Académique Documents
Professionnel Documents
Culture Documents
PM-64 SERIES
■ General terms and conditions ............. P.1 ■ Sensor selection guide......P.11~ / P.409~
FIBER Related Information
SENSORS ■ Glossary of terms .......................... P.983~ ■ General precautions ..................... P.986~
LASER
SENSORS
PHOTOELECTRIC
SENSORS Conforming to UL Recognition
EMC Directive
MICRO
MICRO
PHOTOELECTRIC
PHOTOELECTRIC
SENSORS
SENSORS
AREA
SENSORS
SAFETY
COMPONENTS
PRESSURE
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE SENSORS
SENSOR
OPTIONS
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS SUNX website http://www.sunx.com
STATIC CONTROL
DEVICES
LASER
MARKERS
Easy connection with a single touch
using commercially-available connectors
11 mm
0.433 in Approximetely
60 %
2.1 mm of previous
0.083 in model
Detachable
Commercially-
available connector
Digital pressure sensor
DP-100 series
ORDER GUIDE SPECIFICATIONS
Connector Built-in U-shaped Micro Photoelectric Sensor
I/O CIRCUIT DIAGRAMS SENSING CHARACTERISTICS PRECAUTIONS FOR PROPER USE
PM-64 SERIES
DIMENSIONS
412
P.413 P.414 P.415 P.415 P.416 P.417~
APPLICATIONS FIBER
SENSORS
Determining the pallet position Sensing the starting point and Sensing the starting point LASER
overrun of a moving body on a rotating body SENSORS
Overrun sensing
PHOTOELECTRIC
Dog SENSORS
Starting
point
The starting MICRO
MICRO
point can be PHOTOELECTRIC
PHOTOELECTRIC
sensed by SENSORS
SENSORS
making a slit in AREA
Starting point sensing the rotating SENSORS
body.
Overrun SAFETY
sensing COMPONENTS
WIRE-SAVING
SYSTEMS
Previous model (Soldering: Connector type) • Automation is hard because of soldering.
Insulation processing • Insulation processing is required. MEASUREMENT
SENSORS
• A large space is necessary at the terminal area.
STATIC CONTROL
• Connectors are not reliable DEVICES
(not fully connected or seated).
Soldering
LASER
MARKERS
Previous model (Converted to the cable-type commercially-availableconnector) • Crimping processing is required in two places.
Intermediate box Commercially-available connector • A set of commercially-available connectors is
necessary.
• There are many processes for cable connections.
• A intermediate box is required.
Crimping processing
Suggestion Selection
Guide
PM-64 series (Built-in commercially-available connector) • Crimping processing makes automation U-shaped
possible so the connectors are also highly
reliable. PM-64
Crimping processing • Soldering, insulation processing, and a PM-24
intermediate box are not necessary.
PM-44/54
• Connectors are widely available.
Convergent
• Mounting in a small space is easy. Reflective
• Strongly connected using a locking connector. PM2
• 1 m 3.281 ft, 2 m 6.562 ft, 3 m 9.843 ft, and 5 m
16.404 ft connector cables are available.
413 Connector Built-in U-shaped Micro Photoelectric Sensor PM-64 SERIES
LASER
SENSORS
Type Appearance(mm in) Sensing range Model No. Output Output operation
PHOTO-
ELECTRIC
SENSORS
NPN open-collector
MICRO
MICRO
PHOTO-
PHOTO-
PM-K64 transistor
K type
ELECTRIC
ELECTRIC
SENSORS
SENSORS 7 0.207 in
26 1.024 in 23 PNP open-collector
AREA
SENSORS
0.906 in PM-K64P transistor
SAFETY
NPN open-collector
COMPONENTS PM-T64 transistor
T type
13.7 0.539 in
PRESSURE
SENSORS
PNP open-collector
26 1.024 in 23
0.906 in
PM-T64P transistor
INDUCTIVE
PROXIMITY
SENSORS
Small and built-in connector type
NPN open-collector
PARTICULAR PM-L64 transistor
L type
USE
SENSORS
15.5 0.610 in
PNP open-collector
SENSOR
OPTIONS
26.2 1.031 in
15.7 0.618 in PM-L64P transistor
5 mm 0.197 in Incorporated with 2 outputs:
WIRE- (fixed) Light-ON / Dark-ON
SAVING NPN open-collector
SYSTEMS 15.5 0.610 in PM-Y64 transistor
Y type
MEASURE-
MENT
SENSORS 22.7 PNP open-collector
13.8 0.543 in 0.894 in PM-Y64P transistor
STATIC
CONTROL
DEVICES
NPN open-collector
LASER
PM-F64 transistor
F type
MARKERS 14 0.551 in
23 PNP open-collector
13.4 0.528 in 0.906 in PM-F64P transistor
NPN open-collector
14 0.551 in
PM-R64 transistor
R type
23 PNP open-collector
13.4 0.528 in 0.906 in PM-R64P transistor
Selection
Guide
U-shaped
U-shaped OPTIONS
PM-64
Recommended connector
Housing
Contact: SPHD-001T-P0.5, Housing: PAP-04V-S (Manufactured by J.S.T. Mfg. Co., Ltd.)
Note: Contact the manufacturer for details of the recommended products.
SPECIFICATIONS FIBER
SENSORS
LASER
Small and built-in connector type SENSORS
Type
K type T type L type Y type F type R type PHOTO-
ELECTRIC
Model No.
Ambient temperature –25 to +55 °C –13 to +131 °F (No dew condensation or icing allowed), Storage: –30 to +80 °C –22 to +176 °F LASER
Environmental resistance
MARKERS
Ambient humidity 35 to 85 % RH, Storage: 5 to 95 % RH
Voltage withstandability 1,000 V AC for one min. between all supply terminals connected together and enclosure
Insulation resistance 50 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure
Vibration resistance 10 to 2,000 Hz frequency, 1.5 mm 0.059 in amplitude in X, Y and Z directions for two hours each
Shock resistance 15,000 m/s2 acceleration (1,500 G approx.) in X, Y and Z directions for three times each
Emitting element Infrared LED (Peak emission wavelength: 940 nm 0.037 mil, non-modulated) Selection
Guide
Material Enclosure: PBT, Slit cover: Polycarbonate
U-shaped
Cable length Total length up to 100 m 328.084 ft is possible with 0.3 mm2, or more, cable. (Note 5)
PM-64
Weight Net weight: 3 g approx.
PM-24
Notes: 1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 °C +73.4 °F.
2) This is the value when a sensing object is moved in a lateral direction to the U-shape. PM-44/54
3) This is the value when a sensing object is moved in a lateral direction to the U-shape and when the inserting length of the sensing board is 5 mm 0.197 in. Convergent
4) The response frequency is the value when the disc, given in the figure below, is rotated. Reflective
PM2
Disk 1.8 mm 0.071 in
Disk
t = 0.2 mm 0.008 in
1.6 mm 0.063 in 1.6 mm 0.063 in
5) Confirm that the sensor terminal voltage is more than 4.5 V when using an extension of over 20 m 65.617 ft.
415 Connector Built-in U-shaped Micro Photoelectric Sensor PM-64 SERIES
LASER
SENSORS PM-□64 NPN output type
PHOTO- I/O circuit diagram Terminal arrangement diagram
ELECTRIC
SENSORS
Color code of connector attached cable
MICRO
MICRO
PHOTO-
PHOTO-
ELECTRIC
ELECTRIC (Brown) +V
SENSORS
SENSORS
ZD1 (Black) Output 1 Load
Sensor circuit
ZD1
Sensor circuit
50 mA max.
Tr1 +
(Black) Output 1 (Note 1,2) 5 to 24 V DC
ZD2 50 mA max. ± 10 %
–
Tr2 Load 1 2 3 4
(White) Output 2 (Note 1,2)
Load
(Blue) 0 V
Terminal No. Designation
Internal circuit Users’ circuit
1 +V
Notes: 1) Make sure to connect terminals correctly as the sensor does not
Selection incorporate a reverse polarity protection circuit. 2 Output1: Light-ON
Guide Further, the output is not incorporated with a short-circuit
protection circuit. Do not connect it directly to a power supply or a 3 Output2: Dark-ON
U-shaped
U-shaped
capacitive load. Faulty wiring may result in damage. 4 0V
PM-64 2) Ensure to insulate the unused output wire.
PM-24
Symbols … ZD1, ZD2 : Surge absorption zener diode
PM-44/54 Tr1,Tr2 : PNP output transistor
Convergent
Reflective
PM2 SENSING CHARACTERISTICS (TYPICAL)
PM-K64(P) PM-L64(P)
Sensing position
Dark- Dark-
ON 9 mm 0.354 in ON
ℓ
7 mm 0.276 in
2.6 mm ℓ
0.102 in
Beam
axis
Light- Light-
ON 0 1 2 3 4 ON 1 2 3 4
0.039 0.079 0.118 0.157 0.039 0.079 0.118 0.157
Operating point ℓ (mm in) Operating point ℓ (mm in)
Connector Built-in U-shaped Micro Photoelectric Sensor PM-64 SERIES
416
PRECAUTIONS FOR PROPER USE Refer to p.986~ for general precautions. FIBER
SENSORS
for personnel protection. • Cable extension is possible up to an overall length of 100 PHOTO-
• In case of using sensing devices for m 328.084 ft with a 0.3 mm2, or more, cable. However, ELECTRIC
SENSORS
personnel protection, use products which since a voltage drop shall occur due to the cable MICRO
MICRO
PHOTO-
meet laws and standards, such as OSHA, extension, ensure that the power supply voltage at the PHOTO-
ELECTRIC
ELECTRIC
SENSORS
ANSI or IEC etc., for personnel protection end of the cable attached to the sensor or at the sensor SENSORS
Further, use small, round type plain washers (ø6 mm 0.2mm2 Up to 10 m 32.808 ft MEASURE-
MENT
ø0.236 in). SENSORS
0.3mm2 Up to 20 m 65.617 ft
STATIC
M3 screws CONTROL
DEVICES
Others LASER
Spring washer MARKERS
Plain washer
• Since the sensor is intended for
use inside machines, no special
( Outer diameter
ø6 mm
ø0.236 in
) countermeasures have been
taken against extraneous light.
Take care that extraneous light is
not directly incident on the beam
receiving section.
• Do not use during the initial transient time (50 ms) after
Wiring the power supply is switched on.
• If the sensor is used in a place having excessive dust, Selection
Guide
Connection method periodically clean the emitting and receiving sections with U-shaped
• Insert the connector attached cable Projection a dry, soft cloth.
[CN-14A(-R)-C□] in the connector • If there is a large surge generating equipment, such as, PM-64
part of this product as shown in the CN-14A(-R)-C□
motor, solenoid, electromagnetic valve, etc., in the vicinity PM-24
<Connector>
right figure. Housing: PAP-04V-S of the sensor, use a surge absorber on that equipment.
PM-44/54
Further, do not run the sensor cables along power lines
<Connector pin position>
(Manufactured by J.S.T.
Mfg. Co., Ltd. ) and use a capacitor between +V and 0 V, if required. Convergent
Reflective
Use the sensor after confirming that the surge has been PM2
eliminated.
Connector pin No. 1 2 3 4
1 2 3 4 Terminal designation +V Output 1 Output 2 0V
Disconnection method
• Pressing the projection of the connector attached cable,
pull out the connector.
Note: Take care that if the cable is pulled out without pressing the projection,
the cable may break.
417 Connector Built-in U-shaped Micro Photoelectric Sensor PM-64 SERIES
FIBER DIMENSIONS (Unit: mm in) The CAD data in the dimensions can be downloaded from the SUNX website: http://www.sunx.com
SENSORS
LASER
SENSORS PM-K64 Sensor PM-T64 Sensor
PHOTO- 26 13.7
ELECTRIC 1.024 0.539
SENSORS 3.5
20 0.138 7
MICRO
MICRO 0.787 0.276 3
PHOTO-
PHOTO- 0.118
ELECTRIC
ELECTRIC 7
Center of beam axis
SENSORS
SENSORS 0.276
0.610
0.283 0.508 6.5
PM-64 0.256
9 20
0.354 0.787 2-ø3.2 ø0.126 mounting holes
PM-24
PM-44/54
Convergent
Reflective PM-F64 Sensor PM-R64 Sensor
PM2
3 3
0.118 0.118
Beam axis and boss Beam axis and boss
7 7
0.276 0.276
Operation indicator (Orange) Operation indicator (Orange)
Center of beam axis Center of beam
and boss ø2.4
ø2.4 ø0.094 ø0.094 axis and boss
13.4 2.5 7 7 2.5 13.4
Beam axis width: 0.528 0.098 0.276 0.276 0.098 0.528 Beam axis width:
0.8 0.031 5 2.6 Center of beam Center of beam axis 2.6 5 0.8 0.031
0.197 0.102 axis and boss and boss 0.102 0.197
9
0.354
23 16.3 16.3 23
0.906 0.642 0.642 0.906 9
8.2 8.2 0.354
0.323 0.323
DIMENSIONS (Unit: mm in) The CAD data in the dimensions can be downloaded from the SUNX website: http://www.sunx.com FIBER
SENSORS
LASER
CN-14A-C□
□ CN-14A-R-C□ Connector attached cable (Optional) SENSORS
PHOTO-
L • Length L ELECTRIC
SENSORS
(1.378
35
) (1.969
50
) Model No. Length L MICRO
MICRO
PHOTO-
PHOTO-
ELECTRIC
(0.315)
8
(0.315)
8
CN-14A(-R)-C1 1,000 39.370
ELECTRIC
SENSORS
SENSORS
AREA
CN-14A(-R)-C2 2,000 78.740 SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
WIRE-
SAVING
SYSTEMS
MEASURE-
MENT
SENSORS
STATIC
CONTROL
DEVICES
LASER
MARKERS
Selection
Guide
U-shaped
PM-64
PM-24
PM-44/54
Convergent
Reflective
PM2