505 Digital Governor Manual 85017V1

Appendix.
505 Program Mode Worksheets

Governor Serial Number ______________________

Application ________________________________ Date ___________

For details on individual settings, refer to Chapter 4.

TURBINE START SPEED SETPOINT VALUES


Manual Start YES _____ NO _____ Overspeed Test Lmt (rpm) rpm
Automatic Start YES _____ NO _____ Overspeed Trip (rpm) rpm
Semiautomatic Start YES _____ NO _____ Max Governor Speed (rpm) rpm
Rate to Min (rpm/Sec) rpm/sec Min Governor Speed (rpm) rpm
Valve Lmtr Rate (%/Sec) %/sec Setpt Slow Rate(rpm/sec) rpm/sec
Use Idle/Rated? YES _____ NO _____ Use Remote Speed Setpt ? YES ____NO _____
Idle Setpt (rpm) rpm Rmt Spd Setpt Max Rate rpm/sec
Rated Setpt (rpm) rpm Use Critical Speeds? YES _____ NO _____
Idle/Rtd Rate (rpm/sec) rpm/sec Critical Speed Rate rpm/sec
Use Auto Start Sequence YES _____ NO _____ Critical Speed 1 Max rpm
Cold Start = ( > xx Hrs) HRS Critical Speed 1 Min rpm
Hot Start = ( < xx Hrs) HRS Use Critical Band 2 ? YES _____NO _____
Low Idle Setpt (rpm) rpm Critical Speed 2 Max rpm
Low Idle Delay (Cold) MIN Critical Speed 2 Min rpm
Low Idle Delay (Hot) MIN
Rate to Hi Idle (Cold) rpm/sec OPERATING PARAMETERS
Rate to Hi Idle (Hot) rpm/sec Generator Application? YES _____NO _____
High Idle Setpt (rpm) rpm Use Gen Brkr Open Trip ? YES _____NO _____
High Idle Delay (Cold) MIN Use Tie Brkr Open Trip ? YES _____NO _____
High Idle Delay (Hot) MIN Use KW Droop? YES _____NO _____
Rate to Rated (Cold) rpm/sec KW Max Load __________KW
Rate to Rated (Hot) rpm/sec Droop (%) %
Rated Setpt (rpm) rpm Rated Spd Setpt rpm
Auto Halt at Idle Setpts YES ____NO ____ Use Freq Arm/Disarm ? YES _____ NO _____
Ext Trips in Trip Relay YES ____NO ____ Use Local/Remote YES _____ NO _____
Reset Clears Trip Output YES ____NO ____
DRIVER CONFIGURATION
SPEED CONTROL Act #1 is 4–20 mA? YES _____NO _____
Teeth Seen by MPU Invert Driver Outputs ? YES _____NO _____
Gear Ratio 1 : Use Act 1 Flt Shutdown YES _____NO _____
Failed Speed Level(rpm) rpm Act #1 Dither %
Use Speed Input #2? YES ____NO _____ Use Actuator #2? YES _____NO _____
Failed Speed Level(rpm) rpm Act #2 is 4–20 mA? YES _____NO _____
Off-Line Prop Gain % Act #2 Offset (%) %
Off-Line Int Gain rps Use Act 2 Flt Shutdown YES _____NO _____
Off-Line Deriv Ratio % Act #2 Dither (%) %
On-Line Prop Gain % Use Act #2 as Readout? YES _____NO _____
On-Line Int Gain rps Act #2 Readout is: %
On-Line Deriv Ratio % Readout 4 mA Value Units
Readout 20 mA Value Units

164 Woodward
Manual 85017V1 505 Digital Governor

ANALOG INPUTS CASCADE CONTROL


Analog Input # 1 Function Use Cascade Control? YES _____NO _____
Input 1 4 mA Value Units Invert Cascade ? YES _____NO _____
Input 1 20 mA Value Units Min Cascade Setpt Units
Analog Input # 2 Function Max Cascade Setpt Units
Input 2 4 mA Value Units Casc Setpt Rate (/sec) Units/sec
Input 2 20 mA Value Units Use Setpoint Tracking ? YES _____NO _____
Analog Input # 3 Function Setpt Initial Value Units
Input 3 4 mA Value Units Speed Setpt Lower Limit rpm
Input 3 20 mA Value Units Speed Setpt Upper Limit rpm
Analog Input # 4 Function Max Speed Rate(rpm/sec) rpm/Sec
Input 4 4 mA Value Units Cascade Droop %
Input 4 20 mA Value Units Casc PID Prop Gain %
Analog Input # 5 Function Casc PID Integral Gain rps
Input 5 4 mA Value Units Casc Derivative Ratio %
Input 5 20 mA Value Units Use Remote Casc Setting YES _____NO _____
Analog Input # 6 Function Remote Casc Max Rate Units/sec
Input 6 4 mA Value Units Casc Units of Measure
Input 6 20 mA Value Units
READOUTS
CONTACT INPUTS Analog Readout 1 Is
Contact Input 1 Function Readout 1 4 mA Value Units
Contact Input 2 Function Readout 1 20 mA Value Units
Contact Input 3 Function Analog Readout 2 Is
Contact Input 4 Function Readout 2 4 mA Value Units
Contact Input 5 Function Readout 2 20 mA Value Units
Contact Input 6 Function Analog Readout 3 Is
Contact Input 7 Function Readout 3 4 mA Value Units
Contact Input 8 Function Readout 3 20 mA Value Units
Contact Input 9 Function Analog Readout 4 Is
Contact Input 10 Fctn Readout 4 4 mA Value Units
Contact Input 11 Fctn Readout 4 20 mA Value Units
Contact Input 12 Fctn Analog Readout 5 Is
Readout 5 4 mA Value Units
FUNCTION KEYS Readout 5 20 mA Value Units
F3 Key Performs Analog Readout 6 Is
Blink when not Active? YES _____NO _____ Readout 6 4 mA Value Units
F4 Key Performs Readout 6 20 mA Value Units
Blink when not Active? YES _____NO _____

AUXILIARY CONTROL
Use Auxiliary Control ? YES _____ NO _____
Lost Aux Input Shutdown? YES_ ____ NO _____
Use KW Input ? YES _____ NO _____
Invert Aux ? YES _____ NO _____
Min Aux Setpt Units
Max Aux Setpt Units
Aux Setpt Rate units/sec Units/sec
Use Aux Enable? YES _____ NO _____
Setpt Initial Value Units
Aux Droop %
Aux PID Prop Gain %
Aux PID Integral Gain rps
Aux Derivative Ratio %
Tiebrkr Open Aux Disable YES ____NO _____
Genbrkr Open Aux Disable YES ____NO _____
Use Remote Aux Setting YES _____ NO ____
Remote Aux Max Rate Units/sec
Aux Units of Measure

Woodward 165
505 Digital Governor Manual 85017V1

RELAYS COMMUNICATIONS
Use Relay #1? YES ____NO _____ Use Communications ? YES _____ NO _____
Relay # 1 is Level Switch? YES ____NO _____ Use Modbus Port 1? YES _____ NO _____
Relay 1 Is Level Sw For Mode Ascii=1 Rtu=2
Relay 1 ON Level Units Modbus Device #
Relay 1 OFF Level Units Port #1 Driver
Relay 1 Energizes On Port #1 Baud Rate
Use Relay # 2? YES _____NO _____ Port #1 Stop Bits
Relay # 2 is Level Switch? YES ____NO _____ Port #1 Parity
Relay 2 Is Level Sw For Use Modbus Port 2? YES _____NO _____
Relay 2 On Level Units Mode Ascii=1 Rtu=2
Relay 2 Off Level Units Modbus Device #
Relay 2 Energizes On Port #2 Driver
Use Relay # 3? YES _____NO _____ Port #2 Baud Rate
Relay # 3 is Level Switch? YES ____NO _____ Port #2 Stop Bits
Rly 3 Is Level Sw For Port #2Parity
Relay 3 On Level Units
Relay 3 Off Level Units
Relay 3 Energizes On
Use Relay # 4? YES _____NO _____
Relay # 4 is Level Switch? YES ____NO _____
Rly 4 Is Level Sw For
Relay 4 On Level Units
Relay 4 Off Level Units
Relay 4 Energizes On
Use Relay # 5? YES _____NO _____
Relay # 5 is Level Switch? YES ____NO _____
Rly 5 Is Level Sw For
Relay 5 On Level Units
Relay 5 Off Level Units
Relay 5 Energizes On
Use Relay # 6? YES _____NO _____
Relay # 6 is Level Switch? YES ____NO______
Rly 6 Is Level Sw For
Relay 6 On Level Units
Relay 6 Off Level Units
Relay 6 Energizes On

166 Woodward