Vous êtes sur la page 1sur 44

13 Steps & 21mins to

Commission Node-B (6601-E)


3G Project – (Guwahati)
6601 Node-B
Software & Cables Required
CABLES:
- Emely Cable (dig. on left)
- LAN Cable
SOFTWARE:
- Total Commander
- File Zilla
- RBS Element Manager
- Basic CV
(CXP9014349%2_R2D01) (File Size –
203MB)
Step-1
• Connect all 4nos E1 in C,D ports of
Junction Box.
• Connect Emely cable to Test Port in CBU
• Connect LAN cable to Ethernet (E) Port in
Junction Box.
• Set Laptop IP:
(IP-169.254.1.2, SUBNET-255.255.255.0, GATEWAY-169.254.1.1)
Step-2
• Connect to HyperTerminal (select COM1 or appropriate
COM port, Restore defaults) and then type subsequent
commands:
- $ reload --
- $ formathd /d
- $ formathd /c2
- Then check if all C2 & D drives have become 0%
- $ vols (/d=0%, /c2=0%)
- $ reload
- $ ifconfig le0 169.254.1.1 netmask 255.255.255.0
Step-3
Then open Total Commander (FTP)
- Select NET – FTP connect, new connection,
session=rbs, hostname=169.254.1.1, username=rbs
- Select the folder containing the Basic CV in laptop and
then press ctrl and drag both c2 and D folder to the
remote client.
// Total time for file transfer takes 300 – 330secs //
- After successful file transfer check in hyper terminal by
command
$ vols (values will be /d=18%, /c2=23%)
Step-4
• $ reload
// Wait till login server ready message appear in
hyperterminal - It takes 90 sec //
Then press enter
Username=rbs
Password=rbs
$ setclock 2011-06-29 16:54:00 //set the current date//
Step-5
• Connect RBS EM – set IP=169.254.1.1
• Select TOOL – Cabinet Equipment Configuration
Go on typing: NEXT – NEXT – NEXT (here select sector
1,2,3) – NEXT (here select ETM position, slot pos=2,
ETM Type=ETMFX11) – NEXT – NEXT – FINISH – YES
// It takes 60 sec for Login Server ready mesg to appear in
hyperterminal then again login to RBS EM //
Step-6
• Connect RBS EM – set IP=169.254.1.1
• Select TOOL – O & M Access Configuration
• Type – NEXT
Click Tick mark on Use Configuration file – browse and select O&M
script.
Type- NEXT-NEXT-NEXT-NEXT-NEXT (here set time)
Time=17:04:23//current time//, Day=29, Month=06, Year=2011, Local Time Zone= IST
. Then Type- NEXT-FINISH-OK
//Here after 10-15secs the lan will get disconnected and we need to
change the laptop IP as per O&M IP, then again it will get
reconnected and Configuration Complete message will appear//
// Also after this step the ETMFX card operation light will become
constant //
Step-7
• Connect RBS EM – set IP=10.142.230.1 //O&M ip//
• Select TOOL – Site Equipment Configuration
Type – NEXT
Click Tick mark on Use Configuration file – browse and
select external.hw.xml script.
Type-OK-NEXT-NEXT
Click Tick mark – configure external alarm control unit
Type-NEXT-NEXT-till page-13 NEXT-FINISH-OK
Step-8
Now we need to create CV so that if
required we can reload from this step.
• Click Software in RBS EM – select CV
• Name=CV_SiteEquip
• Rollback list=Add to List
• Click on Apply
• OK
Step-9
• RBS EM - Select TOOL – Run Command File
Click on: Halt on errors – verbose logging
Browse & select – Iub_EN script and EXECUTE
//Configuration Succeeded mesg will appear at last//
Step-10
Now we need to create CV so that if
required we can reload from this step.
• Click Software in RBS EM – select CV
• Name=CV_IUB
• Rollback list=1
• Click on Apply
• OK
Step-11
Now we will install License in the Node-B:
>Open File Zilla software – Host=10.142.230.1,
username=rbs,passwd=rbs, port=21, quickconnect
>Select the folder containing license in Local site and then
drag the license to c: drive- license in Remote site.
> Now open RBS EM-Licensing-MO properties-Actions-
updatelicensekeyfile –
userid=rbs,passwd=rbs,ipaddress=10.142.230.1,sfile=/c/
license/x912.xml, EXECUTE.
> Then check in features- as per license required details
will be appearing ENABLED & ACTIVATED //if any
featurestate is DEACTIVATED , then right click and select MO properties
and activate it//
Step-12
Now we need to create final CV so that if
required we can reload from this step.
• Click Software in RBS EM – select CV
• Name=CV_License
• Rollback list=1
• Click on Apply
• Set Startable
• OK
SITE READY, MAKE 3G CALL
• Check for alarms in alarm list
• Check if site has been properly defined in
MSS by mgaap:area=all; //to define=
MGAAI:AREA=<CELL_NAME>,SAI=<MCC-MNC-LAC-
SAC>;//
• Check Video call, Packet call.
Cards LED status on Normal Operation
THANK YOU
Amitabh Panda

(NESA CIRCLE)

Vous aimerez peut-être aussi