Vous êtes sur la page 1sur 7

§1.

Technical Specifications:
01. Principle: Three-integral A/D
02.Display Resolution: 1/3000------1/30000
03.A/D Resolution: 200000
04. LO OK HI Checkweigh function
05. Excitation voltage: DC 5V; Up to 4pcs 350Ω load cells or 8pcs 700Ω load cells
06.Display: 6-bit LCD Display: 25mm height,15 status indication
07.Division: 1/2/5/10/20/50/0.1/0.2/0.5/0.01/0.02/0.05/0.001/0.002/0.005/
08.Power: CJ10-2 DC Battery
09. Operating temperature: 0℃ to 40℃.
10. Storage temperature: -25℃ to 55℃
11. Relative humidity: ≤ 85% non–condensing
12. Dimensions: 350 mm × 240 mm ×150mm
13. Weight 3.6Kg

§2. Load Cell Connection:

+E, +R, Positive Excitation Voltage

+S Positive Signal from Load Cell

-S Negative Signal from Load Cell


-E,-R Negative Excitation Voltage

GND

§3. Keypad Functions & Indication Lights


A. Kepad functions:
【∴】Key: Manual accumulation function
【 * 】Key: Function choose and confirm 【→】Key:Move the digits
【↑】Key: Increase the digit or display x10 division 【→0←】Key:Zero, Tare function
B. Indication lights:
〖Ex〗:Anti-Explosion 〖→T←〗
:Tare function
〖 〗 :Battery lower than 30 % 〖AUTO〗 :Automatic accumulation
〖→0←〗 :Zero status 〖◣◢〗 :Stability
〖ANIM〗:Animal weighing 〖lb〗
:Weight Unit is lb
〖X10〗:Display resolution with 10 times increment 〖SET〗:Parameters configuration
〖CAL〗:Calibrating 〖LO〗:Display weight less than the first setpoint
〖HI〗:Display weight more than the second set point 〖OK〗:Display weight more than the first
set point but less than the second set point

§4. Operations:
1. Zero Press 【→0←】key for two seconds to set the zero point and the 【→0←】status LED on.
2. Tare
2.1. Tare
When Tare status LED off and the weight is stable and above zero, press the 【→0←】key to acquire
tare and the Tare status LED on.
2.2. Clean Tare
When Tare status LED on, press【→0←】key will to clean the tare weight, and the Tare status LED off.
2.3. Digital tare
press【→】key , set tare with【→】and【↑】key , then press【→0←】key , the input data will be taken
as the tare weight, Tare status LED on.
2.4.Accumulation operation When weight is stable, press【∴】key to accumulate the current
weight to the total weight, The total number of accumulation will be displayed, such as 〖n 12〗 for
12 times already.
1
★Note:One time weighing can be with only one time accumulation, next accumulation is
allowed on the condition that the reweighing is less than 20d.
3. Accumulation value display(on weighing mode)
Step Operation Display Comments
1 Press 〖n 12〗 Accumulation times display
【*】
2 Press 〖H 23〗 Accumulated weight value (high 4 digits) = 23
【↑】
3 Press 〖L506.5〗 Accumulated weight value (low 4 digits) = 506.5. Then the total
【↑】 value = 23506.5
4. Manual/Automatic Accumulation function choose, animal weighing, peak holding, counting
function choose
Step Operation Display Comments
1 Press 〖n 12〗 Accumulation times display
【*】
2 Press 〖AUt 0〗 Manual/Automatic Accumulation function choose
【* 】 ·AUT=0 Manual accumulation
·AUT=1 Automatically accumulate the weight when it is
stable, and Automatic accumulation LED on,
AUt = 2,Save the display value when it is stable, and when the weight
decreased to be less than 20d, it will accumulate the last stable value and
the 〖AUTO〗 LED on.
AUt = 3,Dynamic weighing mode, when the weight >20d and stable, the
display will be locked for 6 seconds with a buzzer sound of “do” and it locks
the new value when the new stable value displays. When the weight <
20d, it get unlock. Recommend to set FLt﹥20 for automatic accumulation,
and 〖AUTO〗 LED on.
AUt = 4,Peak holding function,when the weight >20d and stable, the
display will be locked for 6 seconds with a buzzer sound of “do”,the locked
value will blink when the weight <20d. It can be unlocked by pressing any
key. , Recommend to set FLt=0 for automatic accumulation, and 〖AUTO〗
LED on.
AUt = 5, Dynamic weighing mode, manual accumulation.
AUt = 6, Peak holding weighing mode, manual accumulation.
AUt = 7,Counting function,
5 Press 〖AUt 0〗 Single-digit flashing
【↑】
6 Press 〖AUt 1〗
【 ↑ 】 〖AUt 2〗
Press 〖AUt 3〗 Example:AUt = 3 means dynamic weighing mode (default
【 ↑ 】 AUt = 0)
Press
【↑】
7 Press 〖 0〗 Return to normal weighing mode
【*】
★ Note:① Sampling:When the net weight is zero (if not zero, press Tare key to get zero), and put
the samples (samples must <200pcs, and can be 1-199) on the platform, and press 【→】 key
and 【↑】key to input the number of the samples.(such as 30)it displays〖Cnt030〗 ,press
【 * 】key to confirm the finish of the sampling, and it return to normal weighing model. Sampling
with protective memory for power break.
Step Operation Display Comments
1 Put 〖 27〗 Put the samples,weight of samples:27,number of samples:
samples 30
2 Press 〖Cnt000〗 Enter the number of samples
【 → 】 〖Cnt000〗 Tens digit flashing
Press
【→】
2
3 Press 〖Cnt010〗
【 ↑ 】 〖Cnt020〗
Press 〖Cnt030〗
【 ↑ 】
Press
【↑】
4 Press 〖 27〗Display the weight of samples:27,【 * 】key for confirmation,
【*】 sampling finish.
5 Press 〖C 30〗 Display the number of the samples:30, 【↑】key is switch key
【↑】 for display the weight or the number of samples.
②Counting operation:Put the article on the platform, and it displays the weight of the goods, press【↑】
key, it display〖C 255〗switch to the number of the articles, when the display is stable, press【∴】key to
accumulate the weight and numbers. Accumulation must be operated while counting.
Step Operation Display Comments
1 Put 〖 230〗 Weight of the goods:230
articles
2 Press 〖C 255〗 Number of the articles:255
【↑】
3 Press 〖n 4〗 Display after 1.5 seconds.
【∴】
〖C 255〗
③ Accumulation retrieve and delete:Available on weighing or counting mode
Step Operation Display Comments
〖C 255〗 On counting mode
1 Press【*】 〖C 1203〗 Display the total number of articles:1203
2 Press 〖H 0〗 Display the accumulated weight (high 4 digits) = 0
【↑】
〖L 1085〗 Display the accumulated weight (low 4 digits) = 1085
3 Press 〖C 255〗 Return to counting function
【↑】
4 Press【→0 〖C 0〗 Delete the accumulated number
←】
5. Accumulated value delete While pressing【 * 】key to display the accumulated time, press【→
0←】key to delete the accumulated value.
6. Digits input Press【→】key to move the digits and the digit (being moved) will flash and
press【↑】key to increase the value of the digit.
7. Battery volume It displays when power on and off: 〖bPt 85〗 means the volume is 85 %
8. Charging indication when the battery volume < 30 %, 〖 〗 light on, recharge in time.
9. working time 40 hours with fully charged (CJ10-2non-maintenance battery built-in).
10. kg→lb exchange The weight unit is Kg when power on, press 【 * 】key for 2 seconds or more, it will
exchange to lb. or lb to kg.
11. Checkweigh function LO OK HI Refer to parameters setting.
§5. Maintenance and Notices
1.Do not use the indicator under strong sunlight for protecting the using life of it. Keep it on flat while using.
2.Do not use it in the places full with dust and strong vibration.
3.Do not overload (including the tare weight) (more than full scale is prohibited.).
4.Do not cleanout the case with strong impregnant (such as, benzene, nitric acid oile, etc.)
5.Keep the interior part of indicator away from the water for avoiding the damage to the electrical components
and electronic shock to people.
6.Switch off the power when some problem happened while in operation. The user (non-manufacturer of scales)
please send the indicator to our company for repair, and it is not allowed to repair at will for avoiding more
damage to the indicator.
7. Power off before replacing the battery and the recharging operation must in the safety area.
8. Recharging time must more than 12 hours.

3
§6. Repair guarantee & Service (Please send back to our company for
Repair guarantee & Service)
The repair guarantee time is 1 year from the selling date of this indicator, and the problem should be
happened due to the problem of the indicator itself while in right operation (not due to wrong operation). We
supply the service to the indicator for life.
★ Note:CJ10-2 Battery excluded;
★Note: The repair guarantee not responsible for all problem of the weighing system while our
indicator only act as a part of this system, we only take charge of the problem caused
from the indicator itself.
§7. Parameter Setting
1. Connecting with the load cell well (screw down the 2 screws in the connector) and then doing parameter set
as follows:
2.Press【*】Key to confirm and enter next step
Step Operation Display Notes
1 Press 〖000000〗 Keeping press【→0←】and switch on the indicator (it is off before
【→0←】 〖999999〗 press the key), it displays〖UE- 30.0〗to allow parameter setting
〖 0〗 and calibration.
2 Press【*】 〖CAL SP〗 Enter the calibration
Press【*】 〖-SEt-〗 Enter the parameter setting
3 Press 〖d 1〗 Division choose
【→】
4 Press 〖d 2〗 0.001-0.002-0.005-10-20-50-100-200-500-0.10-0.20-0.50-1-2-5-
【↑】 〖d 5〗 0.1-0.2-0.5-0.01-0.02-0.05
Press 〖d 0.1〗 Example:division d = 0.1
【 ↑ 】
Press
【↑】
5 Press【*】 〖 6000〗 Full Scale setting
Press 〖000000〗 Ten thousand digit flashing
【→】 〖000000〗 Thousand digit flashing
Press Increase to be 1 for thousand digit
〖001000〗
【→】 Increase to be 2 for thousand digit
〖002000〗 Increase to be 3 for thousand digit,
Press 〖003000〗 Such as F.S.= 3000
【↑】
Press
【↑】
Press
【↑】
6 Press【*】 〖FLt 10〗 00—99 filtering baud choose,the smaller value, the faster
Press 〖FLt 00〗 response,the bigger value, the more stable. Tens digit flashing.
【→】 〖FLt 10〗
Press 〖FLt 20〗
【↑】 〖FLt 30〗 Example:FLt = 30 (Default FLt = 0)
Press
【↑】
Press
【↑】

4
7 Press【*】 〖AUtP10〗 Single-digit = 0 (can’t be modified)
Tens digit means the zero tracking range choose(1~9) :
1: 0.4d 2: 0.8 d 3: 1.2 d 4: 1.6 d 5: 2d
6: 2.4 d 7: 2.8 d 8: 3.2 d 9: 3.6 d
Meantime the tens digit means the zero range when power on
Tens digit = 0 Not zero when power on
Tens digit ≧ 1Zero range is 20﹪F·S when power on.
Press 〖AUtP00〗 Tens digit flashing
【 → 】 〖AUtP10〗 Tens digit increase to be 1(default AUtP = 10)
Press
【↑】
8 Press【*】 〖 1000〗 The first set point setting (Lo value set) such as:998
Press with【→】 【↑】keys
【→】 〖000998〗
Press
【↑】
9 Press【*】 〖 2000〗 The second set point setting (Hi value set) such as:1002
Press ★Present weighing<998 LO Light on
【→】 〖001002〗 998 ≤ Present weighing < 1002 OK Light on
Press Present weighing≥ 1002 HI Light on
【↑】
10 Press【*】 〖 0.0〗 Parameter setting finish and enter the calibration mode
§8. Calibration
1. Calibration
After the finish of above parameter configuration, it enters the calibration mode (if not power off) and the steps
as follows:
Step Operatio Display Notes
n
1 Press【*】 〖CAL SP〗 Calibration status
Press 〖CAL 00〗 Enter the zero calibration
【→】
2 Press【*】 〖----------〗 Being zero point calibrated
〖 3000〗 Displays the F.S. after several seconds
3 Put F.S. 〖----------〗 Being calibrated for F.S.
weights 〖 3000〗 Displays the F.S. after several seconds and end calibration.
Press【*】
4 Press 〖000000〗 If the weights are not maximum capacity, input the actual value
【→】 〖000000〗 (what the capacity of the weights used for calibration) by pressing
Press 〖001000〗 【→】and【↑】keys.
【→】 〖002000〗 Thousand digit flashing.
Press Thousand digit increased to be 1
【↑】 Thousand digit increased to be 2
Press For example, the calibrating weights is 2000
【↑】
5 Press 〖---------〗 Being calibrated
【*】 〖 2000〗 Displays the calibrating weights value after several seconds and
end calibration.
2. Single zero point calibration(If the zero point output of the load cell is more than 20%,or displays H or
L, use this mode)
Step Operation Display Notes
1 Press 〖0〗~〖9〗 Keeping press【→0←】and switch on the indicator (it is off before
【→0←】 〖 0〗 press the key), it displays〖UE- 30.0〗to allow parameter setting
and calibration.
2 Press【*】 〖CAL SP〗 Enter the calibration
Press 〖CAL 00〗 Enter the parameter setting
【→】

5
3 Press【*】 〖----------〗 Being zero point calibrated
〖 XXX.X〗 Displays the F.S. after several seconds
4 Press 〖 000000 〗 Single zero point calibrated finish
【→】 〖----------〗
Press【*】
§九. Check the A/D conversion internal code
Confirm the load cell connection well and to check the A/D internal code, the normal A/D conversion
internal code is around: 38000.
After the finish of above parameter configuration, it enters internal code checking (if not power off) and the
steps as follows:
Step Operation Display Notes
1 Press【*】 〖CAL SP〗 Calibrating
2 Press【*】 〖 -SEt-〗 Parameter setting
3 Press【*】 〖 -A-d-〗 A/D Conversion internal code
4 Press 〖 40000〗 Displays A/D code,such as 40000
【→】
5 Press【*】 〖 0〗 Return to normal weighing mode
§10. Referenced norms:
Q/SXBM1-2003 XK315---Series weighing indicator;
GB3826.1-2000 Electric-equipment for explode gas Chapter I:General requirements
GB3826.2-2000 Electric-equipment for explode gas Chapter II:isolation type“d”
GB3826.3-2000 Electric-equipment for explode gas Chapter III:Increment-safety type “e”
GB3826.4-2000 Electric-equipment for explode gas Chapter IV:Inbeing-safety type“i”
GB3826.8-2000 Electric-equipment for explode gas Chapter VIII:“H”type electronic equipment
GB3826.9-2000 Electric-equipment for explode gas Chapter IX: “m”type electronic equipment
§11.Classification.
Belongs to anti-explosion by classified by purpose
§12.Model
Normally with“-B”
§13. Technical requirements
Performance must according to national standard GB3836.
§14. Signs

1. Inspection organization sign

2. Anti-explosion sign Ex ibⅡT4

3. Anti-explosion qualification certificate:GYB06955


4. Relative warning items
4.1 Charging the battery must in safety area !
4.2. Must power off before replacing of the battery!
4.3. Do not wipe the indicator with dry cloth to avoid static electricity!
5. Safety parameters
5.1. This indicator is the key component in the inbeing safety type weighing system, and it can
be installed in “Area 1” and “Area 2”
5.2. Operating temperature range:0℃~+40℃。
5.3. This indicator must be powered by the anti-explosion approved and with ampere-limiting
CJ10-2 battery, and the charging must in the safety area.
5.4. This indicator without printing and communication functions.
5.5. The output parameters of this indicator as follows while connecting with inbeing safety load
6
cell:
Uo=6.0V;lo=127mA;Po=190mW;Co=39μF,Lo=2mH
While connecting,the following demands must be met:Uo≤Ui;lo≤li;Po≤Pi;Co≥Ci+Cc;
Lo≥Li+Lc
(Notes:Cc and Lc represent the distributing capacitance and inductance of the cable)
6. The installation, operation and maintenance must according to the operation manual,
GB3836.13-2000“Electric-equipment for explode gas Chapter 13: Repair for electric-equipment
for explode gas” 、GB3836.15-2000“Electric-equipment for explode gas Chapter 15: Installation in
dangerous area (coal mine excluded)” and GB50257:1996“ Inspection and approval norms for
installation in explosion and fire environment).
§15. Battery power supply
1. Model:CJ10-2。
2. Rechargeable battery norms:GB3836.4 —2000 item 7.4.8. regulation.
3. The design of the battery must according to:GB3836.4 —2000 item7.4. regulation and with
regulated code and marked on the labels of the product.
4.Test:by the national authorized organization and according toGB3836.4 —2000 item 10.9
regulation.
5. Charging time must more than 12 hours.

Vous aimerez peut-être aussi