Vous êtes sur la page 1sur 1

Overview - Calculation summary 18:25:13 01/08/2019

The sizing is complete - please note the hints

Overview - Pressure relief valve


Identifier VS-V2
File name
Sizing according to fire case No

Process data
Phase Single phase
Medium Methane (Gaseous)
Temperature of fluid t1 0,0 °C
Set pressure pSet 16,0 bar(g)
Relieving pressure p0 17,6 bar(g)
Back pressure pb 0,43483 bar(g)
Mass flow rate qm 0,05726 kg/h
Volume flow rate (standard conditions) qn 0,08 m³/h

Pressure relief valve


Calculation standard ISO 4126:2013/Amd.1:2016
Valve manufacturer HEROSE GMBH (06001)
Rated coefficient of discharge (gas/vapor) Kdr,G 0,09 -
Narrowest flow cross-section A0 28,3 mm²

Results
Required discharge coefficient for A0 Kdr,min 165,569 E-6 -
Required flow cross-section for Kdr A0,min 0,052062 mm²
Capacity exceed R 54 258,0 %
Rated mass flow qm,t 31,125 kg/h
Reaction force 4,3423 N
Sound pressure level (1m) LpA 67,7 dB(A)

Feeding pipe
Permissible pressure loss Δpmax,F 0,48 bar
Pressure loss of pipeline Δp,F 0,010783 bar
Permissible pipe length lmax,F 44,513 m
Length of pipeline l,F 1,0 m

Discharge pipe
Max. permissible pressure loss ΔpP 3,0 %
Permissible pressure loss Δpmax,O 0,48 bar
Built-up back pressure pae 0,43483 bar
Permissible pipe length lmax,O 1,1359 m
Length of pipeline l,1 1,0 m

© 2019 by HEROSE GmbH