Vous êtes sur la page 1sur 4

National Iranian Oil CONT. No. : 1187/EB-GN/DBS-BD01-00 REF. No.

: 1187-SP-50-52 (2)
Engineering and
Construction Company DOCUMENT CODE PAGE 1 OF 4

Project : PLAN/PRJ UNIT PHASE DISC


DOC.
SER. NO.
REV.
DATE
TYPE NO.
Gurreh-Jask Pipeline & 1187 00 EB PL SP 5052 B0 08-Feb-2017
Facilities Basic Design

Project Specification For


Pipeline Valves

B0 08-Feb-2017 AFD M.Movahhed F.Abolghasemi S.Fazeli


A2 04-Feb-2017 IFA M.Movahhed F.Abolghasemi S.Fazeli
A1 31-Dec-2016 IFA M.Movahhed F.Abolghasemi S.Fazeli
A0 12-Nov-2016 IFA M.Movahhed F.Abolghasemi S.Fazeli

REV. DATE DESCRIPTION PREPARED CHECKED APPROVED


CONT. No. : 1187/EB-GN/DBS-BD01-00 REF. No.: 1187-SP-50-52 (2)

Project : Gurreh-Jask Pipeline & Facilities Basic Design PAGE 2 OF 4

TABULATION OF REVISED PAGES


Revisions Revisions
Sheet Sheet
A0 A1 A2 A3 A4 A5 A6 A7 A0 A1 A2 A3 A4 A5 A6 A7
1 X 39
2 X 40
3 X X X 41
4 X X X 42
5 43
6 44
7 45
8 46
9 47
10 48
11 49
12 50
13 51
14 52
15 53
16 54
17 55
18 56
19 57
20 58
21 59
22 60
23 61
24 62
25 63
26 64
27 65
28 66
29 67
30 68
31 69
32 70
33
34
35
36
37
38
CONT. No. : 1187/EB-GN/DBS-BD01-00 REF. No.: 1187-SP-50-52 (2)

Project : Gurreh-Jask Pipeline & Facilities Basic Design PAGE 3 OF 4

1. INTRODUCTION
This Project specification is an addendum to the NIOEC Standard Specification NIOEC-SP-
50-52 (0) and is issued for Basic Design Phase of Gurreh- Jask Pipeline and Facilities project.
The following annotation, as specified hereunder, have been used to indicate the type of
change made to the equivalent clause of NIOEC Specification.

Substitution: The clause in NIOEC Specification shall be deleted and replaced by the new
clause in this Job Specification.

Deletion: The clause in NIOEC Specification shall be deleted without any replacement.

Addition: The new clause with the new number shall be added to the relevant section of
NIOEC Specification.

Modification: Part of the clause or paragraph in NIOEC Specification shall be modified


and/or the new description and/or statement shall be added to the clause or paragraph as
given in this Job Specification

The clause or section numbering of mentioned NIOEC Specification has been used
throughout this Job Specification.

The clauses which are not mentioned in the following amendments shall be considered
unaltered.

2. MODIFICATION TO NIOEC SPECIFICATION

This Job Specification is based on relevant NIOEC Specification (NIOEC-SP-50-52) with the
following modifications:

Part Seven – Ball Valves (Addition)


4. Trunnion Mounted & Floating Ball Valves
CONT. No. : 1187/EB-GN/DBS-BD01-00 REF. No.: 1187-SP-50-52 (2)

Project : Gurreh-Jask Pipeline & Facilities Basic Design PAGE 4 OF 4

4.1.3 Ball valves shall be of the "trunnion" type. However, "floating" type ball valves, if
manually operated, are acceptable in the following cases only (actuated valves must be
trunnion mounted exclusively, whichever their size or pressure class):
• Pressure class 150: Diameters up to 6 inches
• Pressure class 300: Diameters up to 4 inches
• Pressure classes 600, 900, and 1500: Diameters up to 1 ½ inches (included)

3. ATTACHMENT
NIOEC-SP-50-52(0) NIOEC Specification for Pipeline Valves

Vous aimerez peut-être aussi