Vous êtes sur la page 1sur 1

5 - 160 kVA*

Notes
^ Tolerances Apply, *With 0.845 Specific Gravity of diesel ( 5 % Tolerance )
Prime ra ng and Stand-by ra ng ¹ Engine capacity does ma er ²

** Efficiency of Alternator as per standards IS 4722 and IEC 34-1
These weight are for handling & transporta on only For Site Condi ons other than standard opera ng condi ons consult KOEL for available prime power. ‘Prime power’ is designed for Unlimited hours, as Engine capacity (cc) plays a vital role in Genset
* Silencer inside canopy and bolt-less canopy is available only up-to 62.5kVA compared to 'Emergency stand-by' designed for 200 performance. Higher engine capacity leads to a robust
42
hours in a year. Prime rated Gensets also permit 10% and stable Genset performance.
temporary overloading. Users need to carefully select
the Genset ra ng to meet their requirement. KOEL offers Prime power Higher engine capacity also enables the Genset to respond quickly &
as a standard offer. Contact KOEL for stand-by ra ngs. posi vely to sudden load addi ons.
Engine Canopy State of the art Genset Controller
 Industries most reliable  Silencer inside canopy
Best-in-class Fuel Efficiency KOEL iGreen Gensets put the command in your hands.
engines, proven over  Aesthe cally designed
KOEL iGreen Gensets offer a unique combina on Micro-processor based Genset controllers display
decades bolt-less canopy for enhanced
of CPCB norm compliance and enhanced fuel efficiency. a host of Genset parameters and put all controls at
 Low emission, high product life
Across the range, KOEL iGreen Gensets offer substan al your finger ps.
efficiency engines  Weather and sound resistant
savings in fuel cost. Monitoring Features: Phase Voltage, Phase Current, kVA, kW, kWh,
 Compact, robust and enclosure
rugged design  Ease of access and O2E Series (Op mal Opera ng Efficiency): kVAr, Power Factor, Lube Oil Pressure, Engine Temp, RPM, Run
 500 hours lube-oil serviceability Hours, Ba ery condi on etc.
Genset ra ngs are selected based on the present load and future
change period  Insula on confirms to UL94- expansion. Fuel efficiency of most Gensets is op mized at the full Diagnos c Features: Ba ery charging failure, Over speed and Under
HF1 class for flammability ra ng of the Genset. speed, Over Current, Over voltage and Under Voltage, Over kilo Wa ,
In prac ce, Gensets rarely get loaded to full capacity. Power demand Phase Seq., Phase missing, Earth Fault trip.
varia ons across day & night, weekdays & weekends. Summer & Low lube oil Pressure, High Engine Temperature, Low and High ba ery
winter lead to an average 50-70% loading on the Gensets. voltage, Low Fuel Level, Over Crank
Controller Alternator protec on, Rou ne Maintenance
 Microprocessor based with  Best in class efficiency Considering this prac cal situa on, KOEL has extended fuel efficiency
indicator, Genset Test Facility, Mains ENGINE SPEED

graphical LCD display  Minimum harmonics op miza on from 100%, right up to 50% Actual
Frequency. 1498 RPM
 Best in class monitoring and interference of rated load.
Zo
ne
Op onal Features: Modbus
diagnos c capability  Vacuum pressure impregna on Combina on of best-in-class efficiency communica on, Synchroniza on,
 Communica on configura on  Epoxy gel coa ng on the & O2E provides a double advantage. Canopy Temperature
f Genset kVA
enabled winding %o
Controller

Vous aimerez peut-être aussi