Vous êtes sur la page 1sur 40

Products

for Efficient Energy & Process Management

elmeasure.com
WHAT ARE WE?

A SPARKLE TO KEEP THE


ENERGY ALIVE FOREVER.

15+ Years in the Product Versatility to Tailor-made Solutions


Energy Business 500+ & counting for 25+ Industries

60,000+ & Growing 5 Million products Footprints in 45+


no. of Happiest Clients in the field Countries

ABOUT US

Elmeasure India is a fast growing technology leader in the field of energy management. The Return on Investment is typically less
than 12 months and the user can have recurring profits. Elmeasure India Pvt. Ltd. was promoted in 2004 by a young team of
entrepreneurs with a collective experience of more than a decade in the field of energy management.
Elmeasure has its Headquarters at Bangalore and state of the art manufacturing facilities at Bangalore and Coimbatore. Elmeasure
is renowned for its technical know-how in the field of energy management. It is backed by a pool of experts to invent, customize &
serve the needs of 25 + industries over the globe.

Elmeasure is a complete package of 500+ product varieties, 10+ Customizable Solutions & 300+ brains with stupendous & steady
growth every year that is not same & not small. As a result, it was the fastest growing manufacturing company of the year 2016, 2017 &
runner-up in the Best SME Manufacturing Company in 2017.
One Platform,
Many Possibilities...
Energy | Costs | Manpower | Environment

Monitor Analyze Communicate Control

Energy | Process | Dynamic dashboard | WiFi | Zigbee | GPRS | On-premises | Remote |


Water | Gas KPI reports | Real time 4G | Ethernet | RS485 | Scheduled
alerts & notifications Modbus | MQTT | LoRa
Smart Monitoring
Smart Basic Meter (Sleek) ...................................................... 2

Smart Basic Meter (Micro Alpha) .......................................... 3

Digital Multifunction Meter (LG) ........................................... 4

DC Energy Meter (EDC) ........................................................... 6

Generator Monitoring Unit (GD) .......................................... 7

Branch Circuit Monitor (BM) .................................................. 8

Smart Controlling
Power Factor Controller (iPFC) .............................................. 10

Earth Leakage Relay (iELR) ..................................................... 11

Energy & Process Control (EPM | EPC) ................................ 12

Motor Protection System (MPS) ............................................ 13

Demand Controller (EN | PN) ................................................ 14

Power Quality Meter (iM) ....................................................... 17

Smart Resource
AC Static Watthour Meter (PE) .......................................... 20

ACCL .......................................................................................... 24

Portable Power Quality Analyzer (iD-LOG-8000) ................. 26

Portable Power Analyzer (iD-LOG-7000) .............................. 28

Smart Networking
Gateway (GW) .......................................................................... 32

Accessories
Current Transformer (CT) ...................................................... 34
SMART
MONITORING
ENGINEERED FOR EASE OF INSTALLATION
WITH ACCURATE MEASUREMENT

Multifunction Meter
High performance digital meter for simultaneous
measurement of electrical qualities like voltage,
Energy Metering current, Power, energy, frequency, power factor, along
Designed to offer precise energy with process parameters.
measurement for power metering and
network monitoring applications

Multi-Channel Meter
Compact meters with the ability
Programmability to monitor multiple channels
User friendly and site that are ideal for data centers,
programmability of apartments, commercial
voltage and current complexes billing and load
based on single phase pattern studies.
&three phase
applications.

For monitoring energy parameters, elmeasure products has developed a wide range of AC/DC measurements, designed with compact
enclosures, easy-to-use, and cost effective energy meter. Smart energy meters can be provided with communication port to connect to
your BMS/EMS systems. Smart monitoring products are ideal for industrial panels, gen-sets, solar, pump control panels, genset, solar and
UPS applications.
SL

L1 SMART BASIC
L2

L3
METER
Ammeter | Voltmeter | VAF Meter | Power Meter

FOR COST EFFECTIVE AND EASY INSTALLATION


WITH FULL PROGRAMMABILITY AT SITE!

SL 1330

SL 1340

SL 1300

SL 4300
Features : Parameters:

SL 3A

SL 3V
SL A

SL V
True RMS.
INSTANTANEOUS
Average & phase wise information. V
Measurement range 20mA to 6A. V1 V2 V3 V12 V23 V31
Programmable primary / secondary for both Voltage & Current making A
wider range of operations – stocking becomes simple. A1 A2 A3
Hz
Universal Auxiliary input 40-300V AC/DC.
RPM
Built in power supply for SL V and 3V. PF PF1 PF2 PF3
Auto-scrolling. W W1 W2 W3
Auto-scaling of decimal point. VA VA1 VA2 VA3
VAR VAR1 VAR2 VAR3
Low PT. CT burden.
OPTIONAL
Alerts for 120% Over Voltage, 80% Under Voltage of PT Primary, 100% Class 0.5
Over Current of CT Primary in 3 row. Class 0.2
Voltage & Current terminal on opposite side for safety and easy wiring. 50A projection CT
100A hanging CT
Tamper proof
*Optional 0.8" display available for SL 3A & 3V. (MOQ applies)
Additional Features:
4 Digits 1 row, 14 mm height bright red LED for 1 row
Technical Specification:
4 Digits 3 row, 14 mm height bright red LED for
SL 1300/1330/1340/4300. Specification Description
Accuracy: Class 1.0 (Default) Class 0.5 (Option). Frequency 0.5%
Patented alpha numeric display 4 Digits, 3 row, 14 mm height.
default.
Simultaneous sampling of Volts & Amps.
Sensing/ True RMS, 1 Sec. update time
Displays more than 13 basic parameters i.e, VLL, VLN, A, Hz. Measurement:
RPM measurement for generator in SL 1300/4300. Input Voltage: 4 Voltage inputs (V1 V2 V3 VN); (Range 80 to 550V LL)
PT primary programmable upto 999kV Nominal 415V LL
W, VA, VAR, PF parameters available in SL 4300.
(415/415 in SL 4300)
Burden: 0.2VA Max. per phase
Input Frequency: 45 - 65 Hz
Mechanical Specification Input Current: Current inputs (A1 A2 A3) 20mA - 6A
(Field configurable 1A or 5A).
Primary programmable up to 99kA (8000A in SL 4300)
Overload: 10A max continuous, 50A max for 3 Sec
90-0
+2 Burden: 0.2VA Max, per phase.
96
90 Aux-Supply 40 – 300V AC / DC, 24V DC optional.
(control power): Burden: 4 VA Max
30

+2
Display resolution: 4 digits display with 14mm height
90-0
Weight: Unpacked: 275 gms, Packed: 350 gms
90 Torque 1 N-m
96

Wire gauge 11 AWG

41

2 elmeasure.com
µA+

SMART BASIC
METER
Ammeter | Voltmeter | DC | RPM & MPM

BASIC PARAMETERS MEASURES PRECISELY!

AMMETER - µALPHA+ 3A/A


Features :
Displays Amps for µAlpha+ A and Amps (Avg & PW) for 3A.
True RMS.
Field programmable CT primary and secondary.
Four Digits resolution with auto scaling.
Models: µAlpha+ 3A (3 Phase); µAlpha+ A (single phase).
Field programmable Star (Wye) or Delta or Single Phase configuration.
Average & Phase wise information.

VOLT METER - µALPHA+ 3V/V


Displays VLL, VLN (Avg & PW), F, for µA+ 3V. VLL / VLN for µA+ V
Additional Features: Models: µAlpha+ 3V (3 phase measurement); µAlpha+ V (Single Phase).
Universal auxiliary input 80 - 300V AC (Optional: 40-300V AC/DC).
Auto-scrolling.
Available in single row DIN rail version (90 x 90mm). Minimum order DC METER - µALPHA+ ADC/VDC
quantity apply.
DC Vin - 75mV or 100mV or 10V or 100V or 500V default 48 VDC.
Optional direct measurement upto 60A or 100A, 200A max. using
Hanging CT. (ID 25mm) 0-20 mA / 4-20 mA input options. 4 Digits resolution for ADC.
AC auxiliary from 80-300V (40-300V AC/DC optional)
Field programmable full scale or offset value.
µALPHA+ ADC

µALPHA+ VDC

µALPHA+ RPM
µALPHA+ 3A

µALPHA+ 3V
µALPHA+ A

µALPHA+ V

Parameters: RPM/MPM METER - µALPHA+ RPM/MPM


DC Vin - 75mV or 100mV or 10V or 100V or 500V.
INSTANTANEOUS
0-20 mA / 4-20 mA input options. 4 Digits resolution for RPM.
V
DC auxiliary supply option (40-300V AC/DC optional).
V1 V2 V3 V12 V23 V31
Field programmable full scale or offset value.
A
A1 A2 A3
Hz
RPM/MPM Technical Specification:
Voltage DC
Current DC Specification Description
OPTIONAL Accuracy: Class 1.0 (Default) as per IEC 62053-21, Frequency 0.5.
Class 0.5
Sensing/ True RMS, 1 Sec. update time
100A hanging CT
Measurement:
Note : DC measurement Accuracy Class 1.0FS, Class 0.5FS (optional)
In DINrail version other than RS485, no other option is possible Input Voltage: 4 Voltage inputs (V1 V2 V3 VN); (Range 80 to 550V LL)
PT primary programmable upto 999kV
Nominal 415V LL
Burden: 0.2VA Max. per phase
Mechanical Specification Input Frequency: 45 - 65 Hz
Input Current: Current inputs (A1 A2 A3) 20mA - 6A
(Field configurable 1A or 5A)
Primary programmable up to 99kA
90-0+2
Overload: 10A max continuous, 50A max for 3 Sec.
90
Burden: 0.2VA Max. per phase.
45
42-0+2
Aux-Supply 80 - 300V AC 40-70Hz
48 42
(control power): Burden: 4VA Max
Display resolution: 4 digits display with 10mm height
96 Weight: Unpacked: 250 gms, Packed: 325 gms
56
Torque 1 N-m

Wire gauge 11 AWG


Note: Additional error of 0.05% of full scale, for meter input current below 500mA

elmeasure.com 3
LG

DIGITAL
MULTIFUNCTION METER
Basic | Power | Energy | Dual Source Meter | Load Manager

SIMULTANEOUS MEASUREMENT OF VARIOUS


ELECTRICAL PARAMETERS!

Parameters:

LG 1119
LG 2119
LG 3120

LG 5110
LG 5120
LG 2520
LG 2600

LG 6425

LG 6435

LG 6445

LG 6400
Features :
Accuracy Class 1.0 (IEC 62053-21), 0.5s (IEC 62053-22) option. GROUP 1 (BASIC)
V V1 V2 V3 V12 V23 V31
Patented alpha numeric display with bar graph 14 mm height, 4 Digits
A A1 A2 A3
3 row for 64xx series,10mm for single row.
Hz
Available in LED 1 row 6 Digits, LCD 1 Row 7 Digits & LED 3 Row 4 RPM
Digits each. Phase angle V/A
Field programmable Star (Wye) or Delta or Single Phase Unbalance V/A
GROUP 2 (POWER)
configuration.
PF PF1 PF2 PF3
Programmable PT, CT ratio upto 2000 MVA. W W1 W2 W3
Wide measurement range 1: 600 (10mA – 6A). VA VA1 VA2 VA3
GROUP 3 (ENERGY)
Graphical representation of programmable load available for
Wh (Import)
(A, W, VA)
VAh (Import)
High sampling rate 128 samples/cycle simultaneous sampling of Load Hours (Import)
Volts & Amps. ON Hours
High & Low measurements for Voltage and Current (Last one minute Individual phase energy via
of data). communication
Number of interruptions
Load efficiency can be monitored for 5 different programmable slots
CO2
along with time.
GROUP 4 (REACTIVE)
Non re-settable Over voltage Hour in diagnostic communication VAR, VAR1 VAR2 VAR3
mode for healthiness of system. kVARh inductive (Import)
Sliding demand for W, VA, VAR (option for LG 6400). kVARh capacitive (Import)
GROUP 5 (ENERGY EXPORT)
Energy display programmable – counter based or resolution based. Wh (Export)
Energy resetting at 9999999 kVAh x MF. VAh (Export)
Load Hours (Export)
Individual phase energy through communication - helps branch
GROUP 6 (REACTIVE EXPORT)
monitoring, better load distribution study.
VAR VAR1 VAR2 VAR3
Front LED pulse 16000 imp/kWh of secondary input. kVARh inductive (Export)
Optional IO module available for DI, DO, AI, AO. kVARh capacitive (Export)
GROUP 7 (THD)
Auto configuration through communication.
Voltage THD upto 15th order
Communication with PCs, PLCs, DCS through optically isolated Current THD upto 15th order
RS485 serial interface. DEMAND
Safety Construction : Self extinguishable V0 plastic. Demand W VA VAR
Max. Demand W VA VAR
Clearance and creepage distance meets UL safety standard. OPTIONAL
Finger touch proof terminals to voltage and current connections. Class 0.2S
Class 0.5S
RS 485
Mechanical Specification # 50A projection CT

# 100A / 200A hanging CT

DINrail - 4Din (LED only)


90-0+2 90-0+2
DINrail - 80A Direct Current
96 96
90 90 *TCP/IP Option with 14GB
30 46 Memory

90-0+2
+2
90-0 Programmable to either Wh or VAh. Any one parameter for 1119 # MOQ applies
* Restricted additional optionOnly through Communication Optional
90 90
96 96 LG 6325: any 2 groups can be programmable GROUP 1 GROUP 2 GROUP 3 GROUP 4
LG 6335: any 3 groups can be programmable
67 GROUP 5 GROUP 6 GROUP 7
72 LG 6345: any 4 groups can be programmable
41 57

Multiplication factor for counter based energy mode


90
Full Scale in Watts : 0.4k 4.01k 40.1k 400.1k 4M 40 M 400M
45

3 × VPri x Apri /1000 to to to to to to to


4.0k 40k 400k 4000k 40 M 400 M 4000M

49
Multiplication Factor: 0.01 0.1 1.0 10 100 1000 10000

Unit of display kWh MWh GWh

4 elmeasure.com
Technical Specification:
LG 1000/3000/5000 Series LG 2000 Series LG 6000 Series
GENERAL CHARACTERISTICS
Sensing / Measurement True RMS, 1 Sec update time, 4 Quadrant Power & Energy
Rated voltage 50-600 VLL
Rated current 10mA-6A
Frequency 45-65 Hz
Poles description 1P + N, 3P, 3P + N
Sampling rate 128 samples/cycle
Measured Accuracy Class Class 1 default / Class 0.5S / Class 0.2 as per IEC 62053-22 (Optional).
Display type LED 1 row LCD 1 row LED 3 row
Instantaneous Digits 4 4 4
Integrated Digits 6 7 8
Programmable Setting 110 or 415V LL Nominal & Primary Programmable up to 999 kV. Burden: 0.2VA Max. per phase
Permissible overload 120%, Burden:0.2VA per phase
External Fuse Rating 200mA slow blow
CT PT Ratio Max 2000 MVA Programmable
Auxiliary supply 80-300 V AC/DC (40 - 300V AC/DC Optional)
Power consumption 4VA
Data update rate 1sec

COMMUNICATION
Device ID & Parity 1 to 247 & Odd, Even, None (Preferred Even)
Protocol & Interface Modbus. RTU & RS 485
Baud rate 2400 bps to 38.4k bps (Preferred 9600)
Isolation 2000 volts AC isolation for 1 minute between communication and other circuits

ENVIRONMENTAL CHARACTERISTICS
Operating temperature -10°C to + 55°C (14°F - 131°F)
Storage temperature -25°C to +70°C (-13°F - 158°F)
Humidity 5% to 95% non-condensing
Altitude Below 2000 mts
Measurement Category CAT III
Pollution degree 2 (As per IEC 61010)

PROTECTION CLASS
Ingress protection IP 51 ( IP 54 front facia optional ) & Double Insulation ( As per IEC 61010-1)

ELECTROMAGNETIC COMPATIBILITY
Electrostatic discharge IEC 61000-4-2g
Immunity to Electromagnetic IEC 61000-4-3g
RF Fields
Conducted Immunity IEC 61000-4-6g
Immunity to Magnetic Fields IEC 61000-4-8g
Immunity to voltage dips and IEC 61000-4-11g
interruptions
Fast transient IEC 61000-4-4g
Immunity to surge waves IEC 61000-4-5g
Impulse voltage CISPR- 22
Conducted and radiated emissions

SAFETY AND STANDARDS


Construction IEC/EN 61010-1 ed.3, CAT III, 300 V LN / 600 V LL , Protection class II.
Standards UL 61010-1, IEC/EN 62052-11

Mechanical characteristics
Weight Unpacked: 275 gms, Packed: 350 gms
Dimensions 96x96 mm
Torque 1 N-m (For 5A)
Wire Gauge 11 AWG (For 5A)

elmeasure.com 5
EDC

DC ENERGY
METER
Multi-channel DC Energy | Voltage/Current full scale

SMART DEVICE FOR ALL RENEWABLE


ENERGY RESOURCES!

Features : Applicable Standards :


Single meter measures multiple channels. DIN 40050 Degrees of protection provided by enclosure for electrical
EN 60529 equipment against ingress of solid foreign objects.
Differential current input for all the current channels.
Voltage Full scale programmable. DIN / Electrical measuring transducers for converting AC electrical
Current full scale programmable independently. IEC 688-1 quantities into DC electrical quantities.
Reverse lock option for not accumulating the reverse current energy.
IS 12784 Electrical measuring transducers for converting AC electrical
This can be used for the better study of charging and discharging
quantities into DC electrical quantities.
circuit.
Programmable shunt secondary 50mV or 75mV.
Energy display programmable-counter based or resolution based.
Energy resetting at 999999 x PT Primary x CT Primary Technical Specification:
Auto scaling of kilo, mega decimal point. Specification Description
Optional programmable relay output maximum 1 and tripping time
Accuracy: Class 1.0 FS, Class 0.5 FS (optional)
upto 180 seconds.
Display 1Row 6 Digits for EDC4100 and EDC1100.
resolution:
Input Voltage: One Voltage Input (48VDC Factory Default).
Additional features for EDC 1100 Varieties of range in Voltage like 48VDC, 100VDC,
150VDC, 300VDC, 600VDC, 800VDC (factory settable).
Displays Voltage, Current, Watts & Energy for 1 channel Primary Programmable range: 0.100 to 999.9kV .
Optional RS485 communication.
Input Current: One / Four Current Input (50mV, 75mV Shunt type).
Individually Programmable primary current.
Range: 0.100 to 999.9k .
Additional features for EDC 4100
Aux-Supply: 40 - 300V AC/DC, 40-70Hz
Displays Voltage for 1 channel, Current, Watts & Energy for 4 channel Burden: 4VA Nominal.
Communication Parity: Odd, Even, None (Preferred Even)
Optional RS485 communication.
RS485 interface : Baud rate: 4800 bps to 19200 bps. (Preferred 9600 bps).
Isolation: 2000 volts AC isolation for 1 minute between
communication and other circuits.
Weight: Unpacked: 300 gms, Packed: 400 gms
Mechanical Specification
Operating -10oC to +55oC (14oF to 131oF).
DIN Rail Panel Mount Temperature:

90-0+2
Storage -25oC to +75oC (-13oF to 581oF).
67 55 Temperature:
90 90

Humidity: 5% to 95% non condensing.


Ingress protection: IP 51 (IP 54 front option).
96 90-0+2

90
Torque: 1 N-m
96 90
45
Wire gauge: 11 AWG

49

6 elmeasure.com
GD

GENERATOR
MONITORING UNIT
Counter & LED Display | Pulse Output

GENERATOR MONITORING DEVICE


WITH DUAL DISPLAY!

Features : Multiplication factor for counter based energy mode

Dual display: kWh 6½ Digits counter, VAF 4 Digits LED (GD 3110) - Full Scale in Watts : 0.1k 1.01k 10.1k 100.1k 1M 10 M 100M
Reduces the need of multiple meters. 3 × VPri x Apri /1000 to to to to to to to
1.0k 10k 100k 1000k 10 M 100 M 1000M
Simultaneous display of kWh and V or A or Hz.
Multiplication Factor: 0.01 0.1 1.0 10 100 1000 10000
Displays kWh and VLL, VLN, A (Average and Phasewise), Hz.
Unit of display kWh MWh GWh
CT, PT settings through front panel keys. No DIP switch settings hassles
(One common CT, PT settings for all parameters)
Programmable for Single phase and Three phase applications.
Forward kWh integration even with incorrect CT polarities connections Technical Specification:
(Reverse lock option).
Specification Description
Optional 50A, 100A or 200A hanging CT (ID is 25 mm).
Accuracy: Class 1 (Default) as per IEC 62053-21. Class 05 (Optional)
Reduces cost and simplifies panel wiring.
Sensing/ True RMS, 1 Sec update time for VAF. 4 Quadrant with
Suitable for Generator applications. Measurement: forward kWh accumulation.
Input Voltage: 4 Voltage inputs (V1 V2 V3 VN). Programmable 110 or
415V LL. Nominal (Range 80 to 550V LL).
Primary Programmable up to 999 kV.
Ordering Information:
Burden: 0.2VA Max. per phase.

Accuracy Class 1.0 Input Frequency: 45 - 65 Hz


Accuracy Class 0.5 (Optional) Input Current: Current inputs (A1 A2 A3) 50mA - 6A
Pulse Output (Optional) (Field configurable 1A or 5A)
Primary programmable up to 99 kA.
Tamper Proof (Optional)
Overload: 10A max continuous, 50A max for 3 Sec.
Burden: 0.2VA Max. per phase.

Aux-Supply 80 - 300V AC/DC.


(control power): Burden: 4VA.
Mechanical Specification
Display type: 10mm height, bright red LED display.
Display resolution: Stepper counter 6½ Digits for kWh,
+2
90-0
10mm height, bright red LED display for VAF.

90 CT Ratio: 2000 MVA programmable.


Weight: Unpacked: 300 gms, Packed: 400 gms

+2
Torque 1 N-m
90
-0

90 Wire gauge 11 AWG

96

96
55

elmeasure.com 7
BM

BRANCH CIRCUIT
MONITOR
Multi Channel Load Manager | Power Distribution Unit/System

COMPACT DEVICE TO ENROUTE


MULTIPLE CHANNELS!

Features : Technical Specification:


Multi-channel data collection. Specification Description
3 Phase, 4 channels or Single phase 12 channels Accuracy: Class 1.0 (Default) as per IEC 62053-21,
Displays Basic, Power and Energy parameters. Class 0.5 as per IEC 62053-22 (Optional).
Optional Pluggable Zigbee communication or Ethernet (Default RS 485). Sensing/ 1:600 for channel 1 & 2,
Space saving compact design for easy installation into existing panel Measurement: 1:120 for channel 3 & 4
boards.
Sensing/ True RMS, 1 Sec update time; 4 Quadrant Power & Energy
True RMS measurements.
Measurement:
Simultaneous sampling of Volts & Amps.
Input Voltage: 4 Voltage inputs (V1 V2 V3 VN) Programmable 110 or
Accuracy class 1.0 as per IEC 62053-21, Class 0.5 as per IEC 62053-22. 415V LL Nominal (Range 80 to 550V LL) Primary
User programmable password protection. Programmable up to 999 kV. Burden: 0.2VA Max. per phase.
Energy resetting @ 999999 KVAh × Transformer ratio.
Displays more than 25 parameters - Basic [VLL, VLn, A (Average & Input Frequency: 45 - 65 Hz
Phasewise), F ], Power [W, PF, VA (Total & Phasewise)] and Energy [Wh, Input Current: Current inputs (A1 A2 A3), 4 Channels - Each channel is
LH]. independently configurable. Primary Programmable
Optional Ethernet with 14GB memory for IOT device. up to 99 kA.
Note: Customization can be done for other parameters provided volume justify CT output : Can be upto 1000 mV or 100 mA from Split core
CT or Hanging CTs - Manufacturing option.
Applications : Aux-Supply 80 - 300V AC / DC, 40-70Hz.
Burden: 4VA Max.
For remote reading and control, the BM is supported by ELNet
Software, designed for remote setup and data viewing and analysis. Display resolution: 1 row 6 Digit for Integrated, 4 Digits for Instantaneous

Building Management System: With the open modbus protocol, the CT PT Ratio Max: 2000 MVA Programmable.
BM can interface any system, such as building management, HMI etc. Communication Parity: Odd, Even, None (Prefered Even)
Compact : Ideal for Data Center. RS485 interface: Baud rate: 4800 bps to 19200 bps. (Preferred 9600 bps).
Isolation: 2000 volts AC isolation for 1 minute between
Ideal for apartments / commercial complexes billing and load pattern communication and other circuits.
study on individual phase.
Weight: Unpacked: 275 gms Packed: 350 gms (weight of CT excluded)
Individual phase kWh measurement provides user flexibility of
measuring 3 phase 4 channels or single phase 12 channels.
Primary current can be independently configured making it ideal for
any kind of industry or upgradation. SCHEMATIC DIAGRAM
Note: Additional error of 0.1% of full scale, for meter input current below 500mA for 5A setting Optional: Zigbee | WiFi | Ethernet | GPRS Module with
memory up to 14 GB

Mechanical Specification A/C Load LMS


Data
Center
Motor/ Pumps
Load MODBUS

67
72

90

45

49
Meter 1 Meter 2 Meter 32

Current Transformers :

Hang on CT- 5A or 50A or 100A or 200A Up to 100A, 16mm ID Clip on CT-5A | 50A | 100A | 250A Split Core CT-100A | 400A | 1000A

8 elmeasure.com
SMART
CONTROLLING
INTELLIGENT DEVICE TO MONITOR AND
MAINTAIN ELECTRICAL PARAMETERS
IN THE REQUIRED
RANGE

Range of measurement
Controller’s are featured to allow both flexibility as well
as precision to operate over a wide range of input
Fault Detection voltages, current and output power levels
Designed to detect faults, Over voltage/current,
Under voltage, Phase missing, leakage, Neutral
Harmonics to assure safe, reliable operation
under any conditions.

Remote Monitoring
High-end multifunction meter
for comprehensive energy
Demand management and to enable
Management remote monitoring of the device
User friendly
demand controllers
to forecast demand
and cut off load
with site
programmability of
demand
parameters such
as kVA, kW, kVAR.

Maximum demand controllers, power factor controllers, earth leakage relay, power quality meters are developed for monitoring controlling
of energy and power quality parameters. Energy efficient meters such maximum demand controllers provides precise demand
management with 1 sec. update for demand. Smart controlling products are ideal for Process management, Maximum demand control &
management ,monitoring critical load,incomers, and HT panels Energy accounting & balancing for automotive, mobile and industrial
applications.
iPFC

POWER FACTOR
CONTROLLER
Current | Voltage | Frequency | PF | VAR | 6/8/12 stage control

INTELLIGENT DEVICE TO MAINTAIN THE POWER


FACTOR IN REQUIRED RANGE!

Features : Advantages
Three phase sensing with Three CT or Single CT (Balanced Load) Three phase sensing gives accurate measurement of PF.
Intelligent Power Factor Controlling based on the capacitor bank Fault Detection (Over compensation, Under compensation, Over voltage, Over
switching history (Number of operations, ON time) improves the current, Under voltage, Under Current, Over harmonics for voltage and
capacitor life time. current).
6 or 8 or 12 switching relay outputs. Automatic or Manual Control (manual control with power backup option).
Automatic or manual control (manual control with power backup Increased capacitor life - capacitor switching based on history - ON time /
option). number of switching.
User programmable:
- Star/Delta.
- Lead and Lag limits. Applications:
- PT and CT ratios.
- CT secondary. In all Incomers.
- Minimum switch ON time (4-999 seconds) default 20s. Fixed power factor corrections individual (e.g. motor, transformers,
- Minimum discharge time (4-999 seconds) default 50s. lighting, etc.)
- Minimum capacitor on time (4-999 seconds) default 20s.
Group fixed power factor correction (several equipments connected in a
- Minimum sensing current for controlling operation
group).
100mA - 500mA.
- User programmable capacitor value. Capacitor banks of tuned and detuned.
Fault detection (Over compensation, Under compensation, Over Harmonic trap applications (e.g. UPS, Frequency Drives and Converters,
voltage, Over current, Under voltage, Under current, Over etc.)
harmonics for voltage and current).
Displays VLL, VLN, Amps (Average and Phasewise) Frequency, W, PF,
VAR (Total and Phasewise) Wh, PF Avg. Technical Specification:
Four quadrant operation. Specification Description
RS 485 communication interface (Optional). Input current: Current inputs (A1 A2 A3) 50mA - 6A (Field configurable
1A or 5A). Primary Programmable up to 99 kA.
Overload: 10A max continuous, 50A max for 3 Sec.
Burden: 0.2VA Max. per phase.
Input voltage: 4 Voltage inputs (V1 V2 V3 VN) Programmable 110 or 415V LL
Mechanical Specification: Nominal (Range 80 to 550V LL) Primary Programmable up to
999 kV. Burden: 0.2VA Max. per phase.
Input Frequency: 45-65 Hz
Sensing/ True RMS, 1 Sec update time. 4 Quadrant Power & Energy.
90-0+2
55 Measurement:
90
Accuracy: Class 1.0 (default) as per IEC 62053-21, Class 0.5 as per
IEC 62053-22 (Optional).
96 90-0+2
Aux-Supply : Control Power: 180 - 300V AC/DC, 40-70Hz.
96 90
Burden: 10VA Max.
CT PT Ratio Max: 2000 MVA Programmable.
Relay SPST, 2A @ 240V.
contact rating:
Display 1 row, 4 Digits for instantaneous and 6 Digits for integrated
Resolution: (10mm height).
Weight: Unpacked: 350 gms, Packed: 450 gms.
*Note: Depth will be 10 mm more based on the relay/connector accommodation. Communication Parity: Odd, Even, None (Prefered Even)
RS485 interface: Baud rate: 4800 bps to 19200 bps. (Preferred 9600 bps).
Isolation: 2000 volts AC isolation for 1 minute between
communication and other circuits.

Torque 1 N-m
Wire gauge 11 AWG
Note: Additional error of 0.1% of full scale, for meter input current below 500mA

10 elmeasure.com
iELR

EARTH LEAKAGE
RELAY
Earth leakage current | Trip time

DETECT THE LEAKAGE CURRENT IN AN INTELLIGENT


ELECTRICAL DEVICE!

Features : Advantages
True RMS measurement. Microcontroller based design provides higher technological advantage
Clearance and creepage distance meets UL 61010 safety standard. Peak detection and value display helps in analysis and corrective action.
Inverse curve - trip time is inversely proportional to fault current. This Password protection for security against mishandling.
ELR is Intelligent, when the leakage current is 10 times higher than the Current sensitivity wider range 30mA - 30A and no limitations on set current.
set current, it trips 10 times faster.
Programmable trip time 30ms - 30s with wider choice to suit different industry.
Field programmable trip current and trip time through front panel keys
Selection through soft keys (No DIP switches) provides better IP protection and
with password protection.
longer life.
Continuous leakage current display (Programmable) - Leakage current Continuous earth leakage value display helps online loss analysis
continuously displayed to enhance the user to understand the quality (Programmable).
of Electrical network / Machine online. This can be disabled through
setup if required. Intelligent tripping based on T 1/A gives faster and reliable protection.
Auto scrolling of trip information and peak fault current provides better analysis.
Continuous display of trip leakage current (Programmable) - In case of
tripping, iELR captures and displays the tripped current with 4 Digits
resolution, which helps the user to analyze and correct the problem. Technical Specification:
This can be disabled through setup if required.
iELR 200D iELR 300 iELR 400D
Continuous scrolling display for set current and set time.
Manual test and reset keys. Input current: 30mA to 1A Default (30mA to 30A Optional)

RS485 communication option. Input Voltage: NA NA 50 - 550V LL


Trip Current: Programmable
Auto Configuration through communication.
Tripping time: 100 mS - 30 Sec
Reset through communication in trip condition
Contact Rating: 2Amps @ 240V AC / 24V DC
Accuracy: Class 2.0FS
Applications: Auxiliary supply: 80 - 300V AC/DC, 4VA Max

Protects control panels and switch boards from flame leakage. CBCT: Round , Rectangular
Core Balance: CT type : Tape wound limited round size
Protects motors / transformers / feeders / generators etc., from earth
option for epoxy coated and plastic version.
leakage.
Display: 4 Digit
Hazardous and sensitive industries like oil refineries / pulp industries /
electrical distribution etc., can be protected. Mounting Type: DIN rail Panel Mount DIN rail
Mechanical 2 DIN: Panel Mount: 4DIN:
Complete protection for control engineering and mining industry.
specification: 90×36×67 mm 96×96×30 mm 90×72×67mm
Cutout:
90-0+2 x 90-+2 mm
Core Balance Current Transformer - CBCT
Communication Parity: Odd, Even, None (Prefered Even)
CBCT Specification RS485 interface: Baud rate: 4800 bps to 38400 bps. (Preferred 9600 bps).
Input Range : 30mA to 1A Default (30mA to 30A Optional) (Optional) Isolation: 2000 volts AC isolation for 1 minute between
communication and other circuits.
Torque 1 N-m
Round Diameter: (Tape Wound) Wire gauge 11 AWG
Inner Diameter 45mm, 60mm, 100mm,
150mm, 200mm, 250mm, 300mm
Trip Characteristics:

Round Diameter: (Case mounted)


Inner Diameter 38mm, 57mm,
92mm, 120mm, 210mm

Plastic Epoxy
Rectangular: (Tape Wound)
150×50mm, 250×100mm,
300×100mm, 350×100mm,
400×125mm, 400×200mm,
500×225mm, 500×200mm.
(Any other sizes subject to availability)

elmeasure.com 11
EPM | EPC

ENERGY & PROCESS


MONITOR | CONTROL
Real-Time Monitoring | Improve Productivity

DEVICE TO MONITOR ENERGY & PROCESS


TOGETHER!

Features : Additional Features: EPC 5110D


True RMS measurement. High & Low measurements for Voltage and Current (Last one minute of
Simultaneous sampling of Volts & Amps. data).

Energy display programmable-counter based or resolution based. Digital Input programmable for high frequency (72000 RPM) or low
frequency (6RPM)
Energy resetting at 999999 kVAh × MF for EPM and
99999999 kWh/kVAh for EPC. Displays last one minute RPM. Cumulative RPM through RS 485.

Positive energy accumulation even with CT polarity reversal, reverse Optional: Digital Input (5-24V), Analog input (4–20 mA / 0–20 mA), Digital
lock programmable. output (Relay, 2A) programmable up to 18 different parameters for each
relay making as mini PLC.
User programmable password protection.
ON and OFF time for low-frequency input for the better understanding of
Auto scrolling.
breaks (avoid glitches).
Auto scaling of Kilo, Mega, Giga and Decimal point.
Low PT, CT burden.
Displays - Basic: VLL, VLN, A (Avg. & Phase wise), F; Power: W, PF, VA
PROCESS INTEGRATION:
(Avg. & Phase wise); Energy: Wh or VAh programmable (any one),
Integration of process
Load hrs, Max & Min ( VLL and Amps), OLD Wh, OLD LH.
parameters such as D
Front LED pulse 10000 imp/kWh of secondary input for EPM and
temperature, flow,
16000 for EPC.
pressure, RPM, etc. giving
Programmable PT, CT ratio upto 2000 MVA.
greater flexibility to
Energy is programmable to Wh or VAh with 6 Digits resolution and 4 A
monitor them along with
Digits resolution for instantaneous parameters.
electrical parameters.
80 to 300 V AC/DC Auxiliary supply.

Technical Specification:
Intelligent:
EPM 5110 EPC 5110
Clearance and Creepage distance meets safety standard. Accuracy: Class 1.0 (Default) as per IEC 62053-21,
Finger touch proof terminals to voltage and current connections. Class 0.5 as per IEC 62053-22 (Optional).
Parameter name and value displaying using 7 segment LED's. Sensing/ True RMS, 1 Sec. update time. 4 Quadrant Power &
Field programmable Star (Wye) or Delta or Single phase Measurement: Energy.
configuration. Input Voltage: 4 Voltage inputs (V1 V2 V3 VN). Programmable 110 or
415V LL Nominal (Range 50 to 550V LL)
Primary programmable upto 999 kV.
Mechanical Specification: Burden: 0.2VA Max. per phase.
Input Frequency: 45 - 65 Hz
67
72
Input Current: Current inputs (A1 A2 A3) 50mA – 6A
67 36 (Field configurable 1A or 5A).
Primary programmable upto 99 kA.
Overload: 10A max. continuous, 50A max. for 3 sec.
90 90 Burden: 0.2VA Max. per phase.
45 Aux-Supply 80 – 300V AC/DC, 40-70Hz.
45 (control power): Burden: 5VA Max.
Display resolution: 4 Digits for Instantaneous, Integrated: 6 Digits.
49 49
CT Ratio: 2000 MVA programmable.
+2
90-0 Optional 3DI, 2AI 6DI, 2AI, 2DO or 8DI, 2AI
55
90 IO (Lx0800)
Communication Parity: Odd, Even, None (Preferred Even)
96 +2
RS485 interface: Baud rate: 4800 bps to 38400 bps. (Preferred 9600 bps).
90
-0

96 90
Isolation: 2000 volts AC isolation for 1 minute between
communication and other circuits.
Zigbee: Optional Optional
Mounting: Panel DIN rail
Weight: Unpacked 300 gms. Packed 400 gms
Torque 1 N-m
Wire gauge 11 AWG

12 elmeasure.com
MPS

MOTOR PROTECTION
SYSTEM
Voltage | Overload | Frequency | PF | Single phasing | Unbalance
loading of voltage and current | Neutral current | Phase reversal.

ONE STOP SOLUTION FOR MOTOR PROTECTION!

Features : Additional Features for MPS 8000:


User programmable password protection. Displays ON hours , Load hours & number of interruption.
Auto-scaling of Kilo, Mega, Giga and decimal point. Simultaneous display of 7 parameters.
Auto scrolling. Intelligent power save mode.
Finger touch proof terminals for voltage and current connections. Two field configurable parameter for continuous display.
Clearance & creepage distance meets UL 61010 safety standard. Continuous Wh display even in Auto-scrolling mode.
Communication with PCs, PLCs, DCS through optional RS 485/232 serial Graphical display.
interface. Neutral current display and protection.
Potential free output with programmable trip time for protection. Single solutions for protection of motors/equipment against voltage, overload,
Displays more than 25 parameters Basic (VLL, VLN, A, Hz); Power (W, VA, frequency, PF, single phasing, unbalance loading of voltage and current, neutral
PF) and Energy (kWh, Load Hours). current, & phase reversal.
Displays the reasons for tripping for future correction. Programmable (intelligent inverse time) trip time for
Programmable start time from sensing safe condition. Volts/Overload/Hz/PF/Neutral current.
Programmable locked rotor current and time. Programmable relay status High or Low for safe; 2 relays for alarm and trip.
Detect winding shorts.
Safe/Alarm/Trip indication for online view.
Manual re-correction after the trip.
Operational diagram

MPS 8000 Intelligent tripping based on load


Technical Specification:
Amps, Frequency, PF, Unbalance

Neutral current, Single phasing


Parameter like under/over Volts,

Programmable Relay Status


Specification Description
loading of Voltage/Current,

Off time

Accuracy: Class 1.0 (default) as per IEC 62053-21, Class 0.5 as per
Programmable

OFF TIME
Variable
IEC 62053-22 (Optional).
Start Delay

Sensing/ True RMS, 1 Sec update time.


Load Pattern
Alarm Relay
for Warning

UNSAFE REGION
Measurement:
Input Voltage: 4 Voltage inputs (V1 V2 V3 VN); Programmable 110 or
SAFE REGION
TRIP TRIP 415V LL Nominal (Range 80-550V LL) Primary
Time Programmable up to 999 kV
Burden: 0.2VA Max. per phase.
Input Frequency: 45 - 65 Hz

Mechanical Specification: Input Current: Current inputs (A1 A2 A3) 50mA - 6A


(Field configurable 1A or 5A) Primary Programmable
up to 99 kA Overload: 10A max continuous,
50A max for 3 sec. Burden: 0.2VA Max. per phase.
90-0+2 Aux-Supply: (Control Power): 80 - 300V AC/DC.
55
90
Communication Parity: Odd, Even, None (Preferred Even)
RS485 interface: Baud rate: 4800 bps to 19200 bps. (Preferred 9600 bps).
Isolation: 2000 volts AC isolation for 1 minute between
96 90-0
+2

communication and other circuits.


96 90
Weight: Unpacked: 300 gms, Packed: 400 gms

elmeasure.com 13
EN | PN

DEMAND CONTROLLER
Multifunction Meter | Demand Controller | Import Export | Harmonics |
Power Quality | Digital/Analog Input or Output | Dual Source
E PRG E
PRG
B B CLR P
CLR P

HIGH-END MULTIFUNCTION METER FOR


COMPREHENSIVE ENERGY MANAGEMENT!

Features : Optional Features EN :


High / Low recording VLL, VLN, A, Hz, W, VA, PF, VAR value storage with Digital outputs - 4 potential free contacts with programmable time delay.
time stamp. Hysteresis of 1%. Trip time delay: 1 to 180 sec.
Accuracy class 1.0 as per IEC 62053-21, Class 0.2s, 0.5s optional. Output configurable to any of the parameters from VLL, A, F, W, PF, VA
User programmable Password Protection. TOD option ( Energy & Demand upto 8 slots ).
Measures THD and Individual harmonics up to 63rd order with a Analog Input upto 2. Accuracy of class 1% FS.
sampling rate of 512 samples / cycle. Digital Input upto 4
Captures and measures power quality events: K factor, Crest factor, Analog Output - Two independently programmable to 0-20 mA (or) 4-20 mA
Sag / Swell, Interruption and Unbalance in accordance with EN 50160. Individual Harmonics upto 63rd order.
Demand Controller with 4 Relay outputs.
Display basic, power, energy, demand for both import and export
parameters. RTC synchronisation through communication.
Upto 60A or 100A direct measurements using Hanging CT.
Representation of waveforms for instantaneous V, I, Sag / Swell.
voltage and current harmonics histogram. Datalogger - 6MB optional / Ethernet with 14GB memory for IOT device.
Dual Source
Records events such as Sag / Swell for voltage with the time stamp in
1s duration.
CO2, ON Hr, Power Interruptions.
Max demand 4 high / 4 low, Flash 6MB, 12am snapshot, 31st day
snapshot. Typical Applications
Simultaneous sampling of voltage and current, programmable
PT & CT ratio. Automatic connection or disconnection of DG connected to common bus .
Keep equipment in safe region.
Demand update every second to forecast kVA, kW & kVAR accurately.
Protection of equipment from Under/ Over Voltage or Current or Frequency.
Clearance and Creepage distance meets UL- 61010. Process control.
Programmable starting current in % of 5A secondary. Default 10mA Protection of 3 phase equipment from Single phase prevention, Overload etc.
Programmable Auto scrolling time - 1 sec. to 10 sec. (Default 5 sec.).
Programmable Energy display - Counter based or Resolution based.
Energy resetting at 9999999 kVAh x MF.
Multiplication factor for counter based energy mode
Front LED pulse 16000 imp/kWh.
OLD register to store previously cleared Energy & Load hours. Full Scale in Watts : 0.4k 4.01k 40.1k 400.1k 4M 40 M 400M
3 × VPri x Apri /1000 to to to to to to to
Phase wise Voltage Sag & Swell Wave Forms.
4.0k 40k 400k 4000k 40 M 400 M 4000M
LCD 8 parameter display at a time, 8 Digits energy.
Power save mode with Enable/Disable option. Multiplication Factor: 0.01 0.1 1.0 10 100 1000 10000
Available RS485 communication & optional Ethernet communication Unit of display kWh MWh GWh
(factory configurable).
Byte order option - Field Programmable Float / Little Endian / Big Endian
data format.

Mechanical Specification:

90-0+2
96
90

46

90-0+2

90
96

57

14 elmeasure.com
Product Selection EN 8400 EN 8420 PN 8710 PN 8740
ACCURACY OPTION Customised LED Graphical LCD
CLASS 1.0
CLASS 0.5S
CLASS 0.2S
BASIC PARAMETERS
V12 V23 V31
V V1 V2 V3
A A1 A2 A3
Hz
Angle V/A RPM
POWER PARAMETERS
Unbalance V & A
W W1 W2 W3
VA VA1 VA2 VA3
PF PF1 PF2 PF3
VAR VAR1 VAR2 VAR3 - Ind
VAR VAR1 VAR2 VAR3 - Cap
POWER QUALITY PARAMETERS
THD - V A Power upto 63rd
Ind. Harmonics upto 63rd * *
K Factor
Crest Factor
High Low
Sag & Swell
ON Hr
Power Interruptions
CO2
% Load
TEHD * *
TOHD * *
INTEGRATED PARAMETERS
Wh
VAh
VARh-Ind
VARh-Cap
Load Hrs.
RD (IE)
Kwh Total * *
KVAh Total * *
KVARh Total * *
OLD Energy
OLD Load Hrs.
OLD RD Details
Volt Squared Hours * *
Amp Squared Hours * *
TOD PARAMETERS
TOD Demand
TOD Energy
TOD RD (IE)
DEMAND PARAMETERS
Sliding Demand
Block Demand
Rising Demand
Forecast Demand
Step Demand
Maximum Demand
Maximum Demand 4 high / 4 low
Cumulative MD Option
Additional Load
12am & 31st day snapshot
6 MB Data Logging
DUAL SOURCE
Dual Source
ADDITIONAL OPTIONAL FEATURES (ANY ONE)
Ethernet +14 GB Data Logging
2DI
4 DI (WAGES)
1DO
2DO
2AI
1AO
2AO
2AI, 2DO
2DO, 2AO
4DO
Optional feature * Only through communication

elmeasure.com 15
Technical Specification:
EN 8400 EN 8420 PN 8710 PN 8740
GENERAL CHARACTERISTICS
Sensing / Measurement True RMS, 1 Sec update time, 4 Quadrant Power & Energy
Rated voltage 50-600 VLL
Rated current 10mA - 6A
Frequency 45 - 65Hz
Poles description 1P + N, 3P, 3P + N
Sampling rate 512 bits / cycle
Measured Accuracy Class Class 1 as per IEC 62053-21 / Class 0.5 / Class 0.2S as per IEC 62053-22 (Optional).
Display type LED 3 row LCD 8 row
Instantaneous Digits 4 4
Integrated Digits 8 7
Programmable Setting 110 or 415V LL Nominal & Primary Programmable up to 999 kV. Burden: 0.2VA Max. per phase
Permissible overload 120%, Burden: 0.2VA per phase
External Fuse Rating 200mA
CT PT Ratio Max 2000MVA Programmable
Auxiliary supply 80-300V AC / DC
Power consumption 4VA nominal. 5VA for DMC
Data update rate 1 Sec.

COMMUNICATION
Device ID & Parity 1 to 247 & Odd, Even, None (Preferred Even)
Protocol & Interface Modbus. RTU & RS 485
Baud rate 9600 bps to 115200 bps (Preferred 9600 bps)
Isolation 2000 volts AC isolation for 1 minute between communication & other circuits

ENVIRONMENTAL CHARACTERISTICS
Operating temperature -10°C to + 55°C (14°F - 131°F)
Storage temperature -25°C to +70°C (-13°F - 158°F)
Humidity 5% to 95% non-condensing
Altitude Below 2000mts
Measurement Category CAT III
Pollution degree 2 (As per IEC 61010)

PROTECTION CLASS
Ingress protection IP 51 ( IP 54 front facia optional ) & Double Insulation ( As per IEC 61010-1)

ELECTROMAGNETIC COMPATIBILITY
Electrostatic discharge IEC 61000-4-2g
Immunity to Electromagnetic IEC 61000-4-3g
RF Fields
Conducted Immunity IEC 61000-4-6g
Immunity to Magnetic Fields IEC 61000-4-8g
Immunity to voltage dips and IEC 61000-4-11g
interruptions
Fast transient IEC 61000-4-4g
Immunity to surge waves IEC 61000-4-5g
Impulse voltage CISPR- 22
Conducted and radiated emissions

SAFETY AND STANDARDS


Construction IEC/EN 61010-1 ed.3, CAT III, 300 V LN / 600 V LL , Protection class II.
Standards UL 61010-1, IEC/EN 62052-11

MECHANICAL CHARACTERISTICS
Weight Unpacked 350 gms. Packed 450 gms. (It may vary based on optional features)
Dimensions 96x96 mm
Torque 1 N-m (For 5A)
Wire gauge 11 AWG (For 5A)

16 elmeasure.com
IM

POWER QUALITY METER


Multifunction Meter | Demand Controller | Load Manager | Import Export |
Harmonics | Power Quality | Digital/Analog Input or Output

HIGH-END MULTIFUNCTION METER FOR


COMPREHENSIVE ENERGY MANAGEMENT!

iM8000 is an ideal choice for remote monitoring of devices via


M2M software platform. The performance and availability of Features :
devices can be monitored using inbuilt MQTT as well as TCP/IP
Displays all the electrical parameters & waveforms on Webpage and TFT
protocol. Also, iM8000 can provide comprehensive information Display.
on all power quality issues.
100% LIFO data recovery.

Gateway IP, user name & password can be changed to default IP


(192.168.5.175), username (elmeasure) & password (elmeasure) from holding
Unique Features : hardware reset key for 10 seconds.

Real time SD card status & memory space indication


Sag & Swell with timestamp & 10 waveform storage.
One touch recovery
Real-time THD & Individual harmonics (upto 63rd harmonics) with
value & graph in the display & web browser. LED Indication for easy setup & trouble shooting
Data storage upto 14GB. Web browser for debug, configuration, setup & information on Device brief
Real-time FFT waveform for individual phase both current & voltage description.
in the web browser. Configurable account based secure access - required login name & password
Integrated web server for configuration & data. for login
Demand parameters (W, VA, VAR,) with Date & timestamp for Online setting changes (reboot is not required)
Maximum Demand.
Mobile data service network signal strength
TOD option for Energy & Demand upto 8 slots.
Color code indication for device & network connection
Graphical Energy Report - Hourly, Daily & Monthly.
Direct cloud connectivity - Ethernet. Gateway statistic for remote diagnosis & troubleshooting

Data push in 5 sec. (ETH). Online debug status


Diagnostic page. Built in RTC with configurable option
Phasor diagram for voltage & current. DHCP (obtain an IP address automatically) or Static IP
Pictorial representation of all 3 Phases simultaneous
Configurable broker IP Address, port number, Quality of services
(Voltage & Current) in terms of sinusoidal waveforms.
High-resolution display with capacitive touch. Easy switch of Ethernet communication interface

Individual phase energy for import & export with 1-second update. Secured Data transfer over MQTT with user authentication for connection &
High / Low recording VLL, VLN, A, Hz, W, VA, PF, VAR value storage data transfer
with time stamp. Multi-client Connection
Real-time waveform for all the voltage & current can be displayed No Gateway ID conflict in wildcard topic enable
simultaneously on meter & web browser
Full device parameter logging.

Transaction ID based data logging, publish & recovery.

Transaction ID based message acknowledgement & auto retry/ recovery


Mechanical Specification:
Options to disable live, log & recovery.

Suitable for EMS application & Monitors all electrical data.

90 +2
-0
Configurable UART Baud rate, all meter configurations through Webpage.
96
90 Electrically isolated communication ports.

46

90-0+2 Multiplication factor for counter based energy mode


Full Scale in Watts : 0.4k 4.01k 40.1k 400.1k 4M 40 M 400M
90 to to to to to to to
96 3 × VPri x Apri /1000
4.0k 40k 400k 4000k 40 M 400 M 4000M

Multiplication Factor: 0.01 0.1 1.0 10 100 1000 10000

Unit of display kWh MWh GWh


57

elmeasure.com 17
WORKING PRINCIPLE
LGRS

ETHERNET

RS485

MODBUS/MQTT

SD CARD

COMMUNICATION
IM 8000

INTERNET
MQTT BROKER
LAN ROUTER

SOFTWARE SCREENS Technical Specification:


Specification Description
Accuracy: Class 1 (Default) IEC 62053-21,
Class 0.5S IEC 62053-22 (Option)
Sensing/ True RMS, 1 Sec update time, 4 Quadrant
Measurement: Power & Energy.
Input Voltage: 4 Voltage inputs (V1, V2, V3, VN); Programmable
110 or415V LL Nominal (Range 50 – 550V LL); Primary
programmable up to 999 kV.
Burden: 0.2VA Max.per phase
Input Current: Current inputs (A1, A2, A3) 50mA - 6A
(Field configurable 1A or 5A).
Primary programmable up to 99kA.
Overload: 10A max continuous, 50A max for 3s
Burden: 0.2VA Max, per phase.
Aux-Supply 80 – 300V AC / DC
(control power): Burden: 5VA Max
Display type: Touch Screen

Communication Parity: Odd, Even, None (Preferred Even)


RS485 interface: Baud rate: 9600 bps to 115200 bps. (Preferred 9600 bps).
Isolation: 2000 volts AC isolation for 1 minute between
communication and other circuits.
Weight: Unpacked: 400gms, Packed: 500gms
Torque 1 N-m
Wire gauge 11 AWG

18 elmeasure.com
SMART
RESOURCES
A VERSATILE COST EFFECTIVE
SOLUTION TO MONITOR, CONTROL
& CONFIGURE
AT SITE

Energy management
Smart resources helps in improving Smart Analyzer
reliability and accuracy by providing Allows versatile measurements and analysis of
consumers better ways to manage energy Power quality events such as Swell, Dip, Interruption,
usage and costs transients, and harmonics

Data Acquisition
Real-time data Automatic Transfer Switches
recording, data Smartest approach to provide
logging and uninterrupted power for critical
analysis can be applications by transferring
used to anticipate sources between the load with
breakdowns, accurate measurement of voltage
reduce downtime, current energy for better
lower service and protection
maintenance costs.

Simple and cost effective smart resources from ELMEASURE® can be used to perform periodic assessments, store data, measure energy
and to perform detailed analysis to improve their quality and reliability. Typical applications of these devices can be seen in apartments,
villas, commercial buildings, medical facilities, automation industries.
PE
IS 15884
AC STATIC
IS 13779
WATTHOUR METER
Multifunction | Dual source | Over voltage/current cut off for protection

SINGLE DEVICE FOR ELECTRICITY, GAS & WATER


MEASUREMENT!

Software Features :
TechnicalSpecification:
Technical Specifica on:
Monthly fixed charges based on kVA/kW. Specification Description
Accuracy Class 1.0 (default) as per IS 13779/15884,
Maintenance charges based on area or fixed.
Class 0.5 as per IS14697 (Optional).
Advance information about tripping with 2 Alert SMS/Email for the
Sensing/ True RMS, 1 Sec update time. 2 Quadrant Power & Energy.
different balance amount.
Measurement
Holiday cut off prevention. Input voltage 4 Voltage inputs (V1, V2, V3, VN) Programmable 110 or
Night time cutoff prevention. 415V LL Nominal (Range 80 to 550V LL).
Primary programmable up to 999kV. Burden: 10VA Max.
SMS / Email will be sent stating negative threshold.
Input Frequency: 45 - 65Hz
EB/DG Grace threshold setting.
Input current Current inputs (A1, A2, A3) whole current 10/60A or
kW/kWh logging every 15 minutes for future clarification, Profiling. CT operated 5A.
Overload: 3 times for 3s.
Intimation on ELNet whether it is working on EB or DG to prevent
Burden: 0.5VA Max. per phase.
misuse.
Whole current 5/30A or 10/60A or 20/80A
ELNet displays EB/DG kWh, kW and Balance. CT Operated ___ /5A
Wrong Recharge reversal entry. CT PT Ratio Max 2000 MVA Programmable for CT operated.
Online Customer Login Portal- User can get balance credit through any Display Resolution 1 row, 6 Digits, (Integrated 6 Digits) 10mm.
of the interface (Mobile / web-portal) or through Apps. Communication RS485, Ethernet, GPRS, RF & Wifi.
Service provider name logo, Grievance forum. Gas / water Factory configurable Digital input with Maximum
input option Frequency 3 Hz for upto 4 channel.
Information through Smart mobile app where in no need of remote
display. Weight 3 phase: Unpacked - 1650 gms, Packed - 1850 gms
Single phase: Unpacked - 670 gms, Packed - 750 gms
Torque 2 N-m
Wire gauge 6 AWG

Mechanical Specification:

69mm 171mm
75mm 168mm
148mm

58mm
112mm
270 mm
158 mm

158 mm

263 mm

263 mm

244 mm

270 mm

244 mm

Single phase: Dimension Bezel: Three phase: Dimension Bezel: Three phase: Dimension Bezel:
158 x 112 mm (Depth 58mm) 263 x 168 mm (Depth 75mm) 270 x 171 mm (Depth 69mm)

20 elmeasure.com
PREPAID METER WITH RF

2
From Database to
MQTT GW EL-CONFIG
Services will be used
MQTT GATEWAY

DATA BASE WEB SERVER

3 1

From MQTT GW From Mobile APP


to Meters ELNet-MS to Database
& ELNet-DS Services WEB Services
will be used will be used

RF ID
ElConfig

IP Address : Port

User Name

*******
Remember me

Sign in
GW 2020

2018 - Elmeasure India Pvt. Ltd.

GW2020 POWER ASSISTOR GATEWAY ELCONFIG APP

GW2020 will broadcast the Power Assistor Gateway will broadcast


4 EB-DG Status to the meters
5 the EB-DG Status to the GW2010

Features : Additional Features


QR Code scanning for auto configuration Gateway for interfacing with Ability to pay-as-you-go.
cloud network by using MQTT lite protocol.
Explicit view of energy usage & tariff rates.
Occurrence with Date & Time.
Alarm notifications for low credit balance.
Restoration with Date & Time.
Anti-tamper Features provided in the meter as per Indian standards.
RF Communication for meter data reading.
Reduces manual supervision.
Acknowledge will be given in the meter by pressing right key
Live updates on energy consumption at your fingertips.
continuously for 10sec and alarm will stop permanently till next low
balance. Keep records of recharge & consumption history.

Mobile application for Pre Paid Software (PPS).

Applications :
Prepaid metering solution will provide flexibility for consumers to pay
for electricity from any location without any hurdles, no more standing
in queues, the hassle of bills & receive better customer service.

Shopping Malls & Commercial Complexes.

Gated residential societies /Residential apartments.

Industries & Government Sectors.

elmeasure.com 21
WIRELESS DG SENSOR

Grid Power Source 2 Power

R AMF PANEL R From DG


Y Y
B Potential free B (OR)
N contact N B CLR P
PRG E

R Y B N A
A

DUAL SOURCE POWER ASSIST

M1
GATEWAY
M2 N

SMART WATT HOUR METER


Three phase & Single phase.
Compact wall mounting design.
Electrical load management, water & gas
consumption.
Postpaid or Prepaid.
Dual Source or Intelligent Detection mode.
Direct current 5/30A, 10/60A with ISI
certification.
20/80A & CT operated 5A.
No separate EB & DG recharging.
Protects household equipments against
overload or overvoltage.
Communication options: RS485, Ethernet,
GPRS, RF & Wifi.

Remote Water Gas

REMOTE UNIT
Allowing customer to monitor consumption.
Elegant design & no separate power is required.
Display all parameters including balance.
Display blinks & buzzer beeps in frequent
interval to indicate low balance.

22
3:37

ELNet PPS

Recharge Monthly- Update Your


History Year Trend Profile

Customer
Complaints Power ON Power OFF

GRID 03-Nov 2017


Supply Expected Recharge Date

Live Update

CUSTOMER WEB PORTAL | MOBILE APP


Online Customer login portal/ Mobile app login.
User can get balance credit through any of the interface
(Mobile/Web-portal) or through Apps.
Remote switch ON/OFF through mobile app
Information through Smart mobile app - no need of
Remote display

ALERTS OVER EMAIL/SMS


Warning SMS at 20% and 10% of kWh threshold level,
step tariff crossover.
Sending SMS to the users during power outage:
Get alerts for activities like Account recharge, Recharge status,
Low Credits, Overload, Overvoltage, etc.

ENERGY BILLS, CONSUMPTION & PRICING


Real time data monitoring.
Recharge Slip, Recharge history for the selected
date range
Monthly billing with breakup of EB/DG
energy bills and Maintenance bills.
Running Hours of DG and Mains Supply is
provided.
Cheque reconciliation.

RF CARD

ONE TOUCH AUTO CONFIGURATION

RECHARGING OPTIONS

ONLINE PAYMENT
PAYTM, CREDIT CARD,
DEBIT CARD

23
iACCL

AUTOMATIC CHANGEOVER
WITH CURRENT LIMITER
FOR A SEAMLESS, UNINTERRUPTED CHANGEOVER
BETWEEN POWER SOURCES!

Features : Mechanical Specification :

Single Phase

Dimension Bezel: 90 x 72 mm Dimension Bezel: 96 x 96 mm

90 mm

96mm
72mm 67mm

(For EB in iACCL 600).

Three Phase

144 mm
/ 124 mm 7.5 mm

15 mm

/
iACCL M 300

144 mm 127 mm
105 mm

DG Phase selec on - Programmable


15 mm

EB single phase missing programmable for Y and B phase 124 mm


1 mm

40A to 63A

Unique Features :

218mm
195mm

163mm

Inbuilt display and measurement of A, V, F & kWh on the


generator side and mains side for iACCL M600
305. mm

310. mm
285mm
310mm

265mm
183. mm

186. mm
198mm

(180 - 260) rAC 10mm


5 mm

operations. 10 mm
238mm
5mm

(Op onal)

iACCl M100 Single Phase.

*Note: iACCL M600 comes with Prepaid optional features

24 elmeasure.com
Datasheet iACCL M600
iACCL M600
iACCL M600

M400 M100 M300 M300 M300 M600 M600 M600


ELECTRICAL CHARACTERISTICS
Rated Current 25/32A 25/32A 40-63A 80A 100-125A 40-63A 80A 100-125A
No. of Poles 1P+N 1P+N+1 3P+N
Power Load

Rated Operating Voltage 240VAC 415/240VAC


Rated Frequency 50Hz
Time Duration Transfer: 5-30s Programmable, Restore : 5s
Utilization Category AC3 AC1 (Tripping based on AC3)
Ingress Protection: IP 20 & Double Insulation ( As per IEC 61010-1)
Duty Uninterrupted
Cycle time 6 Sec to 150 Sec, No. of Cycles 5 to 10 (default 5 Cycles)
Accuracy Class 1
PROGRAMMING FEATURES
Baud rate
Parity
Device id
Password
Energy Selection
DG under voltage
Parameters DG over voltage
DG Maximum Current Limit
EB Maximum Current Limit EB Maximum Current Limit
DG Start time
Cycle time
No. of Cycles 1 to 10
DG Output selection EB and DG Output selection
METERING PARAMETERS
EB Source Current, Voltage, (PF, W, Wh optional)
DG Source Current, Voltage, PF, W, Wh
COMMUNICATION
Device ID & Parity 1 to 247 & Odd, Even, None (Prefered Even)
Protocol & Interface Modbus. RTU & RS 485
Baud rate 4800 bps to 19200 bps (Preferred 9600 bps)
Isolation 2000 volts AC isolation for 1 minute between communication & other circuits
DISPLAY
Display type LED 1 row
Instantaneous Digits 4
Integrated Digits 4 4 6
FAULT TRIPPING
EB Source Over Voltage Over Current, Under / Over Voltage
Phase Missing
DG Source Under / Over Voltage, Over Current
NA Phase Missing
MECHANICAL CHARACTERISTICS
Mounting (Vertical) Din Rail Surface Mounting Surface Mounting
Outline Dimension
90X72X67 90X90X75 144X144 182X217 265X210 144X144 182X217 265X210
(M400 R) (M 100 R) X120 mm X145 mm X166 mm X120 mm X145 mm X166 mm

Weight in kg 280 grams 350 grams 2.1 kg 4.5 kg 7 kg 2.1 kg 4.5 kg 7 kg

Torque 1 N-m 1 N-m 2 N-m 2 N-m 2.5 N-m 2 N-m 2 N-m 2.5 N-m

Wire gauge 11 AWG 11 AWG 6 AWG 4 AWG 1 AWG 6 AWG 4 AWG 1 AWG
STANDARDS
Compliance IEC 60947-6-1
USE ENVIRONMENT CHARACTERISTICS
Temperature Ambient: -5 to +550 C, Storage: -25 to +750 C, Operating: -10 to +550 C, Operating Humidity: 5 to 85% RH
Environmental Class B
Pollution degree 2

elmeasure.com 25
iD-LOG

PORTABLE POWER
QUALITY ANALYZER
3 Phase and Unbalanced Load | Harmonics

HAND HELD PORTABLE POWER ANALYZER WITH HIGHER


ACCURACY AND DATA LOGGING!

Features : Benefits :
Ability to connect and analyse various types of electrical
systems Equipped with a large graphical LCD with high efficiency, which allows the
Single Phase visualization of waveforms, graphics, etc.. and the use of multilingual menu
Unbalanced phase with or without neutral. (English, Italian, Spanish, Germany & French). The white pixels on indigo

Full traditional energy analysis ( V, I, P, Q, S, F, PF, THD%, actual values provide exceptional visibility of the display.
/ Minimum / Maximum / Average, energy meters and consumption An elegant keyboard with 10-key dual function allows the user an easy and
generated for each phase and single phase. intuitive navigation menu.
Analysis of power quality parameters The instrument can be indifferently grasped through its ergonomic rubber,
Harmonics of current and voltage for each phase and for the or else placed on a plane thanks to an integrated removable support, both
neutral. to simplify the measurement operations on field or to use near a PC.
Phase unbalance voltage. The availability of a microSD memory card for storing data and USB port for
Net interruption , overvoltage, sags. communication with PC, allows the creation of accurate measurement
Test according to EN 50160. campaigns and the subsequent analysis of the data using the dedicated
software supplied.
A further innovation is the equipment of mini flexible current probes. This
Advance Features : feature significantly improves the portability and handling of the
instrument, reducing weight and size, without impairing the possibility of
Real measurement of the neutral current.
measurement.
Display waveforms of currents and voltage.
Setting four tariff bands with display of relative costs.
Configuration and display of alarms and threshold on selectable
measurement. iD-LOG MAKES IT POSSIBLE
Visualization of the time course of selectable parameter (trend)
Checking of the correct connection of the instrument to the system.
Possibility to measure long-term campaigns.
Choice of language.
Customizable display, choosing which parameter to view according to
a rotation in the lower part and turning it 90o in relation to the
convenience of reading.

damage.

26 elmeasure.com
Functions :
Mechanical Measure
Type Handheld Traditional energy analysis Y
Dimension 203 x 116 x 53 mm. (V, I, P, Q, S, F, PF, THD, coso , peak,
Weight 600 g minimum, max, medium, max,
Protection IP30 demand, etc.
Container material ABS V0 e EPDM Three Phase counter Y
Counter for each phase Y
ELECTRICAL Cogeneration Y
Single Phase Y Waveform Y
Three Phase Y Harmonics Up to 50th order
Input Voltage 4 (3 + N common + AUX) Histogram Harmonics Y
Input Current 6 - 3000A Dips >500ms
Safety 5 independent Swells >500ms
Interruptions >500ms
POWER SUPPLY
Battery Package 4 x AA 2100mAh Fast Transient Y
Trend Y
Supplier/battery charger.ext. 100-240V AC /50-60Hz
Unbalance Voltage Y
Autonomy Charge >24h
Test EN 50160 Y
USER INTERFACE Neutral Current Y
Type FSTN Graphic LCD Inrush Current Y
Dimension 68 x 68 mm. DC Measure Y
LCD Definition 128 x 128 Alarms Y
th
Color White Pixel / Indigo Background K Factor Y (Up to 25 order)
Back light Solar Radiation Y
Menu Multilingual Temperature photovoltaic panel N
Keyboard 10 membrane keys Environmental temperature N
Languages English/Spanish/Italian/German/French Voltage 1000V AC (P-N); 700V AC (P-P);
ANALYZED SYSTEMS 1000V DC
Single Phase Y Current Up to 3000A (with MiniFlex Sensor)
Two Phase Y Frequency 50Hz - 60Hz - 400Hz
3 Phase + N, Balanced Y Tariffs Band Y
3 Phase + N, Unbalanced Y Energy costs Y
3 Phase Without neutral, Balanced Y Voltage ±0.25% +0.05 F.S.
3 Phase w/o neutral, Unbalanced Y Precision Current ±0.25% +0.05 F.S. ± Σ CT
Photovolt @ 1 Phase Inverter N Power ±0.5% +0.05 F.S.
Measurement camping Y
COMMUNICATION Y
Alarm Log
USB To PC Test Voltage N
Wireless (ZigBee) Y
DATA RECORDING ENVIRONMENT
Internal memory 64kB
Functional tempreture -10 to +55 °C
External memory Micro SD
Storage temperature -20 to +85 °C
Max. Humidity 95% (No Condensation)
KIT COMPOSITION
Mini flexible clamp 3 ACCESSORIES
Voltage cable 4 CLAMP 1000A/1V Y
Crocodiles 4 CLAMP 200A/1V Y
Voltmetric tip N CLAMP A/1V Y
Cable/miniUSB_B Y FLEXIBLE CLAMP 1000A Ø40 Y
External power supply Y FLEXIBLE CLAMP 3000A Ø80 (NEW) Y
CD software Y CLAMP 400 IN DC Y
MicroSD card 4 GB CLAMP 1000A IN DC Y
Hard Case Y Set auxiliary voltage cable Y
Soft Bag N Set 4 voltage cable Ø4 Y
Solar meter N Hard Case Y
Temperature probe N Battery package NiMh Y
DC clamp N

REFERENCE STANDARDS
EN 61010-1 Y
EN 61326 / A1/A2/A3 Y
EN 50160 Y
CEI 82-25 N
EN 60904-3 N

elmeasure.com 27
iD-LOG

PORTABLE POWER
ANALYZER / DATA LOGGER
USER FRIENDLY | DYNAMIC COMMUNICATION | DEMAND MONITORING

HIGH PROFILE PORTABLE POWER ANALYZER WITH


HIGHER ACCURACY AND DATA LOGGING!

Features Parameters Technical Specification:


Basic
Line to Neutral Voltage V, V1, V2, V3 Specification Description
Line to Line Voltage V, V12, V23, V31 Accuracy: Class 1 (Default) IEC 62053-21,
Line Current A, A1, A2, A3 Class 0.2 with specific CT.
Neutral Current Computed AN
Frequency, RPM (Generator application) Hz, RPM Sensing/ True RMS, 1s update time, 4 Quadrant Power & Energy
V & A Phase Angle V1, V2, V3, A1, A2, A3 Measurement: 4 Voltage inputs ( V1, V2, V3, VN)
Unbalance V & A % V, % A, V1, V2, V3, A1, A2, A3 Input voltage: Programmable 110 or 415V LL Nominal (Range 80 to 520
Power VLL) Primary programmable up to 999kV.
Active Power W, W1, W2, W3 Burden: 0.2VA Max. per phase.
Apparent Power VA, VA1, VA2, VA3
Input frequency: 45Hz to 65Hz
Reactive Power VAR, VAR1, VAR2, VAR3
Power Factor PF, PF1, PF2, PF3 Input current: Current inputs up to 100mV or 100mA
Energy / Integrated Primary programmable up to 99kA.
Active Energy Wh Burden: 0.2VA Max. per phase.
Apparent Energy VAh Aux-Supply: Built-in
Reactive Energy VARh-Ind, VARh-Cap
Display Type: LCD graphical display.
Load Hrs, No. of Interruption, Life Timer LH, Intr, On.Hr Ah, PF Avg
Old (Energy, Load Hrs) Old (Wh, VAh, VARh Ind & Cap, LH) Display Resolution: 7 Digits.
Harmonics CT PT Ratio Max: 2000MVA Programmable.
Voltage THD THD% V1, V2, V3 Communication: GPRS / Ethernet
Current THD THD% A1, A2, A3
K Factor K Factor: V1, V2, V3, A1, A2, A3
Individual Harmonics Upto 31st (V & A)
Events (High/Low)/ With time stamp
Voltage VLL, VLN High/Low VLL, VLN CT Specification
Current High/Low A
Frequency High/Low Hz Suitable to measure current from mA to hundreds of kA.
VA High/Low VA High linearity | Wide range | Non-intrusive, no power drawn
W High/Low W from the main.
VAR High/Low VAR
Very useful with large size or awkward shaped conductors or in
Power Factor High/Low PF
Demand Programmable to any one of the below places with limited access.
Active Power (W) Watt No danger from open-circuited secondary | Not damaged by large
Apparent Power (VA)
Reactive Power (VAR)
Current Average (A.Avg)
VA
VAR
A Avg
} overloads.

Clip CT Rogowski coil Split Core

Rated Current: 100A ~ 10kA


Output: 0.333V or 100mV per 1000A
Diameter: 24 cm, 36 cm
Lead wire: 1.5 m length
Input current:
5, 50, 100, 200, 400 Isolation voltage: 3500V
Output: Temperature range: -25oC + 70oC Input Current: CT-100A | 400A | 1000A
20mA | 40mA | 66.6mA | 666mV Response bandwidth: 1Hz ~ 1MHz Output: 333mV | 666mV

*For complete specification refer page 34

28 elmeasure.com
iD LOGGER
Portable Power Analyser with Dynamic Communication, Higher Accuracy and Data Logging

Kit - 1 iD LOG - Ethernet


14 GB data logger (default)
Option for current measurement using
Clip CT (default) or Rogowski

Kit - 2 iD LOG - Ethernet & GPRS


14GB data logger (default)

Internet
Features
Helps you to locate, predict, prevent and troubleshoot problems in power
distribution.
Measures Voltage, Current, Frequency, Power, Energy consumption,
Unbalance, Harmonics and Inter-harmonics.
24x7 Cloud Server Data logging with Time stamp.
Monitor and Control large campuses or remote facilities with inexpensive web
technology.
Performs audits and analyses remotely.

Benefits
Maximum Return on Investments
Reduce Energy Costs
Improve Working Environment
Identification and elimination of energy waste
Security and System Integration
Various Protocol Supported
Economically priced
High Performance and Easy configuration

Applications Portability
Frontline troubleshooting Compact Size
Predictive maintenance Modular Construction
Quality of service compliance LCD Screen
Long-term analysis Inbuilt GPRS Communication
Load studies
Energy assessments

elmeasure.com 29
ElNet
Energy Management Software
The Software collects data from the plant consolidating it Web based technology
into manageable information to constantly monitor User friendly
energy usage and identify the core areas for corrective Enhanced security
Vector based graphics
action, ensuring optimum performance. Remote monitor and control equipment processes and
facilities with in-expensive web browsers
Report on operational status of equipment, process and
facilities
Reduce billing cycles by obtaining accounting
information directly from automation systems
Reduce service calls and manpower by using remote
diagnostics.
Use low cost secure connections to network over a
combination of Analyzing and Reporting ISP, Intranet,
24/7 CLOUD SERVER Internet and dial-up connections

Analyzing and Reporting


A variety of reports can be availed for the activity, schedule
and types by specific list:
Data Quality
Exception Reports
Alarm Handling Packages
Display Groups
Historical Data Trending
Real time Trending
Dashboard
Matrix

Reports can be viable and downloaded by any format


provided and schedules can be modified based on
convenient time. *Schedulers will automatically run
according to our initial configuration

Datalog Email/SMS
Trends - Single and Multiple days - Min, Max Day Log book, Hourly-day Energy, Shift Energy, TOD
& Avg. energy, Min max, Flexible energy report and for
Table view - Single and Multiple days - Data abnormal Alarm conditions
Export to Excel SMS to the mobile for the following: Abnormal Alarm
Alarm, Min & Max. conditions, Hourly and Daily Energy
Customization is possible for any kind of Email/SMS
options

30 elmeasure.com
SMART
NETWORKING
SMART DEVICE FOR FLEXIBLE NETWORK
AND COORDINATE
CONNECTIVITY

Remote Connectivity
Designed to facilitate secure, reliable
Compatibility
connectivity and quickly capture precise data Seamless integration with multiple
ideal for energy management system, building protocols/platforms and work as bridge between
management system and for any IOT solutions. Zigbee and GPRS for low cost installation.

Converter
User friendly, ideal Secured Communication
for connecting Compact and rugged device
serial RS485 that link non-internet sensor
devices to and devices to the internet so
notebooks or PC’s that data, configuration and
through an controlling can be made
available USB port. possible onlines expressed in
degrees with an

Smart networking devices are highly secure, rugged to simplify connecting,providing interoperability between networks and devices to
capture precise data for faster decisions and reduced network load. These devices are designed to provide reliable communications with
optional storage facility, built in RTC and one touch recovery for factory reset. Smart networking products are ideal for Energy Management
System, Building Management System and Data Centres, for controlling/diagnosing manufacturing machines such as CNC, Process Control
Equipment, Barcode Scanners, Serial Printer applications.
GW
GPRS

ETHERNET

RS485
GATEWAY
MODBUS/MQTT
RS485 | ETHERNET | GPRS | RF

A MACHINE COMMUNICATION UNICORN TAILOR MADE


FOR INDUSTRIAL IOT WORLD!

Features : Benefits:
Compact size.
Gateway helps link non-internet sensor and devices to the internet so that
Built in RTC. data, configuration and controlling can be made possible online.
Embedded web server for easy configuration and commissioning using Gateway can work as bridge between Zigbee and GPRS at low cost installation.
a web browser.
Modbus/MQTT protocol.
DHCP / Static IP support
Applications:
Configurable RS485 baud rate, party and stop bits.
Completely isolated in both RS485 and RJ45 Energy management system
Optional storage Available. Building management system
One touch recovery ( Factory reset configuration ) Data centers, etc.
LED indication for easy setup and trouble Shooting.

COMMUNICATION MODEL
Master Device Modbus/MQTT GATEWAY Slave Device

D1 D2 D10

E E PRG E
PRG PRG
B B B CLR P
CLR P CLR P

PLC
Smart Meters

D11
D12

iACCL
SCADA

D13

Ethernet/GPRS
ElNet

Branch Circuit Monitor

D14 D64

EMS

Energy & Process Controlling


Ethernet/GPRS

Upto 64 device

32 elmeasure.com
Technical Specification:
GW 1000 (Ethernet/GPRS) GW 2000 (Ethernet/GPRS)
PROTOCOL
Modbus RTU MQTT

ETHERNET PORT
Connecter 8-pin RJ-45 socket for Cat 5 UTP 8-pin RJ-45 socket for Cat 5 UTP
Physical & Data Link Layer IEEE 802.3i 10/100 BASE-T IEEE 802.3i 10/100 BASE-T
Isolation 1.5 kV galvanic 1.5 kV galvanic
Max. cable length 100 m (328 ft) 100 m (328 ft)
Protocols Modbus TCP Server/client, RTU Modebus RTU. TCP/IP, IPV4,MQTT,
Server/Client, HTTP. DHCP, UDP, HTTP, ARP, ICMP.
Concurrent connections 2Modbus/TCP slave, 8 HTTP web page Windows: Maximum 1023 client

GPRS INTERFACE
Anteena 5 dBi (Omni-Directional) 5 dBi (Omni-Directional)
Quadband (850/900/1800/1900 MHz) (850/900/1800/1900 MHz)
Connectivity Internal module and SIM card socket Internal module and SIM card socket
Compliant to GSM phase 2/2+ Class 4 (2 W @850/900 Mhz); Class 4 (2 W @850/900 Mhz);
Class 1 (1 W @ 1800/1900 Mhz) Class 1 (1 W @ 1800/1900 Mhz)
Code Schemes C2 1, 2, 3, 4 Code Schemes C2 1, 2, 3, 4

SERIAL PORT RS-485/RS-422 INTERFACE


Connector 5.08mm 2-pin 5.08mm 2-pin
Physical layer EIA-485-A, 2-wire EIA-485-A, 2-wire
Isolation 15KV 15KV
Speed 2400, 4800, 9600, 19200, 38400, 2400, 4800, 9600, 19200 bps
57600, 115200 bps
Max. number of nodes 64 64
Protocols Modbus RTU (master), Modbus TC Modbus RTU (master)
P/IP (master)
Serial Number Virtual Com / TCP Server / TCP TCP Server / Serial Tunnel
Client / Serial Tunnel

USER INTERFACE
LED Indicators Power (RED), Ethernet link (green) Power (RED), Ethernet link (green)
Monitoring & Configuration Web browser based Web browser based
High availability features Watchdog supervision, brown-out Support Watchdog, system never halt
detection

POWER SUPPLY
Connector 5.08mm 2-pin 5.08mm 2-pin
Voltage 4.5-6 V DC 4.5-6 V DC
Current 2A typical @ 5 V DC 2A typical @ 5 V DC
Intrinsic consumption 4W Eth/6W LGRS 4W Eth/6W LGRS

ELECTROMAGNETIC COMPATIBILITY
Emissions (radiated and conducted) AS/NXS CISPR 22/En 55022 ( Class A) AS/NXS CISPR 22/En 55022 ( Class A)
Immunity EN 55024 EN 55024
Electrostatic discharge EN 61000-4-2 EN 61000-4-2
Radiated RF EN 61000-4-3 EN 61000-4-3
Fast Transients EN 61000-4-4 EN 61000-4-4
Conducted RF EN 61000-4-6 EN 61000-4-6

ENCLOSURE
Material self-extinguishing PC/ABS blend self-extinguishing PC/ABS blend
(UL 94-V0) (UL 94-V0)
Mounting 35mm DIN rail (EN 60715) 35mm DIN rail (EN 60715)
Classification/Type rating IP 20/NEMA Type1 IP 20/NEMA Type1
Cooling Connection Connection

ENVIRONMENT
Operating Temperature 0 to 60o C / 32 to 140o F 0 to 60o C / 32 to 140o F
Storage Temperature -25 to 85o C / -13 to 185o F -25 to 85o C / -13 to 185o F
Humidity rating 10 to 95% relative humidity, non 10 to 95% relative humidity, non
condensing condensing
Operating Ambience Free from corrosive gas, minimal dust Free from corrosive gas, minimal dust

PHYSICAL
Dimension 36mm x 90mm x 67mm 36mm x 90mm x 67mm
Weight 100gms 100gms

elmeasure.com 33
ACCESSORIES
CT

CURRENT
TRANSFORMER
SPLIT CORE | CLIP ON

Features : Applications:
Energy Management, Data logging, Recording,
Nominal Rating ranges from 5A to 1500A
Power & Energy Monitoring, Cost allocation
Accuracy ±1% from 10% to 130% of full scale range
Frequency Range of 50 Hz to 400 Hz
Shrouded core blades for protection during installation
Technical Data Split Core :
Snap closing/opening feature
Meet CE & ETL C57.13 ELSC 0750 ELSC 1250 ELSC 2000
Electrical
Nominal Rating 5 - 150 Amps 10 - 600 Amps 600 - 1500 Amps
Technical Data Clip On :
Accuracy ±1% for 10% to 130% ±1% for 10% to 130% ±1% for 10% to 130%
CT 301 CT 302 CT 303 of full scale range of full scale range of full scale range

Electrical Phase Shift at Rated


o o o
current 50/60 Hz <2 <2 <2
Rated Primary
Frequency Range 50 Hz to 400 Hz 50 Hz to 400 Hz 50 Hz to 400 Hz
Current 60A 200A 120A
Useful Current 10% to 130% of 10% to 130% of 10% to 130% of
Saturation current 85A 250A >120
Range Rated Current Rated Current Rated Current
Rated Secondary 20mA 66.6mA 40mA Working Voltage Maximum 600 Vrms Maximum 600 Vrms Maximum 600 Vrms
current 666mV (Optional) 666mV (Optional) 666mV (Optional)
Accuracy 1% 2% 1% Output Signal at 666mV (Default) 666mV (Default) 666mV (Default)
rated current 1000mV (Optional) 1000mV (Optional) 1000mV (Optional)
Electrical Strength 3000VAC 1mA60s 3000VAC 1mA60s 3000VAC 1mA60s
White lead is positive White lead is positive White lead is positive
Load Resistance 20 Ω 20 Ω 20 Ω
Output Lead 2.5 m twisted pair 2.5 m twisted pair 2.5 m twisted pair
Operation Frequency 50/60Hz 50/60Hz 50/60Hz (22AWG, terminated (22AWG, terminated (22AWG, terminated
Internal Diameter 10mm 24mm 16mm with ferrules) with ferrules) with ferrules)

Mechanical Specification
Mechanical Specification
CT 301 Window size 1.9 cm (.75") 3.2 cm (1.25") 5.1 cm (2.0")

Dimensions 5.1 × 5.3 × 1.6 cm 8.3 × 8.6 × 2.5 cm 12.1 × 12.7 × 3.0 cm
(2.0 × 2.1 × 0.6") (3.3 × 3.4 × 1.0") (4.8 × 5.0 × 1.2")
o o o
Operating Temp -10 to 50 C -10 to 50 C -10 to 50 C
o o o
(14 to 120 F) (14 to 120 F) (14 to 120 F)
A B C D E F Weight 136 g (4.8 oz) 340 g (12 oz) 748 g (26 oz)
25max 27.5max 42.5max + 10
1500 - +1
6- + 0.5
10 -
*All dimensions in mm

E
CT 302

D B
A

A B C D E F G
+ 0.5 + 10 +1 C
24.3 - 46max 66max 22Max 34Max 1500 - 10-
*All dimensions in mm

CT 303
A 2.00 inch 3.25 inch 4.75 inch
B 2.10 inch 3.35 inch 5.00 inch
C 0.610 inch 1.00 inch 1.20 inch
D 0.75 inch 1.25 inch 2.00 inch

E 0.75 inch 1.25 inch 2.00 inch

A B C D E F
+ 0.5
16.0 - + 0.3
31.3 - + 0.5
43.5 - + 0.3
22.8- +10
1500 - +1
6-
*All dimensions in mm

34 elmeasure.com
Our Key Customers

BURJ KHALIFA

Indian Oil

Certification
CM

Intertek
4007051

Contact for certification details


Registered Office Sales Offices:
BENGALURU BENGALURU
PLOT NO.: 47-P, HARDWARE PARK, KIADB, #57, EBENEZER ENCLAVE, NORRIS ROAD, NEAR
HUVINAYAKANAHALLI, JALA HOBLI, YELAHANKA TALUK, NANJAPPA CIRCLE LANGFORD TOWN,
BENGALURU - 562 149. KARNATAKA INDIA BENGALURU - 560 025. KARANATAKA, INDIA
info@elmeasure.com
+91 639 1010 320
COIMBATORE
# 150, RA J ILLAM, NVM LAYOUT NEW SIDDHAPUDHUR
VIETNAM COIMBATORE - 641 019. TAMIL NADU, INDIA
ELMEASURE VIET NAM PRIVATE LIMITED
22/15 16 STREET, LONG BINH WARD, DICTRICT 9,
CHENNAI
HCMC,VN
# 945, GROUND FLOOR, MIG, FIRST MAIN ROAD, TNHB
info@elmeasure.vn
COLONY, VELACHERY,
+84 888 99 0880
CHENNAI – 600 042. TAMIL NADU, INDIA

Manufacturing Units SECUNDERABAD


# 51, 1ST FLOOR, CHANDRAGIRI COLONY, NEAR RTA,
UNIT I THRIMUGHERRY,
SECUNDERABAD - 500 015. TELANGANA, INDIA
PLOT NO.: 47-P, HARDWARE PARK, KIADB,
HUVINAYAKANAHALLI, JALA HOBLI, YELAHANKA TALUK,
BENGALURU - 562 149. KARNATAKA, INDIA
MUMBAI
# 101, MILLENIUM PLAZA BEHIND SAKINAKA
UNIT II TELEPHONE EXCHANGE, ANDHERI - KURLA ROAD
SAKINAKA, ANDHERI (EAST)
GOWTHAM GARDEN NO. 4, VEERAPANDI MUMBAI - 400 072. MAHARASTRA, INDIA
COIMBATORE - 641 019. TAMIL NADU, INDIA

UNIT III DELHI


#764, 4TH PHASE, 707, YELAHANKA NEW TOWN, # G-10, G-11, GROUND FLOOR, BAISOYA COMPLEX,
NAYABANS, SECTOR-15,
BENGALURU - 560 064. KARNATAKA, INDIA NOIDA – 201301. INDIA.

Help Line: SHARJAH OFFICE

support@elmeasure.com ELMEASURE MIDDLE EAST FZE,


#SHARJAH AIRPORT FREEZONE,
+91 639-1010-320 P.O BOX 122471, SHARJAH, UAE.

PBL/V4/0619

Vous aimerez peut-être aussi