DATA SHEET Fire Sets FLA

DAYLIFF FLA packaged Fire Sets are specially designed to provide automatic supply to multiple hose reel
or sprinkler outlets for firefighting installations. Standard sets combine parallel duty diesel and electric
powered supply pumps to ensure serviceability in all conditions as well as a jockey pump to maintain
system pressure. Particular features include:-
l Individual electric motor and Lister diesel engine powered Ajax pumpsets providing standby supply
in the event of electrical power failure
l Separate automatic jockey pump to maintain system pressure and regulate main pump operation
l Bellows type pressure switch controlled operation providing progressive jockey pump, electric
pump and diesel pump starting at reducing cut-in pressure
l Low maintenance diaphragm type pressure vessel to regulate pump cycling.
l Integral control panel providing automatic parallel operation of the supply pumps and
incorporating electrical protection and a DC battery charging system
l Compact frame mounted design incorporating necessary valves and piping for simple site
installation.

Systems are designed to give their rated output at 5 Bar and three standard sizes are available, 40, 60
3
and 100 m /hr with the two pumpsets operating in parallel, 50% standby output being provided in the
event of electrical failure. For particular applications special designs incorporating different equipment
arrangements and specifications are available.

For all firefighting applications high levels of equipment performance and dependability are vitally
important for the protection of both lives and property. Dayliff FLA Fire Sets combine quality
components, all carefully matched for optimal operational efficiency with Davis and Shirtliff's
unmatched pumping expertise and competitive pricing to provide effective, reliable and easy to install
firefighting solutions.
SPECIFICATIONS
Supply Pumps: Dayliff single stage end suction pumps featuring gland packing seal and heavy duty bearings
constructed from heavy duty cast iron with bronze impellers. Pumps models are selected to meet the design pressure and
flow rates. Detail performance curves are available on request.
Diesel Engine: Lister TR naturally aspirated air-cooled diesel engines fitted with automatic electric start, engine
mounted 13.5l fuel tank and a dual 50Ah battery set.
Electric Motor: TEFC squirrel cage 2-pole 2900 rpm electric motors suitably rated for the pump load.
Jockey Pump: Grundfos CH4-60 horizontal multistage centrifugal pump fitted with 1kW electric motor. The pump is
set to maintain system pressure at 4.5Bar thus avoiding cycling of the service pumps due to minor system leakages.
Pressure Vessel: Varem 300 litre vertical pressure vessel fitted with butyl rubber diaphragm. The oversized vessel
volume limits jockey pump cycling frequency to a maximum of 10 starts per hour.
Piping: Suitably sized piping and fittings are provided for direct suction and delivery line connections including
necessary isolating gate valves, non-return valves on the system outlet. The limit of piping is shown in the schematic
drawing.
Control Panel: Control panel incorporating incoming mains isolator and MCB, voltage control relay, MCB and star-
delta starter for the main pump, MCB and DOL starter for the jockey pump, pump run/trip/no water indicators, 12-Volt
DC power circuit for the engine and a DC battery charging system. The panel is integrally mounted as standard, though
can be supplied loose for remote installation if required.
OPERATIONAL DATA
Nominal Diesel Pump Electric Pump
Flow (m 3
/hr) Piping Wt
Model
Parallel Single Pump Engine Power Speed Output Head Pump Motor Output Head Size (kg)
Duty Duty (kW) (rpm) (m3/hr) (m) (kW) (m3/hr) (m)
FLA 40 40 20 E32-26 TR1 8 2400 21 45 E32-20 7.5 23 55 2.5” 570
FLA 60 60 30 E40-26 TR2 11 2400 32 55 E40-20 11 36 55 3” 640
FLA 100 100 50 E50-26 TR2 17 2400 51 55 E50-20 15 61 55 4” 665
FLA 120 120 60 E65-26 TR3 22 2400 62 60 E65-20 30 72 65 4” 730

1660mm

Diesel Pump Set

Electric Pump Set 1800mm Control Panel


1850mm
Pressure Vessel

Jockey Pump

Pressure Vessel

Control Panel
1400mm

NB. Contents herein are not warranted. The right is reserved to amend specifications without notice.
AVAILABLE FROM WS104D - 08/11
KENYA ELDORET
TEL: (+254 53) 2061306, FAX: 2062335
KISUMU
TEL: (+254 57) 2024763, FAX: 2023103
ETHIOPIA TANZANIA
NAIROBI - HEAD OFFICE ADDIS ABABA DAR ES SALAAM
d&s@eld.dayliff.com d&s@ksm.dayliff.com
TEL: (+254 20) 6968 000 FAX: 557617 TEL: (+251 11) 5159341/44, FAX: 5159351 TEL: (+255 22) 2112515/6, FAX: 2112513
MOMBASA
d&s@dayliff.com
TEL: (+254 41) 2495920FAX: 2490868 UGANDA d&s@et.dayliff.com office@tzdayliff.com
NAIROBI - WESTLANDS d&s@msa.dayliff.com KAMPALA ARUSHA
TEL: (+254 20) 4446011/6, FAX: 4451038
MALINDI TEL: (+256 414) 346337/8, FAX: 346335
ZAMBIA TEL: (+255 27) 2502517/8, FAX: 2502516
westlands@dayliff.com LUSAKA office@ars.tzdayliff.com
TEL: (254 42) 210425, FAX: 210426 d&s@ug.dayliff.com
NAIROBI - DOWNTOWN TEL/FAX: (+260 211) 288010/1, 845010/1 ZANZIBAR
know H2Ow through experience TEL / FAX: (+254 20) 340102
d&s@mld.dayliff.com
DIANI
NAKESERO
TEL: (+256 392) 734633, FAX: 346335 lusaka@zm.dayliff.com TEL: (+255 24) 2234660/1, FAX: 2234664
d&s@dtn.dayliff.com Office@znz.tzdayliff.com
TEL: (254 40) 3202181, FAX: 3202182 d&s@ug.dayliff.com KITWE
www.dayliff.com THIKA
TEL / FAX: (+254 67) 20084/5
thika@dayliff.com
d&s@diani.dayliff.com
LAMU
GULU
TEL: (+256 471) 433041, FAX: 433040
TEL/FAX: (+260 212) 221747/67
kitwe@zm.dayliff.com
MWANZA
TEL: (+255 28) 2541971/2, FAX: 2541973
office@mwz.tzdayliff.com
TEL / FAX: (+254 20) 2651052/56 d&s@ug.dayliff.com NDOLA
NAKURU d&s@lamu.dayliff.com TEL/FAX: (+260 212) 610936/7
TEL: (+254 51) 2213248 FAX: 2212956
NYALI
MBARARA
TEL: (+256) 0753 940 080 ndola@zm.dayliff.com RWANDA
d&s@nkr.dayliff.com
TEL: (+254 20) 2443357 d&s@mbr..dayliff.com LIVINGSTONE KIGALI
KISII d&s@nyali.dayliff.com TEL/FAX: (+260 213) 320002 TEL: (+250) 504039, FAX: 504033
TEL: (+254 58) 30949, FAX: 30854
livingstone@zm.dayliff.com sales@dayliff.co.rw
d&s@kisii.dayliff.com

Vous aimerez peut-être aussi