WHAT IS ANTI TERMITE RETICULATION SYSTEM

Anti termite Pipe

ANTI TERMITE TREATMENT THROUGH PIPING METHOD

Termite Treatment through piping method/Termite tubing system also known


as Pipe Reticulation systemis a revolutionary system designed to effectively treat the
area under concrete slabs or before flooring is done . It is system which is replenishable
unlike older termite treatment methods. The reticulation system is a network of
underground specially designed pipes( rubberised membrane) to induce anti-termite
chemical uniformly throughout your Building’s foundations. Regulating the chemical flow,
this system helps to protect against invasion by termites in future which would otherwise
enter from the outside of your home or from under the floor. We recommend Termite
reticulation system for Anti termite treatment because it is extremely durable and gives
a very robust protection to a new building and works as a highly effective termite shield
for years together. Our Anti termite Reticulation system is being widely used in Indian
construction industry including new homes, offices and other commercial buildings.

How it works ?
It involves lying of special flexible, continuously perforated 16 mm dia pipe along the
internal periphery of the building and centre of the flooring using grid design (every 5 feet).
This placement of perforated pipes (made of rubberised membrane) is done along the
flooring just before laying of the sand bed/sub grade or before fixing the floor marble/tiles.
This perforated pipe has emitters fabricated in them which allow uniform distribution of
termiticide under the entire flooring . These emitters distribute chemical at a pre calculated
rate, and reduces the risk of any area being untreated. Use of continuously perforated
porous pipe ensures no debris , clay or concrete will block the pipe and make it
ineffective. The pipe structure pushes the substrate aside and prevents clogging.
The open ends of this network of pipes are joined at several Junction Boxes (Refilling
points) for

Termite Reticulation Box


periodical recharging of termite chemical. Generally these junction boxes are installed on
the outer walls in a concealed manner or match the aesthetics of the building exteriors.
Refilling points are installed along the external wall so that the termiticide could be applied
from outside the building without causing any disturbance to the occupants.

Termite control chemical emulsions are induced at low pressure through these junction
points (refilling points). Low pressure ensures even distribution of termiticide emulsion at
all delivery points and finally to entire network of porous pipe. Tests have been
conducted on our system and it has been proved that over a 30 metre distance there is
complete and uniform distribution of termiticide along the entire length of a single line
system. No other Anti termite treatment method can match these results.This creates a
continuous chemical barrier under the floor and impede termites invasion through soil and
deny access to the structure of the building. Balancing of network of reticulate piping
system is an important component of any termite Pipe reticulation treatment method.
Reticulation networking at plinth beam level
Recharging of Porous Piping System
The system must be recharged @ 5 lit. per sq. mtr. of the Horizontal surface area. This
must be repeated every 3-4 years to give ongoing protection against termite entry to
your home. However regular termite inspections are recommended as an integral part of
a Termite Management System.

Anti termite Piping Recharge


This system has been designed robustly to achieve a minimum Service Life of over 35
years. What more, this entire job of floor networking, installation and testing is done
by our trained and experienced team of technicians who have specially been trained for
this job and have years of hands on experience in construction industry and are well
versed with various aspects of construction stages
o The advantages of termite reticulation treatment are as under:
o No excavation or Drilling the holes in floor to inject termite chemical is required.
o Tedious work of removing the furniture in the area is not required.
o No pungent smell of the termite chemical is released in the premise.
o No exposure of insecticides to occupants of the building.
o Installation of piping system is warranted for 20 years with refilling every Third
year.
o Unlike conventional termite injection method there is even distribution of the
chemical under the floor.
o No Stains discolouring or marks on the costly floors.
o The cost benefit ratio when compared with traditional methods of termite treatment,
over longer periods is considerable as recharge costs are significantly lower than a
drill and fill method.
o Construction contractors and builders are not required to make special provisions for
the Anti termite Pipe reticulation system during preparation for construction and
no construction activity is held up.

Anti termite treatment with Reticulation system


We are a long established and old company in India with many Hundreds of successful
installations since 2010. You can Call us for free inspection of your construction site .
We View plans and inspect site prior to start of System Installation. We thoroughly study
the plan for footing, slab, plumbing, electrical, and any other construction details.

Termite piping layout


Thereafter rough sketch diagram for piping network is prepared to ensure minimal
interference with other building procedures. You can obtain the copy of our plan and
discuss suitable delivery (refill) points and consult with your Builder/Architect/contractor.
Once the plan is approved and estimate approved, we set date for start of installation and
end date for procedure. Once the job is complete and system recharged with the
chemical, we hand over the site network plan to the customer for his future reference.

Vous aimerez peut-être aussi