Summary: Reset Management Switch

Instructions: How to reset the management switch from the primary control station (slot_0)

Method 1

1. Log into the CS via SSH, ensure that you are logged into slot_0:
/nasmcd/getreason
10 - slot_0 primary control station
11 - slot_1 secondary control station
5 - slot_2 contacted
5 - slot_3 contacted

2.Check the system first:


/nasmcd/sbin/setup_enclosure -checkSystem

Performing Detail System check ...


System discovery on both subnets .... OK
Information: Mgmtswitches discovered in the system are:
Discovered Mgmtswitch with Enclosure ID 0 MgmtSwitch-A IP (128.221.252.50) MgmtSwitch-A MAC (00:60:16:43:da:58)
address
Discovered Mgmtswitch with Enclosure ID 0 MgmtSwitch-B IP (128.221.253.50) MgmtSwitch-B MAC (00:60:16:43:da:b2)
address
Detail System check OK
checkSystem Completed

3. Check the cabling: /nasmcd/sbin/setup_enclosure -checkCable

Executing -checkCable option


System discovery on both subnets ... OK
Pair up all discovered Mgmtswitches ... OK
Verify no cross-connected cabling error ... OK
Collect Enclosure cabling topology ...... OK
Examine Enclosure cabling ...
Cabling of Enclosure at position 0 ... OK
checkCable Completed

4. Reset the management switch: /nas/sbin/setup_enclosure -resetMgmtswitches

Method 2

This command automates all of the separate commands above:

/nasmcd/sbin/setup_enclosure -checkSystem [autorepair]

Notes: This process is nondisruptive.