www.edmi-meters.

com

Mk7B
– Class 1 and Class 2

Single Phase Smart Meter with


Disconnect Feature

Designed for residential and commercial use, the


Mk7B can operate in credit or prepayment mode.
It has a 100 Amp relay for remote connect/disconnect
of electrical services.

Key Features

Mk7B Factsheet | MKT-FS-034 Rev 02 Copyright © 2019 EDMI Limited


Mk7B
130mm (W)

- Class 1 and Class 2


180mm (H)
65mm (D)
Single Phase Smart Meter with
Disconnect Feature
Weight: 0.75kg

Standards and Compliance Real-time Clock • Energy, instantaneous Prepayment Software


• Accuracy (internal) within 15 readings, pulsing inputs as • Credit or debit operation • EDMI EziView software
• Class 1 and Class 2
seconds per month at 23˚C channel sources available for meter
(MID Class B and Class A) • Energy or currency based
• Ability to store average/ programming and reading
• IEC 62052-11,62053-21, • STS token compatible
Data Memory minimum/maximum values (Windows® compatible)
62053-23 (IEC 62055-31)
for interval duration • EDMI MultiDrive software
• AS 62052.11, 62053.21, • 2.1 MB of non-volatile • Multiple energy sources
62053.23 memory available for large scale
Time of Use • 8 rates per source
AMI and AMR solutions
Display • Up to 8 rates plus unified rate • External debt
Measurement (Windows® compatible)
• Large 7 segment display • Up to 32 separate import and prepayment x 2
• 1 phase 2 wire • Supported by many popular
export registers • Minimum charges, standing
• Screen ID is full third-party multi-vendor AMR
Voltage alphanumeric, 5 digits • Daily, weekly, monthly, yearly charges and emergency systems
and special days credit
• Nominal voltage: • Display digit size:
220V – 240V 9.3mm x 4.35mm • Up to 200 programmable • Configurable warnings
special days and indicators
• Operating range: • Up to 60 user-defined
• Up to 61 previous billing Environmental
176V – 276V screens of any meter
periods plus billing totals • Specified operating range:
• Withstand: 0 – 288V parameter
• Block or rolling maximum -25˚C to +60˚C
• Burden: IEC 62053-61 • Definable enunciators Communications
demand • Operating range limit:
compliant • Display available even • Up to 2 independently
without main power • Time of maximum demand -40˚C to +70˚C
working communication
Current • Energy, pulsing inputs • Storage range limit:
• Option for backlight ports:
• WC range: -40˚C to +80˚C
Calendar -O
 ptical port: FLAG (IEC
5/100A, 10/100A • Relative humidity:
62056-21) or ANSI Type 2
• WC limit: • Supports Daylight Saving
Measured Values (ANSI C12.18) Up to 75% mean, 95% non-
time
7000A for 3 cycles condensing for 30 days
• 1 element 4 quadrants - POD-based interface with
• Supports Gregorian or
• Burden: <0.5VA/phase • Ingress protection:
• Import/Export/Absolute Wh, Persian calendars options for Cellular, RF
Frequency varh and VAh and PLC communication IP54 (without suction)
• Fundamental Wh
Tamper Detection technologies
• 45Hz – 65Hz
• W, var, VA, Vrms, Irms
and Alarms
Relay • Provision for sealing with Protocol
• Power factor, frequency,
• 100A IEC 62055-31 conventional wire or plastic • EDMI command line
phasor angles
Annex C UC3 seals • DLMS
• Supports ripple control/AFLC
• Reverse current detection
Inputs/Outputs POD System
Power Quality Indication • Advanced tamper detection
Configuration • Total Harmonic Distortion and logging • Interchangeable PODs for I/O
• Built-in S0 of 27V, 27mA and communications
(THD) • Pre-programmed alarms for
maximum or Relay output of meter self-check • Sealable separately
• Sag/Swell
240V, 2A • Alarms trigger LEDs, • Robust
- 5 Cycle resolution
• 2 Programmable LED enunciators, relay outputs or TCP/UDP/IP/PPP GPRS
- Records time/date/phase
indicators duration/average and worst communications event Standard POD option includes:
• Programmable output excursion • Alarms are stored in event - GPRS modem with internal
pulse width: 1ms to 100ms - Programmable trigger levels logs antenna + ZigBee SEP

• Further I/O expansion • Option for magnetic tamper - Silver Spring Network Gen 4
Load Survey/Profile detection - FlexNet
via PODs
• Over 7200 days (20 years)
- Trilliant Gen 4
Battery storage (2 channels, 30 Security
- Ingenu
• Internal battery minute intervals) • Multi-level security
- HPGP PLC
• Option for external battery • Up to 32 channels and 2 (username and password
- Other combinations including
independent surveys including encrypted-login)
• Backup time of 10 years RS-232 and RS-485
without power (Lithium • Intervals programmable from • Up to 7 independent security
Battery) 1 to 60 minutes levels
• Up to 6 individual users

EDMI Limited www.edmi-meters.com


(Headquarters)
47 Yishun Industrial Park A, Singapore 768724
Tel: +65 6756 2938 Fax: +65 6756 0125
Email: marketing@edmi-meters.com
techsupport@edmi-meters.com
Copyright © 2019 EDMI Limited. All Rights Reserved. All trademarks are the property of their respective holders. EDMI’s Policy is one of continuous product development and the right is reserved to modify specifications contained herein without notice.

Vous aimerez peut-être aussi