building data

Gross Floor Area: 2,828.20 sqm


Building height: 18.30m
Total Floors (including roofdeck): 7
Total # of Units: 96 (384 beds)
Parking: 8 slots
Building Efficiency: 71%

Construction Time: 18 months

Conventional COncrete construction


with steel deck flooring.

Construction Floor Area: 3,292.90 sqm


far: 4.79 (5.0 allowed)
Total Power: 114kva
Total Water: 26,272.0 l/day
Elevator: 1 (machine room-less)

fire suppression system


Fire Alarm System

PERSPECTIVE of Atrium
NOT TO SCALE

schematic design
PROJECT: SHEET CONTENTS DATE: SHEET NO:
ULYSSES NOLAN C. PAREDES PROPOSED 6-STOREY DORMITORY
PRC# 22239 PTR# 2582070 DRAWN:
17617 115801 040314 VALIDITY: 06 JUNE 2017 Mr. & Mrs. Tuason
Issued: 03.04.2014 QC PLACE: SANTA ROSA CITY
VITO CRUZ EXTENSION, BRGY. SAN ANTONIO, MAKATI CITY CHECKED:
A-01
TIN# 319535872-0000
RA9266 ART IV SECTION 33. Ownership of Plans, Specifications and other Contract Documents. - Drawings and specifications and other contract documents duly signed, stamped or sealed, as instruments of service, are the intellectual
property and documents of thr architect, whether the object for which they are made is executed or not. It shall be unlawful for any person to duplicate or to make copies of said documents for use in the repetition of and for other
projects or buildings, whether executed partly or in whole, without the written consent of architect or author of said documents.
schematic design
PROJECT: SHEET CONTENTS DATE: SHEET NO:
ULYSSES NOLAN C. PAREDES PROPOSED 6-STOREY DORMITORY
PRC# 22239 PTR# 2582070 DRAWN:
17617 115801 040314 VALIDITY: 06 JUNE 2017 Mr. & Mrs. Tuason
Issued: 03.04.2014 QC PLACE: SANTA ROSA CITY
VITO CRUZ EXTENSION, BRGY. SAN ANTONIO, MAKATI CITY CHECKED:
A-02
TIN# 319535872-0000
RA9266 ART IV SECTION 33. Ownership of Plans, Specifications and other Contract Documents. - Drawings and specifications and other contract documents duly signed, stamped or sealed, as instruments of service, are the intellectual
property and documents of thr architect, whether the object for which they are made is executed or not. It shall be unlawful for any person to duplicate or to make copies of said documents for use in the repetition of and for other
projects or buildings, whether executed partly or in whole, without the written consent of architect or author of said documents.
30.00
5.00 25.00

0.80
lightwell

glass wall
lightwell

PARKING
open above

6.95
RETAIL UNIT
159.50 SQM

8.75

7.80
vito cruz extension

24.85

FIRE

1.95
UP UP
16670

elev ESCAPE

16.67
2.80
main

4.15
admin/
1.00

stairs
walkway reception toi.
sitting

2.00
area
glass
wall
8.40

3.00
line of
3.77

floor above planter


8.55 UTILITY
DRIVEWAY
6.77

6.92
GENSET/

3.47
ee room
PARKING

25.45 4.55
30.00

a GROUND FLOOR PLAN


A-03 1/100

schematic design
floor data: PROJECT: SHEET CONTENTS DATE: SHEET NO:
ULYSSES NOLAN C. PAREDES gfa: 260.23 sqm
PROPOSED 6-STOREY DORMITORY
PRC# 22239 PTR# 2582070 rent: 159.50 sqm DRAWN:
17617 115801 040314 VALIDITY: 06 JUNE 2017 parking: 8 slots Mr. & Mrs. Tuason
Issued: 03.04.2014 QC PLACE: SANTA ROSA CITY floor eff: 61%
VITO CRUZ EXTENSION, BRGY. SAN ANTONIO, MAKATI CITY CHECKED:
A-03
TIN# 319535872-0000
RA9266 ART IV SECTION 33. Ownership of Plans, Specifications and other Contract Documents. - Drawings and specifications and other contract documents duly signed, stamped or sealed, as instruments of service, are the intellectual
property and documents of thr architect, whether the object for which they are made is executed or not. It shall be unlawful for any person to duplicate or to make copies of said documents for use in the repetition of and for other
projects or buildings, whether executed partly or in whole, without the written consent of architect or author of said documents.
30.00

toi.

4-bed unit
15.72 sqm
4-bed unit 4-bed unit 4-bed unit 4-bed unit 4-bed unit 4-bed unit 4-bed unit
15.72 sqm 15.72 sqm 15.72 sqm 15.72 sqm 15.72 sqm 15.72 sqm 15.72 sqm

4-bed unit
15.72 sqm
5.75 4.40 2.55 5.30 4.20
corridor

up 1.41 up
16670

FIRE

2.70
2.70
atrium elev atrium
4-bed unit stairs ESCAPE
open above open above
15.72 sqm
dn dn

1.97

1.18
3.00 1.47

1.48
corridor
1.15
4-bed unit
15.72 sqm

4-bed unit 4-bed unit 4-bed unit 4-bed unit 4-bed unit 4-bed unit 4-bed unit
15.72 sqm 15.72 sqm 15.72 sqm 15.72 sqm 15.72 sqm 15.72 sqm 15.72 sqm
4-bed unit
15.72 sqm

30.00

a 2nd FLOOR PLAN


A-04 1/100

schematic design
floor data: PROJECT: SHEET CONTENTS DATE: SHEET NO:
ULYSSES NOLAN C. PAREDES gfa: 444.14 sqm
PROPOSED 6-STOREY DORMITORY
PRC# 22239 PTR# 2582070 rent: 269.48 sqm DRAWN:
17617 115801 040314 VALIDITY: 06 JUNE 2017 Units: 16 Mr. & Mrs. Tuason
Issued: 03.04.2014 QC PLACE: SANTA ROSA CITY floor eff: 61%
VITO CRUZ EXTENSION, BRGY. SAN ANTONIO, MAKATI CITY CHECKED:
A-04
TIN# 319535872-0000
RA9266 ART IV SECTION 33. Ownership of Plans, Specifications and other Contract Documents. - Drawings and specifications and other contract documents duly signed, stamped or sealed, as instruments of service, are the intellectual
property and documents of thr architect, whether the object for which they are made is executed or not. It shall be unlawful for any person to duplicate or to make copies of said documents for use in the repetition of and for other
projects or buildings, whether executed partly or in whole, without the written consent of architect or author of said documents.
30.00

4-bed unit
15.72 sqm
4-bed unit 4-bed unit 4-bed unit 4-bed unit 4-bed unit 4-bed unit 4-bed unit
15.72 sqm 15.72 sqm 15.72 sqm 15.72 sqm 15.72 sqm 15.72 sqm 15.72 sqm

4-bed unit
15.72 sqm
5.75 4.40 2.55 5.30 4.20
corridor

up 1.41 up
16670

FIRE

3.10

3.10
4-bed unit elev
open below stairs open below ESCAPE
15.72 sqm
dn dn

1.97

1.18
3.00 1.47

1.48
corridor
1.15
4-bed unit
15.72 sqm

4-bed unit 4-bed unit 4-bed unit 4-bed unit 4-bed unit 4-bed unit 4-bed unit
15.72 sqm 15.72 sqm 15.72 sqm 15.72 sqm 15.72 sqm 15.72 sqm 15.72 sqm
4-bed unit
15.72 sqm

30.00

a Typical 3rd-6th FLOOR PLAN


A-05 1/100

schematic design
floor data: PROJECT: SHEET CONTENTS DATE: SHEET NO:
ULYSSES NOLAN C. PAREDES gfa: 423.22 sqm
PROPOSED 6-STOREY DORMITORY
PRC# 22239 PTR# 2582070 rent: 322.84 sqm DRAWN:
17617 115801 040314 VALIDITY: 06 JUNE 2017 Units: 19 Mr. & Mrs. Tuason
Issued: 03.04.2014 QC PLACE: SANTA ROSA CITY floor eff: 71%
VITO CRUZ EXTENSION, BRGY. SAN ANTONIO, MAKATI CITY CHECKED:
A-05
TIN# 319535872-0000
RA9266 ART IV SECTION 33. Ownership of Plans, Specifications and other Contract Documents. - Drawings and specifications and other contract documents duly signed, stamped or sealed, as instruments of service, are the intellectual
property and documents of thr architect, whether the object for which they are made is executed or not. It shall be unlawful for any person to duplicate or to make copies of said documents for use in the repetition of and for other
projects or buildings, whether executed partly or in whole, without the written consent of architect or author of said documents.
27.90

6.95
utility deck
108.81 sqm

FIRE
16.67

3.10

2.71
ESCAPE
dn

roof deck
290.38 sqm

7.01
5.70 1.15 22.20
a roof deck PLAN
A-06 1/100

schematic design
floor data: PROJECT: SHEET CONTENTS DATE: SHEET NO:
ULYSSES NOLAN C. PAREDES gfa: 430.95 sqm
PROPOSED 6-STOREY DORMITORY
PRC# 22239 PTR# 2582070 Common: 292.32 sqm DRAWN:
17617 115801 040314 VALIDITY: 06 JUNE 2017 Mr. & Mrs. Tuason
Issued: 03.04.2014 QC PLACE: SANTA ROSA CITY
VITO CRUZ EXTENSION, BRGY. SAN ANTONIO, MAKATI CITY CHECKED:
A-06
TIN# 319535872-0000
RA9266 ART IV SECTION 33. Ownership of Plans, Specifications and other Contract Documents. - Drawings and specifications and other contract documents duly signed, stamped or sealed, as instruments of service, are the intellectual
property and documents of thr architect, whether the object for which they are made is executed or not. It shall be unlawful for any person to duplicate or to make copies of said documents for use in the repetition of and for other
projects or buildings, whether executed partly or in whole, without the written consent of architect or author of said documents.
1.20

2.47
roof deck
roof deck ffl
+18.30m ngl
3.00

6th floor ffl


+15.30m ngl
3.00

5th floor ffl


+12.30m ngl
3.00

atrium atrium
18.30

4th floor ffl shaft


stairwell
+9.30m ngl
3.00

3rd floor ffl


+6.30m ngl
3.00

common area

2nd floor ffl


+3.30m ngl
3.15

admin/
retail space
reception
grd floor ffl
0.15m ngl

1 SECTION a
A-07 1/100

schematic design
PROJECT: SHEET CONTENTS DATE: SHEET NO:
ULYSSES NOLAN C. PAREDES PROPOSED 6-STOREY DORMITORY
PRC# 22239 PTR# 2582070 DRAWN:
17617 115801 040314 VALIDITY: 06 JUNE 2017 Mr. & Mrs. Tuason
Issued: 03.04.2014 QC PLACE: SANTA ROSA CITY
VITO CRUZ EXTENSION, BRGY. SAN ANTONIO, MAKATI CITY CHECKED:
A-07
TIN# 319535872-0000
RA9266 ART IV SECTION 33. Ownership of Plans, Specifications and other Contract Documents. - Drawings and specifications and other contract documents duly signed, stamped or sealed, as instruments of service, are the intellectual
property and documents of thr architect, whether the object for which they are made is executed or not. It shall be unlawful for any person to duplicate or to make copies of said documents for use in the repetition of and for other
projects or buildings, whether executed partly or in whole, without the written consent of architect or author of said documents.
3.00
3.00
bulkheas 0.95
0.90 1.20 0.90 ac
0.40 1.15 1.05 2.30

0.70
ac
ac
chase

recessed light
1.20 fixture light fix.
light fix.
1.95

bed
bed bed toilet
corridor

2.70
pocket

2.45
door

1.90
ladder
desk

1.55
chase

2.00

2.10
wc

0.75
clo clo
clo clo
1.05

bed

1.19
1
5.30

- 3 balcony
-
clo - clo railing

0.40
1 section
wc 4.90 1.33

1.50
A-08 1/150
3
2.30

section

2.20
desk 1/150
sink A-08

sho

light
light fix.
0.70

fix.
1.35 0.95
1.47

3.00 main pb

ac ledge
3.00
bulkheas jalousie windows
bed
ac w/ flyscreen
1.10

light fix. closet


switch/
ladder outlet
desk

bed
1.20
bed
2.70

2.45
0.50

1.10

headboard
0.03

bed bed
a Typical unit
A-08 1/150

schematic design
floor data: PROJECT: SHEET CONTENTS DATE: SHEET NO:
ULYSSES NOLAN C. PAREDES gfa: 423.22 sqm
PROPOSED 6-STOREY DORMITORY
PRC# 22239 PTR# 2582070 rent: 322.84 sqm DRAWN:
17617 115801 040314 VALIDITY: 06 JUNE 2017 Units: 19 Mr. & Mrs. Tuason
Issued: 03.04.2014 QC PLACE: SANTA ROSA CITY floor eff: 71%
VITO CRUZ EXTENSION, BRGY. SAN ANTONIO, MAKATI CITY CHECKED:
A-08
TIN# 319535872-0000
RA9266 ART IV SECTION 33. Ownership of Plans, Specifications and other Contract Documents. - Drawings and specifications and other contract documents duly signed, stamped or sealed, as instruments of service, are the intellectual
property and documents of thr architect, whether the object for which they are made is executed or not. It shall be unlawful for any person to duplicate or to make copies of said documents for use in the repetition of and for other
projects or buildings, whether executed partly or in whole, without the written consent of architect or author of said documents.
1 cutaway section
A-09 not to scale

schematic design
PROJECT: SHEET CONTENTS DATE: SHEET NO:
ULYSSES NOLAN C. PAREDES PROPOSED 6-STOREY DORMITORY
PRC# 22239 PTR# 2582070 DRAWN:
17617 115801 040314 VALIDITY: 06 JUNE 2017 Mr. & Mrs. Tuason
Issued: 03.04.2014 QC PLACE: SANTA ROSA CITY
VITO CRUZ EXTENSION, BRGY. SAN ANTONIO, MAKATI CITY CHECKED:
A-09
TIN# 319535872-0000
RA9266 ART IV SECTION 33. Ownership of Plans, Specifications and other Contract Documents. - Drawings and specifications and other contract documents duly signed, stamped or sealed, as instruments of service, are the intellectual
property and documents of thr architect, whether the object for which they are made is executed or not. It shall be unlawful for any person to duplicate or to make copies of said documents for use in the repetition of and for other
projects or buildings, whether executed partly or in whole, without the written consent of architect or author of said documents.

Vous aimerez peut-être aussi