PRODUCT
3
Innovative solutions
for industrial field.
Bonfiglioli Riduttori today is one of the top brands Bonfiglioli Vectron delivers products and services
in the power transmission industry. for completely integrated inverter solutions.
The company’s success is the result of a business These solutions complement Bonfiglioli’s power
strategy that relies on three fundamental factors: transmission and control offering to the industrial
know-how, innovation and quality. sector.
The complete range of Bonfiglioli brand
gearmotors offers excellent technical Since 1976, Bonfiglioli Trasmital’s know-how in
characteristics and guarantees the highest the power transmission industry has focused on
performance. Substantial investment and technical special applications offering 100% reliability in
expertise have enabled the company to achieve an the manufacturing of gearmotors for mobile
annual production output of 1600000 units using machinery.
completely automated processes.
This includes the full range of slew and wheel drive
Certification of the company’s Quality System applications and gearboxes for wind turbine pitch
by DNV and TÜV is proof of the high quality and yaw drive systems.
standards achieved. Today Bonfiglioli Trasmital stands at the
With the acquisition of the Vectron brand, forefront of the industry as a key partner to top
Bonfiglioli is now established as leader of the manufacturers worldwide.
industrial automation sector.
Solution Drive
7
Advanced technologies
for all industrial fields.
Bonfiglioli Active frequency inverters are powerful - easy mounting and connections, with a large
and innovative units specifically designed to number of panel mounting kits and easy
control electric motors in sophisticated automation disconnectable plug-in terminals
systems. - exceptional software configurability through a
Bonfiglioli Active range includes both single and streamlined, intuitive user interface
three phase units for mains voltages of 230 V or - versatile control, with very few configuration
400 V, ranging from 0.55 kW to 132 kW. parameters needed to drive synchronous and
Power ratings within Active range have been asynchronous, feedback and sensorless, braked
chosen to ensure a perfect match with Bonfiglioli and brakeless motors
motor ratings. The use of Active drives together - choice of motor control technologies, including
with Bonfiglioli electric motors exploits at best robust scalar control, vectorial sensorless control
technical synergy between these two product and accurate field-oriented feedback control:
series. Active frequency converters provide an adequate
Hardware flexibility is a fundamental feature level of accuracy and dynamics to satisfy the
of the Active series, and is achieved by means needs of a wide range of applications
of a generous selection of expansion and - speed and position synchronisation in “multi-
communication modules that can be used to drive” automation systems
“configure” inverters to suit specific application - extensive choice of accessories, all guaranteed
requirements. and tested with Active drives, including mains
Active 401/201 is a “System Drive”. Thanks to side inductors, EMC filters and braking resistors
integrated PLC functions and wide connectivity Active frequency inverters provide the perfect
with mostly used bus systems, Active 401/201 control solution for any application, from the
integrates seamlessly with a vast range of simplest machine automation systems to the most
automation solutions. complex control architectures granting perfectly
Other main features of Active series: repeatable high-tech results.
- extremely compact dimensions
- accurate motor control and silent running,
thanks to an 8 kHz switching frequency without
derating
8
Designation
ACT201 series
User interface
(blank) no user interface
Construction style KP500 programming control unit
A style with KP232 RS232 serial interface
standard cooling
C style with
cold-plate cooling
Communication modules
EMI filter (blank) no communication module
F internal filter CM-CAN CANopen communication module
(blank) no internal filter CM-PDP Profibus DP communication module
CM-232 RS232 serial communication module
CM-485 RS485 serial communication module
Size 1
05 0.55 kW
07 0.75 kW
Expansion modules
09 1.1 kW
(blank) no expansion modules
EM-SYS SYSTEMBUS expansion module
Size 2
EM-IO-... (01, 02, 03, 04) I/O expansion modules
11 1.5 kW
EM-ENC-... (01, 02, 03, 04, 05) ENCODER expansion modules
13 2.2 kW EM-RES-... (01, 02) RESOLVER expansion modules
15 3.0 kW (only 3 ph)
Size 3
18 4.0 kW (only 3 ph)
19 5.5 kW (only 3 ph)
Mounting kit
(blank) standard panel mounting kit
Size 4
MPSV thru-type mechanical installation kit without fan
21 7.5 kW (only 3 ph)
MDIN DIN rail mechanical installation kit
22 9.2 kW (only 3 ph) MNVIB antivibration mechanical installation kit
Series
ACT 201 inverter ACTIVE 1ph/3ph x 200-240 VAC +/- 10%
9
ACT401 series
User interface
(blank) no user interface
Construction style KP500 programming control unit
A style with KP232 RS232 serial interface
standard cooling
C style with
cold-plate cooling
Communication modules
(blank) no communication module
EMI filter CM-CAN CANopen communication module
F internal filter CM-PDP Profibus DP communication module
(blank) no internal filter CM-232 RS232 serial communication module
CM-485 RS485 serial communication module
Size 1 Size 5
05 0.55 kW 27 18.5 kW
07 0.75 kW 29 22 kW
Expansion modules
09 1.1 kW 31 30 kW
(blank) no expansion modules
11 1.5 kW EM-SYS SYSTEMBUS expansion module
Size 6
Size 2 33 37 kW EM-IO-... (01, 02, 03, 04) I/O expansion modules
12 1.85 kW 35 45 kW EM-ENC-... (01, 02, 03, 04, 05) ENCODER expansion modules
EM-RES-... (01, 02) RESOLVER expansion modules
13 2.2 kW 37 55 kW
15 3.0 kW 39 65 kW
18 4.0 kW
Size 7
Size 3 43 75 kW
19 5.5 kW 45 90 kW Mounting kit
21 7.5 kW 47 110 kW (blank) standard panel mounting kit
22 9.2 kW 49 132 kW MPSV thru-type mechanical installation kit without fan
MDIN DIN rail mechanical installation kit
Size 4 MNVIB antivibration mechanical installation kit
23 11 kW
25 15 kW
Series
ACT 401 inverter ACTIVE 3ph x 360-480VAC +/- 10%
10
Technical features
ACT201-05 ... ACT201-15 series
Power range up to 9.2 kW / 200-240 V three phase and
2.2 kW / 200-240 V single phase
Designation • EM-ENC-01: expansion for Line Driver
ACT201 Incremental Speed Sensor at DC 5 V (input signals
Size A, A, B, B, speed sensor signals repetition FFA,
From 0.55 to 1.1 kW / from 1.5 to 3.0 kW / from 4 FFA, FFB, FFB, 1xAI DC ±10 V, SYSTEMBUS)
to 5.5 kW / from 7.5 to 9.2 kW • EM-ENC-02: expansion for Line Driver
Incremental Speed Sensor at DC 5 V (input signals
Basic equipment A, A, B, B, 1xDI/DO, 1xAI DC (±10 V/± 20 mA),
• 200 - 240 V single-phase and three-phase (± 10%) 1xAO DC 0/4-20 mA, PTC, SYSTEMBUS)
/ 50 - 60 Hz (± 10%) • EM-ENC-03: expansion for Line Driver
• TN and IT mains compatible Incremental Speed Sensor (input signals A, A, B, B,
• overload capacity: 150% for 60s, 200% for 1s SYSTEMBUS). Speed sensor external power supply
• switching frequency 2 to 16 kHz • EM-ENC-04: expansion for Line Driver
• integral EMI filter to EN 61800-3 Incremental Speed Sensor at 5 V or 24 V with
• speed sensor connection zero signal (input signals A, A, B, B, Z, Z) 1xAI DC
• integral braking transistor ± 10 V, 1xAO DC ± 10 V, 1xRelay
• DC link connection • EM-ENC-05: expansion for Line Driver
• plug-in power terminals up to 4 kW Incremental Speed Sensor at 5 V or 24 V with
• plug-in programmable control terminals zero signal (input signals A, A, B, B Z, Z) 1xAI DC ±
• 6 digital inputs, 1 multifunction input 10 V, 1xAO DC ± 10 V, SYSTEMBUS
• 1 digital output, 1 multifunction output • EM-RES-01: expansion for Resolver (input signals
• relay output SIN, COS, REF resolver power supply, repetition
• freely selectable motor control: frequency output FFA, FFA, FFB, FFB, 1xAI (DC ±
sensorless control, sensorless field-oriented 10 V/± 20 mA)), SYSTEMBUS
control, • EM-RES-02: expansion for Resolver (input signals
field-oriented control with speed sensor SIN, COS, REF resolver power supply, repetition
• additional control and application systems frequency output FFA, FFA, FFB, FFB, frequency
available on request reference signal, 1xAI (DC ± 10 V/± 20 mA))
• motor temperature monitoring • EM-SYS: SYSTEMBUS expansion
• Standard installation kit
Development tools
Versions • VPlus: software for inverter programming
Cold-plate finish on request and monitoring on PC with Windows
Expansions operating system. Oscilloscope Function with 4
• KP500: removable control unit with parameter programmable traces
copy function Accessories
• KP232: removable RS232 interface adapter • Installation kit: various mechanical installation
• CM-232: RS232 interface kits (MPSV, MPVIB, MDIN) for different types of
• CM-485: RS485 interface enclosure mounting solutions
• CM-CAN: CANopen interface • Line choke: input filter for reducing current
• CM-PDP: Profibus-DP interface harmonics
• EM-I/O-01: I/O expansion (3xDI, 1xAI DC ± 10 V, • EMI filter: Input filter for EMC regulation
1xAO DC ± 10 V, 2xRelay, SYSTEMBUS) compliance
• EM-I/O-02: I/O expansion (3xDI, 1xAI DC ± 10 V, • dV/dt filter: output filter for dV/dt attenuation
1xAO DC ± 10 V, 1xPTC, 1xRelay, SYSTEMBUS) • Sine wave filter: output filter for long inverter/
• EM-I/O-03: I/O expansion (2xDI, 1xAI DC ± 10 V, motor cable
1xAO DC ± 10 V, 1xAO 0-20 mA, 1xRelay, 1xPTC, • Mains unit: PFC and network recovery of
SYSTEMBUS) regeneration energy
• EM-I/O-04: I/O expansion (1xDI/DO, 2xDI (PNP/ • Braking Resistor: external resistor for dynamic
NPN), 1xPTC/KTY, SYSTEMBUS) braking
11
Technical features
ACT401-05 ... ACT401-49 series
Power range up to 132 kW / 360-480 V three-phase
Hardware
• Range of voltage area: 200 - 240 V single-phase and • Speed sensor input for high dynamics applications
three-phase (± 10%), 360 - 480 V three-phase (±10%) requiring high precision speed and torque control
• TN and IT mains capable thanks to adaptation of • Integral braking transistor to limit DC bus voltage
basic devices in braking operation
• Integral EMI filter to EN 61800-3 on devices up to • Folding type attachment for extremely compact
9.2 kW installation
• DC link bus for energy exchange and central • DIN rail installation facility for units up to 4 kW
power feeding • Lateral installation facility for units up to 4 kW
• Plug-in power terminals up to 4 kW • Construction with high IP protection ratings
• Plug-in control terminals: ensures easy thanks to Cold-Plate option
connection and separation of control terminals • Supports master / slave operation in basic version
• Multifunction input: ensures high flexibility in for electronic gear applications and similar
defining the reference value using a range of • Optional expansion modules to extend control
different signal sources inputs and outputs
• Connection of digital inputs to software modules • Optional encoder modules to evaluate TTL & HTL
in the form of logic signals encoder and Resolver
• Multifunction output selectable from among a • Optional communication modules to connect to
vast range of parameters standard field bus networks and point-to-point
• Facility to connect digital outputs and connections
relay output to the software modules for • KP500 control unit with copy function to facilitate
programming requirements parameterisation and control operations
• Motor overtemperature protection by means of • KP232 interface adapter for high communication
thermo-evaluation flexibility via a serial protocol
Software
• Selectable motor control system: • Four data sets for parameterisation of various
- sensorless control operational behaviour modes
- sensorless field-oriented control • Parameter identification of the connected motor
- field-oriented control with speed sensor (FOC) (tuning) as a supplementary facility of the guided
- brushless motor commissioning function
• Coupling with various reference value sources on • Auto set-up of dependent parameters during
reference frequency channel and reference guided commissioning procedure
percentage channel • Synchronization function to catch a spinning motor
• Intelligent current limits for load-dependant • Auto-start after alarm or power loss
optimisation of operational behaviour • Automatic acknowledgement of selected faults
• Mains voltage monitoring enables programmable without motor switch-off (pre-alarm)
behaviour in the event of faults • Integrated PI control let to implement (for
• Use of kinetic energy in the drive system for example) pressure, volumetric flow or speed
power failure bridging or controlled motor control (with tacho generator)
stopping • Brake Control and Load Detection for lifting
in mains power loss conditions applications
• Motor phase monitoring to avoid stressing the • Programmable timer and logical functions
coupled load included in the software modules
• Speed sensor monitoring with continuous control • Flow control to optimise operational behaviour
of sensor signals • Continuous torque monitoring for control of
• Overload protection and automatic switching drive behaviour under load
frequency adaptation • Surge-free speed / torque control switch-over
• Motor circuit breaker for protection of the • System bus for transmission of parameter
connected motor settings, actual and nominal values
• Motor chopper function (reduces braking energy • Positioning from reference point with
without brake unit) programmable stopping behaviour
• Programmable starting and stopping behaviour • Stability control in synchronous tie applications
so the drive can be started, stopped, and • Memory of real mean and peak values
controlled down to standstill • Alarms video page and report generation with
• S-ramp for separately adjustable acceleration and adjustable limits and behaviour responses
deceleration ramps and for smooth speed • Alarm memory and environment
changes (jerk limitation)
• Motor potentiometer controlled via digital input,
control unit and communication interface
13
Storage conditions
• According to EN50178
Protection degree
• IP20
Electrical
Rated mains voltage
• ACT 201 in the range 184 ... 264 V
ACT 401 in the range 320 ... 528 V
Overload current
• 150% of rated current (200% for 0.25 and 0.37 kW)
Peak current
• 200% of rated current for most ratings
Electric protection
• Short circuit / Earth fault proof
Braking transistor
• Built-in on standard devices
14
Recommended rated motor power Pn kW 0.55 0.75 1.1 1.5 2.2 3.0
Rated motor current output In A 3.0 4.0 5.5 7.0 9.5 12.5
Overload current for 60 s Ipk A 4.5 6.0 7.3 10.5 14.3 16.2
Overload current for 1 s Ipk A 6.0 8.0 8.0 14.0 19.0 19.0
Nominal current 1 ph/N/PE; 2 ph/PE I A 5.4 7.2 9.5 13.2 16.5 16.5
General
Environment
General
Environment
Note: (0) = for protection classes higher than IP20 consult your local Bonfiglioli Drives Service Center
16
Recommended rated motor power Pn kW 0.55 0.75 1.1 1.5 1.85 2.2 3.0
Rated motor current output In A 1.8 2.4 3.2 3.8 4.2 5.8 7.8
Overload current for 60 s Ipk A 2.7 3.6 4.8 5.7 6.3 8.7 11.7
Overload current for 1 s Ipk A 3.6 4.8 6.4 7.6 8.4 11.6 15.6
Nominal current 3 ph/PE I A 1.8 2.4 2.8 3.3 4.2 5.8 6.8
General
Environment
Note: (0) = for protection classes higher than IP20 consult your local Bonfiglioli Drives Service Center
17
Rated motor current output In A 9.0 14.0 18.0 22.0 25.0 32.0
Overload current for 60 s Ipk A 13.5 21.0 26.3 30.3 37.5 44.5
Overload current for 1 s Ipk A 18.0 28.0 33.0 33.0 50.0 64.0
General
Short circuit /
- - Yes, unlimited
ground fault protection
Dimensions Std. A HxWxD mm 250 x 60 x 175 250 x 100 x 200 250 x 125 x 200
Cold Plate Opt. C HxWxD mm 250 x 85 x 140 250 x 125 x 144 250 x 150 x 144
Environment
Note: (0) = for protection classes higher than IP20 consult your local Bonfiglioli Drives Service Center
18
General
Environment
Note: (0) = for protection classes higher than IP20 consult your local Bonfiglioli Drives Service Center
19
General
Weight (approx.) m kg 20
Environment
Note: (0) = for protection classes higher than IP20 consult your local Bonfiglioli Drives Service Center
20
General
Weight (approx.) m kg 45 48
Environment
Note: (0) = for protection classes higher than IP20 consult your local Bonfiglioli Drives Service Center
21
Inverter Derating
Installation altitude
100 55
Cooling temperature
Output current %
85
45
60
40
20
Cooling temperature
Derating in relation to
installation temperature 100
2.5%/K above 40°C;
Output current %
Tmax = 55°C 80
63
40
20
0 10 20 30 40 50 55
Cooling temperature in °C
Mains voltage
Derating in relation to
power feeding voltage 100
0.22%/V beyond 400V;
Output current %
Vmax = 480V 83
63
40
20
Optional components
Thanks to the modularity of their hardware can be plugged into the inverter directly, while
components, ACTIVE frequency inverters are easily the cover must be removed in order to gain access
integrated in automation applications. Optional to plug-in sections B and C. If a communication
on-board modules are automatically recognised module is added to section B the perforated
by the inverter when present (plug and play) right part of the cover must be eliminated. Further
from the initialisation phase, and the internal information on installation and management
control functions of the unit are automatically of the optional modules is given in the specific
adapted accordingly. documentation (optional equipment user
The modules available for connector A (see figure) handbooks).
Hardware modularity
A) Interface module
Connection of optional control unit KP500,
serial interface adapter KP232, or the control
unit remotisation cable for accessory KPCMK
B) CM communication module
Connection panel for various communication
protocols:
• CM-232, RS232 interface
• CM-485, RS485 interface A
• CM-PDP, Profibus-DP interface
• CM-CAN, CANopen interface
• Other protocols on request
C) EM expansion module
Connection panel for adaptation of control
inputs and outputs to the various applications
on the basis of specific customer requirements:
• EM-IO, analog and digital inputs and outputs,
available in 4 variants
• EM-ENC, speed sensor interface, frequency
output and system bus, available in 5 variants
• EM-RES, resolver interface, frequency output B
and system bus, available in 2 variants
• EM-SYS, system bus for Systembus
communication (On request, system bus
combined with CM-CAN communication module)
• Other personalisable modules on request
The KP500 control unit is equipped with a Parameters Copy function that allows the
user to upload parametric values from the inverter to a non-volatile memory installed
in the KP500 device, allowing the same values to be subsequently downloaded to
another inverter.
The control unit makes it possible to set up the inverter for specific applications and
allows the display of the service values of physical and electrical parameters.
The inverter can also be controlled from the control unit for start/stop and frequency
reference increase/decrease commands. Since the control unit is not essential for
inverter operation it can be connected when the user considers it useful or necessary.
Control unit remote installation kit / KPCMK Handheld remote control unit
The KPCMK kit is used to remotely control the inverter
from the KP500 unit.
4 screws K 35 x 10 mm
Cut-out 92 x 92 mm
Interface / KP-232
Serial interface KP232 can be used as an alternative to control unit KP500. This connection enables
parameterisation, monitoring, setting management, inverter control and even commissioning from a
PC or laptop computer. The serial point-to-point connection between inverter and PC complies with
specifications for transmission between data terminals (DTE) and data communication equipment
(DCE), requiring, in this mode, a serial pin-to-pin cable with DB9 male connector on the inverter side.
The KP232 interface is compatible with lines no longer than 15 metres. The serial transmission protocol
ensures high data security and does not require handshake signals between computer and inverter.
The VPlus software application can be supplied as an accessory. This program, which runs in Windows,
is dedicated to the complete management of the ACTIVE inverter from a PC, including the functions
of commissioning and parameterisation, which calls for the presence of hardware interface KP232,
CM232 or CM485. The VPlus package also includes a digital Oscilloscope Function. The oscilloscope has
four traces configurable for inverter monitoring also with graphic capabilities.
Technical data
KP232
Plug-In
Active
RS232 line
PC/Notebook
26
RS232 / CM-232
serial communication
The optional CM-232 communication card enables RS232 serial connection of the ACTIVE
inverter to an external control device or PC to ANSI standard EIA/TIA-232E and CCITT V.28.
The standard defines the electrical and mechanical characteristics of serial connections
between data terminating equipment (DTE) and data communication equipment (DCE).
The serial interface, in the form of a DB9 plug, features DCE type pinouts.
The serial transmission protocol guarantees high data security and allows connection,
also without handshake signals, thereby reducing the required number of connection
lines to just three.
Maximum allowed distance between the various bus nodes (inverters) and the master
(PC, PLC) depends on the cable used and the selected transmission rate.
This option can be used as well for inverter programming and monitoring with VPlus
software.
up to 30m 19.2
up to 10m 115.2
CM-232 module
RS232 line
RS485 / CM-485
serial communication
The CM-485 communication module is designed for high speed data transmission over
long distances in industrial applications. RS485 bus supports data exchange among 30
nodes in a bidirectional 2-wires system.
The interface is based on a DB9 connector, following the standards for physical
transmission of data ITU V.11 and ANSI EIA/TIA-422B
CM-485 communication card includes the end-of-line terminating resistor that can be
activated or disconnected by means of an on-board dip switch.
The RS485 network address of the inverter is set by software parameters either via
KP500 control unit or by means of PC in serial communication with KP-232. The RS485
complies with ISO standard 1745 for code-bound data transmission. The standard data
exchange rate and monitoring functions can be set using VPlus software.
up to 12000m 4.8
up to 2000m 19.2
CM-485 module
RS485 line
RS485 / CM-485
serial and Modbus communication
Modbus communication
The communication module CM-485 allows to use the Modbus Communication profile
to be used. The communication profile can be easily changed to Modbus with a
parameter. Therefore a very inexpensive solution is available to integrate the Active
inverters in a Modbus Communication environment with the standard Active devices
and a standard module.
There are two profiles available. The Modbus RTU profile is well established and known
to the experienced Modbus user, which offers quick communication between different
devices. Additonally, Modbus ASCII is supported as well, which allows easy set up and
diagnosis of the communication between different devices.
The address range allows values in the range between 1 to 247.
up to 12000m 4.8
up to 2000m 19.2
DP / CM-PDP
Profibus Communication
Profibus DP interface fulfils fieldbus standard DIN 19245. This Profibus version, which
is optimized in order to provide excellent performance in terms of speed and low
connection costs, has been adapted for communication between automation systems
and decentralized peripheral devices.
Following “variable speed drive” profiles defined by Profidrive for electrical drive
technology are supported by CMP-DP: PPO1, PPO2, PPO3, PPO4.
CM-PDP interface supports different transmission rates in compliance with EN 50170
standard. The transmission rate automatically adjusts to the settings of the fieldbus
Internal dipswitch to enable the 220 Ω
master.
terminating burden resistor incorporated in
the module CM-PDP module is equipped with a DIP switch to activate end-of-line terminating
resistor, included into CM-PDP.
up to 1200m 93.75
up to 1000m 187.5
up to 400m 500
up to 200m 1500
up to 100m 12000
CM-PDPV1 module
DP line
CANopen/ CM-CAN
communication
The CM-CAN communication option with controller area network interface, complies
with ISO/DIS 11898 transmission standard. The pinout of connector DB9 is based on
the “CAN in Automation e.V.” specification, which allows the connection of up to 127
nodes in the network. The network node addresses are assigned via software. The
endburden resistor is activated by means of a DIP switch on the module. The end of
line terminating current transmission protocol complies with CANopen specifications
DS-301 V4.02. The maximum allowed distance between the bus nodes depends on the
cable used and the selected transmission rate. See table.
Internal dipswitch to enable the terminating
resistor incorporated in the module
up to 5000m 10
up to 2500m 20
up to 1000m 50
up to 800m 100
up to 500m 125
up to 250m 250
up to 100m 500
up to 25m 1000
CM-CAN module
CANopen line
Control system / PC
The EM-IO-01 expansion modules extends the number of the standard inputs and
outputs provided on the ACT inverter for connection of various applications.
Analog inputs and outputs can be available also with bipolar signals and must
therefore be configured with inverter parameters.
The supplementary digital inputs provided on the expansion module are electrically
equivalent to the standard inputs. The relay changer contact constitutes an alternative
for the activation of high power with respect to the relay output available as a
standard feature.
The SYSTEMBUS is available on two control terminals and supports easy control of
decentralised drive systems.
The module is equipped with a removable terminal board divided into two parts
(X410A and X410B) that are physically separated one from the other.
• 3 Digital inputs
• 2 Relay outputs
• 1 Analogue input
• 1 Analogue output
• DC 20 V output
• Systembus
Like the previously illustrated EM-IO-01, the EM-IO-02 expansion module extends the
standard inputs and outputs featured on ACT frequency inverters.
The EM-IO-02 module has a slightly modified layout compared to the -01 version,
featuring an input for a PTC thermal probe in place of one of the module relay
outputs.
The functions of all the other terminals are identical to the version illustrated above.
• 3 Digital inputs
• 1 Relay outputs
• 1 Analog input
• 1 Analog output
• DC 20 V output
• Motor PTC evaluation
• Systembus
The EM-IO-03 expansion module is another variant for the extension of I/O facilities of
ACTIVE frequency inverters.
• 2 Digital inputs
• 1 Relay outputs
• 1 Analog input
• 2 Analog output
• DC 20 V output
• Motor PTC evaluation
• Systembus
The EM-IO-04 expansion module is another variant for the extension of I/O facilities of
ACTIVE frequency inverters.
• 2 Digital inputs
• 1 Digital Port (input or output)
• DC 20 V output
• Motor PTC or KTY evaluation
• Systembus
The EM-ENC-01 expansion module extends the number of speed sensor inputs with
respect to the standard terminal board of the frequency inverter, and also increases the
number of configurable pulse outputs.
This module is able to manage TTL and HTL incremental speed sensors to standard EIA
RS422 (line driver) with 5-volt logic. The EM-ENC-01 speed sensor module is equipped
with connection terminals for signals A, A, B and B of the line driver speed sensor and
terminals for repetition output of the same signals (speed sensor emulation). This
makes it possible to create master-slave configurations between several separate units
using the output signals of one unit as the input signals of the next.
The DC +/- 10 V analog input can be used for the inverter frequency reference signal.
The same terminal board also provides a DC + 5 V (200 mA) power supply for the line
driver speed sensor.
Like the other EM expansion modules, the EM-ENC-01 features a Systembus interface.
The EM-ENC-02 speed sensor module extends the standard terminal board of the
inverter, providing an interface for line driver encoders with relative DC + 5 V power
supply.
The same module is equipped also with a DC 0 ... 20 mA and +/- 20 mA analog input
and a DC + 20 mA analog output, together with an input for a PTC thermal probe and
a digital port configurable as an input or output.
Also this module is equipped with a Systembus port.
The EM-ENC-03 extends the standard terminal board of the inverter, providing an
interface for line driver speed sensors.
Also this module is equipped with a Systembus port.
Unlike the other EM-ENC-XX modules, the EM-ENC-03 module is not equipped with a
power supply output for the speed sensor.
X410B.1 -
1 X410B.2 -
2
X410B.3 -
3
4 X410B.4 -
5 CAN-Low X410B.5 CAN-Low Systembus
6 CAN-High
X410B.6 CAN-High Systembus
7 GND
X410B.7 GND
The EM-ENC-04 speed sensor module extends the standard terminal board of the
inverter, providing an interface for line driver speed sensors with Z channel.
This module is able to manage TTL, HTL, or push-pull incremental speed sensors to
standard EIA RS422 (line driver). The EM-ENC-04 speed encoder module is equipped
with 6 control terminals for A, A, B, B direction signals and Z and Z zero signals
transmitted by the speed sensor.
The same module also features a ± 10 V and ± 20 mA analog input and a ± 10 V voltage
output in addition to a digital relay output.
The module also features two output voltages (+ 5 V and + 24 V) for the speed sensor
power supply.
The EM-ENC-05 speed sensor module extends the standard terminal board of the
inverter, providing an interface for line driver speed sensors with Z channel.
This module is able to manage TTL, HTL, or push-pull incremental speed sensors to
standard EIA RS422 (line driver). The EM-ENC05 speed encoder module is equipped
with 6 control terminals for A, A, B, B, direction signals and Z and Z zero signals
transmitted by the speed sensor.
The same module also features a ± 10 V and ± 20 mA analog input and a ± 10 V voltage
output in addition to a digital relay output.
It is also equipped with a SYSTEMBUS communication bus.
The EM-RES-01 angular position transducer module extends the standard functions
of the frequency inverter by providing a supplementary input for a resolver
(electromechanical absolute speed sensor).
Resolver gives the instantaneous motor shaft position value even at standstill, and its
angular position within a revolution.
EM-RES-01 provides 6 terminals for connection of the two sinØ and cosØ track signals
generated by the transducer and also carry the resolver power supply voltage.
The module EM-RES-01 also supplies an output signal emulating a digital incremental
speed sensor through the generation of squarewave signals A, A, B, B, which can be
used for shaft synchronisation of any connected slave inverters.
The EM-S1INA multifunction analog input (± 10 V or ± 20 mA) and a Systembus
communication port extend the standard functions of the ACT frequency inverter.
• Resolver evaluation
• Frequency repetition output without Zero-Pulse
• Analog input
• Systembus
3 SIN+ X410A.3
Resolver sinq signal input
4 SIN- X410A.4
5 COS+ X410A.5
6 COS- Resolver cosq signal input
X410A.6
7 A out
X410A.7 Channel A speed sensor emulation
EM-RES-02 angular position transducer module extends the standard functions of the
frequency inverter by providing a supplementary input for a resolver.
This module shares all the features of EM-RES-01 except for the emulation of the
encoder zero signal, which in this case replaces the Systembus port.
• Resolver evaluation
• Frequency repetition output with Zero-Pulse
• Analog input
Engineering software
VPlus for PC retrieval for the reverse procedure of downloading
VPlus is a software application for management to the inverter.
of Bonfiglioli ACTIVE and VCB inverters using a PC VPlus requires a PC running Windows 98/NT/2000/
connected to the drive by means of an RS232 or XP and an RS232 or RS485 standard serial port
RS485 serial interface. with DB9 connector, grounded to avoid problems
For this purposes the ACTIVE inverter must be of disturbance on signals exchanged between
equipped with the optional KP232 interface or inverter and computer.
with communication module CM232 or CM485. The menus / submenus structure provides
The program is a highly useful accessory in subdivision of parameters by uniform groups.
all phases of the application, from inverter The interface language can be English, Italian, or
commissioning to run-time monitoring. German.
The user interface features an ergonomic structure The VPlus program also provides the facility
that supports the user during programming, for modem connection for remote diagnostics
management, and monitoring, allowing storage operations on the inverter.
of data sets by saving them to file and subsequent
S3OUT
S2IND
3 S3OUT
Circuit I
breaker CM
3 S1OUT
Fref
ASM FC
t1 t2 t3 t4 t13 t12 t11 t15
Mech. Ta Tb Tc
brake
Motor brake (motor chopper) parameter P507 drive starting from an external signal (e.g. proximity
The Motor Chopper function (P507) allows switch). The reference point is acquired on the digital
efficient braking of drives with high flywheel loads inputs and the target position can be parameterised.
without requiring external components such as “Positioning from a reference point” can be
brake units or mains recovery devices. employed independently of the control configuration
(with/without speed sensor). Since it is possible to
Positioning (parameters from P458 to P464) select drive behaviour once the target position has
With “Positioning from a reference point” been reached, “Positioning from a reference point” is
(Parameters P458 to P464), users can position a also suitable for fully automatic drive systems.
SPS
Sensor
Motor
FU
Timer Functions (parameters P790 to P795) Delay times can be programmed in a range from
The system is equipped with two timers which are 10 ms up to 650 hours. Multiple operating modes
connected, in the standard configuration, to a permit the adaptation of the Timer function
digital input and a digital output but which can be to meet the requirements of a broad range of
associated, by means of programming, with the I/ applications.
Os and several internal functions.
Timer 1 83
73 - S4IND 158 - Timer 1
Change data set 1 70
P. 83
Timer 2 84
75 - Digital signal 1 159 - Timer 2
P. 84
46
ACT Systembus
The ACT frequency inverter systembus is an is based on CAN and is implemented along the
economical and powerful communication system lines of CANopen methods. The systembus has two
allowing the connection of up to 64 ACT inverters. SDO channels and three PDO channels.
Taking account of its characteristics, the systembus
PLC
System bus Master System bus Slave(s)
Active Active
Field bus Inverter Inverter
Control system / PC
Channel SDO1 allows access to the real parameters interfaced with the field bus. Channel SDO2 is used
and values of all the inverters in the systembus for connection of a PC display tool for Windows.
from an external control system (e.g. PLC, NC, This display tool allows parameterisation and
etc. ). For this reason the master inverter must be monitoring of the process on-line.
n* n* n*
Speed n Speed n Speed n
Controller Controller Controller
Master Slave Slave
Inverter Inverter Inverter
M M M
T T TT
Electronic Gear
Data can be exchanged between inverters with the slaves. This strategy makes it possible to obtain
very high speed and precision by means of the PDO an adjustable speed ratio between the master
channels. Data exchange can take place between and one or more slaves. In the case that speed
any of the inverters in the systembus. sensors are used on the master and on the slaves,
In the case of a master/slave control, nominal it is possible to implement a synchronous tie with
speed is transmitted from the master inverter to angular ratios that can be modified on-line.
47
Master/slave synchronisation
(X16 configurations)
Synchronisation of handling processes (e.g. conveyor belts) is one of the functions available with the
standard firmware.
Material transported
Master Slave
Sensor Sensor
There are several dedicated inputs for input, e.g. for alignment procedures.
synchronisation signals (electronic gear). For For functional control the current deviation
master-slave control it is possible to set angular between master and slave can be monitored. If
ratios with very high resolution. An offset can a programmable threshold value is exceeded an
be programmed between two conveyor belts. error signal can be generated by means of a freely
The synchronism regulator can be activated/ configurable digital output.
deactivated by means of a programmable digital
Master - Dividor
N Offset Alarm
Master l
+
Phase Discriminator
+
Slave N
l
Slave - Dividor
f
X
f
PI-Controller
Mounting
A wide range of mechanical accessories is Types of mounting kits
available for ACT Series frequency converters, to The drive is supplied complete with a standard
make installation extremely easy in all sorts of installation kit for fixing to an electrical cabinet
application. mounting panel.
In standard mountings the unit can be installed 3 different optional installation kits are available
directly on the mounting plate or through-the- on request.
wall. A vibration-proof mounting variant and
a standard DIN bar mounting variant are also MPSV
available. Thru-type assembly for higher protection classes
The range of mounting variants also includes an or enhanced cooling characteristics
optional support with shielded brackets, so that MNVIB
the right solution for all possible needs can always Anti-vibration mounting for installations on
be found. machines that generate significant vibrational
Installations are practically identical for all sizes, stress
so the examples shown below can be taken as MDIN
representative solutions and ideal for all installers DIN rail assembly for fast and modular
seeking a mechanically simple, compact installation installation / coupling
solution.
49
Size 1
Inverter Bonfiglioli Mounting Description
Standard assembly B A B
MPSV1
MNVIB1
MDIN1 A A B
B
50
Size 2
Inverter Bonfiglioli Mounting Description
Standard assembly
MPSV2 A A B
MNVIB2 A
A B
MDIN2 A
A B
B
51
Size 3
Inverter Bonfiglioli Mounting Description
Standard assembly A
A B
MPSV3 A
A B
MNVIB3 A
A B
B
52
Size 4
Inverter Bonfiglioli Mounting Description
Standard assembly A
A B
MPSV4
MNVIB4 A
A B
B
53
Size 5
Inverter Bonfiglioli Mounting Description
Standard assembly A
A B
MPSV5
MNVIB5 B A B
A
54
Size 6
Inverter Bonfiglioli Mounting Description
Standard assembly A
A B
MPSV6
MNVIB6 A
A B
B
55
Size 7
Inverter Bonfiglioli Mounting Description
Standard assembly
A
A B
MPSV7
56
Input filter
Why an input filter? Line choke
An Input Filter is a filtration device to be installed - Line chokes are not mandatory: their use
up-line from the frequency inverter and down-line depends on the system engineer’s need to reduce
from the power feeding contactor. harmonic distortion in the short circuit point, and
The AC/DC rectifier at the inverter input generates the need to reinforce the action of the EMI filter.
harmonic disturbance on the absorbed current A line choke is normally used if the mains short
and returns disturbance generated by switching circuit power is lower than 1%.
components towards the mains. - A line choke is recommended for the ACU201 Line choke
This harmonic current causes voltage distortions on and ACU401 frequency inverter series in the
the mains resulting in electromagnetic interference presence of high continuous input current
phenomena. required by the application, in order to increase
This harmonic distortion is reduced by means of the lifetime of the electrolytic capacitors.
line chokes, while disturbance is countered with - A line choke is always required in single and
EMI filters (attenuation of EMI voltages) such as two-phase operation of the ACU201 frequency
those described below. inverters.
The use of input filters reduces the inverter
input voltage. If required, these filters should be
installed up-line from the inverter in the following EMI filter
order: - An EMI filter can be used in order to achieve
1. Mains supply Class “A” (groups 1, 2) or Class “B” interference
2. Line choke suppression
3. EMI filter - The EMI filter is available in a low leakage
4. Inverter current version for special applications.
- The EMI - filter is part of the standard outfit in sizes
of up to 4.0 kW and it is supplied as an optional for
higher sizes in an internal (up to 7.5 kW) or external
(above 7.5 kW) version.
Power
feeding line
ACTIVE inverter - Line choke / EMI filter combination
Mains Cable Length < 10 m < max* < 10 m < max* < 10 m < max*
ACT 1
Standard external choke external choke external filter external choke external filter
(standard internal filter)
EMI filter
ACT 2
Standard external choke external choke external filter external choke external filter
(standard internal filter)
internal filter internal filter internal filter internal filter internal filter
ACT 3 or or + + + external filter
external choke external choke external choke external choke external choke
external filter
ACT 4 external choke external filter external filter external filter external filter +
external choke
external filter
ACT 5 external choke external choke external filter external filter external filter +
external choke
ACT 6 external choke external choke external filter external filter external filter external filter
Line choke
The simplest way of reducing high harmonic components and hence reactive power
is connecting a choke in series on the mains side of the inverter. Depending on the
system, reactive power consumption can be reduced by approximately 20% of the
figure without line choke.
The line choke increases inductance towards the mains. Mains feed line choke can
be regarded as sufficient if short-circuit power is from 20 to 40 times higher than the
inverter nominal output.
The inverter is suitable for connection to public or industrial mains supplies in
compliance with technical data. If the supply mains transformer output is ≤ 500 kVA,
the optional mains choke is needed only if specified in the inverter technical data. The
other inverters are suitable for the connection to the mains without a mains choke
with relative impedance ≥ 1%. If it is desired to connect more than one inverter, use
the sum of the nominal outputs as a basis.
Since experience has shown that the nominal short circuit power on the inverter
connection point is often unknown, BONFIGLIOLI recommends the use of mains chokes
with 4% voltage drop.
The relative short circuit voltage equivalent to a 4% voltage drop represents the
percentage of the nominal voltage at which a current equal to rated current flows in
the case of a short circuit.
The European reference standard for harmonics is EN 60 555, while in the US and
Canada systems must comply with standard IEEE 519 and various generic national
regulations.
Line choke
Dimensions
PE
c
d
n2 n1
a b
[A] [W]
ACT 201-05 LCVS006 6 8.0
Line choke
Dimensions
LCVT004 ... LCVT025 LCVT034 ... LCVT250
U1 U2 V1 V2 W1 W2
PE
U1 U2 V1 V2 W1 W2
c
c
n2 n1 n2 n1
a b a b
ACT 201-05
LCVT004 4 7.32 20
ACT 201-07
ACT 201-21
LCVT034 34 0.86 85
ACT 201-22
60
Line choke
Technical data Bonfiglioli frequency inverter – Line choke combination, 3x400V~
EMI filters
Because of their intrinsic characteristics, all frequency and for installations where conformity to the stricter
inverters often generate undesired high frequency requirements of class B is necessary. The two series
voltages generally referred to as “interference”. differ both in construction and power range.
Mains filters are installed to reduce this interference. The first set of filters are “backplate filters or foot
Within the European Union reference standard EN print”. They are available in sizes 7 to 40 A (suitable
EN61800-3 defines the thresholds for electromagnetic for Active frequency inverters up to size 4), and allow
interference for different classes of equipment. the frequency inverter to be installed on board the
Active Series frequency inverters up to size 9.2 kW can filter itself. The second series of filters are “book
be ordered with a built-in EMI filter conforming to filters”. They cover all other Active sizes up to 130
the requirements of the standard for “class A – group A and are designed for installation on the same
2” environments. mounting panel alongside the drive.
Two series of external interference filters are Mains filters with very low dispersion currents are
available for larger size Active frequency inverters available upon request for specific applications.
L1 L1
L2 L2
L3 L3
PE PE
L1 L1
L2 L2
L3 L3
PE PE
62
ACT 201-05
ACT 201-07
ACT 201-09
1 ACT 401-05
ACT 401-07
ACT 401-09
FTV007B 8 5 10 1.5
ACT 401-11
ACT 201-11
ACT 401-12
2 ACT 401-13
ACT 401-15
ACT 401-18
ACT 401-19
3 FTV018B 18 1.2 10 3.5
ACT 401-21
ACT 401-23
4 FTV040B 40 1.2 10 3.5
ACT 401-25
63
A
M
D
E
F
A B
K
G
L1
L2
J
H
A
EMI filter A B C D E F G H J K L1 L2 M
[mm]
FTV007B 351 62 45 200±10 160±10 33 45±0.2 340±0.3 315 5.5 240±0.2 280±0.2 7
A A
U2 V2 W2
L1
M6
D
U1 V1 W1
L2
A
H
M6
K C
B
EMI filter A B C D G H K L1 L2
[mm]
C
L
J
H
A K
F
G
EMI filter A B C D E F G H I J K L
[mm]
FTV007A 190 40 70 160 180 20 4.5 1 22 M5 20 29.5
FTV016A 250 45 70 220 235 25 5.4 1 22 M5 22.5 29.5
FTV030A 270 50 85 240 255 30 5.4 1 25 M5 25 39.5
FTV055A 250 85 90 220 235 60 5.4 1 39 M6 42.5 26.5
FTV075A 270 80 135 240 255 60 6.5 1.5 39 M6 40 70.5
FTV100A 270 90 150 240 255 65 6.5 1.5 45 M10 45 64
FTV130A 270 90 150 240 255 65 6.5 1.5 45 M10 45 64
FTV180A 380 120 170 350 365 102 6.5 1.5 49.5 M10 60 47
Dimensions FTV250A
A B
D K1 K1
C
I2
I1
M10
H K2
J J
E
F
EMI filter A B C D E F G H I1 I2 J K1 K2
[mm]
FTV250A 482 140 140 380 168 155 6.5 1.5 62 100 120 40 50
66
Braking resistors
Connection diagram
RB
Motor
U
+ Ug M
V
W 3~
L1
L2
L3 Bch
- Ug
Connection terminals
The Rb1 and Rb2 braking resistor terminals on Active frequency inverters are located on the
X2 power output terminal strip. Access to these terminals on size 1 and 2 units is made even
easier by the use of disconnectable power terminal strips. Refer to the manual provided with
your frequency inverter for further details on materials and connection methods.
Rb Rb
Rb1 Rb2 Rb1 Rb2
T1 T2 T1 T2
67
Braking resistors
Active drive combination chart power. Contact your nearest Bonfiglioli Drive Centre
These charts show recommended combinations for for particularly heavy-duty braking applications or if
each model in the Active range, and specify the you need to customise a product.
corresponding duty cycles on the basis of rated drive
kW Ohm [W]
ACT 201-05 0.55 BR 160/100 100 160 29%
USA Brazil Spain South Africa India Singapore Vietnam Australia New Zealand
HEADQUARTERS
Bonfiglioli Riduttori S.p.A.
Via Giovanni XXIII, 7/A
40012 Lippo di Calderara di Reno
Bologna (Italy)
tel: +39 051 647 3111
fax: +39 051 647 3126
bonfiglioli@bonfiglioli.com
www.bonfiglioli.com VE_CAT_ACT_STD_ENG_R00_1