CONFIGURATION

Line Extender LE300 or LE200


POINT TO POINT

1. SCHEMATIC DIAGRAM
LE A: MASTER

LE B: SLAVE

T1/E1 data: cat5 or cat 6 cable or via T1/E1 Media convertor

Note:

Line Extenders must be connected in a “cross-over” on E1 interface port

2. SETTING PROCEDURE.

2.1 DIP Switch on Line Extender


2.1.1 MASTER UNIT SETTING
SW4
Switch Setting
1 Close
2 Close
3 Close
4 Close
5 Close
6 Close
7 Close
8 Close

SW6
Switch Setting
1 Open
2 Open
3 Close
4 Open
SW3
Switch Setting
1 Open
2 Open
3 Open
4 Open
5 Open
6 Open
7 Open
8 Open

SW5
Switch Setting
1 Close
2 Open
3 Open
4 Open
5 Open
6 Open
7 Open
8 Open

SW1
Switch Setting
0 On

SW2
Switch Setting
1 Up
2 Up
3 Up
4 Up
5 Up
6 Up
7 Up
8 Up
Jumper setting
Switch Setting
P6 Terminal 1 2
P7 Terminal 1 2
P8 Terminal 1 2
P9 Terminal 1 2
P10 Terminal 1 2
P11 Terminal 1 2
P12 Terminal 2 3
P13 Terminal 2 3
P20 Terminal 1 2
P21 Terminal 1 2
2.1.2 SLAVE UNIT SETTING

SW4
Switch Setting
1 Close
2 Close
3 Close
4 Close
5 Close
6 Close
7 Close
8 Close
SW6
Switch Setting
1 Open
2 Open
3 Close
4 Open

SW3
Switch Setting
1 Close
2 Close
3 Open
4 Open
5 Open
6 Open
7 Open
8 Open

SW5
Switch Setting
1 Close
2 Open
3 Open
4 Open
5 Open
6 Open
7 Open
8 Open
SW1
Switch Setting
0 On

SW2
Switch Setting
1 Up
2 Up
3 Up
4 Up
5 Up
6 Up
7 Up
8 Up

Jumper setting
Switch Setting
P6 Terminal 1 2
P7 Terminal 1 2
P8 Terminal 1 2
P9 Terminal 1 2
P10 Terminal 1 2
P11 Terminal 1 2
P12 Terminal 2 3
P13 Terminal 2 3
P20 Terminal 1 2
P21 Terminal 1 2
2.2 MEDIA CONVERTOR

2.2.1 MASTER MEDIA CONVERTOR

SW2
Switch Setting
1 Close
2 Close
3 On
4 On
5 On
6 On
7 On
8 Close
9 On
10 On

SW3
Switch Setting
1 Close (Down)
2 Close (Down)
3 On
4 On
5 On
6 On
7 Close
8 Close

2.2.2 SLAVE MEDIA CONVERTOR

SW2
Switch Setting
1 Close
2 Close
3 On
4 On
5 On
6 On
7 On
8 Close
9 On
10 On

SW3
Switch Setting
1 Close (Down)
2 On
3 On
4 On
5 On
6 On
7 Close
8 Close

2.2.3 STATUS LINK BETWEEN MASTER & SLAVER

If these units cannot link together, the master and & slave will status LOS error under LED red color

If the link success, the master & remote will status RM under LED Green color
3. Generating Audio Test Signal

3.1 Connect Handset station to one of page party line (1~5)

3.2 SET DIP SW 1 & 2

SW1
Switch Setting
1 On
SW2
Switch Setting
1 On
2 On
3 On
4 On
5 On
6 On
7 On
8 Down

3.3 CHECKING AUDIO LINE AFTER SETTING SWITCH.

This step only perform testing on local without signal sync to remote site and vice versa. Exp: Test on
Master unit that handset station connected master unit can hear audio and the other handset of remote
will not hear theses audio tone and vice versa
The audio on handset will receive the test waveform with 7 kHz (sine wave). Note that the frequency
selections are different on the selected audio party line. Refer to tables below for valid switch settings.
The page and another party line will be setting similar above steps
3.1 RESTORE LINE EXTENDER IN NORMAL OPERATION.

SW1
Switch Setting
0

SW2
Switch Setting
1 On
2 On
3 On
4 On
5 On
6 On
7 On
8 On