• Grid Stability

Example:
Loss of 1 SGT-800 in 6x1 configuration implies
loss of ~73 MW (~16%)
Loss of 1 GT in 2x1 config. implies loss of ~210
MW (50%)
• Broadest CCPP operating range (Turn-
down ratio)

• Service outages

Unrestricted © Siemens AG 2018


Page 5 Siemens Gas & Power
Thank you

Siemens 145 MW Power Island Barge Professor Jenny Larfeldt


2xSGT 800 and 1xSST 600 , 2xHRSG Senior Combustor Expert
BESS (Battery) Phone: +46 122 82 789
Mobile: +46 70 180 14 147
E-mail:
jenny.larfeldt@siemens.com

Unrestricted © Siemens AG 2018


Page 6 Siemens Gas & Power