Vous êtes sur la page 1sur 8

411 Connector Built-in U-shaped Micro Photoelectric Sensor Amplifier Built-in

PM-64 SERIES
■ General terms and conditions ............. P.1 ■ Sensor selection guide......P.11~ / P.409~
FIBER Related Information
SENSORS ■ Glossary of terms .......................... P.983~ ■ General precautions ..................... P.986~
LASER
SENSORS

PHOTOELECTRIC
SENSORS Conforming to UL Recognition
EMC Directive
MICRO
MICRO
PHOTOELECTRIC
PHOTOELECTRIC
SENSORS
SENSORS
AREA
SENSORS

SAFETY
COMPONENTS

PRESSURE
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE SENSORS

SENSOR
OPTIONS

WIRE-SAVING
SYSTEMS

MEASUREMENT
SENSORS SUNX website http://www.sunx.com
STATIC CONTROL
DEVICES

LASER
MARKERS
Easy connection with a single touch
using commercially-available connectors

Built-in connector saves space Can be connected using commercially-


This greatly reduces the amount of space taken up
available connectors
compared to previous products. The connector connection type eliminates the extra
The dimension between the beam axis and cable work of soldering and insulation processing. In addition,
Selection bending part has been reduced to half at maximum. the connector used is a commercially-available multi-
Guide
U-shaped
purpose connector which is also currently used by the
DP-100 series of digital pressure sensors.
PM-64 Previous model
Connector type PM-□
□64
PM-24
25.4 mm 26 mm
PM-44/54 1.000 in 1.024 in
Convergent
Reflective
22.3 mm 23 mm
PM2 0.878 in 0.906 in

11 mm
0.433 in Approximetely
60 %
2.1 mm of previous
0.083 in model
Detachable
Commercially-
available connector
Digital pressure sensor
DP-100 series
ORDER GUIDE SPECIFICATIONS
Connector Built-in U-shaped Micro Photoelectric Sensor
I/O CIRCUIT DIAGRAMS SENSING CHARACTERISTICS PRECAUTIONS FOR PROPER USE
PM-64 SERIES
DIMENSIONS
412
P.413 P.414 P.415 P.415 P.416 P.417~

APPLICATIONS FIBER
SENSORS

Determining the pallet position Sensing the starting point and Sensing the starting point LASER
overrun of a moving body on a rotating body SENSORS
Overrun sensing
PHOTOELECTRIC
Dog SENSORS
Starting
point
The starting MICRO
MICRO
point can be PHOTOELECTRIC
PHOTOELECTRIC
sensed by SENSORS
SENSORS
making a slit in AREA
Starting point sensing the rotating SENSORS
body.
Overrun SAFETY
sensing COMPONENTS

Starting point and overrun is PRESSURE


SENSORS
Pallet is stopped by sensing the dog. sensed using the dog on the base.
INDUCTIVE
PROXIMITY
SENSORS
Improved maintenance and workability significantly reduces total cost PARTICULAR
USE SENSORS
The processing cost of the connector cables can be drastically reduced through the use of commercially-available SENSOR
crimping connectors OPTIONS

WIRE-SAVING
SYSTEMS
Previous model (Soldering: Connector type) • Automation is hard because of soldering.
Insulation processing • Insulation processing is required. MEASUREMENT
SENSORS
• A large space is necessary at the terminal area.
STATIC CONTROL
• Connectors are not reliable DEVICES
(not fully connected or seated).
Soldering
LASER
MARKERS
Previous model (Converted to the cable-type commercially-availableconnector) • Crimping processing is required in two places.
Intermediate box Commercially-available connector • A set of commercially-available connectors is
necessary.
• There are many processes for cable connections.
• A intermediate box is required.
Crimping processing

Suggestion Selection
Guide
PM-64 series (Built-in commercially-available connector) • Crimping processing makes automation U-shaped
possible so the connectors are also highly
reliable. PM-64
Crimping processing • Soldering, insulation processing, and a PM-24
intermediate box are not necessary.
PM-44/54
• Connectors are widely available.
Convergent
• Mounting in a small space is easy. Reflective
• Strongly connected using a locking connector. PM2
• 1 m 3.281 ft, 2 m 6.562 ft, 3 m 9.843 ft, and 5 m
16.404 ft connector cables are available.
413 Connector Built-in U-shaped Micro Photoelectric Sensor PM-64 SERIES

FIBER ORDER GUIDE


SENSORS

LASER
SENSORS
Type Appearance(mm in) Sensing range Model No. Output Output operation
PHOTO-
ELECTRIC
SENSORS
NPN open-collector
MICRO
MICRO
PHOTO-
PHOTO-
PM-K64 transistor
K type

ELECTRIC
ELECTRIC
SENSORS
SENSORS 7 0.207 in
26 1.024 in 23 PNP open-collector
AREA
SENSORS
0.906 in PM-K64P transistor

SAFETY
NPN open-collector
COMPONENTS PM-T64 transistor
T type

13.7 0.539 in
PRESSURE
SENSORS
PNP open-collector
26 1.024 in 23
0.906 in
PM-T64P transistor
INDUCTIVE
PROXIMITY
SENSORS
Small and built-in connector type

NPN open-collector
PARTICULAR PM-L64 transistor
L type

USE
SENSORS
15.5 0.610 in
PNP open-collector
SENSOR
OPTIONS
26.2 1.031 in
15.7 0.618 in PM-L64P transistor
5 mm 0.197 in Incorporated with 2 outputs:
WIRE- (fixed) Light-ON / Dark-ON
SAVING NPN open-collector
SYSTEMS 15.5 0.610 in PM-Y64 transistor
Y type

MEASURE-
MENT
SENSORS 22.7 PNP open-collector
13.8 0.543 in 0.894 in PM-Y64P transistor
STATIC
CONTROL
DEVICES
NPN open-collector
LASER
PM-F64 transistor
F type

MARKERS 14 0.551 in
23 PNP open-collector
13.4 0.528 in 0.906 in PM-F64P transistor

NPN open-collector
14 0.551 in
PM-R64 transistor
R type

23 PNP open-collector
13.4 0.528 in 0.906 in PM-R64P transistor

Selection
Guide
U-shaped
U-shaped OPTIONS
PM-64

PM-24 Connector attached cable


Designation Model No. Description
PM-44/54 • CN-14A(-R)-C□
Convergent
Reflective CN-14A-C1 Length: 1m 3.281 ft

PM2 Connector CN-14A-C2 Length: 2m 6.562 ft


attached
cable CN-14A-C3 Length: 3m 9.843 ft
0.2 mm2 4-core cabtyre cable with
CN-14A-C5 Length: 5m 16.404 ft connector on one end
Cable outer diameter: ø3.7mm
Connector CN-14A-R-C1 Length: 1m 3.281 ft
ø0.146 in
attached CN-14A-R-C2 Length: 2m 6.562 ft
cable Connector
Flexible CN-14A-R-C3 Length: 3m 9.843 ft
cable • CN-14A
CN-14A-R-C5 Length: 5m 16.404 ft
Contact
Connector CN-14A Set of 10 housings and 40 contacts
4

Recommended connector
Housing
Contact: SPHD-001T-P0.5, Housing: PAP-04V-S (Manufactured by J.S.T. Mfg. Co., Ltd.)
Note: Contact the manufacturer for details of the recommended products.

Recommended crimping tool


Model No. : YC-610R (Manufactured by J.S.T. Mfg. Co., Ltd.)
Note: Contact the manufacturer for details of the recommended products.
Connector Built-in U-shaped Micro Photoelectric Sensor PM-64 SERIES
414

SPECIFICATIONS FIBER
SENSORS

LASER
Small and built-in connector type SENSORS
Type
K type T type L type Y type F type R type PHOTO-
ELECTRIC
Model No.

NPN output PM-K64 PM-T64 PM-L64 PM-Y64 PM-F64 PM-R64 SENSORS


MICRO
MICRO
PHOTO-
PHOTO-
Item PNP output PM-K64P PM-T64P PM-L64P PM-Y64P PM-F64P PM-R64P ELECTRIC
ELECTRIC
SENSORS
SENSORS
Sensing range 5 mm 0.197 in (fixed)
AREA
SENSORS
Minimum sensing object 0.8 × 1.8 mm 0.031 × 0.071 in opaque object

Hysteresis 0.05 mm 0.002 in or less (Note 2) SAFETY


COMPONENTS
Repeatability 0.01 mm 0.004 in or less (Note 3)
PRESSURE
Supply voltage 5 to 24 V DC ± 10 % Ripple P-P 10 % or less SENSORS

Current consumption 15 mA or less INDUCTIVE


PROXIMITY
SENSORS
<NPN output type> <PNP output type>
PARTICULAR
NPN open-collector transistor PNP open-collector transistor USE
• Maximum sink current: 50 mA • Maximum source current: 50 mA SENSORS
Output • Applied voltage: 30 V DC or less (between output and 0 V) • Applied voltage: 30 V DC or less (between output and +V)
• Residual voltage: 0.7 V or less (at 50 mA sink current) • Residual voltage: 0.7 V or less (at 50 mA source current) SENSOR
OPTIONS
0.4 V or less (at 16 mA sink current) 0.4 V or less (at 16 mA source current)
WIRE-
Output operation Incorporated with 2 outputs: Light-ON / Dark-ON SAVING
SYSTEMS

Under light received condition: 20 μs or less MEASURE-


MENT
Response time Under light interrupted condition: 100 μs or less SENSORS
(Response frequency: 1 kHz or more) (Note 4)
STATIC
CONTROL
Operation indicator Orange LED (lights up under light received condition) DEVICES

Ambient temperature –25 to +55 °C –13 to +131 °F (No dew condensation or icing allowed), Storage: –30 to +80 °C –22 to +176 °F LASER
Environmental resistance

MARKERS
Ambient humidity 35 to 85 % RH, Storage: 5 to 95 % RH

Ambient illuminance Fluorescent light: 1,000 ℓx at the light-receiving face

Voltage withstandability 1,000 V AC for one min. between all supply terminals connected together and enclosure

Insulation resistance 50 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure

Vibration resistance 10 to 2,000 Hz frequency, 1.5 mm 0.059 in amplitude in X, Y and Z directions for two hours each

Shock resistance 15,000 m/s2 acceleration (1,500 G approx.) in X, Y and Z directions for three times each

Emitting element Infrared LED (Peak emission wavelength: 940 nm 0.037 mil, non-modulated) Selection
Guide
Material Enclosure: PBT, Slit cover: Polycarbonate
U-shaped
Cable length Total length up to 100 m 328.084 ft is possible with 0.3 mm2, or more, cable. (Note 5)
PM-64
Weight Net weight: 3 g approx.
PM-24
Notes: 1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 °C +73.4 °F.
2) This is the value when a sensing object is moved in a lateral direction to the U-shape. PM-44/54
3) This is the value when a sensing object is moved in a lateral direction to the U-shape and when the inserting length of the sensing board is 5 mm 0.197 in. Convergent
4) The response frequency is the value when the disc, given in the figure below, is rotated. Reflective
PM2
Disk 1.8 mm 0.071 in
Disk

t = 0.2 mm 0.008 in
1.6 mm 0.063 in 1.6 mm 0.063 in

5) Confirm that the sensor terminal voltage is more than 4.5 V when using an extension of over 20 m 65.617 ft.
415 Connector Built-in U-shaped Micro Photoelectric Sensor PM-64 SERIES

FIBER I/O CIRCUIT AND WIRING DIAGRAMS


SENSORS

LASER
SENSORS PM-□64 NPN output type
PHOTO- I/O circuit diagram Terminal arrangement diagram
ELECTRIC
SENSORS
Color code of connector attached cable
MICRO
MICRO
PHOTO-
PHOTO-
ELECTRIC
ELECTRIC (Brown) +V
SENSORS
SENSORS
ZD1 (Black) Output 1 Load
Sensor circuit

AREA (Note 1,2)


SENSORS Load +
50 mA max. 5 to 24 V DC
Tr1 ± 10 %
ZD2 (White) Output 2 (Note 1,2) –
SAFETY 1 2 3 4
COMPONENTS Tr2 50 mA max.
(Blue) 0 V
PRESSURE Terminal No. Designation
SENSORS
Internal circuit Users’ circuit
1 +V
INDUCTIVE Notes: 1) Make sure to connect terminals correctly as the sensor does not
PROXIMITY incorporate a reverse polarity protection circuit. 2 Output1: Light-ON
SENSORS
Further, the output is not incorporated with a short-circuit
PARTICULAR protection circuit. Do not connect it directly to a power supply or a 3 Output2: Dark-ON
USE
SENSORS capacitive load. Faulty wiring may result in damage. 4 0V
2) Ensure to insulate the unused output wire.
SENSOR
OPTIONS
Symbols … ZD1, ZD2 : Surge absorption zener diode
WIRE- Tr1,Tr2 : NPN output transistor
SAVING
SYSTEMS
MEASURE-
MENT
SENSORS PM-□64P PNP output type
STATIC
CONTROL I/O circuit diagram Terminal arrangement diagram
DEVICES
Color code of connector attached cable
LASER
MARKERS
(Brown) +V

ZD1
Sensor circuit

50 mA max.
Tr1 +
(Black) Output 1 (Note 1,2) 5 to 24 V DC
ZD2 50 mA max. ± 10 %

Tr2 Load 1 2 3 4
(White) Output 2 (Note 1,2)
Load
(Blue) 0 V
Terminal No. Designation
Internal circuit Users’ circuit
1 +V
Notes: 1) Make sure to connect terminals correctly as the sensor does not
Selection incorporate a reverse polarity protection circuit. 2 Output1: Light-ON
Guide Further, the output is not incorporated with a short-circuit
protection circuit. Do not connect it directly to a power supply or a 3 Output2: Dark-ON
U-shaped
U-shaped
capacitive load. Faulty wiring may result in damage. 4 0V
PM-64 2) Ensure to insulate the unused output wire.

PM-24
Symbols … ZD1, ZD2 : Surge absorption zener diode
PM-44/54 Tr1,Tr2 : PNP output transistor
Convergent
Reflective
PM2 SENSING CHARACTERISTICS (TYPICAL)

PM-K64(P) PM-L64(P)
Sensing position

Dark- Dark-
ON 9 mm 0.354 in ON


7 mm 0.276 in
2.6 mm ℓ
0.102 in

Beam
axis
Light- Light-
ON 0 1 2 3 4 ON 1 2 3 4
0.039 0.079 0.118 0.157 0.039 0.079 0.118 0.157
Operating point ℓ (mm in) Operating point ℓ (mm in)
Connector Built-in U-shaped Micro Photoelectric Sensor PM-64 SERIES
416

PRECAUTIONS FOR PROPER USE Refer to p.986~ for general precautions. FIBER
SENSORS

Cable extension LASER


• Never use this product as a sensing device SENSORS

for personnel protection. • Cable extension is possible up to an overall length of 100 PHOTO-
• In case of using sensing devices for m 328.084 ft with a 0.3 mm2, or more, cable. However, ELECTRIC
SENSORS
personnel protection, use products which since a voltage drop shall occur due to the cable MICRO
MICRO
PHOTO-
meet laws and standards, such as OSHA, extension, ensure that the power supply voltage at the PHOTO-
ELECTRIC
ELECTRIC
SENSORS
ANSI or IEC etc., for personnel protection end of the cable attached to the sensor or at the sensor SENSORS

applicable in each region or country. terminals is within the rating. AREA


SENSORS
Total cable length 100 m 328.084 ft
Connector +V SAFETY
attached cable Extension cable COMPONENTS
Make sure to connect terminals correctly as the Output + 5 to 24V DC
sensor does not incorporate a reverse polarity – ± 10 % PRESSURE
0V
protection circuit. Supply voltage:
4.5 V or more
SENSORS

Further, the output is not incorporated with a INDUCTIVE


short-circuit protection circuit. Do not connect it But, when the overall cable length, including the cable
PROXIMITY
SENSORS
directly to a power supply or a capacitive load. attached to the sensor, is as given below, there is no PARTICULAR
Faulty wiring may result in damage. need to confirm the voltage. USE
SENSORS

Conductor cross- SENSOR


OPTIONS
Mounting section area of Total cable length
extension cable WIRE-
• When fixing the sensor with screws, use M3 screws and SAVING
0.08 to 0.1mm2 Up to 5 m 16.404 ft
the tightening torque should be 0.5 N·m or less. SYSTEMS

Further, use small, round type plain washers (ø6 mm 0.2mm2 Up to 10 m 32.808 ft MEASURE-
MENT
ø0.236 in). SENSORS
0.3mm2 Up to 20 m 65.617 ft
STATIC
M3 screws CONTROL
DEVICES
Others LASER
Spring washer MARKERS
Plain washer
• Since the sensor is intended for
use inside machines, no special
( Outer diameter
ø6 mm
ø0.236 in
) countermeasures have been
taken against extraneous light.
Take care that extraneous light is
not directly incident on the beam
receiving section.
• Do not use during the initial transient time (50 ms) after
Wiring the power supply is switched on.
• If the sensor is used in a place having excessive dust, Selection
Guide
Connection method periodically clean the emitting and receiving sections with U-shaped
• Insert the connector attached cable Projection a dry, soft cloth.
[CN-14A(-R)-C□] in the connector • If there is a large surge generating equipment, such as, PM-64
part of this product as shown in the CN-14A(-R)-C□
motor, solenoid, electromagnetic valve, etc., in the vicinity PM-24
<Connector>
right figure. Housing: PAP-04V-S of the sensor, use a surge absorber on that equipment.
PM-44/54
Further, do not run the sensor cables along power lines
<Connector pin position>
(Manufactured by J.S.T.
Mfg. Co., Ltd. ) and use a capacitor between +V and 0 V, if required. Convergent
Reflective
Use the sensor after confirming that the surge has been PM2
eliminated.
Connector pin No. 1 2 3 4
1 2 3 4 Terminal designation +V Output 1 Output 2 0V

Disconnection method
• Pressing the projection of the connector attached cable,
pull out the connector.
Note: Take care that if the cable is pulled out without pressing the projection,
the cable may break.
417 Connector Built-in U-shaped Micro Photoelectric Sensor PM-64 SERIES

FIBER DIMENSIONS (Unit: mm in) The CAD data in the dimensions can be downloaded from the SUNX website: http://www.sunx.com
SENSORS

LASER
SENSORS PM-K64 Sensor PM-T64 Sensor
PHOTO- 26 13.7
ELECTRIC 1.024 0.539
SENSORS 3.5
20 0.138 7
MICRO
MICRO 0.787 0.276 3
PHOTO-
PHOTO- 0.118
ELECTRIC
ELECTRIC 7
Center of beam axis
SENSORS
SENSORS 0.276

AREA 2-ø3.2 ø0.126 mounting holes


SENSORS 7
Operation indicator 0.276
13.4 Operation indicator
0.528 (Orange) 6.8
SAFETY (Orange)
5 2.6 0.268 Beam axis width:
COMPONENTS 0.197 0.102
0.8 0.031 13.4
26 0.528
PRESSURE Beam axis Beam axis width: 5
9 1.024 2.6
SENSORS 0.354 Locking 3.2 0.8 0.031 0.197
13.8 0.102
23 part 0.126 0.543
INDUCTIVE 6.2 4.1
0.906 0.244
PROXIMITY 7.4 0.161 9 Beam axis
SENSORS 0.291 3.2 0.354
0.126 13
23
PARTICULAR
USE 3.7 (2.1
0.083 )
0.512
0.906
SENSORS 0.146 10.5
7.4 0.413
1.7 2-mounting oblong holes 0.291
0.067
SENSOR
OPTIONS
20
0.787
Connector attached cable CN-14A(-R)-C□ (Optional) Locking
part
( 2.1
0.083 )
1.6 20 2-mounting
0.063 0.787 Connector attached cable
WIRE- oblong holes CN-14A(-R)-C□ (Optional)
SAVING
SYSTEMS
MEASURE-
MENT
SENSORS
PM-L64 Sensor PM-Y64 Sensor
STATIC
CONTROL 26.2 2-ø3.5 ø0.138 mounting holes
DEVICES 1.031 7 3.5
20 0.276 0.138
1.7 0.067 3.5
3.7 0.146 0.787
LASER 0.138
MARKERS
7 7
Center of beam axis 0.276
15.7 0.276 22.7 Center of beam axis
0.618 3.2 2-mounting oblong holes 0.894
0.126 Operation indicator (Orange)
Operation indicator (Orange)
Locking part Locking part
(0.083
2.1
) Connector attached cable
12.8
0.504
CN-14A(-R)-C□ (Optional) ( 2.1
0.083 ) 12.8
Connector attached cable
CN-14A(-R)-C□ (Optional)
6.4 0.504
13.4 0.252
0.528 Beam axis width: 13.8 6.4
2.6 8.3 5 0.8 0.031 0.543 2.6 0.252 Beam axis width:
0.102 0.327 9 5
0.197 0.354 0.102 0.8 0.031
Selection 0.197
Guide 9 Beam axis Beam axis
15.5 0.354 2.5
U-shaped
PM-L64

U-shaped 0.610 15.5 12.9 0.098


7.2 PM-L64

0.610
0.283 0.508 6.5
PM-64 0.256
9 20
0.354 0.787 2-ø3.2 ø0.126 mounting holes
PM-24

PM-44/54
Convergent
Reflective PM-F64 Sensor PM-R64 Sensor
PM2
3 3
0.118 0.118
Beam axis and boss Beam axis and boss
7 7
0.276 0.276
Operation indicator (Orange) Operation indicator (Orange)
Center of beam axis Center of beam
and boss ø2.4
ø2.4 ø0.094 ø0.094 axis and boss
13.4 2.5 7 7 2.5 13.4
Beam axis width: 0.528 0.098 0.276 0.276 0.098 0.528 Beam axis width:
0.8 0.031 5 2.6 Center of beam Center of beam axis 2.6 5 0.8 0.031
0.197 0.102 axis and boss and boss 0.102 0.197

9
0.354
23 16.3 16.3 23
0.906 0.642 0.642 0.906 9
8.2 8.2 0.354
0.323 0.323

Locking part 7 ø3.2 ø0.126 7


ø3.2 ø0.126 Locking part
Connector attached cable
CN-14A(-R)-C□ (Optional)
( 0.083
2.1
) 0.276
14 mounting holes
mounting holes 0.276
14 (0.083
2.1
)
0.551 0.551 Connector attached cable
CN-14A(-R)-C□ (Optional)
Connector Built-in U-shaped Micro Photoelectric Sensor PM-64 SERIES
418

DIMENSIONS (Unit: mm in) The CAD data in the dimensions can be downloaded from the SUNX website: http://www.sunx.com FIBER
SENSORS

LASER
CN-14A-C□
□ CN-14A-R-C□ Connector attached cable (Optional) SENSORS

PHOTO-
L • Length L ELECTRIC
SENSORS
(1.378
35
) (1.969
50
) Model No. Length L MICRO
MICRO
PHOTO-
PHOTO-
ELECTRIC
(0.315)
8
(0.315)
8
CN-14A(-R)-C1 1,000 39.370
ELECTRIC
SENSORS
SENSORS
AREA
CN-14A(-R)-C2 2,000 78.740 SENSORS

CN-14A(-R)-C3 3,000 118.110


ø3.7 ø0.146 cable SAFETY
COMPONENTS
CN-14A(-R)-C5 5,000 196.850
PRESSURE
SENSORS

INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS

SENSOR
OPTIONS

WIRE-
SAVING
SYSTEMS
MEASURE-
MENT
SENSORS
STATIC
CONTROL
DEVICES

LASER
MARKERS

Selection
Guide
U-shaped

PM-64

PM-24

PM-44/54
Convergent
Reflective
PM2

Vous aimerez peut-être aussi