INSTRUCTION MANUAL & OBSERVATION BOOK

CLRR10- APPLIED ELECTRICAL AND ELECTRONICS


ENGINEERING LABORATORY

DEPARTMENT OF
ELECTRICAL AND ELECTRONICS ENGINEERING
NATIONAL INSTITUTE OF TECHNOLOGY
TIRUCHIRAPPALLI - 620015
DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING
NATIONAL INSTITUTE OF TECHNOLOGY TIRUCHIRAPPALLI

CLRR10: APPLIED ELECTRICAL AND ELECTRONICS


ENGINEERING LABORATORY
Name:

Roll Number:

Batch:

INDEX
Sl. Date Marks (20)
Name of the Experiment Signature
No.

TOTAL
CIRCUIT DIAGRAM – SPEED CONTROL OF DC SHUNT MOTOR

Fuse
+

A
F

D +
230 V
M
P
DC S ¯ Va –
V
Supply T
+ FF −
AA
If –A

Fuse

PANEL BOARD

NAME PLATE DETAILS

MOTOR

RATED VOLTAGE =

RATED CURRENT =

RATED POWER =

RATED SPEED =
Experiment No. Date:

SPEED CONTROL OF DC SHUNT MOTOR

AIM
To obtain the no load speed characteristics of DC shunt motor by means of field and
Armature control methods.

APPARATUS REQUIRED

Sl. No. Name of the apparatus Range Quantity

1. Voltmeter

2. Ammeter

3. Wire wound rheostat

4. Connecting Wires

PRECAUTIONS

1. Appropriate fuse wires should be fixed.


2. The DPST switch should be in open position.
3. The motor field rheostat should be kept at minimum position and armature
rheostat should be kept at maximum position.
DESIGN OF APPARATUS REQUIRED
PROCEDURE
FIELD CONTROL METHOD

1. Make the connections as per the circuit diagram 2.1.


2. Close the DPST switch.
3. Set the armature voltage of the motor at a certain value by adjusting the armature
rheostat of the motor.
4. Vary the field rheostat of the motor and note down the field current and the
corresponding motor speed.
5. Repeat steps 3 and 4 for two more different values of the armature voltage.
6. Bring the field and armature rheostats of the motor to their initial position.

ARMATURE CONTROL METHOD

1. Set the field current at a certain value by adjusting the field rheostat of the motor.
2. Vary the armature rheostat of the motor and note down the armature voltage and
the corresponding motor speed.
3. Repeat steps 1 and 2 for two more different values of the field current.
4. Bring the field and armature rheostats of the motor to their initial position.
5. Open the DPST switch and disconnect the circuit.
TABLE – FIELD CONTROL METHOD

Va1 = (V) Va2 = (V) Va3 = (V)


Sl. No.
If (A) N (rpm) If (A) N (rpm) If (A) N (rpm)

1
2
3
4
5
6
7
8

TABLE – ARMATURE CONTROL METHOD

If1 = (A) If2 = (A) If3 = (A)


Sl. No.

Va (V) N (rpm) Va ( V ) N (rpm) Va ( V ) N (rpm)

1
2
3
4
5
6
7
8
MODEL GRAPHS

FIELD CONTROL METHOD ARMATURE CONTROL METHOD

Va3  Va2  Va1 If1  If2  If3


If3
If2

If1

N
(rpm) Va3
N
(rpm)
Va2

Va1

If (A) Va (V)
(SPEED N Vs FIELD CURRENT I f ) (SPEED N Vs ARMATURE VOLTAGE V a
RESULT

INFERENCE

CATEGORY MAXIMUM MARKS


MARKS OBTAINED

OBSERVATION/RECORD 8

CONNECTIONS 4

RESULTS 5

VIVA 3

STAFF SIGNATURE