Vous êtes sur la page 1sur 3

1/29/2015 320D & 320D L Excavators A6F00001­UP (MACHINE) POWERED BY C6.

4 Engine(SEBP4954 ­ 31) ­ Systems & Components

Previous Screen
Welcome: j370svc
Product:  EXCAVATOR
Model:  320D EXCAVATOR A6F
Configuration: 320D & 320D L Excavators A6F00001­UP (MACHINE)
POWERED BY C6.4 Engine

Systems Operation 
Air Conditioning and Heating R134a for All Caterpillar Machines
Media Number ­SENR5664­26 Publication Date ­10/01/2014 Date Updated ­10/06/2014

   
i03028705

Refrigerant Orifice Tube System
SMCS ­ 7320­QT 

https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/productsearch/productheaderinfoframeset.jsp&calledpage=/siswe… 1/3
1/29/2015 320D & 320D L Excavators A6F00001­UP (MACHINE) POWERED BY C6.4 Engine(SEBP4954 ­ 31) ­ Systems & Components

Illustration 1 g01507889
(1) Compressor

(2) Condenser

(3) In­line dryer

(4) Desiccant

(5) Orifice Tube

(6) Evaporator

(7) Accumulator

(A) High temperature high pressure refrigerant vapor

(B) High temperature, high pressure refrigerant liquid

(C) Low temperature, low pressure refrigerant liquid vapor mixture

https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/productsearch/productheaderinfoframeset.jsp&calledpage=/siswe… 2/3
1/29/2015 320D & 320D L Excavators A6F00001­UP (MACHINE) POWERED BY C6.4 Engine(SEBP4954 ­ 31) ­ Systems & Components

(D) Low temperature low pressure refrigerant vapor

The air conditioner refrigerant begins to flow in the air conditioning system at refrigerant compressor (1). The
compressor is designed to change the air conditioner refrigerant from a vapor that has low pressure into a
vapor that has high pressure. Also, the compressor changes the refrigerant from a vapor with low temperature
to a vapor with high temperature. The increase in pressure causes the increase in temperature.

The refrigerant is sent through condenser coil (2). In the condenser coil, heat is transferred from the
refrigerant to the outside air. This changes the refrigerant to a high temperature and high pressure liquid.

From condenser coil (2), the refrigerant moves to in­line dryer (3). In in­line dryer (3), moisture is removed
from the refrigerant by desiccant (4). Some orifice tube systems will not contain an in­line dryer. In this case,
the desiccant is located in accumulator (7) .

Next, the refrigerant flows to the orifice tube. When the refrigerant is at the orifice tube, the refrigerant is
changed from a high pressure and high temperature liquid to a liquid vapor mixture that is low pressure and
low temperature.

The low pressure and low temperature refrigerant moves to evaporator coil (6). While the refrigerant is in the
evaporator coil the refrigerant absorbs heat from the cab. This changes the refrigerant to a low pressure and
low temperature vapor.

After the evaporator coil, the refrigerant flows to the accumulator. The accumulator stores liquid refrigerant
that is exiting the evaporator and the accumulator allows only vapor to continue to the compressor.

The low pressure and low temperature vapor returns to the compressor. This marks the end of the cycle. The
cycle is repeated continuously.

Copyright 1993 ­ 2015 Caterpillar Inc.
All Rights Reserved.
  Thu Jan 29 2015 15:40:16 GMT+0800 (Taipei Standard Time) 
j370svc
Private Network For SIS Licensees.

https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/productsearch/productheaderinfoframeset.jsp&calledpage=/siswe… 3/3