ISSUE
#. ZF-cPOWER RECALIBRATION
Hydrostatic and clutch calibration should be performed under the following conditions.
- Transmission oil is changed.
- Transmission control unit (TCU) is replaced.
- Transmission is replaced.
- There is a problem with the shifting quality of the transmission.
* When the transmission is recalibrated, it is recommended to perform hydrostat calibration prior to clutch calibratio
* Please refer the attached instructions to understand how to recalibrate them with ZF TEST MAN, or contact ZF dea
* Doosan's technician will be able to recalibrate them via Gauge Panel as below.
Shop Manual 1229~1231pg
Doosan Infracore | Doosan Tower 27th Floor, 18-12, Euljiro-6Ga, Jung Gu, Seoul, Korea | Tel : +82-(0)2-3398-2163 | Fax +82-(0)2-3398-8565
#. Oil information
- When each region is not able to secure the oil confirmed by ZF, please contact a local ZF dealer to find out proper
substitutions.
Doosan Infracore | Doosan Tower 27th Floor, 18-12, Euljiro-6Ga, Jung Gu, Seoul, Korea | Tel : +82-(0)2-3398-2163 | Fax +82-(0)2-3398-8565
Upon its completion, the F/R/N indicator lamp at the center of the panel blinks. Then, the operator can start driving a
releasing the parking brake.
* Do not release the parking brake before its completion.
Doosan Infracore | Doosan Tower 27th Floor, 18-12, Euljiro-6Ga, Jung Gu, Seoul, Korea | Tel : +82-(0)2-3398-2163 | Fax +82-(0)2-3398-8565
#. Gear Box information
Doosan Infracore | Doosan Tower 27th Floor, 18-12, Euljiro-6Ga, Jung Gu, Seoul, Korea | Tel : +82-(0)2-3398-2163 | Fax +82-(0)2-3398-8565
#. Speed sensor information
Doosan Infracore | Doosan Tower 27th Floor, 18-12, Euljiro-6Ga, Jung Gu, Seoul, Korea | Tel : +82-(0)2-3398-2163 | Fax +82-(0)2-3398-8565
#. Filter Information
- First oil change after 2,000 operating hours.
Further oil changes after 2,000 operating hours.
Oil filter must be replaced at each oil change.
*After each oil change first calibrate the hydrostatic unit, then the clutches. (Ensure cleanliness of oil and filter.)
- The transmission has a filter bypass valve. With the SPN523305 FM10(Oil filter contaminated) error code,
the transmission shows the operator a contaminated filter. After this message at the display, the filter needs to be repl
Doosan Infracore | Doosan Tower 27th Floor, 18-12, Euljiro-6Ga, Jung Gu, Seoul, Korea | Tel : +82-(0)2-3398-2163 | Fax +82-(0)2-3398-8565
- The second filter(hydrostatic filter) needs to be replaced every 4000 operating hours.
CORRECTION
PARTS INFORMATION
AFFECTED MACHINES
Doosan Infracore | Doosan Tower 27th Floor, 18-12, Euljiro-6Ga, Jung Gu, Seoul, Korea | Tel : +82-(0)2-3398-2163 | Fax +82-(0)2-3398-8565
Internal Reference No.
Attachments
EN_4665_751_101 REPAIR INSTRUCTIONS.pdf
cPower_Diagnosis_Handbook_V1.3.1.pdf
EN_4665_758_101_OPERATING INSTRUCTIONS.pdf
EBR_cPower_0000 703 191_EN_ISTALLATION INSTRUCTIONS.pdf
Doosan Infracore | Doosan Tower 27th Floor, 18-12, Euljiro-6Ga, Jung Gu, Seoul, Korea | Tel : +82-(0)2-3398-2163 | Fax +82-(0)2-3398-8565