Académique Documents
Professionnel Documents
Culture Documents
Input
Bridge Span, L 237.40 m
SSTB Standard Design (Y/N) N
Provide windguy arrangement (Y/N) Y
Selected data Tentative data
Backstay distances Bridge Span 237.40 237.40
Left Bank, DL 50.30 m Tower Height 27.73 27.73
Right Bank, DR 40.80 m Dead Load sag 21.90 21.93 m
Dead Load Camber 4.78 4.75 m
Main Cables 6 nos 40 mm 6 nos Dia. 40
Spanning Cables 2 nos 40 mm 2 nos Dia. 40
Result
Safety Factor of main cables, SF 3.18
Sag f Displacement of Sddles (cm)
Load, Tension
Load case Camber C
kN/m kN ∆DL ∆DR
Main m
Cable Hoisting 0.356 125.82 21.19 -0.06 -0.04
Dead 1.684 577.53 21.90 0.00 0.00
Full 5.384 1725.44 23.67 / /
Hoisting 0.119 175.66 -4.78
Spanning Backstay angle of main
Dead 0.153 226.40 4.78 21.74
Cable cable at full load, degree
Full 0.000 3.01
Live 3.853 Elasticity of Cable = 110 kN/mm2
Main Cable Single 345.96 m Overlap in 2.55 m 8 nos
Length Bulldog Grips in
Spanning Cable 242.76 m each 2.55 m 8 nos
including each cable end
Handrail/Fixation overlap 238.76 m terminal 0.55 m 3 nos
CALCULATION OF FORCES ON TOWERS AND CHECKING OF TOWER CAPACITY
Case Result
A Safe
B Safe
DESIGN OF SUSPENDERS
RESULT
Total suspenders = 390 nos 1st Suspender from Tower = 2.30 m
Weight of suspenders = 3850.29 kg Steel parts to be galvanized = 5215.29 kg
Total Nuts & Bolts = 117.00 kg Total Surface area of Suspender = 158.49 m2
Total structural steel = 5215.29 kg Total transportation weight = 5534.27 kg
ln (mm) jn lrc (mm) Diameter of
c/c (mm) cable lr (mm)
Susp. No. suspender standard cutting length of suspender
to cable extra piece
length piece extra piece mm
0 1300 758 0 758 998 16
1 1303 761 0 761 1001 16
2 1311 769 0 769 1009 16
3 1325 783 0 783 1023 16
4 1344 802 0 802 1042 16
5 1368 826 0 826 1066 16
6 1398 856 0 856 1096 16
7 1434 892 0 892 1132 16
8 1475 933 0 933 1173 16
9 1521 979 0 979 1219 16
10 1573 1031 0 1031 1271 16
11 1630 1088 0 1088 1328 16
12 1693 1151 0 1151 1391 16
13 1761 1219 0 1219 1459 16
14 1834 1292 0 1292 1532 16
15 1914 1372 0 1372 1612 16
16 1998 1456 0 1456 1696 16
17 2088 1546 0 1546 1786 16
18 2183 1641 0 1641 1881 16
19 2284 1742 0 1742 1982 16
20 2391 1849 0 1849 2089 16
21 2503 1961 0 1961 2201 16
22 2620 2078 1 428 668 16
23 2742 2200 1 550 790 16
24 2871 2329 1 679 919 16
25 3004 2462 1 812 1052 16
26 3143 2601 1 951 1191 16
27 3288 2746 1 1096 1336 16
28 3438 2896 1 1246 1486 16
29 3593 3051 1 1401 1641 16
30 3754 3212 1 1562 1802 16
End
Long S p a n T r a i l B r i d g e S t a n d a r d
Page 3
ln (mm) jn lrc (mm) Diameter of
c/c (mm) cable lr (mm)
Susp. No. suspender standard cutting length of suspender
to cable extra piece
length piece extra piece mm
71 15046 14504 8 1304 1484 12
72 15436 14894 8 1694 1874 12
73 15831 15289 9 439 619 12
74 16232 15690 9 840 1020 12
75 16638 16096 9 1246 1426 12
76 17050 16508 9 1658 1838 12
77 17467 16925 10 425 605 12
78 17890 17348 10 848 1028 12
79 18318 17776 10 1276 1456 12
80 18751 18209 10 1709 1889 12
81 19190 18648 11 498 678 12
82 19635 19093 11 943 1123 12
83 20085 19543 11 1393 1573 12
84 20540 19998 11 1848 2028 12
85 21001 20459 12 659 839 12
86 21467 20925 12 1125 1305 12
87 21939 21397 12 1597 1777 12
88 22416 21874 13 424 604 12
89 22899 22357 13 907 1087 12
90 23387 22845 13 1395 1575 12
91 23880 23338 13 1888 2068 12
92 24379 23837 14 737 917 12
93 24884 24342 14 1242 1422 12
94 25394 24852 14 1752 1932 12
95 25909 25367 15 617 797 12
96 26430 25888 15 1138 1318 12
97 26956 26414 15 1664 1844 12
ψ ψ
ε ε
ψ ψ
ε ε
Input
Main Cable Characteristics
No./ Size 6 nos 40 mm Tension, TMf 1725.4 kN
C/C1 distance 4.00 m Inclination, βf 21.74 deg
Soil Parameters
Frictional angle of sub-soil, φ1 28 Unit weight of sub-soil, γ1 18 kN/m3
Friction angle of backfilling, φ2 27 Unit weight of backfilling, γ2 17 kN/m3
Ground bearing pressure, σperm 250 kN/m2 Ground water at depth, h 0
Foundation dimension
Size min max selected Size min max selected
Back height,
Width, B 5.4 6 5.60 m H1 3.5 6 4.70 m
Front height,
Length, L 7.1 9.1 8.90 m H2 1.6 5 2.50 m
Additional
b 1 1.00 m Load, A 0.00 kN Arm, a 0.00 m
Topographic data
Earth pressure height
ha 4.50 m Front slope, ε 5.00 deg
ha1 0.00 m Linfl 15.15 m Back slope, ψ 5.00 deg
hp 2.30 m Embedded depth, t 2.30 m
Result
Input
Main Cable Characteristics
No./ Size 6 nos 40 mm Tension, TMf 1725.4 kN
C/C1 distance 4.00 m Inclination, βf 21.74 deg
Soil Parameters
Frictional angle of sub-soil, φ1 28 Unit weight of sub-soil, γ1 18 kN/m3
Friction angle of backfilling, φ2 27 Unit weight of backfilling, γ2 17 kN/m3
Ground bearing pressure, σperm 250 kN/m2 Ground water at depth, h 0
Foundation dimension
Size min max selected Size min max selected
Back height,
Width, B 5.4 6 5.60 m H1 3.5 6 4.70 m
Front height,
Length, L 7.1 9.1 8.90 m H2 1.6 5 2.50 m
Additional
b 1 1.00 m Load, A 0.00 kN Arm, a 0.00 m
Topographic data
Earth pressure height
ha 4.70 m Front slope, ε 5.00 deg
ha1 0.50 m Linfl 15.19 m Back slope, ψ 10.00 deg
hp 2.30 m Embedded depth, t 2.30 m
Result
Selection of bank from where to initiate (Press L for Left Bank & R for Right Bank) L
A) Fixing of 1st wind-tie position on both banks
INPUT
LB Windguy anchor level, HL = 611.00 m RB Windguy anchor level, HR = 611.00 m
C) Calculating anchor position on right bank in respect to pre-fixed anchor position on left bank
INPUT RESULT
Distance CL = 21.00 m Distance CR = 22.98 m
Distance DL = -17.00 m Span/Sag ratio, L/b = 9.59
Distance DR = -11.35 m Horz. Angle α αL = 19.29 deg
*Distance VL = 120.00 m 118.70 m Horz. Angle α αR = 19.29 deg
*Input tentative value of V in left cell Level difference at mid span ∆hlp = 0.42 m
Check !
1) if ∆ hlp < 0, then repeat procedure B, by reducing the H R and or H L .
Bridge Name: Paundi Khola Bridge No.: 1
Design by: Date:
INPUT
Bridge span = 237.40 m Camber = 4.78 m T/ Bottom Level = 612.50 m
CL distance = 21.00 m Distance DL = -17.00 m Distance BL = 22.70 m
CR distance = 22.98 m Distance DR = -11.35 m Distance BR = 22.70 m
VL distance = 118.70 m LB WA Level = 611.00 m RB WA Level = 611.00 m
RESULT
Sag b = 24.75 m L/b ratio 9.59 ∆hlp = 0.42 m
EL distance = 6.08 m Hz/Angle αL = 19.29 deg Ver/Angle βL= 6.30 deg
ER distance = 12.09 m Hz/Angle αR = 19.29 deg Ver/Angle βR= 5.97 deg
TL = 138.47 kN TR = 138.47 kN Safety factor = 4.22
Windguy cable size Φ = 32 mm Wind-ties cable size Φ = 13 mm
Cutting length of W/Cable = 218.00 m Total cutting length of windties = 330.00 m
Calculation for up stream windguy arrangement
Windties are given from left bank to right bank
C/C wind-ties Cutting length of Inclined dist., Dw Horz. c/c dist.
No.
[m] wind-ties [m] [m] [m]
1 18.41 19.01 18.27
2 16.76 17.36 5.10 16.63
3 15.20 15.80 5.07 15.08
4 13.72 14.32 5.04 13.61
5 12.33 12.93 5.01 12.22
6 11.02 11.62 4.99 10.92
7 9.79 10.39 4.97 9.70
8 8.65 9.25 4.94 8.56
9 7.59 8.19 4.92 7.51
10 6.62 7.22 4.90 6.55
11 5.73 6.33 4.89 5.67
12 4.93 5.53 4.87 4.87
13 4.22 4.82 4.86 4.15
14 3.58 4.18 4.84 3.52
15 3.03 3.63 4.83 2.98
16 2.57 3.17 4.82 2.52
17 2.19 2.79 4.82 2.14
18 1.90 2.50 4.81 1.84
19 1.69 2.29 4.81 1.63
20 1.56 2.16 4.80 1.51
21 1.52 2.12 4.80 1.47
22 1.56 2.16 4.80 1.51
23 1.69 2.29 4.80 1.63
24 1.90 2.50 4.80 1.84
25 2.19 2.79 4.81 2.14
26 2.56 3.16 4.82 2.52
27 3.03 3.63 4.82 2.98
28 3.57 4.17 4.83 3.52
29 4.20 4.80 4.84 4.15
30 4.92 5.52 4.86 4.87
31 5.72 6.32 4.87 5.67
32 6.60 7.20 4.89 6.55
See next page
Calculation for up stream windguy arrangement
Windties are given from left bank to right bank
C/C wind-ties Cutting length of Inclined dist., Dw Horz. c/c dist.
No.
[m] wind-ties [m] [m] [m]
33 7.57 8.17 4.90 7.51
34 8.62 9.22 4.92 8.56
35 9.76 10.36 4.94 9.70
36 10.98 11.58 4.96 10.92
37 12.29 12.89 4.99 12.22
38 13.68 14.28 5.01 13.61
39 15.15 15.75 5.04 15.08
40 16.71 17.31 5.06 16.63
41 18.36 18.96 5.09 18.27
END
DESIGN OF WINDGUY ARRANGMENT
BASIC INPUT
Selection of bank from where to initiate (Press L for Left Bank & R for Right Bank) L
A) Fixing of 1st wind-tie position on both banks
INPUT
LB Windguy anchor level, HL = 611.00 m RB Windguy anchor level, HR = 611.00 m
C) Calculating anchor position on right bank in respect to pre-fixed anchor position on left bank
INPUT RESULT
Distance CL = 28.00 m Distance CR = 24.67 m
Distance DL = 4.50 m Span/Sag ratio, L/b = 9.79
Distance DR = -5.20 m Horz. Angle α αL = 18.94 deg
*Distance VL = 120.00 m 118.70 m Horz. Angle α αR = 18.94 deg
*Input tentative value of V in left cell Level difference at mid span ∆hlp = 0.35 m
Check !
1) if ∆ hlp < 0, then repeat procedure B, by reducing the H R and or H L .
Bridge Name: Paundi Khola Bridge No.: 1
Design by: Date:
INPUT
Bridge span = 237.40 m Camber = 4.78 m T/ Bottom Level = 612.50 m
CL distance = 28.00 m Distance DL = 4.50 m Distance BL = 22.70 m
CR distance = 24.67 m Distance DR = -5.20 m Distance BR = 22.70 m
VL distance = 118.70 m LB WA Level = 611.00 m RB WA Level = 611.00 m
RESULT
Sag b = 24.26 m L/b ratio 9.79 ∆hlp = 0.35 m
EL distance = 28.88 m Hz/Angle αL = 18.94 deg Ver/Angle βL= 5.27 deg
ER distance = 18.59 m Hz/Angle αR = 18.94 deg Ver/Angle βR= 5.72 deg
TL = 140.76 kN TR = 140.76 kN Safety factor = 4.16
Windguy cable size Φ = 32 mm Wind-ties cable size Φ = 13 mm
Cutting length of W/Cable = 247.00 m Total cutting length of windties = 323.00 m
Calculation for down stream windguy arrangemnet
Windties are given from left bank to right bank
C/C wind-ties Cutting length of Inclined dist., Dw Horz. c/c dist.
No.
[m] wind-ties [m] [m] [m]
1 17.95 18.55 17.93
2 16.34 16.94 5.07 16.33
3 14.82 15.42 5.05 14.80
4 13.38 13.98 5.02 13.36
5 12.02 12.62 5.00 12.00
6 10.74 11.34 4.97 10.73
7 9.55 10.15 4.95 9.53
8 8.44 9.04 4.93 8.42
9 7.41 8.01 4.91 7.39
10 6.46 7.06 4.90 6.45
11 5.60 6.20 4.88 5.58
12 4.82 5.42 4.87 4.80
13 4.12 4.72 4.85 4.10
14 3.50 4.10 4.84 3.48
15 2.97 3.57 4.83 2.95
16 2.52 3.12 4.82 2.49
17 2.15 2.75 4.81 2.12
18 1.87 2.47 4.81 1.84
19 1.67 2.27 4.80 1.63
20 1.55 2.15 4.80 1.51
21 1.51 2.11 4.80 1.47
22 1.55 2.15 4.80 1.51
23 1.67 2.27 4.80 1.63
24 1.87 2.47 4.80 1.84
25 2.16 2.76 4.81 2.12
26 2.53 3.13 4.82 2.49
27 2.98 3.58 4.82 2.95
28 3.51 4.11 4.83 3.48
29 4.13 4.73 4.84 4.10
30 4.83 5.43 4.85 4.80
31 5.61 6.21 4.87 5.58
32 6.48 7.08 4.88 6.45
See next page
Calculation for down stream windguy arrangemnet
Windties are given from left bank to right bank
C/C wind-ties Cutting length of Inclined dist., Dw Horz. c/c dist.
No.
[m] wind-ties [m] [m] [m]
33 7.43 8.03 4.90 7.39
34 8.46 9.06 4.92 8.42
35 9.57 10.17 4.93 9.53
36 10.76 11.36 4.96 10.73
37 12.04 12.64 4.98 12.00
38 13.40 14.00 5.00 13.36
39 14.85 15.45 5.02 14.80
40 16.37 16.97 5.05 16.33
41 17.98 18.58 5.08 17.93
END
DESIGN OF WINDGUY ANCHORAGE ON SOIL
β+
β+
β+
β+