Please read this instruction manual before using the heat pump. January 2018
SWIMMING POOL HEAT PUMP (PLASTIC SHELL) Directions for installation and maintenance
Contents
2
SWIMMING POOL HEAT PUMP (PLASTIC SHELL) Directions for installation and maintenance
Congratulations on your selection of our heat pump for your comfort conditioning requirements.
Your home is fitted with a unique renewable heating technology, allowing you to benefit from lower
running costs and a more even temperature throughout your home. It will heat your pool water and
keep the constant temperature when air temperature at 5-35℃.
3. SPECIFICATIONS
Model KS70 KS90 KS140 KS170
Air discharge Horizontal Horizontal Horizontal Horizontal
Shell material Plastic Plastic Plastic Plastic
Heating capacity KW 7.0 9.0 13.5 16.5
Heating power in KW 1.6 2.1 3.2 3.9
Power supply V/Ph/Hz 230/1/50 230/1/50 230/1/50 230/1/50
Current (heating) A 7.2 9.5 14.5 17.8
Max current in A 12 16 22 28
Noise dB(A) 49 50 51 52
Ambient Temperature ℃ 5-35 5-35 5-35 5-35
Setting Temperature ℃ 5-35 5-35 5-35 5-35
Brand Toshiba/Hitachi Toshiba/Hitachi Toshiba/Hitachi Toshiba/Hitachi
Compressor
Type Rotary Rotary Rotary Rotary
Refrigerant (R410a) g 1100 1350 2200 2500
Fan quantity 1 1 1 1
Min water flow L/min 60 60 90 90
Water connect Inch 1.5 1.5 1.5 1.5
Heat exchanger Titanium PVC Titanium PVC Titanium PVC Titanium PVC
Flow switch Yes Yes Yes Yes
Pressure protect HP and LP HP and LP HP and LP HP and LP
Display LED LED LED LED
Auto-defrost Yes Yes Yes Yes
Microcomputer control Yes Yes Yes Yes
Unit dimension LXWXH(mm) 1000/340/645 1000/340/645 1150/400/845 1150/400/845
Packing dimension LXWXH(mm) 1120/420/670 1120/420/670 1270/480/870 1270/480/870
Net/shipping weight Kg 56/63 63/70 102/113 105/118
Heating capacity is based on inlet water temperature 25℃,Ambient air temperature 24℃(DB)/19℃(WB)
4
SWIMMING POOL HEAT PUMP (PLASTIC SHELL) Directions for installation and maintenance
5
SWIMMING POOL HEAT PUMP (PLASTIC SHELL) Directions for installation and maintenance
4. GENERAL DIAGRAM OF THE REFRIGERATING CIRCUIT
Heat pumps use electricity to capture heat and move it from outside air to pool water. They don't
generate heat.
As the pool pump circulates the swimming pool water, the water drawn from the pool passes through
a filter and the heat pump. The heat pump has a fan that draws in the outside air and directs it over
the evaporator coil. Liquid refrigerant within the evaporator coil absorbs the heat from the outside air
and becomes a gas. The warm gas in the coil then passes through the compressor. The compressor
increases the heat, creating a very hot gas that then passes through the condenser. The condenser
transfers the heat from the hot gas to the cooler pool water circulating through the heat pump. The
heated water then returns to the pool. The hot gas, as it flows through the condenser coil, returns to
liquid form and back to the evaporator, where the whole process begins again.
Higher efficiency heat pump pool heaters usually use scroll compressors versus the reciprocal
compressors of standard units. Heat pump works efficiently as long as the outside temperature
remains above the 7-20℃ range. The higher of the temperature of outside air they draw in, the more
energy they use.
6
SWIMMING POOL HEAT PUMP (PLASTIC SHELL) Directions for installation and maintenance
5. COMPONENTS VIEWS
5.1 Vertical Models: KS120 / KS150 / KS200 / KS250
12 Manometer 26 Transformer
4 Chassis 18 Condenser
7
SWIMMING POOL HEAT PUMP (PLASTIC SHELL) Directions for installation and maintenance
5.2 Horizontal Models: KS70 / KS90 /KS140 /KS170
8
SWIMMING POOL HEAT PUMP (PLASTIC SHELL) Directions for installation and maintenance
6. CONTROL SYSTEM AND PROTECTION
The heat pump is fitted out with 2 control systems:
- A temperature sensor of the evaporator, it is being used to control defrosting operation..
- A temperature sensor placed on the exchanger, when the temperature of the water reaches the
required temperature, the heat pump will be stopped. The normal cycle will restart when the
temperature in the exchanger drop down to 2°C lower than presetting temperature.
Main protection:
- Protection of lacking water for condenser.
- High and low pressure protection of refrigerant.
- Temperature protection of compressor discharge.
- Integrated to the card, a magnetic ammeter/circuit breaker on the compressor.
If an error occurs on one of these systems (defective system, off-line or abnormal measured value), a
message of error will appear on the display screen; see the paragraph “Error codes and what to do”
of this note.
7. ELECTRIC DIAGRAMS
9
SWIMMING POOL HEAT PUMP (PLASTIC SHELL) Directions for installation and maintenance
KS150
10
SWIMMING POOL HEAT PUMP (PLASTIC SHELL) Directions for installation and maintenance
KS200/KS250
11
SWIMMING POOL HEAT PUMP (PLASTIC SHELL) Directions for installation and maintenance
KS70/KS90
12
SWIMMING POOL HEAT PUMP (PLASTIC SHELL) Directions for installation and maintenance
KS140/KS170
13
SWIMMING POOL HEAT PUMP (PLASTIC SHELL) Directions for installation and maintenance
8. INSTALLATION
8.1 Rules of installation
Electric and plumber job must be carried out according to local standards.
The machine must be installed outside.
8.2 Foundation
Mount the unit on a level, sturdy base, preferably a concrete slab or blocks. The size of the base
should be at least: 1200mm x 900mm
The unit’s supporting base must be high enough to keep it completely free of standing water at all
times.
8.3 Location
Vertical Unit:
This unit features an ‘up-flow’ discharge
for quiet operation. Air is pulled up
through the evaporator coil and
discharged through the top grill. Allow
at least 5 ft. (1.5 m) clearance above
the unit for unrestricted air discharge.
DO NOT install the unit under a porch
or deck
Horizontal Unit:
This unit features a ‘side-flow’
discharge for quiet operation. Air is
pulled up through the evaporator coil
and discharged through the front side
grill. Allow at least 5 ft. (100 cm)
clearance in front of the unit for
unrestricted air discharge.
Power supply
KS120 / KS150: 220~240V, single-phase , 50Hz
KS200 / KS250: 380~400V, triple-phase, 50Hz
KS70 / KS90 / KS140 / KS170: 220~240V single-phase current, 50Hz
Control
The heat pump is fitted out with a Flow Switch to protect it from damage and for cooling circuit
protection.
15
SWIMMING POOL HEAT PUMP (PLASTIC SHELL) Directions for installation and maintenance
9. DISPLAY PANEL
9.1 Buttons
Buttons Function
ON / OFF
Adjustment of the temperature desired; Adjustment of the start and stop hour;
Adjustment of the temperature desired; Adjustment of the start and stop hour;
To adjust the current hour and function timetable ( set a starting hour )
To adjust the current hour and function timetable ( set a stopping hour )
16
SWIMMING POOL HEAT PUMP (PLASTIC SHELL) Directions for installation and maintenance
9.2 Operation
External appliance or Heat pump
Display
button of heat pump answer
Engage the circuit
breaker of the heat
Put the heat pump
Indicate the
pump under
current hour
tension
Up and Down
The heat pump
Set the wished
heats until the
temperature into
adjustable from required
the Heat pump
Heating mode: temperature
10°C to 35°C
17
SWIMMING POOL HEAT PUMP (PLASTIC SHELL) Directions for installation and maintenance
9.3 Adjustment of time and timer
21 : 13
Press on the for 5 seconds. The hour setting
The left-digits (hour) flash
mode is activated, the hours light.
15 : 13
Set the hour using the
Setting the time 15 : 13
Press The right-digits (hour) flash
15 : 30
Set the minutes using the
21 : 13
Press on the twice. The left-digits (hour) flash
15 : 13
Set the hour using the
15 : 13
Setting the timer
Press to go to minutes setting The right-digits (hour) flash
15 : 30
Set the minutes using the
15 :30
Press to confirm the setting
9.4 Settings
9.4.1 Manual defrosting:
The heat pump is set for defrosting automatically.
Under special conditions, it is possible to force defrosting by pressing the button . The default
force defrost time is 8 minutes. This defrosting could be stopped by pressing the button OFF.
18
SWIMMING POOL HEAT PUMP (PLASTIC SHELL) Directions for installation and maintenance
Current
Item NO.
temperature
Item NO.
Setting Value
19
SWIMMING POOL HEAT PUMP (PLASTIC SHELL) Directions for installation and maintenance
9.4.5 Reset Button:
when press the button for 4 seconds, and the following points will return to initial state
(Windows default):
0. Flow switch detection: 0
1. Defrost starts temperature: -7℃
2. Defrost stops temperature: 10℃
3. Interval of defrost : 45 minutes
4. Time of defrost : 8 minutes
Stage 1:
Access to the seal of the filling gas valve
in removing the rubber cover ; before starting the heat pump,
connect the manometer, the needle must shows before
starting and to an ambient temperature around 20℃,
a pressure from 14 to 16kg/cm².
Stage 2:
Close completely the bypass valve and open largely inlet and outlet valves of the heat pump; in these
conditions the totality of the water flow goes by the heat pump.
Put into service the Heat Pump in heating mode, wait for the indicated pressure being stabilized; the
correct setting of the pressure is from 28 to 30 kg/cm²;
In most of cases (pump of filtration given a flow until 20m3/h) you do not have to open the bypass
valve.
If the stabilized pressure is under 28kg/cm², the progressive opening of the bypass valve will allow
rising this pressure.
The adjustment of the bypass valve done, you have in principle no reason to modify it during the
season. See the paragraph “Environment problem” too.
10.2 Defrosting
The defrosting is necessary only in heating mode. Steps for defrosting:
1) To start: Defrosting starts if the following conditions are fulfilled at the same time:
a. The compressor and the fan motor run without stopping;
b. The defrosting sensor temperature lower than 3℃, and the duration of time more than 45 minutes;
c. The defrosting sensor temperature goes down to -7°C (factory setting).
2) The compressor and the fan stop;
3) After 10 seconds, the 4 way valve shifts
4) Five seconds after its stop, the compressor starts alone and the accumulated freeze on the gills
becomes melting, what is generally with a steam cloud.
5) Stop: The defrosting stops if one of the following conditions is fulfilled:
a. The defrosting operates 20 seconds and the detected temperature by the defrost sensor goes
up to 10°C (factory setting).
b. The defrosting mode had run totally 8 minutes
20
SWIMMING POOL HEAT PUMP (PLASTIC SHELL) Directions for installation and maintenance
6) The compressor stops
7) After 10 seconds the 4 way valve shifts
8) Five seconds after its stop the compressor and the fan start for restarting in heating mode.
The temperature sensors of compressor outlet, the magnetic circuit breaker on the compressor
power supply, are both protect compressor from damages caused by extreme weather conditions;
when compressor stop, the error messages E 05 or E 06 will display on the control panel.
Note: these error codes are likely to occur if temperature of swimming pool water is high and
the ambient air is hot.
21
SWIMMING POOL HEAT PUMP (PLASTIC SHELL) Directions for installation and maintenance
11. ERROR DIAGNOSIS AND SOLUTION
This table explains the meaning of error diagnosis and solution.
22
SWIMMING POOL HEAT PUMP (PLASTIC SHELL) Directions for installation and maintenance
12. COMMAN QUESTIONS AND ANSWERS
Most problems will be solved by reading the table as below carefully. If the problem is not included in
the list, or if the solutions applied do not solve the problem, refer to contact with dealer.
Problem Probable Cause Explanation / Solution
Check if the circuit breaker is
No power
switched on.
The heat pump does The power supply is defective Call your retailer
not start Reverse of IN and OUT water
Check on the IN and OUT pipes and
pipes of heat pump , water flow
circulating pump
rate is not sufficient
Drain of the condensates not
Water is running below installed or stopped : black, plastic It’s normal: Condensing water will be
the heat pump conduit prolonged with a flexible discharged when heat pump running.
pipe of evacuation
The temperature of the The rising of temperature is more or less rapid according to the volume of
swimming pool is the swimming pool and climate conditions. A thermos cover will improve
increasing very slowly the performances in heating process and decrease the power consumes.
The outside
temperature is too low Try to manually defrost.
White frost or ice
and high humidity
appears outside on the
Outside temperature
fin of the evaporator The automatic de-icing is not sufficient ; stop the
very low and air very
heat pump for the operations of wintering
humid
The unit is not
horizontal or not well
The abnormal noises fixed ; the pipes may
Call your retailer
or vibration of unit have moved into the
pump during the
transport or installation
Please check above series number whether is the same as your heat pump, and always provide the
series number if you ask for help from retailer.