Vous êtes sur la page 1sur 7

M S C

TIA/EIA-568-B.3 & ISO/IEC


Ed2.0 Fiber Budget Calcul
Specifications
Fiber Loss Budget Calculator

M C
Cable Attenuation
● Meters M Source Cable
850nm 62.5/125 Multimode
Feet
1300nm 62.5/125 Multimode

S.. F.
850nm 50/125 Multimode
1300nm 50/125 Multimode
1310nm ISP Singlemode
● Multimode 850nm 1550nm ISP Singlemode
1310nm OSP Singlemode
Multimode 1300nm
1550nm OSP Singlemode

Connector Mated Pair Loss


● Singlemode ISP .75dB each pair
Multimode
Singlemode OSP
0.00 dB Splice Loss
Singlemode (Mechanical/Fusion)
0.000 dB .30dB each splice
8-B.3 & ISO/IEC 11801
er Budget Calculation
pecifications

able Attenuation
TIA/EIA ISO/IEC
3.5dB/km 3.75dB/km
1.5dB/km 1.5dB/km
3.5dB/km 3.75dB/km
1.5dB/km 1.5dB/km
1.0dB/km 1.0dB/km
1.0dB/km 1.0dB/km
.5dB/km .5dB/km
.5dB/km .5dB/km

ctor Mated Pair Loss


.75dB each pair

Splice Loss
Mechanical/Fusion)
.30dB each splice
Conduit Fill Capacity Table

Conduit Sizing Reference


Conduit Fill Calculator SAE Measurements* Metric Measurement
Internal
Inches Trade Area Metric
<= Enter measurement type Size
Diameter
(in2) Designator
Meters
(in)

3/4 (21) <= Enter conduit size 3/4 0.82 0.53 21


1 (27)
1-1/4 (35) 1 1.05 0.87 27
1-1/2 (41)
2 (53) <= Enter number of conduit bends 1-1/4 1.38 1.50 35
2-1/2 (63) In <= Enter actual cable O.D. 1-1/2 1.61 2.04 41
3 (78)
3-1/2 (91) 0 <= Number of cables allowed in conduit* 2 2.07 3.37 53
4 (103)
2-1/2 2.47 4.79 63
Inches: Milimeters: .00 mm 3 3.07 7.40 78
To convert milimeters to Inches use the following table: 3-1/2 3.55 9.90 91
Milimeters: Inches: .00 in 4 4.03 12.76 103
*Per ANSI C80.3-2005
* Calculations based upon 40% initial fill

The Siemon Company Confidential 09/03/2019 Page 3


Conduit Fill Capacity Table

Conduit Sizing Reference


Metric Measurements*
Internal
Area
Diameter
(mm2)
(mm)

20.8 340
26.7 560
35.1 965
40.9 1314
52.6 2173
62.7 3088
80.0 5027
90.2 6390
102.4 8235

The Siemon Company Confidential 09/03/2019 Page 4


Conduit Fill Capacity Table

Cable Tray Fill Calculator


Enter Measurement Type here
Inches
Millimeters
In <= Enter actual cable O.D.

In <= Enter tray height

In <= Enter tray width

0 <= Number of cables allowed in tray*

* Calculations based upon 50% fill

The Siemon Company Confidential 09/03/2019 Page 5


M... A...
Open Office Work Area Cord Calculator

C... W..
● Meters
M
Feet

● Unshielded UTP
20 M
ScTP

Maximum Work Area Cord UTP is 20m (66ft)

Maximum Work Area Cord ScTP is 15m (50ft)


M... A... Backbone Patchcord Calculator

C... M..
● Meters
M
Feet

● Unshielded UTP
25 M
ScTP

Maximum Backbone Combined Patch Cord UTP is 25m (82ft)

Maximum Backbone Combined Patch Cord ScTP is 20m (66ft)