Polaris-12
Polaris, or the pole star, lies less than one degree
from the north celestial pole and has served as a
stellar beacon leading explorers and navigators to
their destination since the beginning of time.
Similarly, Infranor has been, and continues to be, a
leader in the manufacture of performance flood-
lighting products. The Infranor Polaris-12 continues
this leadership by offering proven reflector technologies
in a new architectural shape. Everything from 100W to
175W in the Polaris-6 and from 250W to 1000W in the
Polaris-12 is now available in one architectural family.
Table of Contents:
Features and Benefits . . . . . . . . . . . . . . 4 - 5
Luminaire Construction . . . . . . . . . . . . . 6
Mounting Options . . . . . . . . . . . . . . . . 7
Order Matrix . . . . . . . . . . . . . . . . . . 8 - 9
Luminaire Specifications . . . . . . . . . . . . . 10
Luminaire Beam Patterns . . . . . . . . . . . . . 1 1
Lighting illustrations . . . . . . . . . . . . 12 - 13
Photometric distribution . . . . . . . . . . 14 - 17
Application Information . . . . . . . . . . . 18 - 19
2
3
F e at u r e s a n d B e n e f i t s
DESIGN FORM
An aesthetically pleasing shape helps to accentuate the
surrounding architecture and makes this product ideal for
monument, sign, and facade lighting. Our precision die-cast
methods allow for sharp distinctive lines and eliminate the need
for most external fasteners. The efficient design (18.00" W x 15.41"
H x 12.33" D) includes integral heat sink fins for cooler operation
and longer component life and will operate lamps up to 400W
with an integral ballast and up to 1000W with a remote ballast.
MOUNTING
Heavy Duty Swivel:
40˚
As a standard feature the Polaris-12 includes the most robust, die-
cast swivel available in the market today. Regardless of mounting 140˚
Yoke: 160˚
PAT E N T E D A R C S T R E A M A L I G N E R
The Infranor Polaris-12 also comes standard with an Arc Stream
Aligner in all of the horizontally lamped metal halide options.
The Arc Stream Aligner is a patented device (pat. # 5,111,371)
that ensures that the arc stream itself is in the optical design
center. In normal installations, the effect of gravity causes the
arc to bow upward – away from the design center. The Arc
Stream Aligner is a cam-mounted device that allows for
rotation of the lamp and repositions the arc stream into the
focal point, increasing efficiency and optimizing optical
performance while decreasing unwanted spill light. arc stream aligner
4
R E C TA N G U L A R B E A M PAT T E R N S
For over 35 years, Infranor’s precision rectangular beam patterns while minimizing spill light into adjacent properties and the
have been the choice to illuminate prestigious architecture. night sky. Further, the efficiencies of rectangular beam patterns
Although the Polaris-12 is a new architectual shape, the often allow for a reduction in the total number of luminaires
luminaire utilizes Infranor’s time-proven reflector technology. needed. The optical assembly is manufactured as a unitized body
Specifiers may select from seven rectangular beam patterns that and can be quickly interchanged with other beam patterns to
provide the highest degree of uniformity on the targeted surface, adapt to field conditions.
SEALED SYSTEM
Unlike most systems that use a two-fastener hinging method, the Silicone O-Ring
Infranor Polaris-12 has a die-cast doorframe that attaches Sealing Gasket
securely with four (4) recessed and self-retained stainless steel (4) #10 Self-Retained
Stainless Steel
fasteners. This ensures that the doorframe retains its shape and doorframe screws
sponge silicone
O-ring gasket
Sterner engineers have developed a unique gasket system for use
in the Polaris-12. As the doorframe presses against the housing, DIE-CAST
two separate surfaces compress the gasket, forming a dual housing
ACCESSORIES
A special reveal has been engineered directly into the doorframe
and accepts all door-mounted accessories. This unique design
eliminates any chance of light leaks. The doorframe may be
removed for maintenance without detaching the shields. Top Shield four-sided shield
See order matrix on pages 8 and 9.
multi-louver shield
5
Luminaire construction
Reveal for
Mounting options
Four self-retained
stainless steel
Screws provide
secure
attachment,
eliminating
Quick Disconnect doorframe
distortion
and entry of
One-Piece Die-Cast contaminants
Aluminum Housing
sponge silicon
O-ring gasket
Optical
Assembly
Quick Access to
Ballast Compartment
integral
Ballast
Easy Access
For Wiring Wire Entrance
Sealed at Factory
lamp Options
6
mounting options
6.0" SQ.
1.69" Dia. Holes
WM PD
50˚
4.0"
21.75"
Yoke mount luminaire shipped with cord connector and 3' of 16/3 SJO cord.
5.62"
6.0" SQ.
3/
4"–10 Stud 3.44"
45˚
8.0"
95˚
4.7" 3/
4" Bolt
0.56" Dia. Holes
on 3.5" SQ.
Fixture Aiming Range
WB with wall bracket
7
INFRANOR POLARIS-12
ORDERING SEQUENCE
Item Sequence: 1 2 3 4 5 6 7 8 9 10
ORDER
NUMBER:
HOUSING LAMP BEAM VOLTAGE BALLAST MODEL MOUNTING SHIELD GENERAL FINISH
WATTAGE PATTERN STYLE OPTIONS OPTIONS OPTIONS
Notes: 1) ‘400MH’ only available with ‘SP’, ‘HPM1’ & ‘HPW1’ distributions. 6) ‘1000MH’ not available with ‘SG’ option.
2) ‘SP’, ‘HPM1’, ‘HPW1’ requires ED28 lamps in ‘400MH’. 7) ‘PCL’ Eye Dot Photocell not available in ‘1000MH’ or ‘480V’.
3) ‘400MH’ & ‘HPM’, ‘HPW’ distributions require ED37 lamps. 8) ‘DP’ option automatically doubles the fixture quantity unless otherwise specified.
4) ‘1000MH‘ uses remote ballast box. 9) ‘SG’ not available with ‘EC’.
5) ‘1000MH’ only available with ’RN’, ‘RM’, ‘RW’, ‘HPM’ & ‘HPW’ distributions. 10) Please supply metal color chip or supply RAL# for any ‘NS’ finish.
3. BEAM PATTERN
(*’SP’, ‘HP M1’ & ‘HPW1’ distributions require ED28 lamps in ‘400MH’.)
(**‘HPM’ & ‘HPW’ distributions require ED37 lamps in ’400MH’.)
(’1000MH’ only available with ‘RN’, ‘RM’, ‘RW’, ‘HPM’ & ‘HPW’ distributions.)
(SP=spot, BI=bi-polar, R=rectangular, HP=high-point, N=narrow, M=medium, W=wide.)
4. VOLTAGE 5. BALLAST
(*Core and coil ballast is high-power factor and rated for -20 F (-28.9 C) .)
‘
(*480V ‘ not available with ‘PCL‘ - Eye Dot Photocell option.) (* ‘1000MH‘ uses remote ballast box.)
6. MODEL STYLE
15.41" 15.41"
17.20"
21.69" 3.25"
1.81"
7.77"
6.30"
2.00" 0.81" for 3/4" mounting bolt
(supplied by others)
Fits 2.00" pipe (2.38" O.D.)
8
PL12
7. SWIVEL MoUNTING OPTIONS (’DP’ option automatically doubles the fixture quantity unless otherwise specified.)
(PD) Base Pad (ST) Stanchion (DP) Dual Post-Top Mount (WM) Wall Mount
(Anchors supplied by others.) Mount (Anchors supplied by others.)
6.25”
0.25”
(N)
All components steel Not Required
welded construction
(TS) Top Shield 17.67" 4.25" (EC)* Egg Crate (4S) Four Sided
17.67" 4.25"
17.67" 4.25"
14.68" 15.07"
15.07"
(BD) Barn Door (SG)* Polycarbonate Stone Guard (N) Not Required
17.67" 6.56"
1.94"
15.07"
9. GENERAL OPTIONS
(FL) Fuse Luminaire (SC) Safety Cable (PCL)* Eye Dot Photocell (N) Not Required
10. FINISH
9
INFRANOR POLARIS-12
FIXTURE DIMENSIONS & details
SWIVEL YOKE
EPA: 2.31 EPA: 2.31
FIXTURE WEIGHT: 43 LBS. FIXTURE WEIGHT: 41 LBS.
15.41" 15.41"
17.20"
21.69" 3.25"
1.81"
7.77"
6.30" 2.00"
0.81" for
3/4" mounting bolts
14.75" (supplied by others)
top ivew 14.31"
Fits 2.00” pipe
(2.38" O.D.) 7.55"
8.0" 4.0"
1000W remote box
Watertight cord connector
(2) supplied (4) clearance holes for 3/8” anchors (supplied by others)
In the interest of continuous product improvement, Sterner Lighting reserves the right to change specifications without notice.
Lamp and electrical specifications/availability subject to change by manufacturer without notice.
10
Luminaire bea m patterns
V xH V xH V xH
250W MH
400W MH
1000W MH
250W HPS
400W HPS
11
l i g h t i n g i l l u s t r at i o n s
12
SIGNAGE
MONUMENTS
13
photometric Distribution: 400W mh L A MP
27 CANDELAS
153680
18 10% MAX CANDELA
V E RT I C A L D E G R E E S
115260
9 76840
72 CANDELAS
38560
48 10% MAX CANDELA
V E RT I C A L D E G R E E S
28920
24 19280
90 CANDELAS
18744
60 10% MAX CANDELA
V E RT I C A L D E G R E E S
14058
30 9372
90 CANDELAS
10689
60 10% MAX CANDELA
V E RT I C A L D E G R E E S
8016.75
30 5344.5
Photometric distributions illustrated above are based on a 400W MH lamp. For other lamping options, please consult the applications department at Sterner Lighting.
14
InfraNOR hpm ITL Report #37411
90 CANDELAS
13493
60 10% MAX CANDELA
V E RT I C A L D E G R E E S
10119.75
30 6746.5
90 CANDELAS
9189
60 10% MAX CANDELA
V E RT I C A L D E G R E E S
6891.75
30 4594.5
90 CANDELAS
11594
60 10% MAX CANDELA
V E RT I C A L D E G R E E S
8695.5
30 5797
Photometric distributions illustrated above are based on a 400W MH lamp. For other lamping options, please consult the applications department at Sterner Lighting.
15
photometric Distribution: 400W hp s L a mp
45 CANDELAS
199590
30 10% MAX CANDELA
V E RT I C A L D E G R E E S
149692.5
15 99795
90 CANDELAS
94360
60 10% MAX CANDELA
V E RT I C A L D E G R E E S
70770
30 47180
90 CANDELAS
44050
60 10% MAX CANDELA
V E RT I C A L D E G R E E S
33037.5
30 22025
90 CANDELAS
24634
60 10% MAX CANDELA
V E RT I C A L D E G R E E S
18475.5
30 12317
Photometric distributions illustrated above are based on a 400W HPS lamp. For other lamping options, please consult the applications department at Sterner Lighting.
16
InfraNOR hpm ITL Report #37415
90 CANDELAS
21694
60 10% MAX CANDELA
V E RT I C A L D E G R E E S
16270.5
30 10847
90 CANDELAS
16787
60 10% MAX CANDELA
V E RT I C A L D E G R E E S
12590.25
30 8393.5
Photometric distributions illustrated above are based on a 400W HPS lamp. For other lamping options, please consult the applications department at Sterner Lighting.
17
applic ation inform ation
I E S - R E C O M M E N D E D I L L U M I N A N C E VA L U E S
sign lighting
MEDIUM DARK SURFACES 300 30
recommended guidelines
B E A M PAT T E R N S SETBACK
The rectangular narrow beam pattern (RN) is ideal for lighting Luminaire setback can vary depending on the results desired. If
facades and signs where long setbacks are necessary or for a textured surface is being illuminated and the desired effect is
providing a uniform wash on tall facades with short setbacks. to emphasize the texture of the surface, a short setback should
The high proportioned wide beam pattern (HPW) is be considered to reveal the depth of the texture. If a uniform
appropriate for providing an even wash on facades with medium wash or distribution is required, then a setback of two-thirds to
setbacks and is effective in controlling spill light by placing a three-quarters the height of the structure should be considered.
high proportion of the light above the center beam. The variety
of beam spreads making up the spread between SP and HPW L U M I N A I R E S PA C I N G
provide solutions for all possible lighting needs. Depending on the lighting effects desired and the beam pattern
used, luminaire spacing should range between one and two
As the possibilities of aiming options and solutions for times the luminaire setback. With the wide variety of beam
lighting applications are unlimited, the following information patterns available with the Polaris-12, there are many tools to
serves to provide a general rule of thumb in determining select from for all of your lighting design challenges.
beam spread requirements for applications where uniform
illumination is required. SHIELD OPTIONS
Luminaire shield options are available. Shields will affect the
published photometric distributions. Please consult the factory
for assistance.
18
recommended guidelines (cont ’d)
Illustrated in the following application is a 25' high and 50' high general guideline for selecting the appropriate beam spread for
wall and varying luminaire setback positions. Also shown are the applications requiring an even illumination of the surface. Please
recommended rectangular beam patterns suggested for the given consult the factory for assistance in applying these and other beam
luminaire setback ranges. The example below is meant to be a spreads and for assistance with your lighting design.
50'
25'
setback
ed 0
d
en rn
m te 5
m
o at
ec m p 10
r a
be
15
RN 20
25
RM 30
M
HP
levels required.
RM
T E C H N I C A L A S S I S TA N C E
Just as there are many stars in the nighttime sky, there are many Canaveral. This same staff of expert application engineers is
different solutions available for a successful lighting design. Our available to assist with all of your lighting design challenges.
experienced staff of application engineers has been involved Please consult the applications department at Sterner Lighting
with the lighting design for applications ranging from simple for assistance with your design.
sign lighting to the lighting of the shuttle launch pad at Cape
19