Vous êtes sur la page 1sur 58

Sales Network

Beijing

Tel: 010-62642226
Chengdu

Tel: 028-83230557
Guangzhou

Tel: 020-87501601
Hangzhou

Tel: 0571-89901020
Jinan

Tel: 0531-86117674
Nanjing

Tel: 025-86644513
Shanghai

Tel: 021-61209211
Shenyang

Tel: 024-24150857
Shenzhen

Tel: 0755-83291934

Tel: 0755-83687772

Tel: 0755-83682454
Suzhou

Tel: 0512-68052622
Wuhan

Tel: 027-82844744
Xian Changsha

Tel: 029-85222109 Tel: 0731-85261948


Hefei Zhengzhou

Tel: 0551-4677178 Tel: 0371-55917207

Headquarter Workshop Warehouse Meeting Room


Europe Asia
Belarus Bangladesh
Belgium Egypt
Bosnia & Herzegovina Hong Kong
Czech Republic India
Denmark Indonesia
Finland Iran
France Israel
Germany Japan
Greece Korea
Hungary Macao
Ireland Malaysia
Italy Pakistan
Latvia Philippines
Luxembourg Singapore
Netherlands Taiwan
Norway Thailand
Poland United Arab Emirates
Portugal Vietnam
Romania
Russia North America
Slovenia Canada
Spain Mexico
Sweden United States
Switzerland
Turkey South America
UK Argentina
Ukraine Bolivia
Brazil
Oceania Chile
Australia Colombia
New Zealand Cuba
Ecuador
Africa Paraguay
Benin Uruguay
Nigeria
South Africa
Tunisia

Electronica, Munich ExpoElectronica, Moscow

ElectronicAsia, Hong Kong China Electronics, Shanghai


Factory

Lobby

Important Projects

Automatic Insertion Wave Soldering ICT In-Circuit Test


R&D Center Product Development EMI EMI Test

EMS EMS Test Environmental Test

Company Profile

ATE Automated Test Hi-pot Test Constant Temp. Burn-in Final Test
15W~150W Single Output M2 Series
15~150W Single Output M2 Series

Features:
Miniature size, high power density
Universal AC input / full range (HF150W-SMF, AC input range
selected by switch)
High reliability
100% full load burn-in test
Protections: overload/ over voltage/ short circuit
5 years limited warranty

AC input voltage range ................... 88~264VAC (HF15~100W-SSM) 50W Single Output 99 x 97 x 36(mm) weight: 0.28kg, 42pcs/CTN
85~132/ 170~264VAC selected by switch
(HF150W-SMF) Model DC Output Load regul. R&N Efficiency
Input frequency .............................. 47~63Hz
HF50W-SSM-3.3 3.3V 10.0A 0.5% 80mV 72%
Inrush current .................................. cold start, 20A/115V, 40A/230V
Input leakage current ...................... 1mA/ 230VAC HF50W-SSM-5 5V 10.0A 0.5% 80mV 80%
Line regulation (full load) ................. 0.5% HF50W-SSM-12 12V 4.2A 0.5% 120mV 82%
Output voltage adjust range ........... 10% HF50W-SSM-24 24V 2.2A 0.5% 150mV 85%
HF15~75W-SSM:
Output overload protection ............. 105~150%, hiccup mode, auto recovery HF50W-SSM-48 48V 1.1A 0.5% 150mV 86%
HF100W-SSM: * 3.3~48VDC output all available.
Output overload protection ............. 105~150%, shut off, re-power on to recover
HF150W-SMF:
Output overload protection ............. 110~130%, shut off, re-power on to recover
HF15~25W-SSM:
Output over voltage protection ....... clamping by zenor diode 75W Single Output 129 x 98 x 40(mm) weight: 0.42kg, 42pcs/CTN
HF35~100W-SSM, HF150W-SMF:
Output over voltage protection ....... 115~150%, shut off, re-power on to recover Model DC Output Load regul. R&N Efficiency
Withstand voltage ........................... I/P -O/P: 3.0KVAC/1min
HF75W-SSM-5 5V 12.0A 0.5% 80mV 73%
I/P -F/G: 1.5KVAC/1min
O/P-F/G: 0.5KVAC/1min HF75W-SSM-12 12V 6.0A 0.5% 120mV 82%
Rise time ......................................... 50ms@full load (typical) HF75W-SSM-24 24V 3.2A 0.5% 150mV 84%
Hold up time .................................... 20ms@full load (typical)
HF75W-SSM-48 48V 1.6A 0.5% 150mV 85%
Operating temperature ................... -20 ~+70 (refer to the derating curve)
Safety standards ............................ meet GB4943, UL60950, EN60950 * 5~48VDC output all available.
EMC standards ............................... meet GB9254, EN55022 classB, EN55024
EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11
Cooling method ............................... convection
100W Single Output 160 x 98 x 39(mm) weight: 0.56kg, 36pcs/CTN

Model DC Output Load regul. R&N Efficiency


15W Single Output 62.5 x 51 x 28(mm) weight: 0.13kg, 99pcs/CTN
HF100W-SSM-5 5V 16.0A 0.5% 100mV 75%
Model DC Output Load regul. R&N Efficiency HF100W-SSM-12 12V 8.5A 0.5% 120mV 82%
HF15W-SSM-5 5V 3.0A 0.5% 80mV 76% HF100W-SSM-24 24V 4.5A 0.5% 150mV 82%
HF15W-SSM-12 12V 1.3A 0.5% 120mV 82% HF100W-SSM-48 48V 2.3A 0.5% 150mV 83%
HF15W-SSM-24 24V 0.625A 0.5% 150mV 83% * 5~48VDC output all available.
HF15W-SSM-48 48V 0.33A 0.5% 150mV 83%
* 5~48VDC output all available.

150W Single Output 199 x 98 x 39(mm) weight: 0.66kg, 28pcs/CTN

Model DC Output Load regul. R&N Efficiency


25W Single Output 78 x 51 x 28(mm) weight: 0.18kg, 99pcs/CTN
HF150W-SMF-5 5V 25.0A 0.5% 100mV 80%
Model DC Output Load regul. R&N Efficiency HF150W-SMF-12 12V 12.5A 0.5% 120mV 84%
HF25W-SSM-5 5V 5.0A 0.5% 80mV 78% HF150W-SMF-15 15V 10.0A 0.5% 120mV 84%
HF25W-SSM-12 12V 2.1A 0.5% 120mV 82% HF150W-SMF-24 24V 6.5A 0.5% 150mV 85%
HF25W-SSM-24 24V 1.1A 0.5% 150mV 85% HF150W-SMF-48 48V 3.1A 0.5% 150mV 87%
HF25W-SSM-48 48V 0.57A 0.5% 150mV 85% * 5~48VDC output all available.
* 5~48VDC output all available.

Send inquiry now!


35W Single Output 98.5 x 82x 35(mm) weight: 0.25kg, 60pcs/CTN

Model DC Output Load regul. R&N Efficiency


HF35W-SSM-3.3 3.3V 7.0A 0.5% 80mV 71%
HF35W-SSM-5 5V 7.0A 0.5% 80mV 74%
HF35W-SSM-12 12V 3.0A 0.5% 120mV 81%
HF35W-SSM-24 24V 1.5A 0.5% 150mV 82%
HF35W-SSM-48 48V 0.8A 0.5% 150mV 85%
* 3.3~48VDC output all available.
35W~125W Dual Output M2 Series
35W Dual Output M2 Series 65W Dual Output M2 Series
Miniature size, high power density Miniature size, high power density
Universal AC input / full range Universal AC input / full range
High reliability High reliability
Protections: overload/ over voltage/ Protections: overload/ over voltage/
short circuit short circuit
5 years limited warranty 5 years limited warranty
F6025 98.5 x 82 x 35(mm) F603 129 x 98 x 40(mm)

AC input voltage range ................... 88~264VAC (124~370VDC) AC input voltage range ................... 88~264VAC (124~370VDC)
Input frequency .............................. 47~63Hz Input frequency .............................. 47~63Hz
Inrush current .................................. cold start, 20A/115V, 40A/230V Inrush current .................................. cold start, 20A/115V, 40A/230V
Input leakage current ...................... 1mA/ 230VAC Input leakage current ...................... 1mA/ 230VAC
Load regulation ................................ V1: 0.5%, V 2: 10% Load regulation ................................ V1: 0.5%, V2: 10%
Output voltage adjust range ........... V1: 5% of rated output voltage Output voltage adjust range ........... V1: 5% of rated output voltage
Output overload protection ............. 110~150%, hiccup mode, auto recovery Output overload protection ............. 110~150%, hiccup mode, auto recovery
Output over voltage protection ....... 115~150%, shut off, re-power on to recover Output over voltage protection ....... 115~150%, shut off, re-power on to recover
Withstand voltage ........................... I/P -O/P: 3.0KVAC/1min Withstand voltage ........................... I/P -O/P: 3.0KVAC/1min
I/P -F/G: 1.5KVAC/1min I/P -F/G: 1.5KVAC/1min
O/P-F/G: 0.5KVAC/1min O/P-F/G: 0.5KVAC/1min
Rise time ......................................... 50ms@full load (typical) Rise time ......................................... 50ms@full load (typical)
Hold up time .................................... 20ms@full load (typical) Hold up time .................................... 20ms@full load (typical)
Operating temperature ................... -20 ~+50 Operating temperature ................... -20 ~+50
Safety standards ............................ meet GB4943, UL60950, EN60950 Safety standards ............................ meet GB4943, UL60950, EN60950
EMC standards ............................... meet GB9254, EN55022 classB, EN55024 EMC standards ............................... meet GB9254, EN55022 classB, EN55024
EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11 EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11
Cooling method ............................... convection Cooling method ............................... convection

Model DC Output R&N Efficiency Model DC Output R&N Efficiency


5V 0.3~5.0A 80mV 5V 0.3~8.0A 80mV
HF35W-DSM-A 80% HF65W-DSM-A 79%
12V 0.2~1.0A 120mV 12V 0.2~4.0A 120mV
5V 0.3~4.0A 80mV 5V 0.3~8.0A 80mV
HF35W-DSM-B 82% HF65W-DSM-B 81%
24V 0.2~1.3A 150mV 24V 0.2~3.0A 150mV

50W Dual Output M2 Series 125W Dual Output M2 Series


Miniature size, high power density Miniature size, high power density
Universal AC input / full range AC input range selected by switch
High reliability High reliability
Protections: overload/ over voltage/ Protections: overload/ over voltage/
short circuit short circuit
5 years limited warranty 5 years limited warranty
F605SM 99 x 97 x 36(mm) F610 199 x 98 x 39(mm)

AC input voltage range ................... 88~264VAC (124~370VDC) AC input voltage range ................... 88~132/ 176~264VAC selected by switch
Input frequency .............................. 47~63Hz Input frequency .............................. 47~63Hz
Inrush current .................................. cold start, 20A/115V, 40A/230V Inrush current .................................. cold start, 20A/115V, 40A/230V
Input leakage current ...................... 1mA/ 230VAC Input leakage current ...................... 1mA/ 230VAC
Load regulation ................................ V1: 0.5%, V 2: 10% Load regulation ................................ V1: 0.5%, V2: 10%
Output voltage adjust range ........... V1: 5% of rated output voltage Output voltage adjust range V1: 5% of rated output voltage
Output overload protection ............. 110~150%, hiccup mode, auto recovery Output overload protection ............. 110~130%, shut off, re-power on to recover
Output over voltage protection ....... 115~150%, shut off, re-power on to recover Output over voltage protection ....... 115~150%, shut off, re-power on to recover
Withstand voltage ........................... I/P -O/P: 3.0KVAC/1min Withstand voltage ........................... I/P -O/P: 3.0KVAC/1min
I/P -F/G: 1.5KVAC/1min I/P -F/G: 1.5KVAC/1min
O/P-F/G: 0.5KVAC/1min O/P-F/G: 0.5KVAC/1min
Rise time ......................................... 50ms@full load (typical) Rise time ......................................... 50ms@full load (typical)
Hold up time .................................... 20ms@full load (typical) Hold up time .................................... 20ms@full load (typical)
Operating temperature ................... -20 ~+50 Operating temperature ................... -20 ~+50
Safety standards ............................ meet GB4943, UL60950, EN60950 Safety standards ............................ meet GB4943, UL60950, EN60950
EMC standards ............................... meet GB9254, EN55022 classB, EN55024 EMC standards ............................... meet GB9254, EN55022 classB, EN55024
EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11 EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11
Cooling method ............................... convection Cooling method ............................... convection

Model DC Output R&N Efficiency Model DC Output R&N Efficiency


5V 0.3~6.0A 80mV 5V 2.0~15A 100mV
HF50W-DSM-A 79% HF125W-DSM-A 81%
12V 0.3~3.0A 120mV 12V 0.5~10A 120mV
5V 0.3~6.0A 80mV 5V 2.0~10A 100mV
HF50W-DSM-B 81% HF125W-DSM-B 81%
24V 0.2~2.0A 150mV 24V 0.4~5.0A 150mV
15W~350W Single Output E Series
15~350W Single Output E Series

Features: Hot! Value added


Low cost, competitive price
High reliability
Small size, high power density
Built-in EMI filter
100% full load burn-in test
Protections: overload/ short circuit
Free air cooling convection (HF350W-SE cooled by fan)
2 years warranty

AC input voltage range ................... 170~264VAC (210~370VDC) 75W Single Output 129 x 98 x 40(mm) weight: 0.38kg, 42pcs/CTN
Input frequency .............................. 47~63Hz
Inrush current .................................. cold start, 40A/230V (HF25~150W-SE) Model DC Output Load regul. R&N Efficiency
cold start, 60A/230V (HF350W-SE) HF75W-SE-12 12V 6.3A 0.5% 120mV 82%
Input leakage current ...................... 0.7mA/ 230VAC HF75W-SE-15 15V 5.0A 0.5% 120mV 83%
Line regulation (full load) ................. 0.5%
Output voltage adjust range ........... 10% HF75W-SE-24 24V 3.0A 0.5% 150mV 84%
HF15W-SE: HF75W-SE-27 27V 2.6A 0.5% 150mV 84%
Output overload protection ............. built-in IC protection, hiccup mode, HF75W-SE-48 48V 1.5A 0.5% 150mV 85%
auto recovery
HF25~100W-SE: * 12~48VDC output all available.
Output overload protection ............. 105~150%, hiccup mode, auto recovery
HF150W-SE, HF350W-SE:
Output overload protection ............. 110~130%, shut off, re-power on to recover
HF350W-SE:
Output over voltage protection ....... 115~150%, shut off, re-power on to recover 100W Single Output 160 x 98 x 39(mm) weight: 0.43kg, 36pcs/CTN
Withstand voltage ........................... I/P -O/P: 1.5KVAC/1min Model DC Output Load regul. R&N Efficiency
I/P -F/G: 1.5KVAC/1min
O/P-F/G: 0.5KVAC/1min HF100W-SE-12 12V 8.5A 0.5% 120mV 81%
Rise time ......................................... 50ms@full load (typical) HF100W-SE-15 15V 6.7A 0.5% 120mV 82%
Hold up time .................................... 20ms@full load (typical) HF100W-SE-24 24V 4.5A 0.5% 150mV 83%
Operating temperature ................... -20 ~+70 (refer to the derating curve)
Safety standards ............................ design meet GB4943, UL60950, EN60950 HF100W-SE-27 27V 3.7A 0.5% 150mV 84%
EMC standards ............................... design meet GB9254, EN55022 classA HF100W-SE-48 48V 2.1A 0.5% 150mV 85%
Cooling method ............................... convection (HF15~150W-SE) * 12~48VDC output all available.
fan (HF350W-SE)

15W Single Output 78 x 51 x 28(mm) weight: 0.14kg, 99pcs/CTN


Model DC Output Load regul. R&N Efficiency 150W Single Output 199 x 98 x 39(mm) weight: 0.59kg, 28pcs/CTN

HF15W-SE-5 5V 3.0A 0.5% 80mV 68% Model DC Output Load regul. R&N Efficiency
HF15W-SE-12 12V 1.3A 0.5% 120mV 78% HF150W-SE-5 5V 25.0A 0.5% 100mV 80%
HF15W-SE-24 24V 0.625A 0.5% 150mV 80% HF150W-SE-12 12V 12.5A 0.5% 120mV 83%
HF15W-SE-48 48V 0.31A 0.5% 150mV 81% HF150W-SE-15 15V 10.0A 0.5% 120mV 84%
* 5~48VDC output all available. HF150W-SE-24 24V 6.3A 0.5% 150mV 85%
HF150W-SE-48 48V 3.1A 0.5% 150mV 86%
25W Single Output 100 x 58 x 31(mm) weight: 0.15kg, 99pcs/CTN * 5~48VDC output all available.

Model DC Output Load regul. R&N Efficiency


HF25W-SE-12 12V 2.0A 0.5% 120mV 81%
HF25W-SE-15 15V 1.6A 0.5% 120mV 82%
350W Single Output 215 x 115 x 50(mm) weight: 0.89kg, 20pcs/CTN
HF25W-SE-24 24V 1.0A 0.5% 150mV 84%
HF25W-SE-48 48V 0.5A 0.5% 150mV 85% Model DC Output Load regul. R&N Efficiency
HF350W-SE-5 5V 60.0A 0.5% 120mV 78%
* 12~48VDC output all available.
HF350W-SE-12 12V 29.0A 0.5% 150mV 80%

35W Single Output 98.5 x 82 x 35(mm) weight: 0.24kg, 60pcs/CTN HF350W-SE-15 15V 23.0A 0.5% 150mV 81%
HF350W-SE-24 24V 14.6A 0.5% 150mV 84%
Model DC Output Load regul. R&N Efficiency
HF350W-SE-48 48V 7.3A 0.5% 240mV 86%
HF35W-SE-5 5V 7.0A 0.5% 80mV 77%
* 5~48VDC output all available.
HF35W-SE-12 12V 3.0A 0.5% 120mV 81%
HF35W-SE-24 24V 1.5A 0.5% 150mV 83%
HF35W-SE-48 48V 0.7A 0.5% 150mV 85%
* 5~48VDC output all available.

55W Single Output 99 x 97 x 36(mm) weight: 0.27kg, 42pcs/CTN


Model DC Output Load regul. R&N Efficiency
HF55W-SE-5 5V 10.0A 0.5% 80mV 73%
HF55W-SE-12 12V 4.6A 0.5% 120mV 80%
HF55W-SE-24 24V 2.3A 0.5% 150mV 83%
HF55W-SE-48 48V 1.2A 0.5% 150mV 84%
* 5~48VDC output all available. ISO9001 Certificate RoHS Certificate RoHS Certificate
35W~100W 2~3 Output E Series
35~100W 2~3 Output E Series

Features: Hot! Value added


Low cost, competitive price
High reliability
Small size, high power density
Built-in EMI filter
100% full load burn-in test
Protections: overload/ short circuit
Free air cooling convection
2 years warranty

AC input voltage range ................... 170~264VAC (210~370VDC) 100W Dual Output F605 160 x 98 x 39(mm)
Input frequency .............................. 47~63Hz
Inrush current .................................. cold start, 40A/230V
Model DC Output R&N Efficiency
Input leakage current ...................... 0.7mA/ 230VAC
Line regulation (full load) ................. 0.5% 5V 2.0~15.0A 100mV
HF100W-DE-A 73%
Output overload protection ............. 105~150%, hiccup mode, auto recovery 12V 0.5~5.00A 120mV
Load regulation ................................ V1: 0.5%, V2,V 3: 10%
5V 2.0~15.0A 100mV
Output voltage adjust range ........... V1: 5% of rated output voltage HF100W-DE-B 74%
Withstand voltage ........................... I/P -O/P: 1.5KVAC/1min 15V 0.4~4.00A 120mV
I/P -F/G: 1.5KVAC/1min 5V 2.0~15.0A 100mV
O/P-F/G: 0.5KVAC/1min HF100W-DE-C 76%
24V 0.3~3.00A 150mV
Rise time ......................................... 50ms@full load (typical)
Hold up time .................................... 20ms@full load (typical)
Operating temperature ................... -20 ~+70 (refer to the derating curve)
Safety standards ............................ design meet GB4943, UL60950, EN60950
EMC standards ............................... design meet GB9254, EN55022 classA 35W Triple Output F6025 98.5 x 82 x 35(mm)
Cooling method ............................... convection
Model DC Output R&N Efficiency
5V 0.5~3.5A 80mV
HF35W-TE-A 12V 0.1~1.2A 120mV 78%
35W Dual Output F6025 98.5 x 82 x 35(mm) -12V 0.1~0.8A 120mV
5V 0.5~3.5A 80mV
Model DC Output R&N Efficiency
HF35W-TE-B 15V 0.1~0.8A 120mV 78%
5V 0.5~4.0A 50mV
80mV
HF35W-D-A
HF35W-DE-A 68%
71% -15V 0.1~0.5A 120mV
5V 0.0~2.0A
0.2~2.0A 100mV
50mV
5V 0.5~3.5A 80mV
5V 0.5~4.0A 50mV
80mV
HF35W-D-B
HF35W-DE-B 69%
76% HF35W-TE-C 12V 0.1~1.2A 120mV 76%
12V 0.0~2.0A
0.2~2.0A 120mV
80mV
-5V 0.1~1.0A 100mV
5V 0.5~4.0A 50mV
80mV
HF35W-D-C
HF35W-DE-C 72%
77%
24V 0.0~1.0A
0.1~1.0A 100mV
150mV
12V 0.2~2.0A 120mV
80mV
HF35W-D-D
HF35W-DE-D 68%
78% 55W Triple Output F6055SE 99 x 97 x 36(mm)
12V 0.0~2.0A
0.2~2.0A 120mV
80mV

Model DC Output R&N Efficiency


5V 0.5~5.0A 80mV
55W Dual Output F6055SE 99 x 97 x 36(mm) HF55W-TE-A 12V 0.2~2.0A 120mV 78%
-12V 0.2~1.5A 120mV
Model DC Output R&N Efficiency
5V 0.5~5.0A 80mV
5V 0.5~6.0A 80mV
HF55W-DE-A 74% HF55W-TE-B 15V 0.2~2.0A 120mV 78%
12V 0.2~2.5A 120mV
-15V 0.1~1.0A 120mV
5V 0.5~6.0A 80mV 5V 0.6~7.0A 80mV
HF55W-DE-B 77%
24V 0.1~1.5A 150mV
HF55W-TE-C 12V 0.2~2.0A 120mV 76%
12V 0.2~2.3A 120mV
HF55W-DE-C 78% -5V 0.1~1.5A 100mV
12V 0.2~2.3A 120mV
15V 0.2~2.0A 120mV
HF55W-DE-D 78%
15V 0.2~2.0A 120mV
75W Triple Output F603 129 x 98 x 40(mm)

Model DC Output R&N Efficiency

75W Dual Output F603 129 x 98 x 40(mm) 5V 0.5~6.0A 80mV


HF75W-TE-A 12V 0.2~2.0A 120mV 78%
Model DC Output R&N Efficiency -12V 0.2~1.5A 120mV
12V 0.2~5.0A 120mV 5V 0.6~7.0A 80mV
HF75W-DE-A 78%
12V 0.2~2.5A 120mV HF75W-TE-B 15V 0.2~2.0A 120mV 78%
12V 0.2~5.0A 120mV -15V 0.1~1.0A 120mV
HF75W-DE-B 78%
15V 0.2~2.0A 120mV 5V 0.7~8.0A 80mV
12V 0.2~5.0A 120mV HF75W-TE-C 12V 0.2~2.0A 120mV 76%
HF75W-DE-C 79%
24V 0.2~2.0A 150mV -5V 0.1~1.5A 100mV
10W~20W Single Output Standard Series
10W Single Output Standard with approval 20W Single Output Standard with approval
Universal AC input / full range Universal AC input / full range
High reliability High reliability
Approvals: CE Approvals: CE
Protections: overload/ over voltage/ Protections: overload/ over voltage/
short circuit short circuit
5 years limited warranty 5 years limited warranty
F601 100 x 58 x 31(mm) F602 111 x 78 x 36(mm)

AC input voltage range ................... 85~264VAC (120~370VDC) AC input voltage range ................... 85~264VAC (120~370VDC)
Input frequency .............................. 47~63Hz Input frequency .............................. 47~63Hz
Inrush current .................................. cold start, 15A/115V, 30A/230V Inrush current .................................. cold start, 15A/115V, 30A/230V
Input leakage current ...................... 0.7mA/ 230VAC Input leakage current ...................... 1mA/ 230VAC
Line regulation (full load) ................. 0.5% Line regulation (full load) ................. 0.5%
Output voltage adjust range ........... 10% Output voltage adjust range ........... 10%
Output overload protection ............. built-in IC protection, hiccup mode, Output overload protection ............. built-in IC protection, hiccup mode,
auto recovery auto recovery
Output over voltage protection ....... clamping by zenor diode Output over voltage protection ....... clamping by zenor diode
Withstand voltage ........................... I/P -O/P: 3.0KVAC/1min Withstand voltage ........................... I/P -O/P: 3.0KVAC/1min
I/P -F/G: 1.5KVAC/1min I/P -F/G: 1.5KVAC/1min
O/P-F/G: 0.5KVAC/1min O/P-F/G: 0.5KVAC/1min
Rise time ......................................... 50ms@full load (typical) Rise time ......................................... 50ms@full load (typical)
Hold up time .................................... 20ms@full load (typical) Hold up time .................................... 20ms@full load (typical)
Operating temperature ................... -20 ~+50 Operating temperature ................... -20 ~+50
Safety standards ............................ GB4943, UL60950, EN60950 Safety standards ............................ GB4943, UL60950, EN60950
EMC standards ............................... GB9254, EN55022 classB, EN55024 EMC standards ............................... GB9254, EN55022 classB, EN55024
EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11 EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11
Cooling method ............................... convection Cooling method ............................... convection
Packing ........................................... 0.15kg/pcs, 99pcs/CTN Packing ........................................... 0.26kg/pcs, 64pcs/CTN
Model DC Output Load regul. R&N Efficiency Model DC Output Load regul. R&N Efficiency
HF10W-SL-5 5V 2.0A 0.5% 80mV 71% HF20W-SL-5 5V 4.0A 0.5% 80mV 77%
HF10W-SL-12 12V 0.85A 0.5% 120mV 76% HF20W-SL-12 12V 1.7A 0.5% 120mV 81%
HF10W-SL-15 15V 0.7A 0.5% 120mV 76% HF20W-SL-15 15V 1.4A 0.5% 120mV 82%
HF10W-SL-24 24V 0.4A 0.5% 150mV 77% HF20W-SL-24 24V 0.8A 0.5% 150mV 82%
HF10W-SL-48 48V 0.2A 0.5% 150mV 79% HF20W-SL-48 48V 0.4A 0.5% 150mV 83%
* 3~48VDC output all available. * 3~48VDC output all available.

10W Single Output Standard Series 20W Single Output Standard Series
High reliability, low cost High reliability, low cost
Built-in EMI filter Built-in EMI filter
100% full load burn-in test 100% full load burn-in test
Protections: overload/ short circuit Protections: overload/ short circuit
5 years limited warranty 5 years limited warranty
F601 100 x 58 x 31(mm) F602 111 x 78 x 36(mm)

AC input voltage range ................... 170~264VAC (210~370VDC) AC input voltage range ................... 170~264VAC (210~370VDC)
Input frequency .............................. 47~63Hz Input frequency .............................. 47~63Hz
Inrush current .................................. cold start, 30A/230V Inrush current .................................. cold start, 30A/230V
Input leakage current ...................... 0.7mA/ 230VAC Input leakage current ...................... 0.7mA/ 230VAC
Line regulation (full load) ................. 0.5% Line regulation (full load) ................. 0.5%
Output voltage adjust range ........... 10% Output voltage adjust range ........... 10%
Output overload protection ............. 105~150%, hiccup mode, auto recovery Output overload protection ............. 105~150%
Withstand voltage ........................... I/P -O/P: 1.5KVAC/1min Withstand voltage ........................... I/P -O/P: 1.5KVAC/1min
I/P -F/G: 1.5KVAC/1min I/P -F/G: 1.5KVAC/1min
O/P-F/G: 0.5KVAC/1min O/P-F/G: 0.5KVAC/1min
Rise time ......................................... 50ms@full load (typical) Rise time ......................................... 50ms@full load (typical)
Hold up time .................................... 20ms@full load (typical) Hold up time .................................... 20ms@full load (typical)
Operating temperature ................... -20 ~+50 Operating temperature ................... -20 ~+50
Safety standards ............................ design meet GB4943, UL60950, EN60950 Safety standards ............................ design meet GB4943, UL60950, EN60950
EMC standards ............................... design meet GB9254, EN55022 classA EMC standards ............................... design meet GB9254, EN55022 classA
EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11 EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11
Cooling method ............................... convection Cooling method ............................... convection
Packing ........................................... 0.13kg/pcs, 99pcs/CTN Packing ........................................... 0.25kg/pcs, 64pcs/CTN

Model DC Output Load regul. R&N Efficiency Model DC Output Load regul. R&N Efficiency
HF10W-S-5 5V 2.0A 0.5% 80mV 71% HF20W-S-5 5V 4.0A 0.5% 80mV 70%
HF10W-S-12 12V 1.0A 0.5% 120mV 76% HF20W-S-12 12V 2.0A 0.5% 120mV 76%
HF10W-S-15 15V 0.8A 0.5% 120mV 78% HF20W-S-15 15V 1.5A 0.5% 120mV 77%
HF10W-S-24 24V 0.5A 0.5% 150mV 79% HF20W-S-24 24V 1.0A 0.5% 150mV 78%
HF10W-S-48 48V 0.2A 0.5% 150mV 80% HF20W-S-48 48V 0.5A 0.5% 150mV 79%
* 3~48VDC output all available. * 3~48VDC output all available.
25W~40W Single Output Standard Series
25W Single Output Standard with approval 35W Single Output Standard Series
Universal AC input / full range High reliability, low cost
High reliability Built-in EMI filter
Approvals: UL/ CUL/ CE 100% full load burn-in test
Protections: overload/ over voltage/ Protections: overload/ short circuit
short circuit 5 years limited warranty
5 years limited warranty F603 129 x 98 x 40(mm)
F6025 98.5 x 82 x 35(mm)

AC input voltage range ................... 85~264VAC (120~370VDC) AC input voltage range ................... 170~264VAC (210~370VDC)
Input frequency .............................. 47~63Hz Input frequency .............................. 47~63Hz
Inrush current .................................. cold start, 20A/115V, 40A/230V Inrush current .................................. cold start, 40A/230V
Input leakage current ...................... 1mA/ 230VAC Input leakage current ...................... 0.7mA/ 230VAC
Line regulation (full load) ................. 0.5% Line regulation (full load) ................. 0.5%
Output voltage adjust range ........... 10% Output voltage adjust range ........... 10%
Output overload protection ............. 105~150%, hiccup mode, auto recovery Output overload protection ............. 105~150%
Output over voltage protection ....... 115~150%, shut off, re-power on to recover Withstand voltage ........................... I/P -O/P: 1.5KVAC/1min
Withstand voltage ........................... I/P -O/P: 3.0KVAC/1min I/P -F/G: 1.5KVAC/1min
I/P -F/G: 1.5KVAC/1min O/P-F/G: 0.5KVAC/1min
O/P-F/G: 0.5KVAC/1min Rise time ......................................... 50ms@full load (typical)
Rise time ......................................... 50ms@full load (typical) Hold up time .................................... 20ms@full load (typical)
Hold up time .................................... 20ms@full load (typical) Operating temperature ................... -20 ~+50
Operating temperature ................... -20 ~+50 Safety standards ............................ design meet GB4943, UL60950, EN60950
Safety standards ............................ GB4943, UL60950, EN60950 EMC standards ............................... design meet GB9254, EN55022 classA
EMC standards ............................... GB9254, EN55022 classB, EN55024 EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11
EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11 Cooling method ............................... convection
Cooling method ............................... convection Packing ........................................... 0.34kg/pcs, 42pcs/CTN
Packing ........................................... 0.24kg/pcs, 60pcs/CTN

Model DC Output Load regul. R&N Efficiency


HF25W-SL-3.3 3.3V 6.0A 0.5% 80mV 66% Model DC Output Load regul. R&N Efficiency
HF25W-SL-5 5V 5.0A 0.5% 80mV 76% HF35W-S-5 5V 7.0A 0.5% 80mV 73%
HF25W-SL-12 12V 2.1A 0.5% 120mV 79% HF35W-S-12 12V 3.0A 0.5% 120mV 76%
HF25W-SL-15 15V 1.7A 0.5% 120mV 81% HF35W-S-15 15V 2.4A 0.5% 120mV 79%
HF25W-SL-24 24V 1.1A 0.5% 150mV 79% HF35W-S-24 24V 1.5A 0.5% 150mV 79%
HF25W-SL-48 48V 0.57A 0.5% 150mV 83% HF35W-S-48 48V 0.7A 0.5% 150mV 80%
* 3~48VDC output all available. * 3~48VDC output all available.

30W Single Output Standard with approval 40W Single Output Standard with approval
AC input range selected by switch Universal AC input / full range
High reliability High reliability
Approvals: CE Approvals: UL/ CUL/ CE
Protections: overload/ over voltage/ Protections: overload/ over voltage/
short circuit short circuit
5 years limited warranty 5 years limited warranty
F603 129 x 98 x 40(mm) F603 129 x 98 x 40(mm)

AC input voltage range ................... 85~132/ 170~264VAC selected by switch AC input voltage range ................... 85~264VAC (120~370VDC)
Input frequency .............................. 47~63Hz Input frequency .............................. 47~63Hz
Inrush current .................................. cold start, 20A/115V, 40A/230V Inrush current .................................. cold start, 20A/115V, 40A/230V
Input leakage current ...................... 1mA/ 230VAC Input leakage current ...................... 1mA/ 230VAC
Line regulation (full load) ................. 0.5% Line regulation (full load) ................. 0.5%
Output voltage adjust range ........... 10% Output voltage adjust range ........... 10%
Output overload protection ............. 105~150% Output overload protection ............. 105~150%, hiccup mode, auto recovery
Output over voltage protection ....... 115~150%, shut off, re-power on to recover Output over voltage protection ....... 115~150%, hiccup mode, auto recovery
Withstand voltage ........................... I/P -O/P: 3.0KVAC/1min Withstand voltage ........................... I/P -O/P: 3.0KVAC/1min
I/P -F/G: 1.5KVAC/1min I/P -F/G: 1.5KVAC/1min
O/P-F/G: 0.5KVAC/1min O/P-F/G: 0.5KVAC/1min
Rise time ......................................... 50ms@full load (typical) Rise time ......................................... 50ms@full load (typical)
Hold up time .................................... 20ms@full load (typical) Hold up time .................................... 20ms@full load (typical)
Operating temperature ................... -20 ~+50 Operating temperature ................... -20 ~+50
Safety standards ............................ GB4943, UL60950, EN60950 Safety standards ............................ GB4943, UL60950, EN60950
EMC standards ............................... GB9254, EN55022 classB, EN55024 EMC standards ............................... GB9254, EN55022 classB, EN55024
EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11 EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11
Cooling method ............................... convection Cooling method ............................... convection
Packing ........................................... 0.38kg/pcs, 42pcs/CTN Packing ........................................... 0.37kg/pcs, 42pcs/CTN

Model DC Output Load regul. R&N Efficiency Model DC Output Load regul. R&N Efficiency
HF30W-SF-5 5V 6.0A 0.5% 80mV 67% HF40W-SL-5 5V 8.0A 0.5% 80mV 75%
HF30W-SF-12 12V 2.5A 0.5% 120mV 72% HF40W-SL-12 12V 3.5A 0.5% 120mV 80%
HF30W-SF-15 15V 2.0A 0.5% 120mV 73% HF40W-SL-15 15V 2.8A 0.5% 120mV 81%
HF30W-SF-24 24V 1.3A 0.5% 150mV 75% HF40W-SL-24 24V 1.8A 0.5% 150mV 82%
HF30W-SF-48 48V 0.6A 0.5% 150mV 78% HF40W-SL-48 48V 0.9A 0.5% 150mV 83%
* 3~48VDC output all available. * 3~48VDC output all available.
50W~70W Single Output Standard Series
50W Single Output Standard with approval 60W Single Output Standard with approval
AC input range selected by switch Universal AC input / full range
High reliability High reliability
Approvals: CE Approvals: UL/ CUL/ CE
Protections: overload/ over voltage/ Protections: overload/ over voltage/
short circuit short circuit
5 years limited warranty 5 years limited warranty
F605 160 x 98 x 39(mm) F605 160 x 98 x 39(mm)

AC input voltage range ................... 85~132/ 170~264VAC selected by switch AC input voltage range ................... 85~264VAC (120~370VDC)
Input frequency .............................. 47~63Hz Input frequency .............................. 47~63Hz
Inrush current .................................. cold start, 20A/115V, 40A/230V Inrush current .................................. cold start, 20A/115V, 40A/230V
Input leakage current ...................... 1mA/ 230VAC Input leakage current ...................... 1mA/ 230VAC
Line regulation (full load) ................. 0.5% Line regulation (full load) ................. 0.5%
Output voltage adjust range ........... 10% Output voltage adjust range ........... 10%
Output overload protection ............. 105~150% Output overload protection ............. 105~150%, hiccup mode, auto recovery
Output over voltage protection ....... 115~150%, shut off, re-power on to recover Output over voltage protection ....... 115~150%, hiccup mode, auto recovery
Withstand voltage ........................... I/P -O/P: 3.0KVAC/1min Withstand voltage ........................... I/P -O/P: 3.0KVAC/1min
I/P -F/G: 1.5KVAC/1min I/P -F/G: 1.5KVAC/1min
O/P-F/G: 0.5KVAC/1min O/P-F/G: 0.5KVAC/1min
Rise time ......................................... 50ms@full load (typical) Rise time ......................................... 50ms@full load (typical)
Hold up time .................................... 20ms@full load (typical) Hold up time .................................... 20ms@full load (typical)
Operating temperature ................... -20 ~+50 Operating temperature ................... -20 ~+50
Safety standards ............................ GB4943, UL60950, EN60950 Safety standards ............................ GB4943, UL60950, EN60950
EMC standards ............................... GB9254, EN55022 classB, EN55024 EMC standards ............................... GB9254, EN55022 classB, EN55024
EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11 EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11
Cooling method ............................... convection Cooling method ............................... convection
Packing ........................................... 0.47kg/pcs, 36pcs/CTN Packing ........................................... 0.46kg/pcs, 36pcs/CTN

Model DC Output Load regul. R&N Efficiency Model DC Output Load regul. R&N Efficiency
HF50W-SF-5 5V 10.0A 0.5% 80mV 73% HF60W-SL-5 5V 12.0A 0.5% 80mV 78%
HF50W-SF-12 12V 4.2A 0.5% 120mV 77% HF60W-SL-12 12V 5.0A 0.5% 120mV 82%
HF50W-SF-15 15V 3.4A 0.5% 120mV 79% HF60W-SL-15 15V 4.0A 0.5% 120mV 82%
HF50W-SF-24 24V 2.1A 0.5% 150mV 79% HF60W-SL-24 24V 2.5A 0.5% 150mV 81%
HF50W-SF-48 48V 1.0A 0.5% 150mV 80% HF60W-SL-48 48V 1.3A 0.5% 150mV 82%
* 3~48VDC output all available. * 3~48VDC output all available.

55W Single Output Standard Series 70W Single Output Standard with approval
High reliability, low cost AC input range selected by switch
Built-in EMI filter High reliability
100% full load burn-in test Approvals: CE
Protections: overload/ short circuit Protections: overload/ over voltage/
5 years limited warranty short circuit
F605 160 x 98 x 39(mm) 5 years limited warranty
F605 160 x 98 x 39(mm)

AC input voltage range ................... 170~264VAC (210~370VDC) AC input voltage range ................... 85~132/ 170~264VAC selected by switch
Input frequency .............................. 47~63Hz Input frequency .............................. 47~63Hz
Inrush current .................................. cold start, 40A/230V Inrush current .................................. cold start, 20A/115V, 40A/230V
Input leakage current ...................... 0.7mA/ 230VAC Input leakage current ...................... 1mA/ 230VAC
Line regulation (full load) ................. 0.5% Line regulation (full load) ................. 0.5%
Output voltage adjust range ........... 10% Output voltage adjust range ........... 10%
Output overload protection ............. 105~150%, hiccup mode, auto recovery Output overload protection ............. 105~150%, hiccup mode, auto recovery
Withstand voltage ........................... I/P -O/P: 1.5KVAC/1min Output over voltage protection ....... 115~150%, hiccup mode, auto recovery
I/P -F/G: 1.5KVAC/1min Withstand voltage ........................... I/P -O/P: 3.0KVAC/1min
O/P-F/G: 0.5KVAC/1min I/P -F/G: 1.5KVAC/1min
Rise time ......................................... 50ms@full load (typical) O/P-F/G: 0.5KVAC/1min
Hold up time .................................... 20ms@full load (typical) Rise time ......................................... 50ms@full load (typical)
Operating temperature ................... -20 ~+50 Hold up time .................................... 20ms@full load (typical)
Safety standards ............................ design meet GB4943, UL60950, EN60950 Operating temperature ................... -20 ~+50
EMC standards ............................... design meet GB9254, EN55022 classA Safety standards ............................ GB4943, UL60950, EN60950
EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11 EMC standards ............................... GB9254, EN55022 classB, EN55024
Cooling method ............................... convection EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11
Packing ........................................... 0.43kg/pcs, 36pcs/CTN Cooling method ............................... convection
Packing ........................................... 0.48kg/pcs, 36pcs/CTN

Model DC Output Load regul. R&N Efficiency Model DC Output Load regul. R&N Efficiency
HF55W-S-5 5V 11.0A 0.5% 80mV 74% HF70W-SF-12 12V 6.0A 0.5% 120mV 80%
HF55W-S-12 12V 4.6A 0.5% 120mV 78% HF70W-SF-15 15V 4.7A 0.5% 120mV 80%
HF55W-S-15 15V 3.7A 0.5% 120mV 79% HF70W-SF-24 24V 3.0A 0.5% 150mV 81%
HF55W-S-24 24V 2.3A 0.5% 150mV 81% HF70W-SF-27 27V 2.6A 0.5% 150mV 80%
HF55W-S-48 48V 1.2A 0.5% 150mV 82% HF70W-SF-48 48V 1.5A 0.5% 150mV 84%
* 3~48VDC output all available. * 12~48VDC output all available.
70W~100W Single Output Standard Series
70W Single Output Standard Series 100W Single Output Standard with approval
High reliability, low cost AC input range selected by switch
Built-in EMI filter High reliability
100% full load burn-in test Approvals: UL/ CUL/ CB/ CE/ CCC
Protections: overload/ short circuit Protections: overload/ over voltage/
5 years limited warranty short circuit
F605 160 x 98 x 39(mm) 5 years limited warranty
F610 199 x 98 x 39(mm)

AC input voltage range ................... 170~264VAC (210~370VDC) AC input voltage range ................... 85~132/ 170~264VAC selected by switch
Input frequency .............................. 47~63Hz Input frequency .............................. 47~63Hz
Inrush current .................................. cold start, 40A/230V Inrush current .................................. cold start, 20A/115V, 40A/230V
Input leakage current ...................... 0.7mA/ 230VAC Input leakage current ...................... 1mA/ 230VAC
Line regulation (full load) ................. 0.5% Line regulation (full load) ................. 0.5%
Output voltage adjust range ........... 10% Output voltage adjust range ........... 10%
Output overload protection ............. 105~150%, hiccup mode, auto recovery Output overload protection ............. 110~130%, shut off, re-power on to recover
Withstand voltage ........................... I/P -O/P: 1.5KVAC/1min Output over voltage protection ....... 115~150%, shut off, re-power on to recover
I/P -F/G: 1.5KVAC/1min Withstand voltage ........................... I/P -O/P: 3.0KVAC/1min
O/P-F/G: 0.5KVAC/1min I/P -F/G: 1.5KVAC/1min
Rise time ......................................... 50ms@full load (typical) O/P-F/G: 0.5KVAC/1min
Hold up time .................................... 20ms@full load (typical) Rise, Hold up time .......................... 50ms, 20ms@full load (typical)
Operating temperature ................... -20 ~+50 Operating temperature ................... -20 ~+50
Safety standards ............................ design meet GB4943, UL60950, EN60950 Safety standards ............................ GB4943, UL60950, EN60950
EMC standards ............................... design meet GB9254, EN55022 classA EMC standards ............................... GB9254, EN55022 classB, EN55024
EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11 EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11
Cooling method ............................... convection Cooling method ............................... convection
Packing ........................................... 0.44kg/pcs, 36pcs/CTN Packing ........................................... 0.65kg/pcs, 28pcs/CTN
Model DC Output Load regul. R&N Efficiency
HF100W-SF-5 5V 20.0A 0.5% 100mV 79%
Model DC Output Load regul. R&N Efficiency HF100W-SF-7.5 7.5V 13.5A 0.5% 100mV 79%
HF70W-S-12 12V 6.0A 0.5% 120mV 80% HF100W-SF-12 12V 8.5A 0.5% 120mV 81%
HF70W-S-15 15V 4.7A 0.5% 120mV 81% HF100W-SF-13.8 13.8V 7.5A 0.5% 120mV 83%
HF70W-S-24 24V 3.0A 0.5% 150mV 82% HF100W-SF-15 15V 6.7A 0.5% 120mV 83%
HF70W-S-27 27V 2.6A 0.5% 150mV 84% HF100W-SF-24 24V 4.5A 0.5% 150mV 84%
HF70W-S-48 48V 1.5A 0.5% 150mV 85% HF100W-SF-48 48V 2.2A 0.5% 150mV 86%
* 12~48VDC output all available. * 3~48VDC output all available.

75W Single Output Series with PFC 100W Single Output Standard Series
Universal AC input / full range High reliability, low cost
PF>0.95@115VAC; >0.9@230VAC Built-in EMI filter
No load power consumption<0.5W 100% full load burn-in test
Remote ON/OFF control (option) Protections: overload/ short circuit
Protections: overload/ over voltage/ 5 years limited warranty
short circuit F610 199 x 98 x 39(mm)
5 years limited warranty
F6075C 129 x 98 x 38(mm)

AC input voltage range ................... 85~264VAC (120~370VDC) AC input voltage range ................... 170~264VAC (210~370VDC)
Input frequency .............................. 47~63Hz Input frequency .............................. 47~63Hz
Inrush current .................................. cold start, 35A/115V, 65A/230V Inrush current .................................. cold start, 40A/230V
Input leakage current ...................... 1mA/ 230VAC Input leakage current ...................... 0.7mA/ 230VAC
Line regulation (full load) ................. 0.5% Line regulation (full load) ................. 0.5%
Output voltage adjust range ........... 10% Output voltage adjust range ........... 10%
Output overload protection ............. 105~135%, current limiting, auto recovery Output overload protection ............. 110~130%, shut off, re-power on to recover
Output over voltage protection ....... 115~150%, shut off, re-power on to recover Withstand voltage ........................... I/P -O/P: 1.5KVAC/1min
Short circuit protection .................... hiccup mode, auto recovery I/P -F/G: 1.5KVAC/1min
Withstand voltage ........................... I/P -O/P: 3.0KVAC/1min O/P-F/G: 0.5KVAC/1min
I/P -F/G: 1.5KVAC/1min Rise time ......................................... 50ms@full load (typical)
O/P-F/G: 0.5KVAC/1min Hold up time .................................... 20ms@full load (typical)
Rise time ......................................... 50ms@full load (typical) Operating temperature ................... -20 ~+50
Hold up time .................................... 20ms@full load (typical) Safety standards ............................ design meet GB4943, UL60950, EN60950
Operating temperature ................... -20 ~+50 EMC standards ............................... design meet GB9254, EN55022 classA
Safety standards ............................ meet GB4943, UL60950, EN60950 EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11
EMC standards ............................... meet GB9254, EN55022 classB, EN55024 Cooling method ............................... convection
EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11 Packing ........................................... 0.58kg/pcs, 28pcs/CTN
Cooling method ............................... convection
Packing ........................................... 0.43kg/pcs, 36pcs/CTN
Model DC Output Load regul. R&N Efficiency
HF100W-S-5 5V 20.0A 0.5% 100mV 78%
HF100W-S-7.5 7.5V 13.5A 0.5% 100mV 78%
Model DC Output Load regul. R&N Efficiency HF100W-S-12 12V 9.0A 0.5% 120mV 82%
HF75W-SC-5 5V 15.0A 2.0% 80mV 82.5% HF100W-S-13.8 13.8V 8.0A 0.5% 120mV 81%
HF75W-SC-12 12V 6.3A 1.0% 120mV 87.0% HF100W-S-15 15V 7.0A 0.5% 120mV 83%
HF75W-SC-24 24V 3.2A 0.5% 150mV 88.5% HF100W-S-24 24V 5.0A 0.5% 150mV 85%
HF75W-SC-48 48V 1.6A 0.5% 150mV 89.0% HF100W-S-48 48V 2.1A 0.5% 150mV 86%
* 5~48VDC output all available. * 3~48VDC output all available.
100W~150W Single Output Standard Series
100W Single Output Series with PFC 150W Single Output Standard Series
Universal AC input / full range High reliability, low cost
High reliability Built-in EMI filter
PF>0.98@115VAC; >0.94@230VAC 100% full load burn-in test
Protections: overload/ over voltage/ Protections: overload/ short circuit
short circuit 5 years limited warranty
5 years limited warranty F615 199 x 98 x 50(mm)
F610C 179 x 99 x 45(mm)

AC input voltage range ................... 85~264VAC (120~370VDC) AC input voltage range ................... 170~264VAC (210~370VDC)
Input frequency .............................. 47~63Hz Input frequency .............................. 47~63Hz
Inrush current .................................. cold start, 20A/115V, 40A/230V Inrush current .................................. cold start, 40A/230V
Input leakage current ...................... 1mA/ 230VAC Input leakage current ...................... 0.7mA/ 230VAC
Line regulation (full load) ................. 0.5% Line regulation (full load) ................. 0.5%
Output voltage adjust range ........... 10% Output voltage adjust range ........... 10%
Output overload protection ............. 105~150%, current limiting, auto recovery Output overload protection ............. 110~130%, shut off, re-power on to recover
Output over voltage protection ....... 115~150%, hiccup mode, auto recovery Withstand voltage ........................... I/P -O/P: 1.5KVAC/1min
Withstand voltage ........................... I/P -O/P: 3.0KVAC/1min I/P -F/G: 1.5KVAC/1min
I/P -F/G: 1.5KVAC/1min O/P-F/G: 0.5KVAC/1min
O/P-F/G: 0.5KVAC/1min Rise time ......................................... 50ms@full load (typical)
Rise, Hold up time .......................... 50ms, 20ms@full load (typical) Hold up time .................................... 20ms@full load (typical)
Operating temperature ................... -20 ~+50 Operating temperature ................... -20 ~+50
Safety standards ............................ meet GB4943, UL60950, EN60950 Safety standards ............................ design meet GB4943, UL60950, EN60950
EMC standards ............................... meet GB9254, EN55022 classB, EN55024 EMC standards ............................... design meet GB9254, EN55022 classA
EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11 EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11
Cooling method ............................... convection Cooling method ............................... convection
Packing ........................................... 0.60kg/pcs, 24pcs/CTN Packing ........................................... 0.66kg/pcs, 24pcs/CTN
Model DC Output Load regul. R&N Efficiency Model DC Output Load regul. R&N Efficiency
HF100W-SC-3.3 3.3V 20.0A 0.5% 100mV 70% HF150W-S-5 5V 30.0A 0.5% 100mV 79%
HF100W-SC-5 5V 20.0A 0.5% 100mV 77% HF150W-S-7.5 7.5V 20.0A 0.5% 100mV 81%
HF100W-SC-7.5 7.5V 13.5A 0.5% 100mV 79% HF150W-S-9 9V 17.0A 0.5% 100mV 82%
HF100W-SC-12 12V 8.5A 0.5% 120mV 82% HF150W-S-12 12V 12.5A 0.5% 120mV 82%
HF100W-SC-15 15V 6.7A 0.5% 120mV 83% HF150W-S-24 24V 6.3A 0.5% 150mV 84%
HF100W-SC-24 24V 4.2A 0.5% 150mV 84% HF150W-S-36 36V 4.2A 0.5% 150mV 85%
HF100W-SC-48 48V 2.1A 0.5% 150mV 84% HF150W-S-48 48V 3.1A 0.5% 150mV 85%
* 3~48VDC output all available. * 3~48VDC output all available.

150W Single Output Standard with approval 150W Single Output Series with PFC
AC input range selected by switch Universal AC input / full range
High reliability High reliability
Approvals: UL/ CUL/ CE Approvals: TUV/ CB/ CE
Protections: overload/ over voltage/ PF>0.98@115VAC; >0.94@230VAC
short circuit Protections: overload/ over voltage/
5 years limited warranty over temperature/ short circuit
F615UL 199 x 110 x 50(mm) 5 years limited warranty
F615C 199 x 99 x 50(mm)

AC input voltage range ................... 88~132/ 176~264VAC selected by switch AC input voltage range ................... 85~264VAC (120~370VDC)
Input frequency .............................. 47~63Hz Input frequency .............................. 47~63Hz
Inrush current .................................. cold start, 20A/115V, 40A/230V Inrush current .................................. cold start, 20A/115V, 40A/230V
Input leakage current ...................... 1mA/ 230VAC Input leakage current ...................... 1mA/ 230VAC
Line regulation (full load) ................. 0.5% Line regulation (full load) ................. 0.5%
Output voltage adjust range ........... 10% Output voltage adjust range ........... 10%
Output overload protection ............. 110~130%, shut off, re-power on to recover Output overload protection ............. 105~150%, current limiting, auto recovery
Output over voltage protection ....... 115~150%, shut off, re-power on to recover Output over voltage protection ....... 115~150%, shut off, re-power on to recover
Withstand voltage ........................... I/P -O/P: 3.0KVAC/1min Withstand voltage ........................... I/P -O/P: 3.0KVAC/1min
I/P -F/G: 1.5KVAC/1min I/P -F/G: 1.5KVAC/1min
O/P-F/G: 0.5KVAC/1min O/P-F/G: 0.5KVAC/1min
Rise, Hold up time .......................... 50ms, 20ms@full load (typical) Rise, Hold up time .......................... 50ms, 20ms@full load (typical)
Operating temperature ................... -20 ~+50 Operating temperature ................... -20 ~+50
Safety standards ............................. GB4943, UL60950, EN60950 Safety standards ............................ GB4943, UL60950, EN60950
EMC standards ............................... GB9254, EN55022 classB, EN55024 EMC standards ............................... GB9254, EN55022 classB, EN55024
EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11 EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11
Cooling method ............................... convection Cooling method ............................... convection
Packing ........................................... 0.71kg/pcs, 20pcs/CTN Packing ........................................... 0.71kg/pcs, 22pcs/CTN
Model DC Output Load regul. R&N Efficiency
Model DC Output Load regul. R&N Efficiency HF150W-SC-3.3 3.3V 30.0A 0.5% 100mV 73%
HF150W-SF-5 5V 30.0A 0.5% 100mV 80% HF150W-SC-5 5V 30.0A 0.5% 100mV 79%
HF150W-SF-7.5 7.5V 20.0A 0.5% 100mV 80% HF150W-SC-7.5 7.5V 20.0A 0.5% 100mV 81%
HF150W-SF-9 9V 16.7A 0.5% 100mV 81% HF150W-SC-12 12V 12.5A 0.5% 120mV 84%
HF150W-SF-12 12V 12.5A 0.5% 120mV 83% HF150W-SC-13.5 13.5V 11.2A 0.5% 120mV 85%
HF150W-SF-24 24V 6.5A 0.5% 150mV 84% HF150W-SC-15 15V 10.0A 0.5% 120mV 85%
HF150W-SF-27 27V 5.6A 0.5% 150mV 84% HF150W-SC-24 24V 6.3A 0.5% 150mV 86%
HF150W-SF-36 36V 4.2A 0.5% 150mV 85% HF150W-SC-48 48V 3.2A 0.5% 150mV 86%
* 3~48VDC output all available. * 3~48VDC output all available.
200W~400W Single Output Standard Series
200W Single Output Standard Series 240W Single Output Standard with approval
High reliability, low cost AC input range selected by switch
Built-in EMI filter High reliability
100% full load burn-in test Approvals: UL/ CUL/ CE
Protections: overload/ short circuit Protections: overload/ over voltage/
5 years limited warranty short circuit
F620 200 x 110 x 50(mm) 5 years limited warranty
F615UL 199 x 110 x 50(mm)

AC input voltage range ................... 170~264VAC (210~370VDC) AC input voltage range ................... 85~132/ 170~264VAC selected by switch
Input frequency .............................. 47~63Hz Input frequency .............................. 47~63Hz
Inrush current .................................. cold start, 40A/230V Inrush current .................................. cold start, 20A/115V, 40A/230V
Input leakage current ...................... 0.7mA/ 230VAC Input leakage current ...................... 1mA/ 230VAC
Line regulation (full load) ................. 0.5% Line regulation (full load) ................. 0.5%
Output voltage adjust range ........... 10% Output voltage adjust range ........... 10%
Output overload protection ............. 110~130%, shut off, re-power on to recover Output overload protection ............. 110~130%, shut off, re-power on to recover
Withstand voltage ........................... I/P -O/P: 1.5KVAC/1min Output over voltage protection ....... 115~150%, shut off, re-power on to recover
I/P -F/G: 1.5KVAC/1min Withstand voltage ........................... I/P -O/P: 3.0KVAC/1min
O/P-F/G: 0.5KVAC/1min I/P -F/G: 1.5KVAC/1min
Rise time ......................................... 50ms@full load (typical) O/P-F/G: 0.5KVAC/1min
Hold up time .................................... 20ms@full load (typical) Rise time ......................................... 50ms@full load (typical)
Operating temperature ................... -20 ~+50 Hold up time .................................... 20ms@full load (typical)
Safety standards ............................ design meet GB4943, UL60950, EN60950 Operating temperature ................... -20 ~+40
EMC standards ............................... design meet GB9254, EN55022 classA Safety standards ............................ meet GB4943, UL60950, EN60950
Cooling method ............................... convection EMC standards ............................... meet GB9254, EN55022 classA
Packing ........................................... 0.83kg/pcs, 20pcs/CTN Cooling method ............................... convection (If used in confined space,
external fan cooling is requested)
Packing ........................................... 0.91kg/pcs, 20pcs/CTN

Model DC Output Load regul. R&N Efficiency Model DC Output Load regul. R&N Efficiency
HF200W-S-5 5V 40.0A 0.5% 100mV 80% HF240W-SF-5 5V 40.0A 0.5% 100mV 79%
HF200W-S-7.5 7.5V 26.5A 0.5% 100mV 81% HF240W-SF-12 12V 18.0A 0.5% 120mV 83%
HF200W-S-9 9V 22.0A 0.5% 100mV 82% HF240W-SF-15 15V 15.0A 0.5% 120mV 85%
HF200W-S-12 12V 16.7A 0.5% 120mV 84% HF240W-SF-24 24V 10.0A 0.5% 150mV 85%
HF200W-S-24 24V 10.0A 0.5% 150mV 85% HF240W-SF-30 30V 8.0A 0.5% 150mV 86%
HF200W-S-48 48V 5.0A 0.5% 150mV 87% HF240W-SF-48 48V 5.0A 0.5% 150mV 87%
* 3~48VDC output all available. * 3~48VDC output all available.

200W Single Output Series with PFC 300~400W Single Output Standard Series
Universal AC input / full range High reliability, low cost
PF>0.98@115VAC; >0.94@230VAC Built in fan speed control
Built in fan speed control 100% full load burn-in test
Approvals: UL/ TUV/ CB/ CE/ CCC Protections: overload/ over voltage/
Protections: overload/ over voltage/ over temperature/ short circuit
over temperature/ short circuit 5 years limited warranty
5 years limited warranty F630 241 x 124 x 65(mm)
F620C 199 x 99 x 50(mm)

AC input voltage range ................... 85~264VAC (120~370VDC) AC input voltage range ................... 170~264VAC (210~370VDC)
Input frequency .............................. 47~63Hz Input frequency .............................. 47~63Hz
Inrush current .................................. cold start, 20A/115V, 40A/230V Inrush current .................................. cold start, 40A/230V
Input leakage current ...................... 1mA/ 230VAC Input leakage current ...................... 0.7mA/ 230VAC
Line regulation (full load) ................. 0.5% Line regulation (full load) ................. 0.5%
Output voltage adjust range ........... 10% Output voltage adjust range ........... 10%
Output overload protection ............. 105~150%, current limiting, auto recovery Output overload protection ............. 110~130%, current limiting, auto recovery
Output over voltage protection ....... 115~150%, shut off, re-power on to recover Output over voltage protection ....... 115~150%, shut off, re-power on to recover
Withstand voltage ........................... I/P -O/P: 3.0KVAC/1min Withstand voltage ........................... I/P-O/P:1.5KVAC/1min;I/P-F/G:1.5KVAC/1min
I/P -F/G: 1.5KVAC/1min O/P-F/G:0.5KVAC/1min
O/P-F/G: 0.5KVAC/1min Rise time ......................................... 50ms@full load (typical)
Rise, Hold up time .......................... 50ms, 20ms@full load (typical) Hold up time .................................... 20ms@full load (typical)
Operating temperature ................... -20 ~+50 Operating temperature ................... -20 ~+50
Safety standards ............................ GB4943, UL60950, EN60950 Safety standards ............................ design refer to GB4943, UL60950, EN60950
EMC standards ............................... GB9254, EN55022 classB, EN55024 EMC standards ............................... design refer to GB9254, EN55022 classA
EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11 Cooling method ............................... fan
Cooling method ............................... fan Packing ........................................... 1.20kg/pcs, 16pcs/CTN
Packing ........................................... 0.81kg/pcs, 22pcs/CTN

Model DC Output Load regul. R&N Efficiency Model DC Output Load regul. R&N Efficiency
HF200W-SC-3.3 3.3V 40.0A 0.5% 100mV 70% HF300W-S-5 5V 60.0A 0.5% 120mV 78%
HF200W-SC-5 5V 40.0A 0.5% 100mV 76% HF300W-S-12 12V 25.0A 0.5% 150mV 84%
HF200W-SC-7.5 7.5V 26.7A 0.5% 100mV 80% HF300W-S-24 24V 12.5A 0.5% 150mV 87%
HF200W-SC-12 12V 16.7A 0.5% 120mV 81% HF300W-S-48 48V 6.3A 0.5% 240mV 88%
HF200W-SC-13.5 13.5V 15.0A 0.5% 120mV 82% HF400W-S-12 12V 33.0A 0.5% 150mV 83%
HF200W-SC-15 15V 13.5A 0.5% 120mV 83% HF400W-S-24 24V 17.0A 0.5% 150mV 86%
HF200W-SC-24 24V 8.4A 0.5% 150mV 84% HF400W-S-36 36V 11.0A 0.5% 200mV 87%
HF200W-SC-48 48V 4.2A 0.5% 150mV 85% HF400W-S-48 48V 8.3A 0.5% 240mV 85%
* 3~48VDC output all available. * 3~48VDC output all available.
320W~350W Single Output Standard Series
320W Single Output Series with PFC 350W Single Output Standard with approval
Universal AC input / full range AC input range selected by switch
PF>0.98@115VAC; >0.94@230VAC High reliability
Built in fan speed control Approvals: CE (LVD)
Approvals: UL/ CB/ CE/ CCC Built in fan speed control
Protections: overload/ over voltage/ Protections: overload/ over voltage/
over temperature/ short circuit over temperature/ short circuit
5 years limited warranty 5 years limited warranty
F632C 215 x 115 x 50(mm) F632C 215 x 115 x 50(mm)

AC input voltage range ................... 85~264VAC (120~370VDC) AC input voltage range ................... 85~132/ 170~264VAC selected by switch
Input frequency .............................. 47~63Hz Input frequency .............................. 47~63Hz
Inrush current .................................. cold start, 20A/115V, 40A/230V Inrush current .................................. cold start, 20A/115V, 40A/230V
Input leakage current ...................... 1mA/ 230VAC Input leakage current ...................... 1mA/ 230VAC
Line regulation (full load) ................. 0.5% Line regulation (full load) ................. 0.5%
Output voltage adjust range ........... 10% Output voltage adjust range ........... 10%
Output overload protection ............. 105~150%, hiccup mode, auto recovery Output overload protection ............. 110~130%, shut off, re-power on to recover
Output over voltage protection ....... 115~150%, shut off, re-power on to recover Output over voltage protection ....... 115~150%, shut off, re-power on to recover
Withstand voltage ........................... I/P-O/P:3.0KVAC/1min;I/P-F/G:1.5KVAC/1min Withstand voltage ........................... I/P-O/P:3.0KVAC/1min;I/P-F/G:1.5KVAC/1min
O/P-F/G:0.5KVAC/1min O/P-F/G:0.5KVAC/1min
Rise, Hold up time .......................... 50ms, 20ms@full load (typical) Rise time ......................................... 50ms@full load (typical)
Operating temperature ................... -20 ~+50 Hold up time .................................... 20ms@full load (typical)
Safety standards ............................ GB4943, UL60950, EN60950 Operating temperature ................... -20 ~+50
EMC standards ............................... GB9254, EN55022 classB, EN55024 Safety standards ............................ meet GB4943, UL60950, EN60950
EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11 EMC standards ............................... meet GB9254, EN55022 classA
Cooling method ............................... fan Cooling method ............................... fan
Packing ........................................... 1.06kg/pcs, 20pcs/CTN Packing ........................................... 0.98kg/pcs, 20pcs/CTN

Model DC Output Load regul. R&N Efficiency Model DC Output Load regul. R&N Efficiency
HF320W-SC-5 5V 60.0A 0.5% 120mV 78% HF350W-SF-5 5V 60.0A 0.5% 120mV 77%
HF320W-SC-7.5 7.5V 40.0A 0.5% 120mV 78% HF350W-SF-7.5 7.5V 40.0A 0.5% 120mV 80%
HF320W-SC-12 12V 25.0A 0.5% 150mV 83% HF350W-SF-12 12V 29.0A 0.5% 150mV 82%
HF320W-SC-13.5 13.5V 22.0A 0.5% 150mV 83% HF350W-SF-13.5 13.5V 25.8A 0.5% 150mV 84%
HF320W-SC-15 15V 20.0A 0.5% 150mV 84% HF350W-SF-15 15V 23.2A 0.5% 150mV 83%
HF320W-SC-24 24V 13.0A 0.5% 150mV 86% HF350W-SF-24 24V 14.6A 0.5% 150mV 85%
HF320W-SC-27 27V 11.7A 0.5% 200mV 87% HF350W-SF-27 27V 13.0A 0.5% 200mV 84%
HF320W-SC-48 48V 6.7A 0.5% 240mV 88% HF350W-SF-48 48V 7.3A 0.5% 240mV 87%
* 3~48VDC output all available. * 3~48VDC output all available.

320W PFC Series - Voltage Programmable 350W Single Output Standard Series
Universal AC input / full range High reliability
Built-in active PFC, PF>0.92@230VAC Built in fan speed control
Output voltage programmable from Protections: overload/ over voltage/
20~110% by 0~5VDC external signal over temperature/ short circuit
Protections: overload/ over voltage/ 5 years limited warranty
over temperature/ short circuit F632C 215 x 115 x 50(mm)
5 years limited warranty
F632C 215 x 115 x 50(mm)

AC input voltage range ................... 170~264VAC (210~370VDC)


Input frequency .............................. 47~63Hz
AC input voltage range ................... 88~264VAC (124~370VDC) Inrush current .................................. cold start, 40A/230V
Input frequency .............................. 47~63Hz Input leakage current ...................... 0.7mA/ 230VAC
Inrush current .................................. cold start, 60A/230V Line regulation (full load) ................. 0.5%
Input leakage current ...................... 1mA/ 230VAC Output voltage adjust range ........... 10%
Line regulation (full load) ................. 0.5% Output overload protection ............. 110~130%, shut off, re-power on to recover
Output voltage adjust range ........... 10% Output over voltage protection ....... 115~150%, shut off, re-power on to recover
Output overload protection ............. 105~150%, hiccup mode, auto recovery Withstand voltage ........................... I/P -O/P: 1.5KVAC/1min
Output over voltage protection ....... 115~150%, shut off, re-power on to recover I/P -F/G: 1.5KVAC/1min
Withstand voltage ........................... I/P -O/P: 3.0KVAC/1min O/P-F/G: 0.5KVAC/1min
I/P -F/G: 1.5KVAC/1min Rise time ......................................... 50ms@full load (typical)
O/P-F/G: 0.5KVAC/1min Hold up time .................................... 20ms@full load (typical)
Rise time ......................................... 50ms@full load (typical) Operating temperature ................... -20 ~+50
Hold up time .................................... 20ms@full load (typical) Safety standards ............................ design meet GB4943, UL60950, EN60950
Operating temperature ................... -20 ~+50 EMC standards ............................... design meet GB9254, EN55022 classA
Safety standards ............................ GB4943, UL60950, EN60950 Cooling method ............................... fan
EMC standards ............................... GB9254, EN55022 classB, EN55024 Packing ........................................... 0.98kg/pcs, 20pcs/CTN
EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11
Cooling method ............................... fan Model DC Output Load regul. R&N Efficiency
Packing ........................................... 1.05kg/pcs, 20pcs/CTN HF350W-S-5 5V 60.0A 0.5% 120mV 77%
HF350W-S-7.5 7.5V 40.0A 0.5% 120mV 80%
HF350W-S-12 12V 29.0A 0.5% 150mV 82%
HF350W-S-13.5 13.5V 25.8A 0.5% 150mV 83%
Model DC Output Load regul. R&N Efficiency HF350W-S-15 15V 23.2A 0.5% 150mV 84%
HF320W-SCR-12 12V 25.0A 0.5% 150mV 83.0% HF350W-S-24 24V 14.6A 0.5% 150mV 84%
HF320W-SCR-24 24V 12.5A 0.5% 150mV 85.0% HF350W-S-27 27V 13.0A 0.5% 200mV 86%
HF320W-SCR-48 48V 6.25A 0.5% 240mV 86.5% HF350W-S-48 48V 7.3A 0.5% 240mV 86%
* 12~48VDC output all available. * 3~48VDC output all available.
480~1000W Single / 10W Dual Output Series
480W Single Output Series with PFC 10W Dual Output Series
Standard
- with
withapproval
approval
Universal AC input / full range Universal AC input / full range
PF>0.98@115VAC; >0.94@230VAC High reliability
Built in remote sense (option) Approvals: CE
Remote ON/OFF control (option) Protections: overload/ over voltage/
Protections: overload/ over voltage/ short circuit
over temperature/ short circuit V1 is isolated from the other output
5 years limited warranty 5 years limited warranty
F648C 278 x 127 x 43(mm) F601 100 x 58 x 31(mm)
AC input voltage range ................... 85~264VAC (120~370VDC) AC input voltage range ................... 85~264VAC (120~370VDC)
Input frequency .............................. 47~63Hz Inrush current .................................. cold start, 15A/115V, 30A/230V
Inrush current .................................. cold start, 20A/115VAC, 40A/230VAC Input leakage current ...................... 0.7mA/ 230VAC
Input leakage current ...................... 1mA/ 230VAC Line regulation (full load) ................. 0.5%
Line regulation (full load) ................. 0.5% Load regulation ................................ V1: 0.5%, V2: 3% (with regulator);
Output voltage adjust range ........... 10% 10% (without)
Output overload protection ............. 110~130%, current limiting, auto recovery Output voltage adjust range ........... V1: 5% of rated output voltage
Output over voltage protection ....... 115~150%, shut off, re-power on to recover Output overload protection ............. built-in IC protection, hiccup mode,
Withstand voltage ........................... I/P -O/P: 3.0KVAC/1min auto recovery
I/P -F/G: 1.5KVAC/1min Output over voltage protection ....... clamping by zenor diode
O/P-F/G: 0.5KVAC/1min Withstand voltage ........................... I/P-O/P:3.0KVAC/1min;I/P-F/G:1.5KVAC/1min
Rise time ......................................... 50ms@full load (typical) O/P-F/G:0.5KVAC/1min
Hold up time .................................... 20ms@full load (typical) Rise, Hold up time .......................... 50ms, 20ms@full load (typical)
Operating temperature ................... -20 ~+50 Operating temperature ................... -20 ~+50
Safety standards ............................ meet GB4943, UL60950, EN60950 Safety standards ............................ GB4943, UL60950, EN60950
EMC standards ............................... meet GB9254, EN55022 classB, EN55024 EMC standards ............................... GB9254, EN55022 classB, EN55024
EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11 EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11
Cooling method ............................... fan Cooling method ............................... convection
Packing ........................................... 1.62kg/pcs, 10pcs/CTN
Model DC Output R&N Efficiency
5V 0.20~1.8A 80mV
HF10W-DL-A 67%
5V 0.10~1.0A 100mV
Model DC Output Load regul. R&N Efficiency 5V 0.20~1.8A 80mV
HF10W-DL-B 69%
HF480W-SC-12 12V 43A 0.5% 150mV 85% 12V 0.10~0.5A 120mV
HF480W-SC-15 15V 35A 0.5% 150mV 85% 5V 0.20~1.8A 80mV
HF10W-DL-C 70%
HF480W-SC-24 24V 22A 0.5% 150mV 87% 15V 0.10~0.5A 120mV
HF480W-SC-48 48V 11A 0.5% 240mV 89% 5V 0.20~1.8A 80mV
HF10W-DL-D 72%
* 12~48VDC output all available. 24V 0.05~0.3A 150mV

500~1000W Single Output Standard Series 10W Dual Output Series


Standard Series
High reliability, low cost High reliability, low cost
Forced air cooling by built-in fan Built-in EMI filter
100% full load burn-in test 100% full load burn-in test
Protections: overload/ over voltage/ Protections: overload/ short circuit
over temperature/ short circuit V1 is isolated from the other output
5 years limited warranty 5 years limited warranty
F650 250 x 160 x 87(mm) F601 100 x 58 x 31(mm)

AC input voltage range ................... 170~264VAC (210~370VDC) AC input voltage range ................... 170~264VAC (210~370VDC)
Input frequency .............................. 47~63Hz Inrush current .................................. cold start, 30A/230V
Inrush current .................................. 60A/230V Input leakage current ...................... 0.7mA/ 230VAC
Input leakage current ...................... 1mA/ 230VAC Line regulation (full load) ................. 0.5%
Line regulation (full load) ................. 0.5% Load regulation ................................ V1: 0.5%, V2: 3% (with regulator);
Output voltage adjust range ........... 10% 10% (without)
Output overload protection ............. 110~130%, current limiting, auto recovery Output voltage adjust range ........... V1: 5% of rated output voltage
Output over voltage protection ....... 115~150%, shut off, re-power on to recover Output overload protection ............. 105~150%, hiccup mode, auto recovery
Withstand voltage ........................... I/P-O/P:1.5KVAC/1min;I/P-F/G:1.5KVAC/1min Withstand voltage ........................... I/P -O/P: 1.5KVAC/1min
O/P-F/G:0.5KVAC/1min I/P -F/G: 1.5KVAC/1min
Rise, Hold up time .......................... 50ms, 20ms@full load (typical) O/P-F/G: 0.5KVAC/1min
Operating temperature ................... -20 ~+50 Rise time ......................................... 50ms@full load (typical)
Safety standards ............................ design refer to GB4943, UL60950, EN60950 Hold up time .................................... 20ms@full load (typical)
EMC standards ............................... design refer to GB9254, EN55022 classA Operating temperature ................... -20 ~+50
Cooling method ............................... fan Safety standards ............................ design meet GB4943, UL60950, EN60950
Packing ........................................... 2.8~3.0kg/pcs, 6pcs/CTN EMC standards ............................... design meet GB9254, EN55022 classA
EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11
Model DC Output Load regul. R&N Efficiency
Cooling method ............................... convection
HF500W-S-12 12V 42.0A 0.5% 150mV 83%
HF500W-S-24 24V 21.0A 0.5% 150mV 84% Model DC Output R&N Efficiency
HF600W-S-24 24V 25.0A 0.5% 150mV 86% 5V 0.20~1.8A 50mV
80mV
HF10W-D-A 67%
HF600W-S-48 48V 13.0A 0.5% 240mV 88% 5V 0.10~1.0A 100mV
80mV
HF700W-S-48 48V 15.0A 0.5% 240mV 88% 5V 0.20~1.8A 50mV
80mV
HF10W-D-B 69%
HF800W-S-24 24V 33.0A 0.5% 150mV 84% 12V 0.10~0.5A 100mV
120mV
HF800W-S-48 48V 17.0A 0.5% 240mV 88% 5V 0.20~1.8A 50mV
80mV
HF10W-D-C 70%
HF900W-S-30 30V 30.0A 0.5% 200mV 86% 15V 0.10~0.5A 100mV
120mV
HF1000W-S-24 24V 42.0A 0.5% 150mV 84% 5V 0.20~1.8A 50mV
80mV
HF10W-D-D 72%
HF1000W-S-48 48V 21.0A 0.5% 240mV 88% 24V 0.05~0.3A 100mV
150mV
20W~35W Dual Output Standard Series
20W Dual Output Series
Standard
- with
withapproval
approval 30W Dual Output Series
Standard
- with
withapproval
approval
Universal AC input / full range AC input range selected by switch
High reliability High reliability
Approvals: CE Approvals: CE
Protections: overload/ over voltage/ Protections: overload/ over voltage/
short circuit short circuit
V1 is isolated from the other output V1 is isolated from the other output
5 years limited warranty 5 years limited warranty
F602 111 x 78 x 36(mm) F603 129 x 98 x 40(mm)

AC input voltage range ................... 85~264VAC (120~370VDC) AC input voltage range ................... 85~132/ 170~264VAC selected by switch
Inrush current .................................. cold start, 15A/115V, 30A/230V Inrush current .................................. cold start, 20A/115V, 40A/230V
Input leakage current ...................... 1mA/ 230VAC Input leakage current ...................... 1mA/ 230VAC
Line regulation (full load) ................. 0.5% Line regulation (full load) ................. 0.5%
Load regulation ................................ V1: 0.5%, V2: 3% (with regulator); Load regulation ................................ V1: 0.5%, V2: 3% (with regulator);
10% (without) 10% (without)
Output voltage adjust range ........... V1: 5% of rated output voltage Output voltage adjust range ........... V1: 5% of rated output voltage
Output overload protection ............. built-in IC protection, hiccup mode, Output overload protection ............. 105~150%
auto recovery Output over voltage protection ....... 115~150%, shut off, re-power on to recover
Output over voltage protection ....... clamping by zenor diode Withstand voltage ........................... I/P-O/P:3.0KVAC/1min;I/P-F/G:1.5KVAC/1min
Withstand voltage ........................... I/P-O/P:3.0KVAC/1min;I/P-F/G:1.5KVAC/1min O/P-F/G:0.5KVAC/1min
O/P-F/G:0.5KVAC/1min Rise time ......................................... 50ms@full load (typical)
Rise, Hold up time .......................... 50ms, 20ms@full load (typical) Hold up time .................................... 20ms@full load (typical)
Operating temperature ................... -20 ~+50 Operating temperature ................... -20 ~+50
Safety standards ............................ GB4943, UL60950, EN60950 Safety standards ............................ GB4943, UL60950, EN60950
EMC standards ............................... GB9254, EN55022 classB, EN55024 EMC standards ............................... GB9254, EN55022 classB, EN55024
EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11 EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11
Cooling method ............................... convection Cooling method ............................... convection

Model DC Output R&N Efficiency Model DC Output R&N Efficiency


5V 0.4~3.0A 50mV
80mV 5V 0.5~4.0A 50mV
80mV
HF20W-DL-A 69% HF30W-DF-A 68%
5V 0.2~1.5A 100mV
50mV 5V 0.0~1.5A 100mV
50mV
5V 0.4~3.0A 50mV
80mV 5V 0.5~4.0A 50mV
80mV
HF20W-DL-B 70% HF30W-DF-B 69%
12V 0.0~1.0A 120mV
80mV 12V 0.0~1.5A 120mV
80mV
5V 0.4~3.0A 50mV
80mV 5V 0.5~4.0A 50mV
80mV
HF20W-DL-C 71% HF30W-DF-C 72%
15V 0.0~1.0A 120mV
80mV 24V 0.0~1.0A 100mV
150mV
5V 0.4~3.0A 50mV
80mV 12V 0.2~2.0A 120mV
80mV
HF20W-DL-D 72% HF30W-DF-D 68%
24V 0.1~0.7A 100mV
150mV 12V 0.0~1.5A 120mV
80mV

20W Dual Output Series


Standard Series 35W Dual Output Series
Standard Series
High reliability, low cost High reliability, low cost
Built-in EMI filter Built-in EMI filter
100% full load burn-in test 100% full load burn-in test
Protections: overload/ short circuit Protections: overload/ short circuit
V1 is isolated from the other output V1 is isolated from the other output
5 years limited warranty 5 years limited warranty
F602 111 x 78 x 36(mm) F603 129 x 98 x 40(mm)

AC input voltage range ................... 170~264VAC (210~370VDC) AC input voltage range ................... 170~264VAC (210~370VDC)
Inrush current .................................. cold start, 30A/230V Inrush current .................................. cold start, 40A/230V
Input leakage current ...................... 0.7mA/ 230VAC Input leakage current ...................... 0.7mA/ 230VAC
Line regulation (full load) ................. 0.5% Line regulation (full load) ................. 0.5%
Load regulation ................................ V1: 0.5%, V2: 3% (with regulator); Load regulation ................................ V1: 0.5%, V2: 3% (with regulator);
10% (without) 10% (without)
Output voltage adjust range ........... V1: 5% of rated output voltage Output voltage adjust range ........... V1: 5% of rated output voltage
Output overload protection ............. 105~150% Output overload protection ............. 105~150%
Withstand voltage ........................... I/P -O/P: 1.5KVAC/1min Withstand voltage ........................... I/P -O/P: 1.5KVAC/1min
I/P -F/G: 1.5KVAC/1min I/P -F/G: 1.5KVAC/1min
O/P-F/G: 0.5KVAC/1min O/P-F/G: 0.5KVAC/1min
Rise time ......................................... 50ms@full load (typical) Rise time ......................................... 50ms@full load (typical)
Hold up time .................................... 20ms@full load (typical) Hold up time .................................... 20ms@full load (typical)
Operating temperature ................... -20 ~+50 Operating temperature ................... -20 ~+50
Safety standards ............................ design meet GB4943, UL60950, EN60950 Safety standards ............................ design meet GB4943, UL60950, EN60950
EMC standards ............................... design meet GB9254, EN55022 classA EMC standards ............................... design meet GB9254, EN55022 classA
EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11 EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11
Cooling method ............................... convection Cooling method ............................... convection

Model DC Output R&N Efficiency Model DC Output R&N Efficiency


5V 0.4~3.0A 50mV
80mV 5V 0.5~4.0A 50mV
80mV
HF20W-D-A 68% HF35W-D-A 68%
5V 0.2~1.5A 100mV
50mV 5V 0.0~2.0A 100mV
50mV
5V 0.4~3.0A 50mV
80mV 5V 0.5~4.0A 50mV
80mV
HF20W-D-B 69% HF35W-D-B 69%
12V 0.0~1.0A 120mV
80mV 12V 0.0~2.0A 120mV
80mV
5V 0.4~3.0A 50mV
80mV 5V 0.5~4.0A 50mV
80mV
HF20W-D-C 69% HF35W-D-C 72%
15V 0.0~1.0A 120mV
80mV 24V 0.0~1.0A 100mV
150mV
5V 0.4~3.0A 50mV
80mV 12V 0.2~2.0A 120mV
80mV
HF20W-D-D 71% HF35W-D-D 68%
24V 0.1~0.7A 100mV
150mV 12V 0.0~2.0A 120mV
80mV
40W~60W Dual Output Standard Series
40W Dual Output Series
Standard
- with
withapproval
approval 55W Dual Output Standard Series
Universal AC input / full range High reliability, low cost
High reliability Built-in EMI filter
Approvals: CE 100% full load burn-in test
Protections: overload/ over voltage/ Protections: overload/ short circuit
short circuit V1 is isolated from the other output
V1 is isolated from the other output 5 years limited warranty
5 years limited warranty F605 160 x 98 x 39(mm)
F603 129 x 98 x 40(mm)

AC input voltage range ................... 85~264VAC (120~370VDC) AC input voltage range ................... 170~264VAC (210~370VDC)
Inrush current .................................. cold start, 20A/115V, 40A/230V Inrush current .................................. cold start, 40A/230V
Input leakage current ...................... 1mA/ 230VAC Input leakage current ...................... 0.7mA/ 230VAC
Line regulation (full load) ................. 0.5% Line regulation (full load) ................. 0.5%
Load regulation ................................ V1: 0.5%, V2: 3% (with regulator); Load regulation ................................ V1: 0.5%, V2: 3% (with regulator);
10% (without) 10% (without)
Output voltage adjust range ........... V1: 5% of rated output voltage Output voltage adjust range ........... V1: 5% of rated output voltage
Output overload protection ............. 105~150%, hiccup mode, auto recovery Output overload protection ............. 105~150%, hiccup mode, auto recovery
Output over voltage protection ....... 115~150%, hiccup mode, auto recovery Withstand voltage ........................... I/P -O/P: 1.5KVAC/1min
Withstand voltage ........................... I/P -O/P: 3.0KVAC/1min I/P -F/G: 1.5KVAC/1min
I/P -F/G: 1.5KVAC/1min O/P-F/G: 0.5KVAC/1min
O/P-F/G: 0.5KVAC/1min Rise, Hold up time .......................... 50ms, 20ms@full load (typical)
Rise, Hold up time .......................... 50ms, 20ms@full load (typical) Operating temperature ................... -20 ~+50
Operating temperature ................... -20 ~+50 Safety standards ............................ design meet GB4943, UL60950, EN60950
Safety standards ............................ GB4943, UL60950, EN60950 EMC standards ............................... design meet GB9254, EN55022 classA
EMC standards ............................... GB9254, EN55022 classB, EN55024 EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11
EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11 Cooling method ............................... convection
Cooling method ............................... convection

Model DC Output R&N Efficiency Model DC Output R&N Efficiency


5V 0.5~5.0A 60mV
80mV 5V 0.5~6.0A 80mV
HF40W-DL-A 70% HF55W-D-A 68%
5V 0.4~2.0A 100mV
80mV 12V 0.0~2.5A 120mV
5V 0.5~5.0A 60mV
80mV 5V 0.5~6.0A 80mV
HF40W-DL-B 71% HF55W-D-B 70%
12V 0.2~2.0A 100mV
120mV 24V 0.0~1.5A 150mV
5V 0.5~5.0A 60mV
80mV 12V 0.2~4.0A 120mV
HF40W-DL-C 73% HF55W-D-C 70%
24V 0.0~1.5A 100mV
150mV 12V 0.0~2.5A 120mV
12V 0.2~2.5A 100mV
120mV 27V 0.1~1.5A 150mV
HF40W-DL-D 72% HF55W-D-D 73%
12V 0.0~1.5A 100mV
120mV 27V 0.0~1.5A 150mV

50W Dual Output Series


Standard
- with
withapproval
approval 60W Dual Output Standard with approval
AC input range selected by switch Universal AC input / full range
High reliability High reliability
Approvals: CE Approvals: CE
Protections: overload/ over voltage/ Protections: overload/ over voltage/
short circuit short circuit
V1 is isolated from the other output V1 is isolated from the other output
5 years limited warranty 5 years limited warranty
F605 160 x 98 x 39(mm) F605 160 x 98 x 39(mm)
AC input voltage range ................... 85~132/ 170~264VAC selected by switch AC input voltage range ................... 85~264VAC (120~370VDC)
Inrush current .................................. cold start, 20A/115V, 40A/230V Inrush current .................................. cold start, 20A/115V, 40A/230V
Input leakage current ...................... 1mA/ 230VAC Input leakage current ...................... 1mA/ 230VAC
Line regulation (full load) ................. 0.5% Line regulation (full load) ................. 0.5%
Load regulation ................................ V1: 0.5%, V2: 3% (with regulator); Load regulation ................................ V1: 0.5%, V2: 3% (with regulator);
10% (without) 10% (without)
Output voltage adjust range ........... V1: 5% of rated output voltage Output voltage adjust range ........... V1: 5% of rated output voltage
Output overload protection ............. 105~150% Output overload protection ............. 105~150%, hiccup mode, auto recovery
Output over voltage protection ....... 115~150%, shut off, re-power on to recover Output over voltage protection ....... 115~150%, hiccup mode, auto recovery
Withstand voltage ........................... I/P -O/P: 3.0KVAC/1min Withstand voltage ........................... I/P -O/P: 3.0KVAC/1min
I/P -F/G: 1.5KVAC/1min I/P -F/G: 1.5KVAC/1min
O/P-F/G: 0.5KVAC/1min O/P-F/G: 0.5KVAC/1min
Rise, Hold up time .......................... 50ms, 20ms@full load (typical) Rise, Hold up time .......................... 50ms, 20ms@full load (typical)
Operating temperature ................... -20 ~+50 Operating temperature ................... -20 ~+50
Safety standards ............................ GB4943, UL60950, EN60950 Safety standards ............................ GB4943, UL60950, EN60950
EMC standards ............................... GB9254, EN55022 classB, EN55024 EMC standards ............................... GB9254, EN55022 classB, EN55024
EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11 EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11
Cooling method ............................... convection Cooling method ............................... convection

Model DC Output R&N Efficiency Model DC Output R&N Efficiency


5V 0.5~6.0A 50mV
80mV 5V 0.5~6.0A 80mV
HF50W-DF-A 68% HF60W-DL-A 72%
12V 0.0~2.5A 100mV
120mV 12V 0.2~4.0A 120mV
5V 0.5~6.0A 50mV
80mV 5V 0.3~6.0A 80mV
HF50W-DF-B 70% HF60W-DL-B 75%
24V 0.0~1.5A 100mV
150mV 24V 0.0~2.0A 150mV
12V 0.2~4.0A 120mV
80mV 12V 0.3~4.0A 120mV
HF50W-DF-C 70% HF60W-DL-C 74%
12V 0.0~2.5A 100mV
120mV 12V 0.2~3.0A 120mV
27V 0.1~1.5A 100mV
150mV 15V 0.3~3.0A 120mV
HF50W-DF-D 73% HF60W-DL-D 74%
27V 0.0~1.5A 100mV
150mV 15V 0.2~2.5A 120mV
70W~100W Dual Output Standard Series
70W Dual Output Standard with approval 100W Dual Output Standard with approval
AC input range selected by switch AC input range selected by switch
Approvals: CE Approvals: CE
Protections: overload/ over voltage/ Protections: overload/ over voltage/
short circuit short circuit
V1 is isolated from the other output V1 is isolated from the other output
5 years limited warranty 5 years limited warranty
F605 160 x 98 x 39(mm) F610 199 x 98 x 39(mm)

AC input voltage range ................... 85~132/ 170~264VAC selected by switch AC input voltage range ................... 85~132/ 170~264VAC selected by switch
Inrush current .................................. cold start, 20A/115V, 40A/230V Inrush current .................................. cold start, 20A/115V, 40A/230V
Input leakage current ...................... 1mA/ 230VAC Input leakage current ...................... 1mA/ 230VAC
Line regulation (full load) ................. 0.5% Line regulation (full load) ................. 0.5%
Load regulation ................................ V1: 0.5%, V2: 3% (with regulator); Load regulation ................................ V1: 0.5%, V2: 3%
10% (without) Output voltage adjust range ........... V1: 5% of rated output voltage
Output voltage adjust range ........... V1: 5% of rated output voltage Output overload protection ............. 110~130%, shut off, re-power on to recover
Output overload protection ............. 105~150%, hiccup mode, auto recovery Output over voltage protection ....... 115~150%, shut off, re-power on to recover
Output over voltage protection ....... 115~150%, hiccup mode, auto recovery Withstand voltage ........................... I/P -O/P: 3.0KVAC/1min
Withstand voltage ........................... I/P -O/P: 3.0KVAC/1min I/P -F/G: 1.5KVAC/1min
I/P -F/G: 1.5KVAC/1min O/P-F/G: 0.5KVAC/1min
O/P-F/G: 0.5KVAC/1min Rise time ......................................... 50ms@full load (typical)
Rise time ......................................... 50ms@full load (typical) Hold up time .................................... 20ms@full load (typical)
Hold up time .................................... 20ms@full load (typical) Operating temperature ................... -20 ~+50
Operating temperature ................... -20 ~+50 Safety standards ............................ GB4943, UL60950, EN60950
Safety standards ............................ GB4943, UL60950, EN60950 EMC standards ............................... GB9254, EN55022 classB, EN55024
EMC standards ............................... GB9254, EN55022 classB, EN55024 EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11
EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11 Cooling method ............................... convection
Cooling method ............................... convection

Model DC Output R&N Efficiency Model DC Output R&N Efficiency


12V 0.2~5.0A 120mV 5V 2.0~15.0A 100mV
HF70W-DF-A 71% HF100W-DF-A 73%
12V 0.0~2.5A 120mV 12V 0.0~5.00A 120mV
12V 0.2~5.0A 120mV 5V 2.0~15.0A 100mV
HF70W-DF-B 72% HF100W-DF-B 74%
15V 0.0~2.0A 120mV 15V 0.0~4.00A 120mV
12V 0.2~5.0A 120mV 5V 2.0~15.0A 100mV
HF70W-DF-C 74% HF100W-DF-C 76%
24V 0.0~2.0A 150mV 24V 0.0~3.00A 150mV

70W Dual Output Standard Series 100W Dual Output Standard Series
High reliability, low cost High reliability, low cost
Built-in EMI filter Built-in EMI filter
100% full load burn-in test 100% full load burn-in test
Protections: overload/ short circuit Protections: overload/ short circuit
V1 is isolated from the other output V1 is isolated from the other output
5 years limited warranty 5 years limited warranty
F605 160 x 98 x 39(mm) F610 199 x 98 x 39(mm)

AC input voltage range ................... 170~264VAC (210~370VDC) AC input voltage range ................... 170~264VAC (210~370VDC)
Inrush current .................................. cold start, 40A/230V Inrush current .................................. cold start, 40A/230V
Input leakage current ...................... 0.7mA/ 230VAC Input leakage current ...................... 0.7mA/ 230VAC
Line regulation (full load) ................. 0.5% Line regulation (full load) ................. 0.5%
Load regulation ................................ V1: 0.5%, V2: 3% (with regulator); Load regulation ................................ V1: 0.5%, V2: 3%
10% (without) Output voltage adjust range ........... V1: 5% of rated output voltage
Output voltage adjust range ........... V1: 5% of rated output voltage Output overload protection ............. 110~130%, shut off, re-power on to recover
Output overload protection ............. 105~150%, hiccup mode, auto recovery Withstand voltage ........................... I/P -O/P: 1.5KVAC/1min
Withstand voltage ........................... I/P -O/P: 1.5KVAC/1min I/P -F/G: 1.5KVAC/1min
I/P -F/G: 1.5KVAC/1min O/P-F/G: 0.5KVAC/1min
O/P-F/G: 0.5KVAC/1min Rise time ......................................... 50ms@full load (typical)
Rise time ......................................... 50ms@full load (typical) Hold up time .................................... 20ms@full load (typical)
Hold up time .................................... 20ms@full load (typical) Operating temperature ................... -20 ~+50
Operating temperature ................... -20 ~+50 Safety standards ............................ design meet GB4943, UL60950, EN60950
Safety standards ............................ design meet GB4943, UL60950, EN60950 EMC standards ............................... design meet GB9254, EN55022 classA
EMC standards ............................... design meet GB9254, EN55022 classA EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11
EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11 Cooling method ............................... convection
Cooling method ............................... convection

Model DC Output R&N Efficiency Model DC Output R&N Efficiency


12V 0.2~5.0A 120mV 5V 2.0~15.0A 100mV
HF70W-D-A 71% HF100W-D-A 73%
12V 0.0~2.5A 120mV 12V 0.0~5.00A 120mV
12V 0.2~5.0A 120mV 5V 2.0~15.0A 100mV
HF70W-D-B 72% HF100W-D-B 74%
15V 0.0~2.0A 120mV 15V 0.0~4.00A 120mV
12V 0.2~5.0A 120mV 5V 2.0~15.0A 100mV
HF70W-D-C 74% HF100W-D-C 76%
24V 0.0~2.0A 150mV 24V 0.0~3.00A 150mV
150W~1000W Dual Output Standard Series
150W Dual Output Standard Series 300~400W Dual Output Standard Series
High reliability, low cost High reliability, low cost
Built-in EMI filter Built-in fan speed control
100% full load burn-in test 100% full load burn-in test
Protections: overload/ short circuit Protections: overload/ over voltage/
V1 is isolated from the other output over temperature/ short circuit
5 years limited warranty V1 is isolated from the other output
F615 199 x 98 x 50(mm) 5 years limited warranty
F630 241 x 124 x 65(mm)
AC input voltage range ................... 170~264VAC (210~370VDC) AC input voltage range ................... 170~264VAC (210~370VDC)
Inrush current .................................. cold start, 40A/230V Inrush current .................................. cold start, 40A/230V
Input leakage current ...................... 0.7mA/ 230VAC Input leakage current ...................... 0.7mA/ 230VAC
Line regulation (full load) ................. 0.5% Line regulation (full load) ................. 0.5%
Load regulation ................................ V1: 0.5%, V2: 3% Load regulation ................................ V1: 0.5%, V2: 3%
Output voltage adjust range ........... V1: 5% of rated output voltage Output voltage adjust range ........... V1: 5% of rated output voltage
Output overload protection ............. 110~130%, shut off, re-power on to recover Output overload protection ............. 110~130%, current limiting, auto recovery
Withstand voltage ........................... I/P -O/P: 1.5KVAC/1min Output over voltage protection ....... 115~150%, shut off, re-power on to recover
I/P -F/G: 1.5KVAC/1min Withstand voltage ........................... I/P -O/P: 1.5KVAC/1min
O/P-F/G: 0.5KVAC/1min I/P -F/G: 1.5KVAC/1min
Rise time ......................................... 50ms@full load (typical) O/P-F/G: 0.5KVAC/1min
Hold up time .................................... 20ms@full load (typical) Rise time ......................................... 50ms@full load (typical)
Operating temperature ................... -20 ~+50 Hold up time .................................... 20ms@full load (typical)
Safety standards ............................ design meet GB4943, UL60950, EN60950 Operating temperature ................... -20 ~+50
EMC standards ............................... design meet GB9254, EN55022 classA Safety standards ............................ design refer to GB4943, UL60950, EN60950
EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11 EMC standards ............................... design refer to GB9254, EN55022 classA
Cooling method ............................... convection Cooling method ............................... fan

Model DC Output R&N Efficiency Model DC Output R&N Efficiency


5V 2.0~18.0A 100mV 24V 2.0~12.0A 150mV
HF150W-D-A 74% HF300W-D-A 82%
12V 0.0~5.00A 120mV 5V 0.0~3.00A 100mV
5V 2.0~18.0A 100mV 24V 2.0~11.0A 150mV
HF150W-D-B 77% HF300W-D-B 83%
24V 0.0~3.00A 150mV 12V 0.0~3.00A 120mV
15V 1.0~8.00A 120mV 24V 2.0~16.0A 150mV
HF150W-D-C 79% HF400W-D-A 82%
15V 0.0~4.00A 120mV 12V 0.0~3.00A 120mV
24V 0.5~5.00A 150mV 27V 2.0~15.0A 200mV
HF150W-D-D 80% HF400W-D-B 83%
12V 0.0~4.00A 120mV 12V 0.0~3.00A 120mV

200W Dual Output Standard Series 500~1000W Dual Output Standard Series
High reliability, low cost High reliability, low cost
Built-in EMI filter Forced air cooling by built-in fan
100% full load burn-in test Protections: overload/ over voltage/
Protections: overload/ short circuit over temperature/ short circuit
V1 is isolated from the other output V1 is isolated from the other output
5 years limited warranty 5 years limited warranty
F620 200 x 110 x 50(mm) F650 250 x 160 x 87(mm)

AC input voltage range ................... 170~264VAC (210~370VDC) AC input voltage range ................... 170~264VAC (210~370VDC)
Inrush current .................................. cold start, 40A/230V Inrush current .................................. 60A/230V
Input leakage current ...................... 0.7mA/ 230VAC Input leakage current ...................... 0.7mA/ 230VAC
Line regulation (full load) ................. 0.5% Line regulation (full load) ................. 0.5%
Load regulation ................................ V1: 0.5%, V2: 3% Load regulation ................................ V1: 0.5%, V 2: 1%
Output voltage adjust range ........... V1: 5% of rated output voltage Output voltage adjust range ........... V1: 5% of rated output voltage
Output overload protection ............. 110~130%, shut off, re-power on to recover Output overload protection ............. 110~130%, current limiting, auto recovery
Withstand voltage ........................... I/P -O/P: 1.5KVAC/1min Output over voltage protection ....... 115~150%, shut off, re-power on to recover
I/P -F/G: 1.5KVAC/1min Withstand voltage ........................... I/P -O/P: 1.5KVAC/1min
O/P-F/G: 0.5KVAC/1min I/P -F/G: 1.5KVAC/1min
Rise time ......................................... 50ms@full load (typical) O/P-F/G: 0.5KVAC/1min
Hold up time .................................... 20ms@full load (typical) Rise time ......................................... 50ms@full load (typical)
Operating temperature ................... -20 ~+50 Hold up time .................................... 20ms@full load (typical)
Safety standards ............................ design meet GB4943, UL60950, EN60950 Operating temperature ................... -20 ~+50
EMC standards ............................... design meet GB9254, EN55022 classA Safety standards ............................ design refer to GB4943, UL60950, EN60950
EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11 EMC standards ............................... design refer to GB9254, EN55022 classA
Cooling method ............................... convection Cooling method ............................... fan

Model DC Output R&N Efficiency Model DC Output R&N Efficiency


24V 0.8~8.00A 150mV 24V 0.0~21.0A 150mV
HF200W-D-A 83% HF500W-D-A 82%
12V 0.0~3.00A 120mV 12V 0.0~3.00A 120mV
27V 0.6~7.00A 150mV 24V 0.0~30.0A 150mV
HF200W-D-B 83% HF800W-D-A 82%
12V 0.0~3.00A 120mV 12V 0.0~3.00A 120mV
36V 0.3~6.00A 150mV 28V 0.0~28.0A 200mV
HF200W-D-C 84% HF800W-D-B 83%
12V 0.0~3.00A 120mV 12V 0.0~3.00A 120mV
24V 0.8~8.00A 150mV 48V 0.0~20.0A 240mV
HF200W-D-D 82% HF1000W-D-A 84%
5V 0.0~3.00A 100mV 12V 0.0~3.00A 120mV
10W~20W Triple Output Standard Series
10W Triple Output Standard with approval 20W Triple Output Standard with approval
Universal AC input / full range Universal AC input / full range
High reliability High reliability
Approvals: CE Approvals: CE
Protections: overload/ over voltage/ Protections: overload/ over voltage/
short circuit short circuit
V1 is isolated from the other outputs V1 is isolated from the other outputs
5 years limited warranty 5 years limited warranty
F601 100 x 58 x 31(mm) F602 111 x 78 x 36(mm)
AC input voltage range ................... 85~264VAC (120~370VDC) AC input voltage range ................... 85~264VAC (120~370VDC)
Inrush current .................................. cold start, 15A/115V, 30A/230V Inrush current .................................. cold start, 15A/115V, 30A/230V
Input leakage current ...................... 1mA/ 230VAC Input leakage current ...................... 1mA/ 230VAC
Line regulation (full load) ................. 0.5% Line regulation (full load) ................. 0.5%
Load regulation ................................ V1: 0.5%, V2,V 3: 3% (with regulators); Load regulation ................................ V1: 0.5%, V2,V3: 3% (with regulators);
10% (without) 10% (without)
Output voltage adjust range ........... V1: 5% of rated output voltage Output voltage adjust range ........... V1: 5% of rated output voltage
Output overload protection ............. built-in IC protection, hiccup mode, Output overload protection ............. built-in IC protection, hiccup mode,
auto recovery auto recovery
Output over voltage protection ....... clamping by zenor diode Output over voltage protection ....... clamping by zenor diode
Withstand voltage ........................... I/P-O/P:3.0KVAC/1min;I/P-F/G:1.5KVAC/1min Withstand voltage ........................... I/P-O/P:3.0KVAC/1min;I/P-F/G:1.5KVAC/1min
O/P-F/G:0.5KVAC/1min O/P-F/G:0.5KVAC/1min
Rise, Hold up time .......................... 50ms, 20ms@full load (typical) Rise, Hold up time .......................... 50ms, 20ms@full load (typical)
Operating temperature ................... -20 ~+50 Operating temperature ................... -20 ~+50
Safety standards ............................ GB4943, UL60950, EN60950 Safety standards ............................ GB4943, UL60950, EN60950
EMC standards ............................... GB9254, EN55022 classB, EN55024 EMC standards ............................... GB9254, EN55022 classB, EN55024
EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11 EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11
Cooling method ............................... convection Cooling method ............................... convection

Model DC Output R&N Efficiency Model DC Output R&N Efficiency


5V 0.20~1.5A 80mV 5V 0.3~2.5A 80mV
HF10W-TL-A 12V 0.05~0.3A 120mV 70% HF20W-TL-A 12V 0.1~0.8A 120mV 71%
-12V 0.05~0.3A 120mV -12V 0.1~0.8A 120mV
5V 0.20~1.5A 80mV 5V 0.3~2.5A 80mV
HF10W-TL-B 15V 0.05~0.3A 120mV 71% HF20W-TL-B 15V 0.1~0.8A 120mV 72%
-15V 0.05~0.3A 120mV -15V 0.1~0.8A 120mV
5V 0.20~1.5A 80mV 5V 0.3~2.5A 80mV
HF10W-TL-C 12V 0.05~0.3A 120mV 68% HF20W-TL-C 12V 0.1~0.8A 120mV 69%
-5V 0.10~0.5A 100mV -5V 0.1~1.0A 100mV

10W Triple Output Standard Series 20W Triple Output Standard Series
High reliability, low cost High reliability, low cost
Built-in EMI filter Built-in EMI filter
100% full load burn-in test 100% full load burn-in test
Protections: overload/ short circuit Protections: overload/ short circuit
V1 is isolated from the other outputs V1 is isolated from the other outputs
5 years limited warranty 5 years limited warranty
F601 100 x 58 x 31(mm) F602 111 x 78 x 36(mm)

AC input voltage range ................... 170~264VAC (210~370VDC) AC input voltage range ................... 170~264VAC (210~370VDC)
Inrush current .................................. cold start, 30A/230V Inrush current .................................. cold start, 30A/230V
Input leakage current ...................... 0.7mA/ 230VAC Input leakage current ...................... 0.7mA/ 230VAC
Line regulation (full load) ................. 0.5% Line regulation (full load) ................. 0.5%
Load regulation ................................ V1: 0.5%, V2,V 3: 3% (with regulators); Load regulation ................................ V1: 0.5%, V2,V 3: 3% (with regulators);
10% (without) 10% (without)
Output voltage adjust range ........... V1: 5% of rated output voltage Output voltage adjust range ........... V1: 5% of rated output voltage
Output overload protection ............. 105~150%, hiccup mode, auto recovery Output overload protection ............. 105~150%
Withstand voltage ........................... I/P -O/P: 1.5KVAC/1min Withstand voltage ........................... I/P -O/P: 1.5KVAC/1min
I/P -F/G: 1.5KVAC/1min I/P -F/G: 1.5KVAC/1min
O/P-F/G: 0.5KVAC/1min O/P-F/G: 0.5KVAC/1min
Rise, Hold up time .......................... 50ms, 20ms@full load (typical) Rise, Hold up time .......................... 50ms, 20ms@full load (typical)
Operating temperature ................... -20 ~+50 Operating temperature ................... -20 ~+50
Safety standards ............................ design meet GB4943, UL60950, EN60950 Safety standards ............................ design meet GB4943, UL60950, EN60950
EMC standards ............................... design meet GB9254, EN55022 classA EMC standards ............................... design meet GB9254, EN55022 classA
EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11 EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11
Cooling method ............................... convection Cooling method ............................... convection
Model DC Output R&N Efficiency Model DC Output R&N Efficiency
5V 0.20~1.5A 80mV 5V 0.3~2.5A 80mV
HF10W-T-A 12V 0.05~0.3A 120mV 70% HF20W-T-A 12V 0.1~1.0A 120mV 68%
-12V 0.05~0.3A 120mV -12V 0.1~1.0A 120mV
5V 0.20~1.5A 80mV 5V 0.3~2.5A 80mV
HF10W-T-B 15V 0.05~0.3A 120mV 71% HF20W-T-B 15V 0.1~0.8A 120mV 69%
-15V 0.05~0.3A 120mV -15V 0.1~0.8A 120mV
5V 0.20~1.5A 80mV 5V 0.3~2.5A 80mV
HF10W-T-C 12V 0.05~0.3A 120mV 68% HF20W-T-C 12V 0.1~1.0A 120mV 68%
-5V 0.10~0.5A 100mV -5V 0.1~1.0A 100mV
30W~50W Triple Output Standard Series
30W Triple Output Standard with approval 40W Triple Output Standard with approval
AC input range selected by switch Universal AC input / full range
High reliability High reliability
Approvals: CE Approvals: CE
Protections: overload/ over voltage/ Protections: overload/ over voltage/
short circuit short circuit
V1 is isolated from the other outputs V1 is isolated from the other outputs
5 years limited warranty 5 years limited warranty
F603 129 x 98 x 40(mm) F603 129 x 98 x 40(mm)

AC input voltage range ................... 85~132/ 170~264VAC selected by switch AC input voltage range ................... 85~264VAC (120~370VDC)
Inrush current .................................. cold start, 20A/115V, 40A/230V Inrush current .................................. cold start, 20A/115V, 40A/230V
Input leakage current ...................... 1mA/ 230VAC Input leakage current ...................... 1mA/ 230VAC
Line regulation (full load) ................. 0.5% Line regulation (full load) ................. 0.5%
Load regulation ................................ V1: 0.5%, V2,V 3: 3% (with regulators); Load regulation ................................ V1: 0.5%, V2,V 3: 3% (with regulators);
10% (without) 10% (without)
Output voltage adjust range ........... V1: 5% of rated output voltage Output voltage adjust range ........... V1: 5% of rated output voltage
Output overload protection ............. 105~150% Output overload protection ............. 105~150%, hiccup mode, auto recovery
Output over voltage protection ....... 115~150%, shut off, re-power on to recover Output over voltage protection ....... 115~150%, hiccup mode, auto recovery
Withstand voltage ........................... I/P -O/P: 3.0KVAC/1min Withstand voltage ........................... I/P -O/P: 3.0KVAC/1min
I/P -F/G: 1.5KVAC/1min I/P -F/G: 1.5KVAC/1min
O/P-F/G: 0.5KVAC/1min O/P-F/G: 0.5KVAC/1min
Rise, Hold up time .......................... 50ms, 20ms@full load (typical) Rise, Hold up time .......................... 50ms, 20ms@full load (typical)
Operating temperature ................... -20 ~+50 Operating temperature ................... -20 ~+50
Safety standards ............................ GB4943, UL60950, EN60950 Safety standards ............................ GB4943, UL60950, EN60950
EMC standards ............................... GB9254, EN55022 classB, EN55024 EMC standards ............................... GB9254, EN55022 classB, EN55024
EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11 EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11
Cooling method ............................... convection Cooling method ............................... convection
Model DC Output R&N Efficiency Model DC Output R&N Efficiency
5V 0.5~3.5A 80mV 5V 0.5~4.0A 80mV
HF30W-TF-A 12V 0.1~1.2A 120mV 69% HF40W-TL-A 12V 0.2~1.5A 120mV 68%
-12V 0.1~0.8A 120mV -12V 0.2~1.5A 120mV
5V 0.5~3.5A 80mV 5V 0.5~4.0A 80mV
HF30W-TF-B 15V 0.1~0.8A 120mV 70% HF40W-TL-B 15V 0.0~1.0A 120mV 69%
-15V 0.0~0.5A 120mV -15V 0.1~1.0A 120mV
5V 0.5~3.5A 80mV 5V 0.5~4.0A 80mV
HF30W-TF-C 12V 0.1~1.2A 120mV 68% HF40W-TL-C 12V 0.2~1.5A 120mV 68%
-5V 0.0~1.0A 100mV -5V 0.2~1.5A 100mV

35W Triple Output Standard Series 50W Triple Output Standard with approval
High reliability, low cost AC input range selected by switch
Built-in EMI filter Approvals: CE
100% full load burn-in test Protections: overload/ over voltage/
Protections: overload/ short circuit short circuit
V1 is isolated from the other outputs V1 is isolated from the other outputs
5 years limited warranty 5 years limited warranty
F603 129 x 98 x 40(mm) F605 160 x 98 x 39(mm)

AC input voltage range ................... 170~264VAC (210~370VDC) AC input voltage range ................... 85~132/ 170~264VAC selected by switch
Inrush current .................................. cold start, 40A/230V Inrush current .................................. cold start, 20A/115V, 40A/230V
Input leakage current ...................... 0.7mA/ 230VAC Input leakage current ...................... 1mA/ 230VAC
Line regulation (full load) ................. 0.5% Line regulation (full load) ................. 0.5%
Load regulation ................................ V1: 0.5%, V2,V 3: 3% (with regulators); Load regulation ................................ V1: 0.5%, V2,V 3: 3% (with regulators);
10% (without) 10% (without)
Output voltage adjust range ........... V1: 5% of rated output voltage Output voltage adjust range ........... V1: 5% of rated output voltage
Output overload protection ............. 105~150% Output overload protection ............. 105~150%
Withstand voltage ........................... I/P -O/P: 1.5KVAC/1min Output over voltage protection ....... 115~150%, shut off, re-power on to recover
I/P -F/G: 1.5KVAC/1min Withstand voltage ........................... I/P -O/P: 3.0KVAC/1min
O/P-F/G: 0.5KVAC/1min I/P -F/G: 1.5KVAC/1min
Rise, Hold up time .......................... 50ms, 20ms@full load (typical) O/P-F/G: 0.5KVAC/1min
Operating temperature ................... -20 ~+50 Rise, Hold up time .......................... 50ms, 20ms@full load (typical)
Safety standards ............................ design meet GB4943, UL60950, EN60950 Operating temperature ................... -20 ~+50
EMC standards ............................... design meet GB9254, EN55022 classA Safety standards ............................ GB4943, UL60950, EN60950
EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11 EMC standards ............................... GB9254, EN55022 classB, EN55024
Cooling method ............................... convection EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11
Cooling method ............................... convection
Model DC Output R&N Efficiency Model DC Output R&N Efficiency
5V 0.5~3.5A 80mV 5V 0.5~5.0A 80mV
HF35W-T-A 12V 0.1~1.2A 120mV 69% HF50W-TF-A 12V 0.0~2.0A 120mV 68%
-12V 0.1~0.8A 120mV -12V 0.2~1.5A 120mV
5V 0.5~3.5A 80mV 5V 0.5~5.0A 80mV
HF35W-T-B 15V 0.1~0.8A 120mV 70% HF50W-TF-B 15V 0.0~2.0A 120mV 69%
-15V 0.0~0.5A 120mV -15V 0.0~1.0A 120mV
5V 0.5~3.5A 80mV 5V 0.6~7.0A 80mV
HF35W-T-C 12V 0.1~1.2A 120mV 68% HF50W-TF-C 12V 0.0~2.0A 120mV 68%
-5V 0.0~1.0A 100mV -5V 0.4~1.5A 100mV
55W~70W Triple Output Standard Series
55W Triple Output Standard Series 70W Triple Output Standard with approval
High reliability, low cost AC input range selected by switch
Built-in EMI filter High reliability
100% full load burn-in test Approvals: CE
Protections: overload/ short circuit Protections: overload/ over voltage/
V1 is isolated from the other outputs short circuit
5 years limited warranty V1 is isolated from the other outputs
F605 160 x 98 x 39(mm) 5 years limited warranty
F605 160 x 98 x 39(mm)

AC input voltage range ................... 170~264VAC (210~370VDC) AC input voltage range ................... 85~132/ 170~264VAC selected by switch
Inrush current .................................. cold start, 40A/230V Inrush current .................................. cold start, 20A/115V, 40A/230V
Input leakage current ...................... 0.7mA/ 230VAC Input leakage current ...................... 1mA/ 230VAC
Line regulation (full load) ................. 0.5% Line regulation (full load) ................. 0.5%
Load regulation ................................ V1: 0.5%, V2,V 3: 3% (with regulators); Load regulation ................................ V1: 0.5%, V 2,V 3: 3% (with regulators);
10% (without) 10% (without)
Output voltage adjust range ........... V1: 5% of rated output voltage Output voltage adjust range ........... V1: 5% of rated output voltage
Output overload protection ............. 105~150%, hiccup mode, auto recovery Output overload protection ............. 105~150%, hiccup mode, auto recovery
Withstand voltage ........................... I/P -O/P: 1.5KVAC/1min Output over voltage protection ....... 115~150%, hiccup mode, auto recovery
I/P -F/G: 1.5KVAC/1min Withstand voltage ........................... I/P -O/P: 3.0KVAC/1min
O/P-F/G: 0.5KVAC/1min I/P -F/G: 1.5KVAC/1min
Rise, Hold up time .......................... 50ms, 20ms@full load (typical) O/P-F/G: 0.5KVAC/1min
Operating temperature ................... -20 ~+50 Rise, Hold up time .......................... 50ms, 20ms@full load (typical)
Safety standards ............................ design meet GB4943, UL60950, EN60950 Operating temperature ................... -20 ~+50
EMC standards ............................... design meet GB9254, EN55022 classA Safety standards ............................ GB4943, UL60950, EN60950
EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11 EMC standards ............................... GB9254, EN55022 classB, EN55024
Cooling method ............................... convection EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11
Cooling method ............................... convection
Model DC Output R&N Efficiency Model DC Output R&N Efficiency
5V 0.5~5.0A 80mV 5V 0.5~6.0A 80mV
HF55W-T-A 12V 0.0~2.0A 120mV 68% HF70W-TF-A 12V 0.0~2.0A 120mV 71%
-12V 0.2~1.5A 120mV -12V 0.2~1.5A 120mV
5V 0.5~5.0A 80mV 5V 0.6~7.0A 80mV
HF55W-T-B 15V 0.0~2.0A 120mV 69% HF70W-TF-B 15V 0.0~2.0A 120mV 72%
-15V 0.0~1.0A 120mV -15V 0.0~1.0A 120mV
5V 0.6~7.0A 80mV 5V 0.7~8.0A 80mV
HF55W-T-C 12V 0.0~2.0A 120mV 68% HF70W-TF-C 12V 0.0~2.0A 120mV 70%
-5V 0.0~1.5A 100mV -5V 0.0~1.5A 100mV

60W Triple Output Standard with approval 70W Triple Output Standard Series
Universal AC input / full range High reliability, low cost
High reliability Built-in EMI filter
Approvals: CE 100% full load burn-in test
Protections: overload/ over voltage/ Protections: overload/ short circuit
short circuit V1 is isolated from the other outputs
V1 is isolated from the other outputs 5 years limited warranty
5 years limited warranty F605 160 x 98 x 39(mm)
F605 160 x 98 x 39(mm)
AC input voltage range ................... 85~264VAC (120~370VDC) AC input voltage range ................... 170~264VAC (210~370VDC)
Inrush current .................................. cold start, 20A/115V, 40A/230V Inrush current .................................. cold start, 40A/230V
Input leakage current ...................... 1mA/ 230VAC Input leakage current ...................... 0.7mA/ 230VAC
Line regulation (full load) ................. 0.5% Line regulation (full load) ................. 0.5%
Load regulation ................................ V1: 0.5%, V2,V 3: 3% (with regulators); Load regulation ................................ V1: 0.5%, V 2,V 3: 3% (with regulators);
10% (without) 10% (without)
Output voltage adjust range ........... V1: 5% of rated output voltage Output voltage adjust range ........... V1: 5% of rated output voltage
Output overload protection ............. 105~150%, hiccup mode, auto recovery Output overload protection ............. 105~150%, hiccup mode, auto recovery
Output over voltage protection ....... 115~150%, hiccup mode, auto recovery Withstand voltage ........................... I/P -O/P: 1.5KVAC/1min
Withstand voltage ........................... I/P -O/P: 3.0KVAC/1min I/P -F/G: 1.5KVAC/1min
I/P -F/G: 1.5KVAC/1min O/P-F/G: 0.5KVAC/1min
O/P-F/G: 0.5KVAC/1min Rise, Hold up time .......................... 50ms, 20ms@full load (typical)
Rise, Hold up time .......................... 50ms, 20ms@full load (typical) Operating temperature ................... -20 ~+50
Operating temperature ................... -20 ~+50 Safety standards ............................ design meet GB4943, UL60950, EN60950
Safety standards ............................ GB4943, UL60950, EN60950 EMC standards ............................... design meet GB9254, EN55022 classA
EMC standards ............................... GB9254, EN55022 classB, EN55024 EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11
EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11 Cooling method ............................... convection
Cooling method ............................... convection
Model DC Output R&N Efficiency Model DC Output R&N Efficiency
5V 0.5~6.0A 80mV 5V 0.5~6.0A 80mV
HF60W-TL-A 12V 0.0~2.0A 120mV 71% HF70W-T-A 12V 0.0~2.0A 120mV 71%
-12V 0.2~1.5A 120mV -12V 0.2~1.5A 120mV
5V 0.6~7.0A 80mV 5V 0.6~7.0A 80mV
HF60W-TL-B 15V 0.0~2.0A 120mV 72% HF70W-T-B 15V 0.0~2.0A 120mV 72%
-15V 0.0~1.0A 120mV -15V 0.0~1.0A 120mV
5V 0.7~8.0A 80mV 5V 0.7~8.0A 80mV
HF60W-TL-C 12V 0.0~2.0A 120mV 70% HF70W-T-C 12V 0.0~2.0A 120mV 70%
-5V 0.0~1.5A 100mV -5V 0.0~1.5A 100mV
100W~300W Triple Output Standard Series
100W Triple Output Standard with approval 150W Triple Output Standard Series
AC input range selected by switch High reliability, low cost
Approvals: CE Built-in EMI filter
Protections: overload/ over voltage/ 100% full load burn-in test
short circuit Protections: overload/ short circuit
V1 is isolated from the other outputs V1 is isolated from the other outputs
5 years limited warranty 5 years limited warranty
F610 199 x 98 x 39(mm) F615 199 x 98 x 50(mm)

AC input voltage range ................... 85~132/ 170~264VAC selected by switch AC input voltage range ................... 170~264VAC (210~370VDC)
Inrush current .................................. cold start, 20A/115V, 40A/230V Inrush current .................................. cold start, 40A/230V
Input leakage current ...................... 1mA/ 230VAC Input leakage current ...................... 0.7mA/ 230VAC
Line regulation (full load) ................. 0.5% Line regulation (full load) ................. 0.5%
Load regulation ................................ V1: 0.5%, V2,V 3: 3% Load regulation ................................ V1: 0.5%, V2,V 3: 3%
Output voltage adjust range ........... V1: 5% of rated output voltage Output voltage adjust range ........... V1: 5% of rated output voltage
Output overload protection ............. 110~130%, shut off, re-power on to recover Output overload protection ............. 110~130%
Output over voltage protection ....... 115~150%, shut off, re-power on to recover Withstand voltage ........................... I/P -O/P: 1.5KVAC/1min
Withstand voltage ........................... I/P -O/P: 3.0KVAC/1min I/P -F/G: 1.5KVAC/1min
I/P -F/G: 1.5KVAC/1min O/P-F/G: 0.5KVAC/1min
O/P-F/G: 0.5KVAC/1min Rise time ......................................... 50ms@full load (typical)
Rise time ......................................... 50ms@full load (typical) Hold up time .................................... 20ms@full load (typical)
Hold up time .................................... 20ms@full load (typical) Operating temperature ................... -20 ~+50
Operating temperature ................... -20 ~+50 Safety standards ............................ design meet GB4943, UL60950, EN60950
Safety standards ............................ GB4943, UL60950, EN60950 EMC standards ............................... design meet GB9254, EN55022 classA
EMC standards ............................... GB9254, EN55022 classB, EN55024 EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11
EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11 Cooling method ............................... convection
Cooling method ............................... convection

Model DC Output R&N Efficiency Model DC Output R&N Efficiency


5V 2.0~12.0A 100mV 24V 1.0~5.0A 150mV
HF100W-TF-A 12V 0.0~2.50A 120mV 73% HF150W-T-A 12V 0.0~2.5A 120mV 78%
-12V 0.0~1.50A 120mV 5V 0.0~2.0A 100mV
5V 2.0~12.0A 100mV 24V 1.0~5.0A 150mV
HF100W-TF-B 15V 0.0~2.50A 120mV 74% HF150W-T-B 12V 0.0~2.5A 120mV 80%
-15V 0.0~1.50A 120mV -12V 0.0~1.5A 120mV

100W Triple Output Standard Series 300W Triple Output Standard Series
High reliability, low cost High reliability, low cost
Built-in EMI filter Built in fan speed control
100% full load burn-in test 100% full load burn-in test
Protections: overload/ short circuit Protections: overload/ over voltage/
V1 is isolated from the other outputs over temperature/ short circuit
5 years limited warranty V1 is isolated from the other outputs
F610 199 x 98 x 39(mm) 5 years limited warranty
F630 241 x 124 x 65(mm)
AC input voltage range ................... 170~264VAC (210~370VDC) AC input voltage range ................... 170~264VAC (210~370VDC)
Inrush current ..................................
cold start, 40A/230V Inrush current .................................. cold start, 40A/230V
Input leakage current ...................... 0.7mA/ 230VAC Input leakage current ...................... 0.7mA/ 230VAC
Line regulation (full load) ................. 0.5% Line regulation (full load) ................. 0.5%
Load regulation ................................
V1: 0.5%, V2,V 3: 3% Load regulation ................................ V1: 0.5%, V2,V3: 3%
Output voltage adjust range ........... V1: 5% of rated output voltage Output voltage adjust range ........... V1: 5% of rated output voltage
Output overload protection ............. 110~130% Output overload protection ............. 110~130%, current limiting, auto recovery
Withstand voltage ........................... I/P -O/P: 1.5KVAC/1min Output over voltage protection ....... 115~150%, shut off, re-power on to recover
I/P -F/G: 1.5KVAC/1min Withstand voltage ........................... I/P -O/P: 1.5KVAC/1min
O/P-F/G: 0.5KVAC/1min I/P -F/G: 1.5KVAC/1min
Rise, Hold up time .......................... 50ms, 20ms@full load (typical) O/P-F/G: 0.5KVAC/1min
Operating temperature ................... -20 ~+50 Rise, Hold up time .......................... 50ms, 20ms@full load (typical)
Safety standards ............................ design meet GB4943, UL60950, EN60950 Operating temperature ................... -20 ~+50
EMC standards ............................... design meet GB9254, EN55022 classA Safety standards ............................ design refer to GB4943, UL60950, EN60950
EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11 EMC standards ............................... design refer to GB9254, EN55022 classA
Cooling method ............................... convection Cooling method ............................... fan

Model DC Output R&N Efficiency Model DC Output R&N Efficiency


5V 2.0~12.0A 100mV 24V 2.0~12.0A 150mV
HF100W-T-A 12V 0.0~2.50A 120mV 73% HF300W-T-A 12V 0.0~2.50A 120mV 84%
-12V 0.0~1.50A 120mV 12V 0.0~1.00A 120mV
5V 2.0~12.0A 100mV 27V 2.0~11.0A 200mV
HF100W-T-B 15V 0.0~2.50A 120mV 74% HF300W-T-B 12V 0.0~2.50A 120mV 84%
-15V 0.0~1.50A 120mV 5V 0.0~1.00A 100mV

For dual and triple output unit, it shows the output current The products are designed according to international
range (min. ~ max. ) of each output. But the total power shall
safety and EMC standards.
be within the rated power.
20W~100W Quad. Output Standard Series
20W Quad. Output Standard Series 55W Quad. Output Standard Series
High reliability, low cost High reliability, low cost
Built-in EMI filter Built-in EMI filter
100% full load burn-in test 100% full load burn-in test
Protections: overload/ short circuit Protections: overload/ short circuit
V1 is isolated from the other outputs V1 is isolated from the other outputs
5 years limited warranty 5 years limited warranty
F602 111 x 78 x 36(mm) F605 160 x 98 x 39(mm)

AC input voltage range ................... 170~264VAC (210~370VDC) AC input voltage range ................... 170~264VAC (210~370VDC)
Inrush current ..................................
cold start, 30A/230V Inrush current .................................. cold start, 40A/230V
Input leakage current ...................... 0.7mA/ 230VAC Input leakage current ...................... 0.7mA/ 230VAC
Line regulation (full load) ................. 0.5% Line regulation (full load) ................. 0.5%
Load regulation ................................
V1: 0.5%, V2,V3,V 4: 3% Load regulation ................................ V1: 0.5%, V2,V 3,V 4: 3%
Output voltage adjust range ........... V1: 5% of rated output voltage Output voltage adjust range ........... V1: 5% of rated output voltage
Output overload protection ............. 105~150% Output overload protection ............. 105~150%, hiccup mode, auto recovery
Withstand voltage ........................... I/P -O/P: 1.5KVAC/1min Withstand voltage ........................... I/P -O/P: 1.5KVAC/1min
I/P -F/G: 1.5KVAC/1min I/P -F/G: 1.5KVAC/1min
O/P-F/G: 0.5KVAC/1min O/P-F/G: 0.5KVAC/1min
Rise, Hold up time .......................... 50ms, 20ms@full load (typical) Rise, Hold up time .......................... 50ms, 20ms@full load (typical)
Operating temperature ................... -20 ~+50 Operating temperature ................... -20 ~+50
Safety standards ............................ design meet GB4943, UL60950, EN60950 Safety standards ............................ design meet GB4943, UL60950, EN60950
EMC standards ............................... design meet GB9254, EN55022 classA EMC standards ............................... design meet GB9254, EN55022 classA
Cooling method ............................... convection Cooling method ............................... convection
Model DC Output R&N Efficiency Model DC Output R&N Efficiency
5V 0.6~3.00A 80mV 5V 1.4~7.0A 80mV
12V 0~0.15A 120mV -5V 0.0~0.5A 100mV
HF20W-Q-A 64% HF55W-Q-A 66%
12V 0~0.15A 120mV 12V 0.0~1.0A 120mV
12V 0~0.15A 120mV -12V 0.0~0.5A 120mV
5V 0.6~3.00A 80mV 5V 0.8~4.0A 80mV
15V 0~0.10A 120mV 24V 0.0~1.0A 150mV
HF20W-Q-B 64% HF55W-Q-B 65%
15V 0~0.10A 120mV 12V 0.0~0.5A 120mV
15V 0~0.15A 120mV -12V 0.0~0.5A 120mV
5V 0.6~3.00A 80mV 5V 0.6~3.0A 80mV
5V 0~0.20A 100mV 24V 0.0~1.0A 150mV
HF20W-Q-C 62% HF55W-Q-C 66%
15V 0~0.10A 120mV 15V 0.0~0.5A 120mV
15V 0~0.10A 120mV -15V 0.0~0.5A 120mV

35W Quad. Output Standard Series 100W Quad. Output Standard Series
High reliability, low cost High reliability, low cost
Built-in EMI filter Built-in EMI filter
100% full load burn-in test 100% full load burn-in test
Protections: overload/ short circuit Protections: overload/ short circuit
V1 is isolated from the other outputs V1 is isolated from the other outputs
5 years limited warranty 5 years limited warranty
F603 129 x 98 x 40(mm) F610 199 x 98 x 39(mm)

AC input voltage range ................... 170~264VAC (210~370VDC) AC input voltage range ................... 170~264VAC (210~370VDC)
Inrush current ..................................
cold start, 40A/230V Input frequency .............................. 47~63Hz
Input leakage current ...................... 0.7mA/ 230VAC Inrush current .................................. cold start, 40A/230V
Line regulation (full load) ................. 0.5% Input leakage current ...................... 0.7mA/ 230VAC
Load regulation ................................
V1: 0.5%, V2,V3,V 4: 3% Line regulation (full load) ................. 0.5%
Output voltage adjust range ........... V1: 5% of rated output voltage Load regulation ................................ V1: 0.5%, V2,V 3,V 4: 3%
Output overload protection ............. 105~150% Output voltage adjust range ........... V1: 5% of rated output voltage
Withstand voltage ........................... I/P -O/P: 1.5KVAC/1min Output overload protection ............. 105~150%, shut off, re-power on to recover
I/P -F/G: 1.5KVAC/1min Withstand voltage ........................... I/P -O/P: 1.5KVAC/1min
O/P-F/G: 0.5KVAC/1min I/P -F/G: 1.5KVAC/1min
Rise, Hold up time .......................... 50ms, 20ms@full load (typical) O/P-F/G: 0.5KVAC/1min
Operating temperature ................... -20 ~+50 Rise time ......................................... 50ms@full load (typical)
Safety standards ............................ design meet GB4943, UL60950, EN60950 Hold up time .................................... 20ms@full load (typical)
EMC standards ............................... design meet GB9254, EN55022 classA Operating temperature ................... -20 ~+50
Cooling method ............................... convection Safety standards ............................ design meet GB4943, UL60950, EN60950
Model DC Output R&N Efficiency EMC standards ............................... design meet GB9254, EN55022 classA
Cooling method ............................... convection
5V 0.6~3.00A 80mV
12V 0.0~0.50A 120mV
HF35W-Q-A 65%
-12V 0.0~0.50A 120mV
24V 0.0~0.35A 150mV Model DC Output R&N Efficiency
5V 0.6~3.00A 80mV 5V 1.2~6.0A 100mV
15V 0.0~0.50A 120mV 24V 0~2.0A 150mV
HF35W-Q-B 65% HF100W-Q-A 82%
-15V 0.0~0.50A 120mV 15V 0~1.0A 120mV
12V 0.0~0.35A 120mV -15V 0~0.5A 120mV
5V 0.8~4.00A 80mV 5V 1.2~6.0A 100mV
5V 0.0~0.50A 100mV 24V 0~2.0A 150mV
HF35W-Q-C 64% HF100W-Q-B 82%
12V 0.0~0.50A 120mV 12V 0~1.0A 120mV
-12V 0.0~0.35A 120mV -12V 0~0.5A 120mV
150W Quad. / 20W Quin. Output / 25~40W M1 Series
150W Quad. Output Standard Series 25W Single Output M1 Series
High reliability, low cost Downsized design, 27mm height
Built-in EMI filter Universal AC input / full range
100% full load burn-in test High reliability
Protections: overload/ short circuit Protections: overload/ over voltage/
V1 is isolated from the other outputs short circuit
5 years limited warranty 5 years limited warranty
F615 199 x 98 x 50(mm) F6025M 120 x 75 x 27(mm)
AC input voltage range ................... 170~264VAC (210~370VDC)
Inrush current .................................. cold start, 40A/230V
Input leakage current ...................... 0.7mA/ 230VAC AC input voltage range ................... 85~264VAC (120~370VDC)
Line regulation (full load) ................. 0.5% Input frequency .............................. 47~63Hz
Load regulation ................................ V1: 0.5%, V2,V 3,V 4: 3% Inrush current .................................. cold start, 20A/115V, 40A/230V
Output voltage adjust range ........... V1: 5% of rated output voltage Input leakage current ...................... 1mA/ 230VAC
Output overload protection ............. 110~130%, shut off, re-power on to recover Line regulation (full load) ................. 0.5%
Withstand voltage ........................... I/P -O/P: 1.5KVAC/1min Output voltage adjust range ........... 10%
I/P -F/G: 1.5KVAC/1min Output overload protection ............. 105~150%, hiccup mode, auto recovery
O/P-F/G: 0.5KVAC/1min Output over voltage protection ....... 115~150%, hiccup mode, auto recovery
Rise, Hold up time .......................... 50ms, 20ms@full load (typical) Withstand voltage ........................... I/P -O/P: 3.0KVAC/1min
Operating temperature ................... -20 ~+50 I/P -F/G: 1.5KVAC/1min
Safety standards ............................ design meet GB4943, UL60950, EN60950 O/P-F/G: 0.5KVAC/1min
EMC standards ............................... design meet GB9254, EN55022 classA Rise time ......................................... 50ms@full load (typical)
Cooling method ............................... convection Hold up time .................................... 20ms@full load (typical)
Model DC Output R&N Efficiency Operating temperature ................... -20 ~+50
Safety standards ............................ meet GB4943, UL60950, EN60950
36V 0.5~2.5A 150mV
EMC standards ............................... meet GB9254, EN55022 classB
-24V 0~0.5A 150mV EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11
HF150W-Q-A 84%
17V 0~1.0A 150mV Cooling method ............................... convection
Weight ............................................ 0.23kg/pcs
5V 0~1.0A 100mV
5V 1.6~8.0A 100mV
12V 0~2.0A 120mV
HF150W-Q-B 82%
24V 0~2.0A 150mV Model DC Output Load regul. R&N Efficiency
-12V 0~2.0A 120mV HF25W-SML-5 5V 5.0A 0.5% 80mV 76%
5V 1.2~6.0A 100mV HF25W-SML-12 12V 2.1A 0.5% 120mV 82%
15V 0~3.0A 120mV HF25W-SML-24 24V 1.1A 0.5% 150mV 80%
HF150W-Q-C 82%
24V 0~2.0A 150mV HF25W-SML-48 48V 0.5A 0.5% 150mV 80%
-15V 0~2.0A 120mV * 3~48VDC output all available.

20W Quin. Output Standard Series 40W Single Output M1 Series


High reliability, low cost Compact size, high reliability
Built-in EMI filter Universal AC input / full range
100% full load burn-in test High reliability
Protections: overload/ short circuit Protections: overload/ over voltage/
V1 is isolated from the other outputs short circuit
5 years limited warranty 5 years limited warranty
F602 111 x 78 x 36(mm) F604M 120.6 x 63.5 x 38.1(mm)

AC input voltage range ................... 170~264VAC (210~370VDC)


Inrush current .................................. cold start, 30A/230V AC input voltage range ................... 85~264VAC (120~370VDC)
Input leakage current ...................... 0.7mA/ 230VAC Input frequency .............................. 47~63Hz
Line regulation (full load) ................. 0.5% Inrush current .................................. cold start, 20A/115V, 40A/230V
Load regulation ................................ V1: 0.5%, V2,V 3,V 4,V 5: 3% Input leakage current ...................... 1mA/ 230VAC
Output voltage adjust range ........... V1: 5% of rated output voltage Line regulation (full load) ................. 0.5%
Output overload protection ............. 105~150%, hiccup mode, auto recovery Output voltage adjust range ........... 10%
Withstand voltage ........................... I/P -O/P: 1.5KVAC/1min
Output overload protection ............. built-in IC protection, hiccup mode,
I/P -F/G: 1.5KVAC/1min auto recovery
O/P-F/G: 0.5KVAC/1min Output over voltage protection ....... 115~150%, hiccup mode, auto recovery
Rise time ......................................... 50ms@full load (typical) Withstand voltage ........................... I/P -O/P: 3.0KVAC/1min
Hold up time .................................... 20ms@full load (typical) I/P -F/G: 1.5KVAC/1min
Operating temperature ................... -20 ~+50
O/P-F/G: 0.5KVAC/1min
Safety standards ............................ design meet GB4943, UL60950, EN60950
Rise time ......................................... 50ms@full load (typical)
EMC standards ............................... design meet GB9254, EN55022 classA
Hold up time .................................... 20ms@full load (typical)
Cooling method ............................... convection
Operating temperature ................... -20 ~+50
Safety standards ............................ meet GB4943, UL60950, EN60950
Model DC Output R&N Efficiency EMC standards ............................... meet GB9254, EN55022 classB
5V 0.4~2.00A 80mV EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11
20V 0~0.10A 150mV Cooling method ............................... convection
Weight ............................................ 0.27kg/pcs
HF20W-M-A 20V 0~0.10A 150mV 62%
20V 0~0.15A 150mV
20V 0~0.15A 150mV Model DC Output Load regul. R&N Efficiency
5V 0.4~2.00A 80mV HF40W-SML-5 5V 8.0A 1.0% 80mV 78%
18V 0~0.15A 150mV HF40W-SML-12 12V 3.3A 0.5% 120mV 84%
HF20W-M-B 18V 0~0.15A 150mV 62% HF40W-SML-15 15V 2.7A 0.5% 120mV 84%
18V 0~0.15A 150mV HF40W-SML-24 24V 1.8A 0.5% 150mV 86%
18V 0~0.15A 150mV HF40W-SML-48 48V 0.8A 0.5% 150mV 87%
* 3~48VDC output all available.
30W M1 Series
30W 1~3 Output M1 Series 30W 1~3 Output M1 Series
Compact size, high reliability V1 is isolated from the other outputs Compact size, high reliability V1 is isolated from the other outputs
Universal AC input / full range Protections: overload/ short circuit Built-in EMI filter Protections: overload/ short circuit
100% full load burn-in test F602 111 x 78 x 36(mm) 100% full load burn-in test F602 111 x 78 x 36(mm)
5 years limited warranty 5 years limited warranty

HF30W-SML HF30W-DML, TML HF30W-SM HF30W-DM, TM

AC input voltage range ................... 85~264VAC (120~370VDC) AC input voltage range ................... 170~264VAC (210~370VDC)
Input frequency .............................. 47~63Hz Input frequency .............................. 47~63Hz
Inrush current .................................. cold start, 20A/115V, 40A/230V Inrush current .................................. cold start, 40A/230V
Input leakage current ...................... 0.7mA/ 230VAC Input leakage current ...................... 0.7mA/ 230VAC
Line regulation (full load) ................. 0.5% Line regulation (full load) ................. 0.5%
Load regulation ................................ V1: 1% Load regulation ................................ V1: 1%
V2,V 3: 10% V2,V 3: 10%
Output voltage adjust range ........... single output: 10%, multi-output: V1: 5% Output voltage adjust range ........... single output: 10%, multi-output: V1: 5%
Output overload protection ............. 105~150%, hiccup mode, auto recovery Output overload protection ............. 105~150%, hiccup mode, auto recovery
Withstand voltage ........................... I/P -O/P: 1.5KVAC/1min Withstand voltage ........................... I/P -O/P: 1.5KVAC/1min
I/P -F/G: 1.5KVAC/1min I/P -F/G: 1.5KVAC/1min
O/P-F/G: 0.5KVAC/1min O/P-F/G: 0.5KVAC/1min
Rise time ......................................... 50ms@full load (typical) Rise time ......................................... 50ms@full load (typical)
Hold up time .................................... 20ms@full load (typical) Hold up time .................................... 20ms@full load (typical)
Operating temperature ................... -20 ~+50 Operating temperature ................... -20 ~+50
Safety standards ............................ design meet GB4943, UL60950, EN60950 Safety standards ............................ design meet GB4943, UL60950, EN60950
EMC standards ............................... design meet GB9254, EN55022 classA EMC standards ............................... design meet GB9254, EN55022 classA
EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11 EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11
Cooling method ............................... convection Cooling method ............................... convection

Single Output Single Output


Model DC Output Load regul. R&N Efficiency Model DC Output Load regul. R&N Efficiency
HF30W-SML-5 5V 6.0A 0.5% 80mV 76% HF30W-SM-5 5V 6.0A 0.5% 80mV 76%
HF30W-SML-12 12V 2.5A 0.5% 120mV 83% HF30W-SM-12 12V 3.0A 0.5% 120mV 83%
HF30W-SML-15 15V 2.0A 0.5% 120mV 83% HF30W-SM-15 15V 2.4A 0.5% 120mV 83%
HF30W-SML-24 24V 1.3A 0.5% 150mV 84% HF30W-SM-24 24V 1.5A 0.5% 150mV 84%
HF30W-SML-48 48V 0.6A 0.5% 150mV 85% HF30W-SM-48 48V 0.7A 0.5% 150mV 86%
* 3~48VDC output all available. * 3~48VDC output all available.

Dual Output
Dual Output Model DC Output R&N Efficiency
Model DC Output R&N Efficiency 5V 0.5~4.0A 80mV
HF30W-DM-A 70%
5V 0.5~4.0A 80mV 12V 0.1~1.5A 120mV
HF30W-DML-A 70%
12V 0.1~1.5A 120mV 5V 0.5~4.0A 80mV
HF30W-DM-B 70%
5V 0.5~4.0A 80mV 24V 0.1~1.0A 150mV
HF30W-DML-B 70%
24V 0.1~1.0A 150mV 12V 0.2~2.0A 120mV
HF30W-DM-C 72%
12V 0.2~2.0A 120mV -12V 0.1~1.5A 120mV
HF30W-DML-C 72%
-12V 0.1~1.5A 120mV 5V 0.5~5.0A 80mV
HF30W-DM-D 67%
5V 0.3~1.5A 100mV

Triple Output Triple Output


Model DC Output R&N Efficiency Model DC Output R&N Efficiency
5V 0.5~3.5A 80mV 5V 0.5~3.5A 80mV
HF30W-TML-A 12V 0.1~1.2A 120mV 70% HF30W-TM-A 12V 0.1~1.2A 120mV 70%
-12V 0.1~0.7A 120mV -12V 0.1~0.7A 120mV
5V 0.5~3.5A 80mV 5V 0.5~3.5A 80mV
HF30W-TML-B 15V 0.1~0.8A 120mV 70% HF30W-TM-B 15V 0.1~0.8A 120mV 70%
-15V 0.1~0.5A 120mV -15V 0.1~0.5A 120mV
5V 0.5~3.5A 80mV 5V 0.5~3.5A 80mV
HF30W-TML-C 12V 0.1~1.2A 120mV 67% HF30W-TM-C 12V 0.1~1.2A 120mV 67%
-5V 0.2~1.0A 100mV -5V 0.2~1.0A 100mV
35W~50W M1 Series
35W 1~3 Output M1 Series 50W 1~3 Output M1 Series
Slim design, high reliability Compact size, high reliability V1 is isolated from the other outputs
V1 is isolated from the other outputs Universal AC input / full range Protections: overload/ short circuit
Built-in EMI filter 100% full load burn-in test F603 129 x 98 x 40(mm)
100% full load burn-in test 5 years limited warranty
Protections: overload/ short circuit
5 years limited warranty
F6035M 143 x 58 x 41(mm)

AC input voltage range ................... 170~264VAC (210~370VDC)


Input frequency .............................. 47~63Hz
Inrush current .................................. cold start, 40A/230V
Input leakage current ...................... 0.7mA/ 230VAC
Line regulation (full load) ................. 0.5%
Load regulation ................................ V1: 1%
V2,V 3: 10% HF50W-SML HF50W-DML, TML
Output voltage adjust range ........... single output: 10%, multi-output: V1: 5%
Output overload protection ............. 105~150%, hiccup mode, auto recovery
Withstand voltage ........................... I/P -O/P: 1.5KVAC/1min
I/P -F/G: 1.5KVAC/1min AC input voltage range ................... 85~264VAC (120~370VDC)
O/P-F/G: 0.5KVAC/1min Input frequency .............................. 47~63Hz
Rise time ......................................... 50ms@full load (typical) Inrush current .................................. cold start, 20A/115V, 40A/230V
Hold up time .................................... 20ms@full load (typical) Input leakage current ...................... 0.7mA/ 230VAC
Operating temperature ................... -20 ~+50 Line regulation (full load) ................. 0.5%
Safety standards ............................ design meet GB4943, UL60950, EN60950 Load regulation ................................ V1: 1%
EMC standards ............................... design meet GB9254, EN55022 classA V2,V3: 10%
Cooling method ............................... convection Output voltage adjust range ........... single output: 10%, multi-output: V1: 5%
Output overload protection ............. 105~150%, hiccup mode, auto recovery
Withstand voltage ........................... I/P -O/P: 1.5KVAC/1min
I/P -F/G: 1.5KVAC/1min
Single Output
O/P-F/G: 0.5KVAC/1min
Model DC Output Load regul. R&N Efficiency Rise time ......................................... 50ms@full load (typical)
HF35W-SM-5 5V 7.0A 0.5% 80mV 77% Hold up time .................................... 20ms@full load (typical)
Operating temperature ................... -20 ~+50
HF35W-SM-12 12V 3.0A 0.5% 120mV 81% Safety standards ............................ design meet GB4943, UL60950, EN60950
HF35W-SM-24 24V 1.5A 0.5% 150mV 84% EMC standards ............................... design meet GB9254, EN55022 classA
HF35W-SM-48 48V 0.7A 0.5% 150mV 86% EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11
Cooling method ............................... convection
* 3~48VDC output all available.

Dual Output
Model DC Output R&N Efficiency Single Output
5V 1~5.0A 80mV
HF35W-DM-A 68% Model DC Output Load regul. R&N Efficiency
5V 0~2.0A 100mV
HF50W-SML-5 5V 10.0A 0.5% 80mV 77%
5V 1~5.0A 80mV
HF35W-DM-B 69% HF50W-SML-12 12V 4.2A 0.5% 120mV 83%
12V 0~1.0A 120mV
HF50W-SML-15 15V 3.4A 0.5% 120mV 83%
5V 0.8~4.0A 80mV
HF35W-DM-C 70% HF50W-SML-24 24V 2.1A 0.5% 150mV 84%
15V 0~1.0A 120mV
HF50W-SML-48 48V 1.0A 0.5% 150mV 84%
* 3~48VDC output all available.
Triple Output
Model DC Output R&N Efficiency
5V 0.7~3.5A 80mV Dual Output
HF35W-TM-A 12V 0~1.0A 120mV 68% Model DC Output R&N Efficiency
-12V 0~0.5A 120mV 5V 1.0~6.0A 80mV
HF50W-DML-A 71%
5V 0.6~3.0A 80mV 12V 0.3~3.0A 120mV
HF35W-TM-B 15V 0~1.0A 120mV 70% 5V 1.0~6.0A 80mV
HF50W-DML-B 72%
-15V 0~0.5A 120mV 24V 0.2~2.0A 150mV
12V 0.4~2.0A 120mV
HF50W-DML-C 74%
-12V 0.1~2.0A 120mV
Over 50 product series have acquired UL,TUV,CB,CE ,
CCC approval, and more are underway.
Triple Output
Model DC Output R&N Efficiency
5V 0.6~5.0A 80mV
HF50W-TML-A 12V 0.1~1.2A 120mV 70%
-12V 0.1~0.7A 120mV
5V 0.6~5.0A 80mV
HF50W-TML-B 15V 0.1~0.8A 120mV 70%
-15V 0.1~0.5A 120mV
5V 0.6~5.0A 80mV
HF50W-TML-C 12V 0.1~1.2A 120mV 67%
CE Certificate TUV Certificate CB Certificate -5V 0.2~1.0A 100mV
50W~500W M1 Series
50W 1~3 Output M1 Series 60W Single Output M1 Series
Compact size, high reliability V1 is isolated from the other outputs Downsized design, 30mm height
Built-in EMI filter Protections: overload/ short circuit Universal AC input / full range
100% full load burn-in test F603 129 x 98 x 40(mm) High reliability
5 years limited warranty Protections: overload/ over voltage/
short circuit
5 years limited warranty
F606M 145 x 87 x 30(mm)

AC input voltage range ................... 85~264VAC (120~370VDC)


Input frequency .............................. 47~63Hz
Inrush current .................................. cold start, 20A/115V, 40A/230V
Input leakage current ...................... 1mA/ 230VAC
Line regulation (full load) ................. 0.5%
Output voltage adjust range ........... 10%
HF50W-SM HF50W-DM, TM Output overload protection ............. 105~150%, hiccup mode, auto recovery
Output over voltage protection ....... 115~150%, hiccup mode, auto recovery
Withstand voltage ........................... I/P -O/P: 3.0KVAC/1min
I/P -F/G: 1.5KVAC/1min
AC input voltage range ................... 170~264VAC (210~370VDC)
O/P-F/G: 0.5KVAC/1min
Input frequency .............................. 47~63Hz
Rise time ......................................... 50ms@full load (typical)
Inrush current .................................. cold start, 40A/230V
Hold up time .................................... 20ms@full load (typical)
Input leakage current ...................... 0.7mA/ 230VAC
Operating temperature ................... -20 ~+50
Line regulation (full load) ................. 0.5%
Safety standards ............................ meet GB4943, UL60950, EN60950
Load regulation ................................ V1: 1%
EMC standards ............................... meet GB9254, EN55022 classB
V2,V3: 10%
EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11
Output voltage adjust range ........... single output: 10%, multi-output: V1: 5%
Cooling method ............................... convection
Output overload protection ............. 105~150%, hiccup mode, auto recovery
Weight ............................................ 0.32kg/pcs
Withstand voltage ........................... I/P -O/P: 1.5KVAC/1min
I/P -F/G: 1.5KVAC/1min
O/P-F/G: 0.5KVAC/1min Model DC Output Load regul. R&N Efficiency
Rise time ......................................... 50ms@full load (typical)
Hold up time .................................... 20ms@full load (typical) HF60W-SML-5 5V 10.0A 0.5% 80mV 74%
Operating temperature ................... -20 ~+50 HF60W-SML-12 12V 5.0A 0.5% 120mV 82%
Safety standards ............................ design meet GB4943, UL60950, EN60950 HF60W-SML-15 15V 4.0A 0.5% 120mV 83%
EMC standards ............................... design meet GB9254, EN55022 classA
HF60W-SML-24 24V 2.5A 0.5% 150mV 84%
EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11
Cooling method ............................... convection HF60W-SML-48 48V 1.2A 0.5% 150mV 85%
* 5~48VDC output all available.

Single Output 500W Single Output M1 Series


Model DC Output Load regul. R&N Efficiency
HF50W-SM-5 5V 10.0A 0.5% 80mV 76% Compact size, high reliability
HF50W-SM-12 12V 4.2A 0.5% 120mV 81% Built-in fan speed control
100% full load burn-in test
HF50W-SM-15 15V 3.4A 0.5% 120mV 82%
Protections: overload/ over voltage/
HF50W-SM-24 24V 2.1A 0.5% 150mV 83% over temperature/ short circuit
HF50W-SM-48 48V 1.0A 0.5% 150mV 84% 5 years limited warranty
* 3~48VDC output all available. F630 241 x 124 x 65(mm)

Dual Output AC input voltage range ................... 170~264VAC (210~370VDC)


Model DC Output R&N Efficiency Input frequency .............................. 47~63Hz
5V 1.0~6.0A 80mV Inrush current .................................. 60A/230V
HF50W-DM-A 71% Input leakage current ...................... 1mA/ 230VAC
12V 0.3~3.0A 120mV Line regulation (full load) ................. 0.5%
5V 1.0~6.0A 80mV Output voltage adjust range ........... 10%
HF50W-DM-B 72% Output overload protection ............. 110~130%, current limiting, auto recovery
24V 0.2~2.0A 150mV
Output over voltage protection ....... 115~150%, shut off, re-power on to recover
12V 0.4~2.0A 120mV Withstand voltage ........................... I/P -O/P: 1.5KVAC/1min
HF50W-DM-C 74%
-12V 0.1~2.0A 120mV I/P -F/G: 1.5KVAC/1min
27V 0.1~1.5A 150mV O/P-F/G: 0.5KVAC/1min
HF50W-DM-D 76% Rise time ......................................... 50ms@full load (typical)
27V 0.1~1.0A 150mV
Hold up time .................................... 20ms@full load (typical)
Operating temperature ................... -20 ~+50
Triple Output Safety standards ............................ design meet GB4943, UL60950, EN60950
EMC standards ............................... design meet GB9254, EN55022 classA
Model DC Output R&N Efficiency Cooling method ............................... fan
5V 0.6~5.0A 80mV Packing ........................................... 1.32kg/pcs, 16pcs/CTN
HF50W-TM-A 12V 0.1~1.2A 120mV 70%
-12V 0.1~0.7A 120mV
5V 0.6~5.0A 80mV
HF50W-TM-B 15V 0.1~0.8A 120mV 70% Model DC Output Load regul. R&N Efficiency
-15V 0.1~0.5A 120mV HF500W-SM-5 5V 80A 1.0% 120mV 80%
5V 0.6~5.0A 80mV HF500W-SM-12 12V 42A 0.5% 150mV 84%
HF50W-TM-C 12V 0.1~1.2A 120mV 67% HF500W-SM-24 24V 21A 0.5% 150mV 85%
-5V 0.2~1.0A 100mV HF500W-SM-48 48V 10A 0.5% 240mV 86%
* 5~48VDC output all available.
600~1000W M1 Series / 20~40W Battery Charger
600W Single Output M1 Series 20W Battery Charging Power Supply
Compact size, high reliability To charge lead acid battery
AC input range selected by switch Auto switch when power off (UPS function)
Built-in fan speed control AC mains failure signal
Protections: overload/ over voltage/ Battery low signal
over temperature/ short circuit Approvals: CE
5 years limited warranty Protections: overload/ over voltage/
F660M 246 x 127 x 63.5(mm) short circuit
5 years limited warranty
F602 111 x 78 x 36(mm)

AC input voltage range ................... 90~132/ 180~264VAC selected by switch AC input voltage range ................... 85~264VAC (120~370VDC)
Input frequency .............................. 47~63Hz Input frequency .............................. 47~63Hz
Inrush current .................................. cold start, 30A/115V, 60A/230V Inrush current .................................. cold start, 15A/115V, 30A/230V
Input leakage current ...................... 1mA/ 230VAC Input leakage current ...................... 1mA/ 230VAC
Line regulation (full load) ................. 0.5% Line regulation (full load) ................. 0.5%
Output voltage adjust range ........... 10% Output voltage adjust range ........... V1: 5% of rated output voltage
Output overload protection ............. 105~150%, shut off, re-power on to recover V2: unadjustable
Output over voltage protection ....... 115~150%, shut off, re-power on to recover Output overload protection ............. built-in IC protection, hiccup mode,
Withstand voltage ........................... I/P -O/P: 3.0KVAC/1min auto recovery
I/P -F/G: 1.5KVAC/1min Output over voltage protection ....... 115~150%, hiccup mode, auto recovery
O/P-F/G: 0.5KVAC/1min Withstand voltage ........................... I/P -O/P: 3.0KVAC/1min
Rise time ......................................... 50ms@full load (typical) I/P -F/G: 1.5KVAC/1min
Hold up time .................................... 20ms@full load (typical) O/P-F/G: 0.5KVAC/1min
Operating temperature ................... -20 ~+50 Rise time ......................................... 50ms@full load (typical)
Safety standards ............................ meet GB4943, UL60950, EN60950 Hold up time .................................... 20ms@full load (typical)
EMC standards ............................... meet GB9254, EN55022 classA Operating temperature ................... -20 ~+50
Cooling method ............................... fan Safety standards ............................ GB4943, UL60950, EN60950
Weight ............................................ 2.12kg/pcs EMC standards ............................... GB9254, EN55022 classB, EN55024
EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11
Model DC Output Load regul. R&N Efficiency Cooling method ............................... convection
HF600W-SMF-5 5V 100A 0.5% 120mV 79% Packing ........................................... 0.27kg/pcs, 64pcs/CTN
HF600W-SMF-12 12V 50A 0.5% 150mV 84% Model DC Output R&N Efficiency
HF600W-SMF-15 15V 40A 0.5% 150mV 85% 12V 1.5A 120mV 71%
HF20W-SB-12
HF600W-SMF-24 24V 25A 0.5% 150mV 86% 13.8V 0.5A(Charger)
HF600W-SMF-27 27V 22.2A 0.5% 200mV 86% 24V 0.7A 150mV 68%
HF20W-SB-24
HF600W-SMF-48 48V 12.5A 0.5% 240mV 87% 27.1V 0.2A(Charger)

* 3~48VDC output all available.

1000W Single Output M1 Series 40W Battery Charging Power Supply


Compact size, high reliability To charge lead acid battery
Built-in fan speed control Auto switch when power off (UPS function)
100% full load burn-in test AC mains failure signal
Protections: overload/ over voltage/ Battery low signal
over temperature/ short circuit Approvals: CE
5 years limited warranty Protections: overload/ over voltage/
F6100M 253 x 160 x 69(mm) short circuit
5 years limited warranty
F603 129 x 98 x 40(mm)

AC input voltage range ................... 170~264VAC (210~370VDC) AC input voltage range ................... 85~264VAC (120~370VDC)
Input frequency .............................. 47~63Hz Input frequency .............................. 47~63Hz
Inrush current .................................. 60A/230V Inrush current .................................. cold start, 20A/115V, 40A/230V
Input leakage current ...................... 1mA/ 230VAC Input leakage current ...................... 1mA/ 230VAC
Line regulation (full load) ................. 0.5% Line regulation (full load) ................. 0.5%
Output voltage adjust range ........... 10% Output voltage adjust range ........... V1: 5% of rated output voltage
Output overload protection ............. 110~130%, current limiting, auto recovery V2: unadjustable
Output over voltage protection ....... 115~150%, shut off, re-power on to recover Output overload protection ............. built-in IC protection, hiccup mode,
Withstand voltage ........................... I/P -O/P: 1.5KVAC/1min auto recovery
I/P -F/G: 1.5KVAC/1min Output over voltage protection ....... 115~150%, hiccup mode, auto recovery
O/P-F/G: 0.5KVAC/1min Withstand voltage ........................... I/P -O/P: 3.0KVAC/1min
Rise time ......................................... 50ms@full load (typical) I/P -F/G: 1.5KVAC/1min
Hold up time .................................... 20ms@full load (typical) O/P-F/G: 0.5KVAC/1min
Operating temperature ................... -20 ~+50 Rise time ......................................... 50ms@full load (typical)
Safety standards ............................ design meet GB4943, UL60950, EN60950 Hold up time .................................... 20ms@full load (typical)
EMC standards ............................... design meet GB9254, EN55022 classA Operating temperature ................... -20 ~+50
Cooling method ............................... fan Safety standards ............................ GB4943, UL60950, EN60950
Weight ............................................ 2.86kg/pcs EMC standards ............................... GB9254, EN55022 classB, EN55024
EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11
Cooling method ............................... convection
Packing ........................................... 0.39kg/pcs, 42pcs/CTN

Model DC Output Load regul. R&N Efficiency Model DC Output R&N Efficiency
HF1000W-SM-12 12V 84A 1.0% 150mV 84% 13.8V 2.9A 120mV 78%
HF40W-SB-13.8
HF1000W-SM-24 24V 42A 0.5% 150mV 86% 13.4V 0.23A(Charger)
HF1000W-SM-28 28V 35A 0.5% 200mV 87% 27.6V 1.4A 150mV 76%
HF40W-SB-27.6
HF1000W-SM-48 48V 21A 0.5% 240mV 88% 26.5V 0.16A(Charger)
* 12~48VDC output all available.
55W~155W Battery Charger
55W Battery Charging Power Supply 100W Battery Charging Power Supply
To charge lead acid battery To charge lead acid battery
Auto switch when power off (UPS function) Auto switch when power off (UPS function)
AC mains failure signal AC mains failure signal
Battery low signal Battery low signal
Approvals: CE Approvals: CE
Protections: overload/ over voltage/ Protections: overload/ over voltage/
short circuit short circuit
5 years limited warranty 5 years limited warranty
F605 160 x 98 x 39(mm) F610 199 x 98 x 39(mm)

AC input voltage range ................... 85~264VAC (120~370VDC) AC input voltage range ................... 85~132/ 170~264VAC selected by switch
Input frequency .............................. 47~63Hz Input frequency .............................. 47~63Hz
Inrush current .................................. cold start, 20A/115V, 40A/230V Inrush current .................................. cold start, 20A/115V, 40A/230V
Input leakage current ...................... 1mA/ 230VAC Input leakage current ...................... 1mA/ 230VAC
Line regulation (full load) ................. 0.5% Line regulation (full load) ................. 0.5%
Output voltage adjust range ........... V1: 5% of rated output voltage Output voltage adjust range ........... V1: 5% of rated output voltage
V2: unadjustable V2: unadjustable
Output overload protection ............. 105~150%, hiccup mode, auto recovery Output overload protection ............. 110~130%, shut off, re-power on to recover
Output over voltage protection ....... 115~150%, hiccup mode, auto recovery Output over voltage protection ....... 115~150%, shut off, re-power on to recover
Withstand voltage ........................... I/P -O/P: 3.0KVAC/1min Withstand voltage ........................... I/P -O/P: 3.0KVAC/1min
I/P -F/G: 1.5KVAC/1min I/P -F/G: 1.5KVAC/1min
O/P-F/G: 0.5KVAC/1min O/P-F/G: 0.5KVAC/1min
Rise time ......................................... 50ms@full load (typical) Rise time ......................................... 50ms@full load (typical)
Hold up time .................................... 20ms@full load (typical) Hold up time .................................... 20ms@full load (typical)
Operating temperature ................... -20 ~+50 Operating temperature ................... -20 ~+50
Safety standards ............................ GB4943, UL60950, EN60950 Safety standards ............................ GB4943, UL60950, EN60950
EMC standards ............................... GB9254, EN55022 classB, EN55024 EMC standards ............................... GB9254, EN55022 classB, EN55024
EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11 EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11
Cooling method ............................... convection Cooling method ............................... convection
Packing ........................................... 0.46kg/pcs, 36pcs/CTN Packing ........................................... 0.64kg/pcs, 28pcs/CTN

Model DC Output R&N Efficiency Model DC Output R&N Efficiency


13.8V 4.0A 120mV 77% 13.8V 6.0A 120mV 79%
HF55W-SB-13.8 HF100W-SB-13.8
13.4V 0.23A(Charger) 13.3V 0.5A(Charger)
27.6V 2.0A 150mV 78% 27.6V 3.0A 150mV 78%
HF55W-SB-27.6 HF100W-SB-27.6
26.5V 0.16A(Charger) 27.1V 0.5A(Charger)

55W Dual Output for Battery Charging 155W Battery Charging Power Supply
High reliability, low cost To charge lead acid battery
To charge lead acid battery Auto switch when power off (UPS function)
Auto switch when power off (UPS function) AC mains failure signal
Charging current limited Battery low signal
Battery low protection Charging current limited
Protections: overload/ short circuit Protections: overload/ over voltage/
5 years limited warranty short circuit
F605 160 x 98 x 39(mm) 5 years limited warranty
F615 199 x 98 x 50(mm)

AC input voltage range ................... 170~264VAC (210~370VDC) AC input voltage range ................... 85~132/ 170~264VAC selected by switch
Input frequency .............................. 47~63Hz Input frequency .............................. 47~63Hz
Inrush current .................................. cold start, 40A/230V Inrush current .................................. cold start, 20A/115V, 40A/230V
Input leakage current ...................... 0.7mA/ 230VAC Input leakage current ...................... 1mA/ 230VAC
Line regulation (full load) ................. 0.5% Line regulation (full load) ................. 0.5%
Output voltage adjust range ........... V1: 5% of rated output voltage Output voltage adjust range ........... V1: 5% of rated output voltage
V2: unadjustable V2: unadjustable
Output overload protection ............. 105~150%, hiccup mode, auto recovery Output overload protection ............. 110~130%, shut off, re-power on to recover
Withstand voltage ........................... I/P -O/P: 1.5KVAC/1min Output over voltage protection ....... 115~150%, shut off, re-power on to recover
I/P -F/G: 1.5KVAC/1min Withstand voltage ........................... I/P -O/P: 3.0KVAC/1min
O/P-F/G: 0.5KVAC/1min I/P -F/G: 1.5KVAC/1min
Rise time ......................................... 50ms@full load (typical) O/P-F/G: 0.5KVAC/1min
Hold up time .................................... 20ms@full load (typical) Rise time ......................................... 50ms@full load (typical)
Operating temperature ................... -20 ~+50 Hold up time .................................... 20ms@full load (typical)
Safety standards ............................ design meet GB4943, UL60950, EN60950 Operating temperature ................... -20 ~+50
EMC standards ............................... design meet GB9254, EN55022 classA Safety standards ............................ meet GB4943, UL60950, EN60950
EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11 EMC standards ............................... meet GB9254, EN55022 classB
Cooling method ............................... convection EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11
Packing ........................................... 0.46kg/pcs, 36pcs/CTN Cooling method ............................... convection
Packing ........................................... 0.74kg/pcs, 24pcs/CTN

Model DC Output R&N Efficiency


13.8V 11.5A 120mV 82%
HF155W-SB-13.8
Model DC Output R&N Efficiency 13.3V 0.5A(Charger)
12.8V 4.0A 120mV 71% 27.6V 5.5A 150mV 85%
HF55W-D-Z HF155W-SB-27.6
13.8V 0.2A(Charger) 27.1V 0.5A(Charger)
15W~75W Din Rail
15W Single Output DIN Rail Series 50W Single Output DIN Rail Series
Universal AC input / full range Universal AC input / full range
Installed on DIN rail TS35/ 7.5 or 15 Installed on DIN rail TS35/ 7.5 or 15
High reliability, compact design High reliability, compact design
DC OK signal output DC OK signal output
Protections: overload/ over voltage/ Approvals: CE
short circuit Protections: overload/ over voltage/
5 years limited warranty short circuit
F6015DR 35 x 73.5 x 63.4(mm) 5 years limited warranty
F605DR 45 x 89.2 x 75.2(mm)

AC input voltage range ................... 85~264VAC (120~370VDC) AC input voltage range ................... 85~264VAC (120~370VDC)
Input frequency .............................. 47~63Hz Input frequency .............................. 47~63Hz
Inrush current .................................. cold start, 20A/115V, 40A/230V Inrush current .................................. cold start, 20A/115V, 40A/230V
Input leakage current ...................... 1mA/ 230VAC Input leakage current ...................... 1mA/ 230VAC
Line regulation (full load) ................. 0.5% Line regulation (full load) ................. 0.5%
Output voltage adjust range ........... 10% Output voltage adjust range ........... 10%
Output overload protection ............. 105~150%, hiccup mode, auto recovery Output overload protection ............. 105~150%, hiccup mode, auto recovery
Output over voltage protection ....... clamping by zenor diode Output over voltage protection ....... 115~150%, shut off, re-power on to recover
Withstand voltage ........................... I/P -O/P: 3.0KVAC/1min Withstand voltage ........................... I/P -O/P: 3.0KVAC/1min
I/P -F/G: 1.5KVAC/1min I/P -F/G: 1.5KVAC/1min
O/P-F/G: 0.5KVAC/1min O/P-F/G: 0.5KVAC/1min
Rise time ......................................... 50ms@full load (typical) Rise time ......................................... 50ms@full load (typical)
Hold up time .................................... 20ms@full load (typical) Hold up time .................................... 20ms@full load (typical)
Operating temperature ................... -20 ~+50 Operating temperature ................... -20 ~+50
Safety standards ............................ meet UL508, UL60950, EN60950 Safety standards ............................ meet UL508, UL60950/ EN60950 approved
EMC standards ............................... meet EN55022 classB, EN55024 EMC standards ............................... GB9254, EN55022 classB, EN55024
EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11 EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11
Cooling method ............................... convection Cooling method ............................... convection
Connection ...................................... 3P/ 7.5mm pitch, plug-in terminal block Connection ...................................... 3P/ 7.5mm pitch
3P/ 5.0mm pitch, clip terminal block 5P/ 5.0mm pitch, plug-in terminal block
Weight ............................................ 0.17kg/pcs Weight ............................................ 0.31kg/pcs
Model DC Output Load regul. R&N Efficiency Model DC Output Load regul. R&N Efficiency
HF15W-SDR-12 12V 1.25A 0.5% 120mV 82% HF50W-SDR-12 12V 4.2A 0.5% 120mV 80%
HF15W-SDR-15 15V 1.0A 0.5% 120mV 82% HF50W-SDR-13.8 13.8V 3.6A 0.5% 120mV 80%
HF15W-SDR-24 24V 0.63A 0.5% 150mV 82% HF50W-SDR-24 24V 2.1A 0.5% 150mV 80%
HF15W-SDR-48 48V 0.3A 0.5% 150mV 83% HF50W-SDR-48 48V 1.0A 0.5% 150mV 86%

30W Single Output DIN Rail Series 75W Single Output DIN Rail Series
Universal AC input / full range Universal AC input / full range
Installed on DIN rail TS35/ 7.5 or 15 Installed on DIN rail TS35/ 7.5 or 15
High reliability, compact design High reliability, compact design
DC OK signal output 100% full load burn-in test
Protections: overload/ over voltage/ Approvals: CE
short circuit Protections: overload/ over voltage/
5 years limited warranty short circuit
F603DR 35 x 89.2 x 75.2(mm) 5 years limited warranty
F6075DR 45 x 101.2 x 90.2(mm)

AC input voltage range ................... 85~264VAC (120~370VDC) AC input voltage range ................... 85~264VAC (120~370VDC)
Input frequency .............................. 47~63Hz Input frequency .............................. 47~63Hz
Inrush current .................................. cold start, 20A/115V, 40A/230V Inrush current .................................. cold start, 20A/115V, 40A/230V
Input leakage current ...................... 1mA/ 230VAC Input leakage current ...................... 1mA/ 230VAC
Line regulation (full load) ................. 0.5% Line regulation (full load) ................. 0.5%
Output voltage adjust range ........... 10% Output voltage adjust range ........... 10%
Output overload protection ............. 105~150%, hiccup mode, auto recovery Output overload protection ............. 105~150%, hiccup mode, auto recovery
Output over voltage protection ....... 115~150%, shut off, re-power on to recover Output over voltage protection ....... 115~150%, shut off, re-power on to recover
Withstand voltage ........................... I/P -O/P: 3.0KVAC/1min Withstand voltage ........................... I/P -O/P: 3.0KVAC/1min
I/P -F/G: 1.5KVAC/1min I/P -F/G: 1.5KVAC/1min
O/P-F/G: 0.5KVAC/1min O/P-F/G: 0.5KVAC/1min
Rise time ......................................... 50ms@full load (typical) Rise time ......................................... 50ms@full load (typical)
Hold up time .................................... 20ms@full load (typical) Hold up time .................................... 20ms@full load (typical)
Operating temperature ................... -20 ~+50 Operating temperature ................... -20 ~+50
Safety standards ............................ meet UL508, UL60950, EN60950 Safety standards ............................ meet UL508, UL60950, EN60950
EMC standards ............................... meet EN55022 classB, EN55024 EMC standards ............................... meet EN55022 classB, EN55024
EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11 EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11
Cooling method ............................... convection Cooling method ............................... convection
Connection ...................................... 3P/ 7.5mm pitch Connection ...................................... 3P/ 7.5mm pitch
3P/ 5.0mm pitch, plug-in terminal block 4P/ 5.0mm pitch, plug-in terminal block
Weight ............................................ 0.25kg/pcs Weight ............................................ 0.42kg/pcs
Model DC Output Load regul. R&N Efficiency
HF30W-SDR-12 12V 2.5A 0.5% 120mV 81% Model DC Output Load regul. R&N Efficiency
HF30W-SDR-15 15V 2.0A 0.5% 120mV 82% HF75W-SDR-12 12V 6.3A 0.5% 120mV 83%
HF30W-SDR-24 24V 1.5A 0.5% 150mV 83% HF75W-SDR-24 24V 3.2A 0.5% 150mV 86%
HF30W-SDR-48 48V 0.63A 0.5% 150mV 86% HF75W-SDR-48 48V 1.6A 0.5% 150mV 87%
120W~240W Din Rail
120W Single Output DIN Rail Series 150W Single Output DIN Rail Series
AC input range selected by switch AC input range selected by jumper
High reliability, low cost Installed on DIN rail TS35/ 7.5 or 15
Installed on DIN rail TS35/ 7.5 or 15 UL508 listed, UL/ CUL/ CE
Approvals: CE High reliability, compact design
Protections: overload/ over voltage/ Protections: overload/ over voltage/
short circuit short circuit
5 years limited warranty 5 years limited warranty
F612DRF 45.4 x 99.5 x 114(mm) F615DR 108.4 x 74.2 x 109(mm)

AC input voltage range ................... 85~132/ 170~264VAC selected by switch AC input voltage range ................... 85~132/ 170~264VAC selected by jumper
Input frequency .............................. 47~63Hz Input frequency .............................. 47~63Hz
Inrush current .................................. cold start, 20A/115V, 40A/230V Inrush current .................................. cold start, 40A/230V
Input leakage current ...................... 1mA/ 230VAC Input leakage current ...................... 1mA/ 230VAC
Line regulation (full load) ................. 0.5% Line regulation (full load) ................. 0.5%
Output voltage adjust range ........... 10% Output voltage adjust range ........... 10%
Output overload protection ............. 105~150%, hiccup mode, auto recovery Output overload protection ............. 110~130%, delay shutdown, re-power on to
Output over voltage protection ....... 115~150%, shut off, re-power on to recover recover
Withstand voltage ........................... I/P -O/P: 3.0KVAC/1min Output over voltage protection ....... 115~150%, shut off, re-power on to recover
I/P -F/G: 1.5KVAC/1min Withstand voltage ........................... I/P-O/P:3.0KVAC/1min;I/P-F/G:1.5KVAC/1min
O/P-F/G: 0.5KVAC/1min O/P-F/G:0.5KVAC/1min
Rise time ......................................... 50ms@full load (typical) Rise, Hold up time .......................... 50ms, 20ms@full load (typical)
Hold up time .................................... 20ms@full load (typical) Operating temperature ................... -20 ~+50
Operating temperature ................... -20 ~+50 Safety standards ............................ UL508, UL60950, EN60950 approved
Safety standards ............................ meet UL508, UL60950, EN60950 EMC standards ............................... meet EN55022 classB, EN61000-3-2,3,
EMC standards ............................... meet EN55022 classB, EN55024 EN61000-4-2,3,4,5,6,8,11
EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11 Cooling method ............................... convection
Cooling method ............................... convection Connection ...................................... 3P/ 6.35mm pitch
Connection ...................................... 3P/ 7.5mm pitch 4P/ 6.35mm pitch, screw terminal block
4P/ 5.0mm pitch, plug-in terminal block Weight ............................................ 0.64kg/pcs
Weight ............................................ 0.54kg/pcs
Model DC Output Load regul. R&N Efficiency
HF150W-SDR-12 12V 12.5A 0.5% 120mV 85%
Model DC Output Load regul. R&N Efficiency HF150W-SDR-13.8 13.8V 11.0A 0.5% 120mV 85%
HF120W-SFDR-12 12V 10.0A 0.5% 120mV 83% HF150W-SDR-15 15V 10.0A 0.5% 120mV 85%
HF120W-SFDR-24 24V 5.0A 0.5% 150mV 86% HF150W-SDR-24 24V 6.3A 0.5% 150mV 86%
HF120W-SFDR-48 48V 2.5A 0.5% 150mV 87% HF150W-SDR-48 48V 3.1A 0.5% 150mV 86%

120W Single Output DIN Rail - with PFC 240W Single Output DIN Rail - with PFC
Universal AC input / full range Universal AC input / full range
PF>0.98@115VAC; >0.94@230VAC PF>0.98@115VAC; >0.94@230VAC
Installed on DIN rail TS35/ 7.5 or 15 Installed on DIN rail TS35/ 7.5 or 15
OCP indication High efficiency up to 90%
High reliability, compact design ZCS technology to reduce power
Protections: overload/ over voltage/ dissipation
over temperature/ short circuit Protections: overload/ over voltage/
5 years limited warranty over temperature/ short circuit
F612DRL 50 x 107.1 x 120.2(mm) 5 years limited warranty
F624DR 63.2 x 114.4 x 125.2(mm)
AC input voltage range ................... 85~264VAC (120~370VDC) AC input voltage range ................... 85~264VAC (120~370VDC)
Input frequency .............................. 47~63Hz Input frequency .............................. 47~63Hz
Inrush current .................................. cold start, 20A/115V, 40A/230V Inrush current .................................. cold start, 20A/115V, 40A/230V
Input leakage current ...................... 1mA/ 230VAC Input leakage current ...................... 1mA/ 230VAC
Line regulation (full load) ................. 0.5% Line regulation (full load) ................. 0.5%
Output voltage adjust range ........... 10% Output voltage adjust range ........... 10%
Output overload protection ............. 110~130%, delay shutdown, re-power on to Output overload protection ............. 110~130%, delay shutdown, re-power on to
recover recover
Output over voltage protection ....... 115~150%, shut off, re-power on to recover Output over voltage protection ....... 115~150%, shut off, re-power on to recover
Withstand voltage ........................... I/P -O/P: 3.0KVAC/1min Withstand voltage ........................... I/P -O/P: 3.0KVAC/1min
I/P -F/G: 1.5KVAC/1min I/P -F/G: 1.5KVAC/1min
O/P-F/G: 0.5KVAC/1min O/P-F/G: 0.5KVAC/1min
Rise time ......................................... 50ms@full load (typical) Rise time ......................................... 50ms@full load (typical)
Hold up time .................................... 20ms@full load (typical) Hold up time .................................... 20ms@full load (typical)
Operating temperature ................... -20 ~+50 Operating temperature ................... -20 ~+50
Safety standards ............................ meet UL508, UL60950, EN60950 Safety standards ............................ meet UL508, UL60950, EN60950
EMC standards ............................... meet EN55022 classB, EN55024 EMC standards ............................... meet EN55022 classB, EN55024,
EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11 EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11
Cooling method ............................... convection Cooling method ............................... convection
Connection ...................................... 3P/ 7.5mm pitch Connection ...................................... 3P/ 7.5mm pitch
4P/ 5.0mm pitch, plug-in terminal block 6P/ 5.0mm pitch, plug-in terminal block
Weight ............................................ 0.64kg/pcs Weight ............................................ 0.90kg/pcs

Model DC Output Load regul. R&N Efficiency


HF120W-SDR-12 12V 10.0A 0.5% 120mV 84% Model DC Output Load regul. R&N Efficiency
HF120W-SDR-24 24V 5.0A 0.5% 150mV 85% HF240W-SDR-24 24V 10.0A 0.5% 150mV 91%
HF120W-SDR-48 48V 2.5A 0.5% 150mV 87% HF240W-SDR-48 48V 5.0A 0.5% 150mV 92%
20W~60W LED Series
20W LED Driver - Constant Current 60W LED Driver - Constant Current
Universal AC input / full range Universal AC input / full range
Plastic cover, IP67 design Plastic cover, IP67 design
Constant current design Constant current design
Isolation class 2, no PE Isolation class 2, no PE
High reliability, low cost High reliability, low cost
Protections: over voltage/ short circuit Protections: over voltage/ short circuit
2 years warranty 2 years warranty
118 x 35 x 26(mm) 162.5 x 42.5 x 32(mm)

AC input voltage range ................... 90~264VAC (127~370VDC) AC input voltage range ................... 90~264VAC (127~370VDC)
Input frequency .............................. 47~63Hz Input frequency .............................. 47~63Hz
Inrush current .................................. cold start, 35A/115V, 70A/230V Inrush current .................................. cold start, 30A/115V, 60A/230V
Input leakage current ...................... 0.25mA/ 230VAC Input leakage current ...................... 0.25mA/ 230VAC
Line regulation (full load) ................. 0.5% Line regulation (full load) ................. 0.5%
Output overload protection ............. 5% current limiting, auto recovery Output overload protection ............. 5% current limiting, auto recovery
Output over voltage protection ....... 115~150%, shut off, re-power on to recover Output over voltage protection ....... 115~150%, shut off, re-power on to recover
Short circuit protection .................... hiccup mode, auto recovery Short circuit protection .................... hiccup mode, auto recovery
Withstand voltage ........................... I/P -O/P: 3.75KVAC/1min Withstand voltage ........................... I/P -O/P: 3.75KVAC/1min
Rise time ......................................... 50ms@full load (typical) Rise time ......................................... 50ms@full load (typical)
Hold up time .................................... 20ms@full load (typical) Hold up time .................................... 20ms@full load (typical)
Operating temperature ................... -30 ~+50 Operating temperature ................... -30 ~+50
Safety standards ............................ design refer to UL1310 Class 2, UL8750 Safety standards ............................ design refer to UL1310 Class 2, UL8750
EN60950 EN60950
EMC standards ............................... design refer to EN55022 Class B EMC standards ............................... design refer to EN55022 Class B
EN61000-3-2 Class A, EN61000-3-3 EN61000-3-2 Class A, EN61000-3-3
EN61000-4-2,3,4,5,6,8,11, EN61547 EN61000-4-2,3,4,5,6,8,11, EN61547
Cooling method ............................... convection Cooling method ............................... convection
Weight ............................................ 0.20kg/pcs Weight ............................................ 0.41kg/pcs

Model DC Output Current Tol. R&N Efficiency


Model DC Output Current Tol. R&N Efficiency HF60W-PLD-1050 9~48V 1050mA 5% 200mV 83%
HF20W-PLD-350 9~48V 350mA 5% 200mV 86% HF60W-PLD-1400 9~42V 1400mA 5% 200mV 88%
HF20W-PLD-700 9~30V 700mA 5% 200mV 84% HF60W-PLD-1750 9~34V 1750mA 5% 200mV 86%

35W LED Driver - Constant Current 20W LED Power Supply - Constant Voltage
Universal AC input / full range Universal AC input / full range
Plastic cover, IP67 design Plastic cover, IP67 design
Constant current design Constant voltage design
Isolation class 2, no PE Isolation class 2, no PE
High reliability, low cost High reliability, low cost
Protections: over voltage/ short circuit Protections: overload/ over voltage/
2 years warranty short circuit
148 x 40 x 30(mm) 2 years warranty
118 x 35 x 26(mm)

AC input voltage range ................... 90~264VAC (127~370VDC) AC input voltage range ................... 90~264VAC (127~370VDC)
Input frequency .............................. 47~63Hz Input frequency .............................. 47~63Hz
Inrush current .................................. cold start, 30A/115V, 60A/230V Inrush current .................................. cold start, 35A/115V, 70A/230V
Input leakage current ...................... 0.25mA/ 230VAC Input leakage current ...................... 0.25mA/ 230VAC
Line regulation (full load) ................. 0.5% Line regulation (full load) ................. 0.5%
Output overload protection ............. 5% current limiting, auto recovery Load regulation ................................ 0.5%
Output over voltage protection ....... 115~150%, shut off, re-power on to recover Output overload protection ............. 105~150%, hiccup mode, auto recovery
Short circuit protection .................... hiccup mode, auto recovery Output over voltage protection ....... clamping by zenor diode
Withstand voltage ........................... I/P -O/P: 3.75KVAC/1min Short circuit protection .................... hiccup mode, auto recovery
Rise time ......................................... 50ms@full load (typical) Withstand voltage ........................... I/P -O/P: 3.75KVAC/1min
Hold up time .................................... 20ms@full load (typical) Rise time ......................................... 250ms@full load (typical)
Operating temperature ................... -30 ~+50 Hold up time .................................... 50ms@full load (typical)
Safety standards ............................ design refer to UL1310 Class 2, UL8750 Operating temperature ................... -30 ~+50
EN60950 Safety standards ............................ design refer to UL1310 Class 2, UL8750
EMC standards ............................... design refer to EN55022 Class B EN60950
EN61000-3-2 Class A, EN61000-3-3 EMC standards ............................... design refer to EN55022 Class B
EN61000-4-2,3,4,5,6,8,11, EN61547 EN61000-3-2 Class A, EN61000-3-3
Cooling method ............................... convection EN61000-4-2,3,4,5,6,8,11, EN61547
Weight ............................................ 0.31kg/pcs Cooling method ............................... convection
Weight ............................................ 0.20kg/pcs
Model DC Output Voltage Tol. R&N Efficiency
Model DC Output Current Tol. R&N Efficiency HF20W-PLV-12 12V 1.70A 3% 120mV 80%
HF35W-PLD-700 9~48V 700mA 5% 200mV 88% HF20W-PLV-15 15V 1.33A 3% 120mV 81%
HF35W-PLD-1050 9~30V 1050mA 5% 200mV 86% HF20W-PLV-24 24V 0.84A 3% 150mV 82%
HF35W-PLD-1400 9~24V 1400mA 5% 200mV 85% HF20W-PLV-48 48V 0.42A 3% 150mV 84%
20W~55W LED Series
35W LED Power Supply - Constant Voltage 40W LED Driver - with PFC
Universal AC input / full range Universal AC input / full range
Plastic cover, IP67 design Plastic cover, IP67 design
Constant voltage design Built-in constant current limiting circuit
Isolation class 2, no PE Built-in active PFC, PF>0.9@230VAC
High reliability, low cost Suitable for outdoor LED lighting
Protections: overload/ over voltage/ applications, dry/ damp/ wet locations
short circuit Protections: over current/ over voltage/
2 years warranty short circuit
148 x 40 x 30(mm) 2 years warranty
162.5 x 42.5 x 32(mm)
AC input voltage range ................... 90~264VAC (127~370VDC) AC input voltage range ................... 90~264VAC (127~370VDC)
Input frequency .............................. 47~63Hz Input frequency .............................. 47~63Hz
Inrush current .................................. cold start, 35A/115V, 70A/230V Inrush current ..................................
cold start, 40A/230V
Input leakage current ...................... 0.25mA/ 230VAC Input leakage current ...................... 0.25mA/ 230VAC
Line regulation (full load) ................. 0.5% Line regulation (full load) ................. 0.5%
Load regulation ................................ 0.5% Load regulation ................................ 0.5%
Output overload protection ............. 105~150%, hiccup mode, auto recovery Output over current protection ........ 100~110%, current limiting, auto recovery
Output over voltage protection ....... 115~150%, shut off, re-power on to recover Output over voltage protection ....... 115~150%, shut off, re-power on to recover
Short circuit protection .................... hiccup mode, auto recovery Short circuit protection .................... hiccup mode, auto recovery
Withstand voltage ........................... I/P -O/P: 3.75KVAC/1min Withstand voltage ........................... I/P -O/P: 3.75KVAC/1min
Rise time ......................................... 250ms@full load (typical) Rise time .........................................
80ms@full load (typical)
Hold up time .................................... 50ms@full load (typical) Hold up time ....................................
20ms@full load (typical)
Operating temperature ................... -30 ~+50 Operating temperature ................... -30 ~+50
Safety standards ............................ design refer to UL1310 Class 2, UL8750 Safety standards ............................ design meet UL1310 Class 2, UL8750
EN60950 EN61347, EN60950
EMC standards ............................... design refer to EN55022 Class B EMC standards ............................... design meet EN55015, EN55022 Class B
EN61000-3-2 Class A, EN61000-3-3 EN61000-3-2 Class C, EN61000-3-3
EN61000-4-2,3,4,5,6,8,11, EN61547 EN61000-4-2,3,4,5,6,8,11, EN61547
Cooling method ............................... convection Cooling method ............................... convection
Weight ............................................ 0.31kg/pcs

Model DC Output Voltage Tol. R&N Efficiency


Constant
HF35W-PLV-12 12V 3.0A 3% 120mV 80% Model DC Output current range Tolerance R&N Efficiency
HF35W-PLV-15 15V 2.4A 3% 120mV 80% HF40W-PLC-12 12V 3.34A 9~12V 4% 2.0V 82.0%
HF35W-PLV-24 24V 1.5A 3% 150mV 81% HF40W-PLC-24 24V 1.67A 18~24V 4% 2.7V 84.0%
HF35W-PLV-36 36V 1.0A 3% 150mV 82% HF40W-PLC-36 36V 1.12A 27~36V 4% 3.6V 85.0%
HF35W-PLV-48 48V 0.75A 3% 150mV 83% HF40W-PLC-48 48V 0.84A 36~48V 4% 4.6V 85.5%

20W LED Driver - with PFC 55W LED Driver - with PFC
Universal AC input / full range High reliability
Plastic cover, IP67 design Compact design, plastic cover, IP20
Built-in constant current limiting circuit Constant current limiting design
Built-in active PFC, PF>0.9@230VAC Built-in active PFC, PF>0.9@230VAC
Suitable for outdoor LED lighting Suitable for indoor LED lighting applications
applications, dry/ damp/ wet locations Protections: short circuit
Protections: over current/ over voltage/ 2 years warranty
short circuit 163 x 45.5 x 31.5(mm)
2 years warranty
148 x 40 x 30(mm)

AC input voltage range ................... 90~264VAC (127~370VDC) AC input voltage range ................... 176~265VAC (220~370VDC)
Input frequency .............................. 47~63Hz Input frequency .............................. 47~63Hz
Inrush current .................................. cold start, 40A/230V Inrush current .................................. cold start, 20A/230V
Input leakage current ...................... 0.25mA/ 230VAC Input leakage current ...................... 0.25mA/ 230VAC
Line regulation (full load) ................. 0.5% Line regulation (full load) ................. 0.5%
Load regulation ................................ 0.5% Load regulation ............................... 0.5%
Output over current protection ........ 100~110%, current limiting, auto recovery Constant current tolerance ............. 5%
Output over voltage protection ....... 115~150%, shut off, re-power on to recover Short circuit protection .................... hiccup mode, auto recovery
Short circuit protection .................... hiccup mode, auto recovery Withstand voltage ........................... I/P -O/P: 3.75KVAC/1min
Withstand voltage ........................... I/P -O/P: 3.75KVAC/1min I/P -F/G: 1.88KVAC/1min
Rise time ......................................... 80ms@full load (typical) O/P-F/G: 0.5KVAC/1min
Hold up time .................................... 20ms@full load (typical) Rise time ......................................... 50ms@full load (typical)
Operating temperature ................... -30 ~+50 Hold up time .................................... 20ms@full load (typical)
Safety standards ............................ design meet UL1310 Class 2, UL8750 Operating temperature ................... -30 ~+50
EN61347, EN60950 Safety standards ............................ design meet UL1310 Class 2, UL8750
EMC standards ............................... design meet EN55015, EN55022 Class B EN61347, EN60950
EN61000-3-2 Class D, EN61000-3-3 EMC standards ............................... design meet EN55015, EN55022 Class B
EN61000-4-2,3,4,5,6,8,11, EN61547 EN61000-3-2 Class C, EN61000-3-3
Cooling method ............................... convection EN61000-4-2,3,4,5,6,8,11, EN61547
Cooling method ............................... convection
Constant
Model DC Output current range Tolerance R&N Efficiency
HF20W-PLC-12 12V 1.70A 8.4~12V 4% 2.0V 81.0% Model DC Output No-load Voltage R&N Efficiency
HF20W-PLC-24 24V 0.84A 16.8~24V 4% 2.4V 83.0% HF55W-PLC-1500 18~35V 1.5A max. 37V 3.6V 85%
HF20W-PLC-36 36V 0.56A 25.2~30V 4% 3.6V 84.0% HF55W-PLC-2300 12~24V 2.3A max. 28V 2.4V 83%
HF20W-PLC-48 48V 0.42A 33.6~48V 4% 3.7V 84.5% HF55W-PLC-1100 24~48V 1.1A max. 55V 3.7V 85%
9W~150W Dimming / 60W LED Series
9~18W Dimming LED Driver - with PFC 150W Dimming LED Driver - with PFC
Dimmable with ordinary TRIAC dimmer Universal AC input (up to 295VAC)
Constant current design Built-in constant current limiting circuit
Compact design, plastic cover, IP21 Output current adjustable through cable
Isolation class 2, no PE IP67 design, suitable for outdoor or damp
Suitable for indoor LED lighting applications locations
Built-in active PFC, PF>0.9@230VAC PF>0.98@115VAC; PF>0.95@230VAC
Protections: short circuit Protections: overload/ over voltage/
2 years warranty over temperature/ short circuit
113.5 x 45 x 28.5(mm) 2 years warranty
222.2 x 68 x 38.8(mm)
AC input voltage range ................... 190~264VAC AC input voltage range ................... 90~295VAC (127~370VDC)
Input frequency .............................. 47~63Hz Input frequency .............................. 47~63Hz
Inrush current .................................. cold start, 40A/230V Inrush current .................................. cold start, 65A/230V
Input leakage current ...................... 0.25mA/ 230VAC Input leakage current ...................... 1mA/ 230VAC
Line regulation (full load) ................. 0.5% Line regulation (full load) ................. 0.5%
Constant current tolerance ............. 5% Load regulation ............................... 1% (12V,15V); 0.5% (24V,48V)
Dimming range ................................ 1~100% Output overload protection ............. 95~108%, current limiting, auto recovery
Short circuit protection .................... hiccup mode, auto recovery Output over voltage protection ....... 115~150%, shut off, re-power on to recover
Withstand voltage ........................... I/P -O/P: 3.75KVAC/1min Short circuit protection .................... hiccup mode, auto recovery
Set up time ...................................... 800ms@full load (typical) Withstand voltage ........................... I/P -O/P: 3.75KVAC/1min
Rise time ......................................... 50ms@full load (typical) I/P -F/G: 1.88KVAC/1min
Hold up time .................................... 20ms@full load (typical) O/P-F/G: 0.5KVAC/1min
Operating temperature ................... -30 ~+50 Rise time, hold up time ................... 80ms, 50ms@full load (typical)
Safety standards ............................ design meet UL1310 Class 2, UL8750 Operating temperature ................... -30 ~+50
EN61347, EN60950 Safety standards ............................ design meet UL8750, UL60950
EMC standards ............................... design meet EN55015, EN55022 Class B EN61347, EN60950
EN61000-3-2 Class D, EN61000-3-3 EMC standards ............................... design meet EN55015, EN55022 Class B
EN61000-4-2,3,4,5,6,8,11, EN61547 EN61000-3-2 Class C, EN61000-3-3
Cooling method ............................... convection EN61000-4-2,3,4,5,6,8,11, EN61547
Weight ............................................ 0.10kg/pcs Cooling method ............................... convection

Model DC Output Load regul. R&N Efficiency


HF9W-PLA-350 6~26V 350mA 0.5% 2.6V 78.0% Model DC Output Tolerance R&N Efficiency
HF18W-PLA-350 15~52V 350mA 0.5% 3.7V 82.0% HF150W-CLA-12 12V 11.0A 2% 150mV 82%
HF18W-PLA-500 9~36V 500mA 0.5% 3.6V 81.0% HF150W-CLA-15 15V 9.5A 2% 150mV 84%
HF18W-PLA-700 6~26V 700mA 0.5% 2.6V 80.5% HF150W-CLA-24 24V 6.3A 1% 150mV 85%
HF18W-PLA-1050 3~18V 1.05A 0.5% 2.2V 80.0% HF150W-CLA-48 48V 3.2A 1% 200mV 86%

30~36W Dimming LED Driver - with PFC 60W LED Power Supply
Dimmable with ordinary TRIAC dimmer Universal AC input / full range
Constant current design IP67 design (IP66 optional)
Compact design, plastic cover, IP20 Suitable for outdoor or damp locations
Isolation class 2, no PE PF>0.92@230VAC (HF60W-SLD only)
Suitable for indoor LED lighting applications Protections: overload/ over voltage/
Built-in active PFC, PF>0.9@230VAC short circuit
Protections: short circuit 2 years warranty
2 years warranty F606SLD 175 x 63 x 42(mm)
163 x 45.5 x 31.5(mm)
AC input voltage range ................... 90~264VAC (127~370VDC)
Inrush current .................................. cold start, 30A/115V,60A/230V
AC input voltage range ................... 190~264VAC Input leakage current ...................... 1mA/ 230VAC
Input frequency .............................. 47~63Hz HF60W-SLD:
Inrush current ..................................
cold start, 40A/230V Output overload protection ............. 110~130%, hiccup mode, auto recovery
Input leakage current ...................... 0.25mA/ 230VAC Output over voltage protection ....... 115~150%, hiccup mode, auto recovery
Line regulation (full load) ................. 0.5% HF60W-ELD:
Constant current tolerance ............. 5% Output overload protection ............. 105~150%, hiccup mode, auto recovery
Dimming range ................................ 1~100% Output over voltage protection ....... 115~150%, shut off, re-power on to recover
Short circuit protection .................... hiccup mode, auto recovery Short circuit protection .................... hiccup mode, auto recovery
Withstand voltage ........................... I/P -O/P: 3.75KVAC/1min Withstand voltage ........................... I/P-O/P:3.0KVAC/1min;I/P-F/G:1.5KVAC/1min
Set up time ......................................
800ms@full load (typical) O/P-F/G:0.5KVAC/1min
Rise time .........................................
50ms@full load (typical) Rise time, Hold up time .................. 50ms, 20ms@full load (typical)
Hold up time ....................................
20ms@full load (typical) Operating temperature ................... -30 ~+50
Operating temperature ................... -30 ~+50 Safety standards ............................ UL8750 approved
Safety standards ............................ design meet UL1310 Class 2, UL8750 EMC standards ............................... design refer to EN55022 Class B
EN61347, EN60950 EN61000-3-2 Class A, EN61000-3-3
EMC standards ............................... design meet EN55015, EN55022 Class B EN61000-4-2,3,4,5,6,8,11, EN61547
EN61000-3-2 Class C, EN61000-3-3 Cooling method ............................... convection
EN61000-4-2,3,4,5,6,8,11, EN61547 Weight ............................................ 0.85kg (SLD, IP67), 0.55kg (ELD, IP66)
Cooling method ............................... convection
Model (with PFC) DC Output Load regul. R&N Efficiency
HF60W-SLD-12 12V 5.0A 2.0% 300mV 81%
HF60W-SLD-24 24V 2.5A 2.0% 300mV 83%
Model DC Output Load regul. R&N Efficiency
HF30W-PLA-500 30~56V 500mA 0.5% 3.7V 85% Model (without PFC) DC Output Load regul. R&N Efficiency
HF36W-PLA-700 24~52V 700mA 0.5% 3.7V 86% HF60W-ELD-12 12V 5.0A 2.0% 200mV 82%
HF36W-PLA-1050 16~35V 1.05A 0.5% 3.5V 84% HF60W-ELD-24 24V 2.5A 2.0% 200mV 83%
100W~150W LED / 60W Rain-proof Series
100W LED Power Supply - with PFC 150W Single Output Waterproof Series
Universal AC input (up to 295VAC) High reliability
IP66 design (IP67 optional) IP67 design, fully capsuled
Suitable for outdoor or damp locations Suitable for wet or damp locations
PF>0.98@115VAC; PF>0.94@230VAC Designed for outdoor or indoor applications
Protections: overload/ over voltage/ Protections: overload/ over voltage/
over temperature/ short circuit short circuit
2 years warranty 2 years warranty
194 x 63 x 42(mm) F615SLD 196 x 95 x 48(mm)

AC input voltage range ................... 90~295VAC (127~370VDC) AC input voltage range ................... 170~264VAC (210~370VDC)
Input frequency .............................. 47~63Hz Input frequency .............................. 47~63Hz
Inrush current .................................. cold start, 30A/115V, 60A/230V Inrush current .................................. cold start, 40A/230V
Input leakage current ...................... 1mA/ 230VAC Input leakage current ...................... 0.7mA/ 230VAC
Line regulation (full load) ................. 0.5% Line regulation (full load) ................. 0.5%
Output voltage adjust range ........... 10% Output voltage adjust range ........... 10%
Output overload protection ............. 95~108%, current limiting, auto recovery Output overload protection ............. 110~130%, current limiting
Output over voltage protection ....... 115~150%, shut off, re-power on to recover Output over voltage protection ....... 115~150%, shut off, re-power on to recover
Short circuit protection .................... hiccup mode, auto recovery Output over temp. protection ......... power derated automatically
Withstand voltage ........................... I/P -O/P: 3.75KVAC/1min when over temperature
I/P -F/G: 1.88KVAC/1min Short circuit protection .................... no auto recovery
O/P-F/G: 0.5KVAC/1min Withstand voltage ........................... I/P -O/P: 1.5KVAC/1min
Rise time ......................................... 50ms@full load (typical) I/P -F/G: 1.5KVAC/1min
Hold up time .................................... 20ms@full load (typical) O/P-F/G: 0.5KVAC/1min
Operating temperature ................... -30 ~+50 Rise, Hold up time .......................... 50ms, 20ms@full load (typical)
Safety standards ............................ design meet UL8750, UL60950 Operating temperature ................... -20 ~+50
EN61347, EN60950 Safety standards ............................ design refer to GB4943, UL60950, EN60950
EMC standards ............................... design meet EN55015, EN55022 Class B EMC standards ............................... design refer to GB9254, EN55022 classA
EN61000-3-2 Class C, EN61000-3-3 Cooling method ............................... convection
EN61000-4-2,3,4,5,6,8,11, EN61547 Packing ........................................... 1.46kg/pcs, 14pcs/CTN
Cooling method ............................... convection
Model DC Output Load regul. R&N Efficiency
HF150W-SI-12 12V 12.5A 0.5% 120mV 83%
Model DC Output Load regul. R&N Efficiency HF150W-SI-15 15V 10.0A 0.5% 120mV 83%
HF100W-CLD-20 20V 4.8A 2.0% 2.0V 86% HF150W-SI-24 24V 6.3A 0.5% 150mV 84%
HF100W-CLD-24 24V 4.0A 2.0% 2.7V 87% HF150W-SI-27 27V 5.6A 0.5% 150mV 84%
HF100W-CLD-48 48V 2.0A 2.0% 4.6V 88% HF150W-SI-36 36V 4.2A 0.5% 150mV 85%
HF100W-CLD-54 54V 1.77A 2.0% 5.0V 88% HF150W-SI-48 48V 3.1A 0.5% 150mV 86%

150W LED Power Supply - with PFC 60W Rain-proof Series


Universal AC input (up to 295VAC) High reliability, low cost
IP67 design, fully capsuled Suitable for outdoor or damp locations
Suitable for outdoor or damp locations IP21 design
PF>0.98@115VAC; PF>0.94@230VAC Built-in EMI filter
Protections: overload/ over voltage/ 100% full load burn-in test
over temperature/ short circuit Protections: overload/ short circuit
2 years warranty 2 years warranty
201 x 63 x 42(mm) 156.3 x 103.6 x 52(mm)

AC input voltage range ................... 90~295VAC (127~370VDC)


Input frequency .............................. 47~63Hz
Inrush current .................................. cold start, 30A/115V, 60A/230V AC input voltage range ................... 170~264VAC (210~370VDC)
Input leakage current ...................... 1mA/ 230VAC Input current .................................... max. 1.0A
Line regulation (full load) ................. 0.5% Input frequency .............................. 47~63Hz
Output voltage adjust range ........... 10% Inrush current .................................. cold start, 40A/230V
Output overload protection ............. 95~108%, current limiting, auto recovery Input leakage current ...................... 0.7mA/ 230VAC
Output over voltage protection ....... 115~150%, shut off, re-power on to recover Line regulation (full load) ................. 0.5%
Short circuit protection .................... hiccup mode, auto recovery Output voltage adjust range ........... 10%
Withstand voltage ........................... I/P -O/P: 3.75KVAC/1min Output overload protection ............. built-in IC protection, hiccup mode,
I/P -F/G: 1.88KVAC/1min auto recovery
O/P-F/G: 0.5KVAC/1min Short circuit protection .................... hiccup mode, auto recovery
Rise time ......................................... 50ms@full load (typical) Withstand voltage ........................... I/P -O/P: 1.5KVAC/1min
Hold up time .................................... 20ms@full load (typical) I/P -F/G: 1.5KVAC/1min
Operating temperature ................... -30 ~+50 O/P-F/G: 0.5KVAC/1min
Safety standards ............................ design meet UL8750, UL60950 Rise time ......................................... 50ms@full load (typical)
EN61347, EN60950 Hold up time .................................... 20ms@full load (typical)
EMC standards ............................... design meet EN55015, EN55022 Class B Operating temperature ................... -20 ~+50
EN61000-3-2 Class C, EN61000-3-3 Safety standards ............................ design refer to GB4943, UL60950, EN60950
EN61000-4-2,3,4,5,6,8,11, EN61547 EMC standards ............................... design refer to GB9254, EN55022 classA
Cooling method ............................... convection Cooling method ............................... convection

Model DC Output Load regul. R&N Efficiency


HF150W-CLD-12 12V 11.0A 2.0% 150mV 84% Model DC Output Load regul. R&N Efficiency
HF150W-CLD-15 15V 9.5A 2.0% 150mV 85% HF60W-YS-12 12V 5.0A 0.5% 120mV 81%
HF150W-CLD-24 24V 6.3A 2.0% 150mV 86% HF60W-YS-24 24V 2.5A 0.5% 150mV 82%
HF150W-CLD-48 48V 3.2A 2.0% 200mV 87% HF60W-YS-48 48V 1.3A 0.5% 150mV 84%
100W~400W Rain-proof Series
100W Rain-proof Series 350W Rain-proof Series
High reliability, low cost High reliability, low cost
Suitable for outdoor or damp locations Suitable for outdoor or damp locations
IP21 design IP21 design
Built-in EMI filter Built-in EMI filter
100% full load burn-in test 100% full load burn-in test
Protections: overload/ short circuit Protections: overload/ short circuit
2 years warranty 2 years warranty
186.5 x 103.6 x 59(mm) 235 x 137 x 67.5(mm)

AC input voltage range ................... 170~264VAC (210~370VDC) AC input voltage range ................... 170~264VAC (210~370VDC)
Input current .................................... max. 1.5A Input current .................................... max. 4.0A
Input frequency .............................. 47~63Hz Input frequency .............................. 47~63Hz
Inrush current .................................. cold start, 40A/230V Inrush current .................................. cold start, 40A/230V
Input leakage current ...................... 0.7mA/ 230VAC Input leakage current ...................... 0.7mA/ 230VAC
Line regulation (full load) ................. 0.5% Line regulation (full load) ................. 0.5%
Output voltage adjust range ........... 10% Output voltage adjust range ........... 10%
Output overload protection ............. 105~150%, hiccup mode, auto recovery Output overload protection ............. 110~130%, shut off, re-power on to recover
Short circuit protection .................... hiccup mode, auto recovery Short circuit protection .................... shut off, re-power on to recover
Withstand voltage ........................... I/P -O/P: 1.5KVAC/1min Withstand voltage ........................... I/P -O/P: 1.5KVAC/1min
I/P -F/G: 1.5KVAC/1min I/P -F/G: 1.5KVAC/1min
O/P-F/G: 0.5KVAC/1min O/P-F/G: 0.5KVAC/1min
Rise time ......................................... 50ms@full load (typical) Rise time ......................................... 50ms@full load (typical)
Hold up time .................................... 20ms@full load (typical) Hold up time .................................... 20ms@full load (typical)
Operating temperature ................... -20 ~+50 Operating temperature ................... -20 ~+50
Safety standards ............................ design refer to GB4943, UL60950, EN60950 Safety standards ............................ design refer to GB4943, UL60950, EN60950
EMC standards ............................... design refer to GB9254, EN55022 classA EMC standards ............................... design refer to GB9254, EN55022 classA
Cooling method ............................... convection Cooling method ............................... fan
Weight ............................................ 1.41kg/pcs

Model DC Output Load regul. R&N Efficiency Model DC Output Load regul. R&N Efficiency
HF100W-YS-12 12V 9.0A 0.5% 120mV 81% HF350W-YS-12 12V 29.0A 0.5% 120mV 82%
HF100W-YS-24 24V 4.2A 0.5% 150mV 82% HF350W-YS-24 24V 14.6A 0.5% 150mV 84%
HF100W-YS-36 36V 3.0A 0.5% 150mV 83% HF350W-YS-36 36V 10.0A 0.5% 200mV 85%
HF100W-YS-48 48V 2.2A 0.5% 150mV 84% HF350W-YS-48 48V 7.3A 0.5% 240mV 86%

200W Rain-proof Series 400W Rain-proof Series


High reliability, low cost High reliability, low cost
Suitable for outdoor or damp locations Suitable for outdoor or damp locations
IP21 design IP21 design
Built-in EMI filter Built-in EMI filter
100% full load burn-in test 100% full load burn-in test
Protections: overload/ short circuit Protections: overload/ short circuit
2 years warranty 2 years warranty
217 x 131.6 x 69(mm) 235 x 137 x 67.5(mm)

AC input voltage range ................... 170~264VAC (210~370VDC) AC input voltage range ................... 170~264VAC (210~370VDC)
Input current .................................... max. 2.5A Input current .................................... max. 5.0A
Input frequency .............................. 47~63Hz Input frequency .............................. 47~63Hz
Inrush current .................................. cold start, 40A/230V Inrush current .................................. cold start, 40A/230V
Input leakage current ...................... 0.7mA/ 230VAC Input leakage current ...................... 0.7mA/ 230VAC
Line regulation (full load) ................. 0.5% Line regulation (full load) ................. 0.5%
Output voltage adjust range ........... 10% Output voltage adjust range ........... 10%
Output overload protection ............. 105~150%, hiccup mode, auto recovery Output overload protection ............. 110~130%, shut off, re-power on to recover
Short circuit protection .................... hiccup mode, auto recovery Short circuit protection .................... shut off, re-power on to recover
Withstand voltage ........................... I/P -O/P: 1.5KVAC/1min Withstand voltage ........................... I/P -O/P: 1.5KVAC/1min
I/P -F/G: 1.5KVAC/1min I/P -F/G: 1.5KVAC/1min
O/P-F/G: 0.5KVAC/1min O/P-F/G: 0.5KVAC/1min
Rise time ......................................... 50ms@full load (typical) Rise time ......................................... 50ms@full load (typical)
Hold up time .................................... 20ms@full load (typical) Hold up time .................................... 20ms@full load (typical)
Operating temperature ................... -20 ~+50 Operating temperature ................... -20 ~+50
Safety standards ............................ design refer to GB4943, UL60950, EN60950 Safety standards ............................ design refer to GB4943, UL60950, EN60950
EMC standards ............................... design refer to GB9254, EN55022 classA EMC standards ............................... design refer to GB9254, EN55022 classA
Cooling method ............................... convection Cooling method ............................... fan
Weight ............................................ 1.42kg/pcs

Model DC Output Load regul. R&N Efficiency Model DC Output Load regul. R&N Efficiency
HF200W-YS-12 12V 16.7A 0.5% 120mV 84% HF400W-YS-12 12V 33.0A 0.5% 120mV 82%
HF200W-YS-24 24V 8.3A 0.5% 150mV 85% HF400W-YS-24 24V 17.0A 0.5% 150mV 84%
HF200W-YS-36 36V 5.6A 0.5% 150mV 85% HF400W-YS-36 36V 13.0A 0.5% 200mV 85%
HF200W-YS-48 48V 4.16A 0.5% 150mV 86% HF400W-YS-48 48V 8.3A 0.5% 240mV 86%
5W~35W Open Frame Series
5W Single Output Open Frame Series 25W Single Output Open Frame Series
Universal AC input / full range Protections: overload/ over voltage/ Universal AC input / full range Protections: overload/ over voltage/
High reliability over temperature/ short circuit High reliability over temperature/ short circuit
Miniature PCB structure Free air cooling convection Miniature PCB structure Free air cooling convection
Built-in EMI filter 5 years limited warranty Built-in EMI filter 5 years limited warranty
100% full load burn-in test 76 x 45 x 22(mm) 100% full load burn-in test 107 x 61 x 28(mm)

AC input voltage range ................... 85~264VAC (120~370VDC) AC input voltage range ................... 85~264VAC (120~370VDC)
Inrush current .................................. cold start, 15A/115V, 30A/230V Inrush current .................................. cold start, 20A/115V, 40A/230V
Output voltage adjust range ........... 10% Output voltage adjust range ........... 10%
Output overload protection ............. built-in IC protection, hiccup mode, Output overload protection ............. built-in IC protection, hiccup mode,
auto recovery auto recovery
Output over voltage protection ....... clamping by zenor diode Output over voltage protection ....... 115~150%, shut off, re-power on to recover
Over temp. protection ..................... IC, Tj: 135 , power shutdown Over temp. protection ..................... IC, Tj: 135 , power shutdown
Withstand voltage ........................... I/P-O/P:3.0KVAC/1min;I/P-F/G:1.5KVAC/1min Withstand voltage ........................... I/P-O/P:3.0KVAC/1min;I/P-F/G:1.5KVAC/1min
O/P-F/G:0.5KVAC/1min O/P-F/G:0.5KVAC/1min
Rise, Hold up time .......................... 50ms, 20ms@full load (typical) Rise, Hold up time .......................... 50ms, 20ms@full load (typical)
Operating temperature ................... -20 ~+50 Operating temperature ................... -20 ~+50
Safety standards ............................ meet GB4943, UL60950, EN60950 Safety standards ............................ meet GB4943, UL60950, EN60950
EMC standards ............................... meet GB9254, EN55022 classB, EN61000 EMC standards ............................... meet GB9254, EN55022 classB, EN61000
Connection ...................................... 2P/ 5.08mm, 2P/ 2.54mm pitch Connection ...................................... 2P/ 7.92mm, 4P/ 3.96mm pitch
Weight ............................................ 0.05kg/pcs Weight ............................................ 0.13kg/pcs

Model DC Output Load regul. R&N Efficiency Model DC Output Load regul. R&N Efficiency
HF5W-SPL-5 5V 1.0A 0.5% 80mV 69% HF25W-SPL-5 5V 5.0A 0.5% 80mV 74%
HF5W-SPL-12 12V 0.4A 0.5% 120mV 74% HF25W-SPL-12 12V 2.1A 0.5% 120mV 81%
HF5W-SPL-24 24V 0.2A 0.5% 150mV 75% HF25W-SPL-24 24V 1.1A 0.5% 150mV 81%
HF5W-SPL-48 48V 0.1A 0.5% 150mV 80% HF25W-SPL-48 48V 0.5A 0.5% 150mV 84%
* 3~48VDC output all available. * 3~48VDC output all available.

15W Single Output Open Frame Series 35W Single Output Open Frame Series
Universal AC input / full range Protections: overload/ over voltage/ Universal AC input / full range Protections: overload/ over voltage/
High reliability over temperature/ short circuit High reliability over temperature/ short circuit
Miniature PCB structure Free air cooling convection Miniature PCB structure Free air cooling convection
100% full load burn-in test 5 years limited warranty Built-in EMI filter 5 years limited warranty
UL/ CUL/ CE 100 x 46.2 x 22(mm) 100% full load burn-in test 107 x 61 x 28(mm)

AC input voltage range ................... 85~264VAC (120~370VDC) AC input voltage range ................... 85~264VAC (120~370VDC)
Inrush current .................................. cold start, 15A/115V, 30A/230V Inrush current .................................. cold start, 20A/115V, 40A/230V
Output voltage adjust range ........... 10% Output voltage adjust range ........... 10%
Output overload protection ............. 105~150%, hiccup mode, auto recovery Output overload protection ............. 105~150%, hiccup mode, auto recovery
Output over voltage protection ....... clamping by zenor diode Output over voltage protection ....... 115~150%, shut off, re-power on to recover
Over temp. protection ..................... IC, Tj: 135 , power shutdown Over temp. protection ..................... IC, Tj: 135 , power shutdown
Withstand voltage ........................... I/P-O/P:3.0KVAC/1min;I/P-F/G:1.5KVAC/1min Withstand voltage ........................... I/P-O/P:3.0KVAC/1min;I/P-F/G:1.5KVAC/1min
O/P-F/G:0.5KVAC/1min O/P-F/G:0.5KVAC/1min
Rise, Hold up time .......................... 50ms, 20ms@full load (typical) Rise, Hold up time .......................... 50ms, 20ms@full load (typical)
Operating temperature ................... -20 ~+50 Operating temperature ................... -20 ~+50
Safety standards ............................ GB4943, UL60950, EN60950 Safety standards ............................ meet GB4943, UL60950, EN60950
EMC standards ............................... GB9254, EN55022 classB, EN61000 EMC standards ............................... meet GB9254, EN55022 classB, EN61000
Connection ...................................... 2P/ 5.08mm, 2P/ 3.96mm pitch Connection ...................................... 2P/ 7.92mm, 4P/ 3.96mm pitch
Weight ............................................ 0.09kg/pcs Weight ............................................ 0.16kg/pcs

Model DC Output Load regul. R&N Efficiency Model DC Output Load regul. R&N Efficiency
HF15W-SPL-5 5V 3.0A 0.5% 80mV 73% HF35W-SPL-5 5V 7.0A 0.5% 80mV 76%
HF15W-SPL-12 12V 1.3A 0.5% 120mV 82% HF35W-SPL-12 12V 2.9A 0.5% 120mV 81%
HF15W-SPL-24 24V 0.65A 0.5% 150mV 81% HF35W-SPL-24 24V 1.5A 0.5% 150mV 84%
HF15W-SPL-48 48V 0.32A 0.5% 150mV 85% HF35W-SPL-48 48V 0.7A 0.5% 150mV 83%
* 3~48VDC output all available. * 3~48VDC output all available.
45W~60W Open Frame Series
45W 1~3 Output Open Frame Series 50W Single Output Open Frame Series
Universal AC input / full range Protections: overload/ over voltage/ Universal AC input / full range Protections: overload/ over voltage/
High reliability short circuit High reliability short circuit
Miniature PCB structure Free air cooling convection Miniature PCB structure Free air cooling convection
Built-in EMI filter 5 years limited warranty Built-in EMI filter 5 years limited warranty
100% full load burn-in test 127 x 76.2 x 27(mm) 100% full load burn-in test 195 x 55 x 23(mm)

AC input voltage range ................... 90~264VAC (127~370VDC)


Inrush current .................................. cold start, 40A/230V
Line regulation (full load) ................. 0.5%
Output voltage adjust range ........... 10%
Output overload protection ............. 105~150%, hiccup mode, auto recovery
Output over voltage protection ....... 115~150%, hiccup mode, auto recovery
Withstand voltage ........................... I/P -O/P: 3.0KVAC/1min
I/P -F/G: 1.5KVAC/1min
O/P-F/G: 0.5KVAC/1min
Rise, Hold up time .......................... 50ms, 20ms@full load (typical)
Operating temperature ................... -20 ~+50
Safety standards ............................ meet GB4943, UL60950, EN60950
EMC standards ............................... meet GB9254, EN55022 classB, EN61000
Connection ...................................... 3P/ 7.92mm, 4P/ 3.96mm pitch
AC input voltage range ................... 85~264VAC (120~370VDC) Weight ............................................ 0.22kg/pcs
Inrush current .................................. cold start, 20A/115V, 40A/230V
Input leakage current ...................... 1mA/ 230VAC Model DC Output Load regul. R&N Efficiency
Load regulation ................................ V1: 1%, V2,V 3: 10% HF50W-SPL-5 5V 10.0A 0.5% 80mV 79%
Output voltage adjust range ........... single output: 10%, multi-output: V 1: 5% HF50W-SPL-12 12V 4.2A 0.5% 120mV 83%
Output overload protection ............. 105~150%, hiccup mode, auto recovery
Output over voltage protection ....... 115~150%, shut off, re-power on to recover HF50W-SPL-24 24V 2.1A 0.5% 150mV 85%
Withstand voltage ........................... I/P -O/P: 3.0KVAC/1min HF50W-SPL-48 48V 1.1A 0.5% 150mV 87%
I/P -F/G: 1.5KVAC/1min * 3~48VDC output all available.
O/P-F/G: 0.5KVAC/1min
Rise, Hold up time .......................... 50ms, 20ms@full load (typical)
Operating temperature ................... -20 ~+50
Safety standards ............................ meet GB4943, UL60950, EN60950
60W Single Output Open Frame Series
EMC standards ............................... meet GB9254, EN55022 classB, EN61000 High reliability, low cost Protections: overload/ short circuit
Connection ...................................... 2P/ 7.92mm, 6P/ 3.96mm pitch Miniature PCB structure 5 years limited warranty
Weight ............................................ 0.19kg/pcs (HF45W-SPL) Built-in EMI filter 195 x 55 x 28(mm)
100% full load burn-in test

Single Output
Model DC Output Load regul. R&N Efficiency
HF45W-SPL-5 5V 8.0A 0.5% 80mV 70%
HF45W-SPL-12 12V 3.7A 0.5% 120mV 83%
HF45W-SPL-24 24V 1.9A 0.5% 150mV 85%
HF45W-SPL-48 48V 1.0A 0.5% 150mV 86%
* 3~48VDC output all available.

Dual Output
Model DC Output R&N Efficiency AC input voltage range ................... 170~264VAC (210~370VDC)
Inrush current .................................. cold start, 40A/230V
5V 0.4~5.0A 80mV
HF45W-DPL-A 77% Line regulation (full load) ................. 0.5%
12V 0.2~2.5A 120mV Output voltage adjust range ........... 10%
5V 0.4~5.0A 80mV Output overload protection ............. 105~150%, hiccup mode, auto recovery
HF45W-DPL- B 78% Withstand voltage ........................... I/P -O/P: 1.5KVAC/1min
24V 0.2~1.8A 150mV
I/P -F/G: 1.5KVAC/1min
Triple Output O/P-F/G: 0.5KVAC/1min
Rise, Hold up time .......................... 50ms, 20ms@full load (typical)
Model DC Output R&N Efficiency Operating temperature ................... -20 ~+50
5V 0.4~5.0A 80mV Safety standards ............................ design meet GB4943, UL60950, EN60950
HF45W-TPL-A 12V 0.2~2.5A 120mV 75% EMC standards ............................... design meet GB9254, EN55022 classA
Connection ...................................... 3P/ 7.92mm, 4P/ 3.96mm pitch
-5V 0.1~0.5A 100mV Weight ............................................ 0.21kg/pcs
5V 0.4~5.0A 80mV
HF45W-TPL-B 12V 0.2~2.5A 120mV 75% Model DC Output Load regul. R&N Efficiency
-12V 0.1~0.5A 120mV HF60W-SP-12 12V 5.0A 0.5% 120mV 81%
5V 0.4~5.0A 80mV HF60W-SP-15 15V 4.0A 0.5% 120mV 82%
HF45W-TPL-C 15V 0.2~2.3A 120mV 75% HF60W-SP-24 24V 2.5A 0.5% 150mV 83%
-15V 0.1~0.5A 120mV HF60W-SP-48 48V 1.3A 0.5% 150mV 86%
* 12~48VDC output all available.
65W ~ 100W Open Frame Series
65W 1~3 Output Open Frame Series 100W Open Frame Series - with PFC
Universal AC input / full range Protections: overload/ over voltage/ Universal AC input / full range PF>0.98@115VAC; >0.94@230VAC
High reliability short circuit Protections: overload/ over voltage/ 5 years limited warranty
Miniature PCB structure Free air cooling convection short circuit 222 x 62 x 35.5(mm)
Built-in EMI filter 5 years limited warranty
100% full load burn-in test 127 x 76.2 x 42(mm)

AC input voltage range ................... 85~264VAC (120~370VDC)


Input frequency .............................. 47~63Hz
Inrush current .................................. cold start, 20A/115V, 40A/230V
Input leakage current ...................... 1mA/ 230VAC
Output voltage adjust range ........... 10%
Output overload protection ............. 110~130%, current limiting, auto recovery
Output over voltage protection ....... 115~150%, shut off, re-power on to recover
Withstand voltage ........................... I/P-O/P:3.0KVAC/1min;I/P-F/G:1.5KVAC/1min
O/P-F/G:0.5KVAC/1min
Rise, Hold up time .......................... 50ms, 20ms@full load (typical)
Operating temperature ................... -20 ~+40
Safety standards ............................ meet GB4943, UL60950, EN60950
EMC standards ............................... meet GB9254, EN55022 classB, EN61000
Cooling method ............................... convection
Connection ...................................... 3P/ 7.92mm, 8P/ 3.96mm pitch
Weight ............................................ 0.42kg/pcs

Model DC Output Load regul. R&N Efficiency


AC input voltage range ................... 85~264VAC (120~370VDC) HF100W-SPC-3.3 3.3V 20.0A 0.5% 100mV 71%
Inrush current .................................. cold start, 20A/115V, 40A/230V
HF100W-SPC-5 5V 20.0A 0.5% 100mV 78%
Input leakage current ...................... 1mA/ 230VAC
Load regulation ................................ V1: 1%, V2,V3: 10% HF100W-SPC-7.5 7.5V 13.5A 0.5% 100mV 81%
Output voltage adjust range ........... single output: 10%, multi-output: V 1: 5% HF100W-SPC-12 12V 8.5A 0.5% 120mV 83%
Output overload protection ............. 105~150%, hiccup mode, auto recovery HF100W-SPC-15 15V 6.7A 0.5% 120mV 84%
Output over voltage protection ....... 115~150%, shut off, re-power on to recover
Withstand voltage ........................... I/P -O/P: 3.0KVAC/1min HF100W-SPC-24 24V 4.2A 0.5% 150mV 84%
I/P -F/G: 1.5KVAC/1min HF100W-SPC-48 48V 2.1A 0.5% 150mV 86%
O/P-F/G: 0.5KVAC/1min * 3~48VDC output all available.
Rise, Hold up time .......................... 50ms, 20ms@full load (typical)
Operating temperature ................... -20 ~+50
Safety standards ............................ meet GB4943, UL60950, EN60950
100W Open Frame Series
EMC standards ............................... meet GB9254, EN55022 classB, EN61000 High reliability Protections: overload/ over voltage/
Connection ...................................... 2P/ 7.92mm, 6P/ 3.96mm pitch AC input range selected by switch short circuit
Weight ............................................ 0.25kg/pcs (HF65W-SPL) Built-in EMI filter 5 years limited warranty
Free air cooling convection 222 x 62 x 35.5(mm)

Single Output
Model DC Output Load regul. R&N Efficiency
HF65W-SPL-5 5V 10.0A 0.5% 80mV 76%
HF65W-SPL-12 12V 5.2A 0.5% 120mV 85%
HF65W-SPL-24 24V 2.7A 0.5% 150mV 86%
HF65W-SPL-48 48V 1.35A 0.5% 150mV 87%
* 3~48VDC output all available. AC input voltage range ................... 85~132/ 170~264VAC selected by switch
Input frequency .............................. 40~63Hz
Dual Output Inrush current .................................. cold start, 20A/115V, 40A/230V
Model DC Output R&N Efficiency Input leakage current ...................... 1mA/ 230VAC
Output voltage adjust range ........... 10%
5V 0.4~7.0A 80mV
HF65W-DPL-A 78% Output overload protection ............. 110~130%, shut off, re-power on to recover
12V 0.2~3.2A 120mV Output over voltage protection ....... 115~150%, shut off, re-power on to recover
5V 0.4~6.0A 80mV Withstand voltage ........................... I/P-O/P:3.0KVAC/1min;I/P-F/G:1.5KVAC/1min
HF65W-DPL- B 81% O/P-F/G:0.5KVAC/1min
24V 0.2~2.6A 150mV
Rise, Hold up time .......................... 50ms, 20ms@full load (typical)
Triple Output Operating temperature ................... -20 ~+50
Safety standards ............................ meet GB4943, UL60950, EN60950
Model DC Output R&N Efficiency EMC standards ............................... meet GB9254, EN55022 classB, EN61000
5V 0.4~7.0A 80mV Cooling method ............................... convection
HF65W-TPL-A 12V 0.2~3.2A 120mV 76% Connection ...................................... 3P/ 7.92mm, 8P/ 3.96mm pitch
Weight ............................................ 0.41kg/pcs
-5V 0.2~0.7A 100mV
5V 0.4~7.0A 80mV Model DC Output Load regul. R&N Efficiency
HF65W-TPL-B 12V 0.2~3.2A 120mV 77% HF100W-SPF-5 5V 20.0A 0.5% 100mV 77%
-12V 0.2~0.7A 120mV HF100W-SPF-12 12V 8.5A 0.5% 120mV 81%
5V 0.4~7.0A 80mV HF100W-SPF-15 15V 6.7A 0.5% 120mV 82%
HF65W-TPL-C 15V 0.2~2.6A 120mV 77% HF100W-SPF-24 24V 4.2A 0.5% 150mV 84%
-15V 0.2~0.7A 120mV HF100W-SPF-48 48V 2.1A 0.5% 150mV 85%
* 3~48VDC output all available.
150W~200W / 5W~15W Special Open Frame Series
150W U-Bracket Series 5W DC/DC Open Frame for Telecom
High reliability Protections: overload/ over voltage/ High reliability Protections: overload/ short circuit/
AC input range selected by switch over temperature/ short circuit Compact size over voltage (option)
Built-in EMI filter 5 years limited warranty Miniature PCB structure Free air cooling convection
Free air cooling convection 206 x 103 x 38(mm) Built-in EMI filter 5 years limited warranty
100% full load burn-in test 108 x 35 x 25(mm)

AC input voltage range ................... 85~132/ 170~264VAC selected by switch DC input voltage range ................... 24(18~36)VDC, 48(36~72)VDC
Inrush current .................................. cold start, 20A/115V, 40A/230V Line regulation (full load) ................. 0.5%
Line regulation (full load) ................. 0.5% Output voltage adjust range ........... 10%
Output voltage adjust range ........... 10% Output overload protection ............. 105~150%, hiccup mode, auto recovery
Output overload protection ............. 110~130%, shut off, re-power on to recover Output over voltage protection ....... 115~150% (option)
Output over voltage protection ....... 115~150%, shut off, re-power on to recover Withstand voltage ........................... I/P -O/P: 1.5KVAC/1min
Withstand voltage ........................... I/P -O/P: 3.0KVAC/1min I/P -F/G: 1.5KVAC/1min
I/P -F/G: 1.5KVAC/1min O/P-F/G: 0.5KVAC/1min
O/P-F/G: 0.5KVAC/1min Isolation resistance ......................... 100M @500VDC
Rise, Hold up time .......................... 50ms, 20ms@full load (typical) Operating temperature ................... -20 ~+50
Operating temperature ................... -20 ~+50 Safety standards ............................ design refer to LVD
Safety standards ............................ meet GB4943, UL60950, EN60950 EMC standards ............................... design refer to EN55022, EN61000-4
EMC standards ............................... meet GB9254, EN55022 classB, EN61000 Cooling method ............................... convection
Connection ...................................... 2P/ 3.96mm, 3P/ 6.87mm pitch
Connection ...................................... 3P, 4P/ 9.5mm pitch, terminal block

Model DC Output Load regul. R&N Efficiency


HF150W-SUF-5 5V 30.0A 0.5% 100mV 79%
HF150W-SUF-12 12V 12.5A 0.5% 120mV 85% Model DC Output Load regul. R&N Efficiency
HF150W-SUF-15 15V 10.0A 0.5% 120mV 85% HF5W-SPD**-5 5V 1.0A 0.5% 80mV 78%
HF150W-SUF-24 24V 6.5A 0.5% 150mV 86% HF5W-SPD**-12 12V 0.4A 0.5% 120mV 80%
HF150W-SUF-48 48V 3.1A 0.5% 150mV 86% HF5W-SPD**-24 24V 0.2A 0.5% 150mV 81%
* 3~48VDC output all available. **means DC input voltage, such as 24, 48, etc.

200W Open Frame Series - with PFC 15W Open Frame Series - On Board Type
Universal AC input / full range Protections: overload/ over voltage/ Assemble on the main PCB Protections: overload/ over voltage/
PF>0.98@115VAC; >0.94@230VAC over temperature/ short circuit of the system over temperature/ short circuit
High power density 9.78W/inch3 Free air convection for 150W Universal AC input / full range Free air cooling convection
High efficiency and 200W with 20.5 CFM forced air Miniature PCB structure 5 years limited warranty
ZVS technology to reduce power 5 years limited warranty 100% full load burn-in test 65 x 38 x 30.6(mm)
dissipation 127 x 76.2 x 36(mm)

AC input voltage range ................... 85~264VAC (120~370VDC) AC input voltage range ................... 90~264VAC (127~370VDC)
Inrush current .................................. cold start, 20A/115V, 40A/230V Input leakage current ...................... 0.7mA/ 230VAC
Output voltage adjust range ........... 10% Output voltage adjustment ............. not adjustable
Output overload protection ............. 105~150%, hiccup mode, auto recovery Output overload protection ............. 105~150%, hiccup mode, auto recovery
Output over voltage protection ....... 115~150%, hiccup mode, auto recovery Output over voltage protection ....... clamping by zenor diode
Withstand voltage ........................... I/P-O/P:3.0KVAC/1min;I/P-F/G:1.5KVAC/1min Over temp. protection ..................... IC, Tj: 135 , power shutdown
O/P-F/G:0.5KVAC/1min Withstand voltage ........................... I/P -O/P: 3.0KVAC/1min
Rise, Hold up time .......................... 50ms, 20ms@full load (typical) Rise, Hold up time .......................... 100ms, 5ms@full load (typical)
Operating temperature ................... -20 ~+50 Operating temperature ................... -20 ~+50
Safety standards ............................ meet GB4943, UL60950, EN60950 Safety standards ............................ design meet GB4943, UL60950, EN60950
EMC standards ............................... meet GB9254, EN55022 classB, EN61000 EMC standards ............................... design meet GB9254, EN55022 classA, EN61000
Connection ...................................... 2P/ 7.92mm, 8P/ 3.96mm pitch Cooling method ............................... convection
Weight ............................................ 0.38kg/pcs Weight ............................................ 0.06kg/pcs

Model DC Output Load regul. R&N Efficiency Model DC Output Tolerance R&N Efficiency
HF200W-SPC-5 5V 36.0A 0.5% 100mV 81% HF15W-SPM-5 5V 3.00A 3% 80mV 80%
HF200W-SPC-12 12V 16.6A 0.5% 120mV 85% HF15W-SPM-12 12V 1.25A 3% 120mV 82%
HF200W-SPC-24 24V 8.3A 0.5% 150mV 87% HF15W-SPM-15 15V 1.00A 3% 120mV 83%
HF200W-SPC-48 48V 4.2A 0.5% 150mV 87% HF15W-SPM-24 24V 0.63A 3% 150mV 83%
* 3~48VDC output all available. * 3.3~48VDC output all available.
25W~120W Special Open Frame Series
25W Open Frame for Traffic Light 85~120W Open Frame Series - with PFC
Universal AC input / full range Protections: over voltage/ short circuit High reliability Protections: overload/ over voltage/
PF>0.90@230VAC Constant output current limiting PF>0.92@230VAC short circuit
Miniature PCB structure Free air cooling convection 100% full load burn-in test 5 years limited warranty
5 years limited warranty 105 x 60 x 26(mm) Free air cooling convection 190 x 90 x 33(mm)

Model no. ......................................... HF25W-SPGL-24 AC input voltage range ................... 170~264VAC (210~370VDC)
AC input voltage range ................... 85~264VAC (120~370VDC) Inrush current .................................. cold start, 40A/230V
Input frequency .............................. 47~63Hz Line regulation (full load) ................. 0.5%
Inrush current .................................. cold start, 20A/115V, 40A/230V Output voltage adjust range ........... 10%
Input leakage current ...................... 1mA/ 230VAC Output overload protection ............. 105~150%, hiccup mode, auto recovery
Efficiency ....................................... 80% Output over voltage protection ....... 115~150%, shut off, re-power on to recover
Output voltage ................................ 24VDC, fixed Withstand voltage ........................... I/P -O/P: 3.0KVAC/1min
Output voltage adjust range ........... 10% I/P -F/G: 1.5KVAC/1min
Output current ................................. 0~1A, constant current limiting O/P-F/G: 0.5KVAC/1min
Output current limiting range ........... 100~130%, hiccup mode, auto recovery Rise time ......................................... 50ms@full load (typical)
Line regulation (full load) ................. 2% Hold up time .................................... 20ms@full load (typical)
Load regulation ................................ 2% Operating temperature ................... -20 ~+50
R&N ................................................ 4Vp-p Safety standards ............................ meet GB4943, UL60950, EN60950
Output over voltage protection ....... 115~150% EMC standards ............................... meet GB9254, EN55022 classA, EN61000
Short circuit protection .................... hiccup mode, auto recovery Cooling method ............................... convection
Withstand voltage ........................... I/P -O/P: 3.0KVAC/1min Connection ...................................... 3P/ 7.5mm pitch
Set up time ...................................... 200ms 4P/ 5.0mm pitch, terminal block
Rise, Hold up time .......................... 50ms, 20ms@full load (typical)
Operating temperature ................... -20 ~+50
Safety standards ............................ design meet GB7000.1 Model DC Output Load regul. R&N Efficiency
Cooling method ............................... convection HF85W-SPC-36 36V 2.4A 0.5% 150mV 82%
Connection ...................................... 2P/ 7.5mm pitch
2P/ 5mm pitch, terminal block HF120W-SPC-36 36V 3.3A 0.5% 150mV 84%

100W DC/DC
50~60W U-Bracket
DC/DC Series
for Vehicle LCD 100W DC/DC U-Bracket Series
Wide DC input range Protections: overload/ short circuit High reliability Protections: overload/ over voltage/
High reliability, low cost 5 years limited warranty Input over voltage protection short circuit
100% full load burn-in test 127 x 70 x 32(mm) Input below voltage protection 5 years limited warranty
100% full load burn-in test 201 x 95 x 39(mm)

DC input voltage range ................... 24(9~36)VDC, 48(36~72)VDC DC input voltage range ................... 12(10~18)VDC, 24(18~36)VDC
Line regulation ................................. 1% Line regulation (full load) ................. 0.5%
Output voltage tolerance ................ 3% Output voltage adjust range ........... 10%
Output overload protection ............. 115~180% at min. Vin, hiccup mode, auto Output overload protection ............. 105~150%, hiccup mode, auto recovery
recovery Output over voltage protection ....... 115~150%, hiccup mode, auto recovery
Withstand voltage ........................... I/P -O/P: 1.5KVAC/1min Withstand voltage ........................... I/P -O/P: 1.5KVAC/1min
Rise time ......................................... 50ms@full load (typical) I/P -F/G: 1.5KVAC/1min
Operating temperature ................... -20 ~+50 O/P-F/G: 0.5KVAC/1min
Safety standards ............................ design refer to LVD Rise time ......................................... 50ms@full load (typical)
Cooling method ............................... convection Operating temperature ................... -20 ~+50
Connection ...................................... 4P/ 3.96mm pitch Safety standards ............................ design refer to LVD
6P/ 3.96mm pitch Cooling method ............................... convection
Connection ...................................... 4P/ 9.5mm pitch
4P/ 9.5mm pitch, terminal block
Model DC Output Load regul. R&N Efficiency
Weight ............................................ 0.75kg/pcs
HF50W-SUD**-5 5V 10.0A 1.0% 80mV 73%
HF50W-SUD**-12 12V 3.7A 1.0% 120mV 83% Model DC Output Load regul. R&N Efficiency
HF50W-SUD**-24 24V 2.1A 1.0% 150mV 84% HF100W-SUD**-5 5V 20.0A 1.0% 100mV 75%
HF60W-SUD**-5 5V 12.0A 1.0% 80mV 72% HF100W-SUD**-12 12V 9.0A 0.5% 120mV 73%
HF60W-SUD**-12 12V 5.0A 1.0% 120mV 81% HF100W-SUD**-24 24V 4.5A 0.5% 150mV 76%
**means DC input voltage, such as 24, 48, etc. **means DC input voltage, such as 12, 24, etc.
150~225W Special Open Frame / 10~20W DC/DC Series
150W DC/DC for Bus Battery Charging 10W DC/DC Series
High reliability Protections: overload/ over voltage/ High reliability
V1 isolated from V2, V3 short circuit Built-in EMI filter
V2, V3 common grounded 5 years limited warranty 100% full load burn-in test
100% full load burn-in test 202 x 101.5 x 38(mm) Protections: overload/ short circuit
5 years limited warranty
F601 100 x 58 x 31(mm)

DC input voltage ............................. 12VDC, 24VDC, 48VDC, 90VDC, 110VDC


Line regulation (full load) ................. 0.5%
Load regulation ................................ V1: 0.5%, V2: 3% (with regulator);
10% (without)
Output voltage adjust range ........... single output: 10%, multi-output: V1: 5%
Output overload protection ............. 105~150%, hiccup mode, auto recovery
Withstand voltage ........................... I/P -O/P: 1.5KVAC/1min
I/P -F/G: 1.5KVAC/1min
DC input voltage range ................... 12(10~18)VDC, 24(18~36)VDC O/P-F/G: 0.5KVAC/1min
Line regulation ................................. V1: 0.5%; V2: 1.0%; V3: 0.5% Isolation resistance ......................... 100M @500VDC
Output voltage adjust range ........... V1: 5% of rated output voltage Operating temperature ................... -20 ~+50
Output overload protection ............. 105~180%, hiccup mode, auto recovery Safety standards ............................ design refer to LVD
Output over voltage protection ....... 115~150%, hiccup mode, auto recovery EMC standards ............................... design refer to EN55022, EN61000-4
Withstand voltage ........................... I/P -O/P: 1.5KVAC/1min Cooling method ............................... convection
I/P -F/G: 1.5KVAC/1min
O/P-F/G: 0.5KVAC/1min
Operating temperature ................... -20 ~+50
Safety standards ............................ design refer to LVD Model DC Output R&N Efficiency
Cooling method ............................... convection HF10W-SD**-5 5V 2.0A 80mV 70%
Connection ...................................... 2P/ 3.96mm pitch
12P/ 4.2mm pitch, terminal block HF10W-SD**-12 12V 1.0A 120mV 72%
HF10W-SD**-24 24V 0.5A 150mV 76%
Model DC Output Load regul. R&N Efficiency
5V 0.20~1.8A 80mV
5V 0.8~4.0A 1.0% 100mV HF10W-DD**-A 68%
12V 0.10~0.5A 120mV
HF150W-TUD**-A 12V 0.3~3.0A 8.0% 120mV 80%
5V 0.20~1.8A 80mV
24V 0.0~3.0A 1.0% 150mV HF10W-DD**-B 69%
24V 0.05~0.3A 150mV
5V 0.8~4.0A 1.0% 100mV **means DC input voltage, such as 12, 24, 48, 90, 110, etc.
HF150W-TUD**-B 12V 0.3~3.0A 8.0% 120mV 80%
12V 0.0~6.0A 1.0% 120mV
20W DC/DC Series
**means DC input voltage, such as 12, 24, etc.

High reliability
225W U-Bracket Series - with PFC Built-in EMI filter
100% full load burn-in test
Universal AC input / full range Protections: overload/ over voltage/
Protections: overload/ short circuit
PF>0.98@115VAC; >0.94@230VAC over temperature/ short circuit
5 years limited warranty
Built-in EMI filter 5 years limited warranty
F602 111 x 78 x 36(mm)
Free air convection for 150W 202 x 101.5 x 38(mm)
and 225W with 18 CFM forced air

DC input voltage ............................. 12VDC, 24VDC, 48VDC, 110VDC


Line regulation (full load) ................. 0.5%
Load regulation ................................ V1: 0.5%, V2,V 3: 3% (with regulators);
10% (without)
Output voltage adjust range ........... single output: 10%, multi-output: V1: 5%
Output overload protection ............. 105~150%, hiccup mode, auto recovery
Withstand voltage ........................... I/P -O/P: 1.5KVAC/1min
I/P -F/G: 1.5KVAC/1min
O/P-F/G: 0.5KVAC/1min
Isolation resistance ......................... 100M @500VDC
AC input voltage range ................... 85~264VAC (120~370VDC) Operating temperature ................... -20 ~+50
Inrush current .................................. cold start, 20A/115V, 40A/230V Safety standards ............................ design refer to LVD
EMC standards ............................... design refer to EN55022, EN61000-4
Output voltage adjust range ........... 10%
Cooling method ............................... convection
Output overload protection ............. 110~130%, current limiting, auto recovery
Output over voltage protection ....... 115~150%, shut off, re-power on to recover Model DC Output R&N Efficiency
Withstand voltage ........................... I/P -O/P: 3.0KVAC/1min
I/P -F/G: 1.5KVAC/1min HF20W-SD**-5 5V 4.0A 80mV 70%
O/P-F/G: 0.5KVAC/1min HF20W-SD**-12 12V 2.0A 120mV 72%
Rise, Hold up time .......................... 50ms, 20ms@full load (typical) HF20W-SD**-24 24V 1.0A 150mV 74%
Operating temperature ................... -20 ~+50
Safety standards ............................ meet GB4943, UL60950, EN60950 5V 0.4~3.0A 80mV
HF20W-DD**-A 71%
EMC standards ............................... meet GB9254, EN55022 classB, EN61000 12V 0.0~1.0A 120mV
Connection ...................................... 3P, 12P/ 5mm pitch 12V 0.2~1.2A 120mV
Weight ............................................ 0.80kg/pcs HF20W-DD**-B 72%
12V 0.0~0.8A 120mV
Model DC Output Load regul. R&N Efficiency 5V 0.3~2.5A 80mV
HF225W-SUC-5 5V 40.0A 1.0% 100mV 76% HF20W-TD**-A 12V 0.1~1.0A 120mV 69%
HF225W-SUC-12 12V 18.7A 0.5% 120mV 83% -12V 0.1~0.8A 120mV
HF225W-SUC-15 15V 15.0A 0.5% 120mV 84% 5V 0.3~2.5A 80mV
HF225W-SUC-24 24V 9.4A 0.5% 150mV 86% HF20W-TD**-B 15V 0.1~0.8A 120mV 70%
HF225W-SUC-48 48V 4.7A 0.5% 150mV 87% -15V 0.1~0.8A 120mV
* 3~48VDC output all available. **means DC input voltage, such as 12, 24, 48, 110, etc.
30W~60W DC/DC Series
30W DC/DC Series 50W DC/DC Series
High reliability High reliability
Built-in EMI filter Built-in EMI filter
100% full load burn-in test 100% full load burn-in test
Protections: overload/ short circuit Protections: overload/ short circuit
5 years limited warranty 5 years limited warranty
F603 129 x 98 x 40(mm) F605 160 x 98 x 39(mm)

DC input voltage ............................. 12VDC, 24VDC, 48VDC, 110VDC DC input voltage ............................. 12VDC, 24VDC, 48VDC, 110VDC
Line regulation (full load) ................. 0.5% Line regulation (full load) ................. 0.5%
Load regulation ................................ V1: 0.5%, V2,V 3: 3% (with regulators); Load regulation ................................ V1: 0.5%, V 2,V 3: 3% (with regulators);
10% (without) 10% (without)
Output voltage adjust range ........... single output: 10%, multi-output:V1: 5% Output voltage adjust range ........... single output: 10%, multi-output:V1: 5%
Output overload protection ............. 105~150%, hiccup mode, auto recovery Output overload protection ............. 105~150%, hiccup mode, auto recovery
Withstand voltage ........................... I/P -O/P: 1.5KVAC/1min Withstand voltage ........................... I/P -O/P: 1.5KVAC/1min
I/P -F/G: 1.5KVAC/1min I/P -F/G: 1.5KVAC/1min
O/P-F/G: 0.5KVAC/1min O/P-F/G: 0.5KVAC/1min
Isolation resistance ......................... 100M @500VDC Isolation resistance ......................... 100M @500VDC
Operating temperature ................... -20 ~+50 Operating temperature ................... -20 ~+50
Safety standards ............................ design refer to LVD Safety standards ............................ design refer to LVD
EMC standards ............................... design refer to EN55022, EN61000-4 EMC standards ............................... design refer to EN55022, EN61000-4
Cooling method ............................... convection Cooling method ............................... convection

Model DC Output R&N Efficiency


Model DC Output R&N Efficiency HF50W-SD**-5 5V 10.0A 80mV 71%
HF30W-SD**-12 12V 2.5A 120mV 72% HF50W-SD**-12 12V 4.2A 120mV 72%
HF30W-SD**-24 24V 1.3A 150mV 74% HF50W-SD**-24 24V 2.1A 150mV 74%
5V 0.5~4.0A 80mV 5V 0.5~6.0A 80mV
HF30W-DD**-A 70% HF50W-DD**-A 70%
12V 0.0~1.5A 120mV 12V 0.2~2.5A 120mV
15V 0.2~1.5A 120mV 15V 0.2~2.5A 120mV
HF30W-DD**-B 70% HF50W-DD**-B 71%
-15V 0.0~1.0A 120mV -15V 0.2~2.0A 120mV
5V 0.5~3.5A 80mV 5V 0.5~5.0A 80mV
HF30W-TD**-A 12V 0.1~1.2A 120mV 67% HF50W-TD**-A 12V 0.2~2.0A 120mV 70%
-12V 0.1~0.8A 120mV -12V 0.2~1.5A 120mV
**means DC input voltage, such as 12, 24, 48, 110, etc. **means DC input voltage, such as 12, 24, 48, 110, etc.

40W DC/DC Series 60W DC/DC Series


High reliability High reliability
Built-in EMI filter Built-in EMI filter
100% full load burn-in test 100% full load burn-in test
Protections: overload/ short circuit Protections: overload/ short circuit
5 years limited warranty 5 years limited warranty
F603 129 x 98 x 40(mm) F605 160 x 98 x 39(mm)

DC input voltage ............................. 24VDC, 48VDC, 110VDC DC input voltage ............................. 12VDC, 24VDC, 48VDC, 110VDC
Line regulation (full load) ................. 0.5% Line regulation (full load) ................. 0.5%
Load regulation ................................ V1: 0.5%, V 2,V3: 3% (with regulators); Output voltage adjust range ........... 10%
10% (without) Output overload protection ............. 105~150%, hiccup mode, auto recovery
Output voltage adjust range ........... single output: 10%, multi-output:V1: 5% Withstand voltage ........................... I/P -O/P: 1.5KVAC/1min
Output overload protection ............. 105~150%, hiccup mode, auto recovery I/P -F/G: 1.5KVAC/1min
Withstand voltage ........................... I/P -O/P: 1.5KVAC/1min O/P-F/G: 0.5KVAC/1min
I/P -F/G: 1.5KVAC/1min Isolation resistance ......................... 100M @500VDC
O/P-F/G: 0.5KVAC/1min Operating temperature ................... -20 ~+50
Isolation resistance ......................... 100M @500VDC Safety standards ............................ design refer to LVD
Operating temperature ................... -20 ~+50 EMC standards ............................... design refer to EN55022, EN61000-4
Safety standards ............................ design refer to LVD Cooling method ............................... convection
EMC standards ............................... design refer to EN55022, EN61000-4
Cooling method ............................... convection

Model DC Output R&N Efficiency Model DC Output Load regul. R&N Efficiency
HF40W-SD**-5 5V 8.0A 80mV 70% HF60W-SD**-5 5V 12.0A 0.5% 80mV 70%
HF40W-SD**-12 12V 3.3A 120mV 72% HF60W-SD**-12 12V 5.0A 0.5% 120mV 72%
HF40W-SD**-24 24V 1.6A 150mV 74% HF60W-SD**-24 24V 2.5A 0.5% 150mV 74%
5V 0.5~4.0A 80mV HF60W-SD**-48 48V 1.3A 0.5% 150mV 75%
HF40W-DD**-A 70%
12V 0.0~2.0A 120mV **means DC input voltage, such as 12, 24, 48, 110, etc.
15V 0.2~2.0A 120mV
HF40W-DD**-B 70%
-15V 0.0~1.5A 120mV
5V 0.5~3.5A 80mV


High reliability - Only international brand components
HF40W-TD**-A 12V 0.1~1.5A 120mV 67% are adopted for our key parts. Each unit is given 100%
-12V 0.1~1.0A 120mV load burn-in test before delivery.
**means DC input voltage, such as 24, 48, 110, etc.
70W~200W DC/DC Series
70W DC/DC Series 150W DC/DC Series
High reliability High reliability
Built-in EMI filter Built-in EMI filter
Protections: overload/ short circuit 100% full load burn-in test
5 years limited warranty Protections: overload/ short circuit
F605 160 x 98 x 39(mm) 5 years limited warranty
F608 146 x 81 x 38(mm) (option) F615 199 x 98 x 50(mm)

DC input voltage ............................. 24VDC, 48VDC, 110VDC DC input voltage ............................. 24VDC, 48VDC, 110VDC
Line regulation (full load) ................. 0.5% Line regulation (full load) ................. 0.5%
Output voltage adjust range ........... 10% Output voltage adjust range ........... 10%
Output overload protection ............. 105~150%, hiccup mode, auto recovery Output overload protection ............. 105~150%, hiccup mode, auto recovery
Withstand voltage ........................... I/P -O/P: 1.5KVAC/1min Withstand voltage ........................... I/P -O/P: 1.5KVAC/1min
I/P -F/G: 1.5KVAC/1min I/P -F/G: 1.5KVAC/1min
O/P-F/G: 0.5KVAC/1min O/P-F/G: 0.5KVAC/1min
Isolation resistance ......................... 100M @500VDC Isolation resistance ......................... 100M @500VDC
Operating temperature ................... -20 ~+50 Operating temperature ................... -20 ~+50
Safety standards ............................ design refer to LVD Safety standards ............................ design refer to LVD
EMC standards ............................... design refer to EN55022, EN61000-4 EMC standards ............................... design refer to EN55022, EN61000-4
Cooling method ............................... convection Cooling method ............................... convection

Model DC Output Load regul. R&N Efficiency


HF70W-SD**-12 12V 6.0A 0.5% 120mV 72% Model DC Output Load regul. R&N Efficiency
HF70W-SD**-15 15V 4.7A 0.5% 120mV 72% HF150W-SD**-12 12V 12.5A 0.5% 120mV 72%
HF70W-SD**-24 24V 3.0A 0.5% 150mV 76% HF150W-SD**-24 24V 6.3A 0.5% 150mV 76%
HF70W-SD**-48 48V 1.5A 0.5% 150mV 82% HF150W-SD**-48 48V 3.1A 0.5% 150mV 82%
**means DC input voltage, such as 24, 48, 110, etc. **means DC input voltage, such as 24, 48, 110, etc.

100W DC/DC Series 200W DC/DC Series


High reliability High reliability
Built-in EMI filter Built-in EMI filter
100% full load burn-in test 100% full load burn-in test
Protections: overload/ short circuit Protections: overload/ short circuit
5 years limited warranty 5 years limited warranty
F610 199 x 98 x 39(mm) F620 200 x 110 x 50(mm)

DC input voltage ............................. 24VDC, 48VDC, 110VDC DC input voltage ............................. 24VDC, 48VDC, 110VDC
Line regulation (full load) ................. 0.5% Line regulation (full load) ................. 0.5%
Output voltage adjust range ........... 10% Output voltage adjust range ........... 10%
Output overload protection ............. 105~150%, hiccup mode, auto recovery Output overload protection ............. 105~150%
Withstand voltage ........................... I/P -O/P: 1.5KVAC/1min Withstand voltage ........................... I/P -O/P: 1.5KVAC/1min
I/P -F/G: 1.5KVAC/1min I/P -F/G: 1.5KVAC/1min
O/P-F/G: 0.5KVAC/1min O/P-F/G: 0.5KVAC/1min
Isolation resistance ......................... 100M @500VDC Isolation resistance ......................... 100M @500VDC
Operating temperature ................... -20 ~+50 Operating temperature ................... -20 ~+50
Safety standards ............................ design refer to LVD Safety standards ............................ design refer to LVD
EMC standards ............................... design refer to EN55022, EN61000-4 EMC standards ............................... design refer to EN55022, EN61000-4
Cooling method ............................... convection Cooling method ............................... convection

Model DC Output Load regul. R&N Efficiency Model DC Output Load regul. R&N Efficiency
HF100W-SD**-5 5V 20.0A 0.5% 100mV 74% HF200W-SD**-5 5V 30.0A 0.5% 100mV 72%
HF100W-SD**-12 12V 8.5A 0.5% 120mV 75% HF200W-SD**-12 12V 16.7A 0.5% 120mV 76%
HF100W-SD**-24 24V 4.2A 0.5% 150mV 78% HF200W-SD**-24 24V 8.4A 0.5% 150mV 80%
HF100W-SD**-48 48V 2.1A 0.5% 150mV 79% HF200W-SD**-48 48V 4.2A 0.5% 150mV 84%
**means DC input voltage, such as 24, 48, 110, etc. **means DC input voltage, such as 24, 48, 110, etc.

The company keeps on strict quality control under


ISO9001 quality system certified by SGS.
The leading manufacturer in China of industrial
switching power supplies.


Reliable Products & Best Services
We have full confidence to be your trustworthy
power partner.
UL Certificate CE/LVD Certificate CE/EMC Certificate
200W~1000W DC/DC Series
200W DC/DC Mini-size Series 350~500W DC/DC Mini-size Series

Input over/ below voltage protection Forced air cooling by built-in fan
Input polarity protection Built-in remote sense (option)
Protections: overload/ over voltage/ Remote ON/OFF control (option)
over temperature/ short circuit 100% full load burn-in test
5 years limited warranty Protections: overload/ over voltage/
F620DC 199 x 99 x 50(mm) over temperature/ short circuit
5 years limited warranty
F632C 215 x 115 x 50(mm)
Line regulation (full load) ................. 0.5% Line regulation (full load) ................. 0.5%
Load regulation ................................ 0.5% Load regulation ................................ 0.5%
Output voltage adjust range ........... 10% Output voltage adjust range ........... 10%
Output overload protection ............. 105~150%, hiccup mode, auto recovery Output overload protection ............. 110~130%, delay shutdown, re-power on to
Output over voltage protection ....... 115~150%, hiccup mode, auto recovery recover
Withstand voltage ........................... I/P -O/P: 1.5KVAC/1min Output over voltage protection ....... 115~150%, shut off, re-power on to recover
I/P -F/G: 1.5KVAC/1min Withstand voltage ........................... I/P -O/P: 1.5KVAC/1min
O/P-F/G: 0.5KVAC/1min I/P -F/G: 1.5KVAC/1min
Isolation resistance ......................... 100M @500VDC O/P-F/G: 0.5KVAC/1min
Operating temperature ................... -20 ~+50 Isolation resistance ......................... 100M @500VDC
Safety standards ............................ design refer to LVD Operating temperature ................... -20 ~+50
EMC standards ............................... design refer to EN55022, EN61000-4 Safety standards ............................ design refer to LVD
Cooling method ............................... convection EMC standards ............................... design refer to EN55022, EN61000-4
Cooling method ............................... fan

Model DC Input DC Output R&N Efficiency Model DC Input DC Output R&N Efficiency
HF200W-SMD**-12 19~36V 12V 16.7A 120mV 82% HF350W-SMD**-12 19~36V 12V 27.5A 150mV 80%
HF200W-SMD**-24 19~36V 24V 8.4A 150mV 85% HF350W-SMD**-24 19~36V 24V 14.6A 150mV 80%
HF200W-SMD**-12 36~72V 12V 16.7A 120mV 84% HF350W-SMD**-12 36~72V 12V 27.5A 150mV 81%
HF200W-SMD**-24 36~72V 24V 8.4A 150mV 86% HF350W-SMD**-24 36~72V 24V 14.6A 150mV 81%
HF200W-SMD**-12 72~144V 12V 16.7A 120mV 82% HF350W-SMD**-12 72~144V 12V 29.2A 150mV 83%
HF200W-SMD**-24 72~144V 24V 8.4A 150mV 84% HF350W-SMD**-24 72~144V 24V 14.6A 150mV 87%
**means DC input voltage, such as 24, 48, 110, etc. HF500W-SMD**-12 19~72V 12V 40.0A 150mV 86%
HF500W-SMD**-24 19~72V 24V 21.0A 150mV 88%
300W DC/DC Series HF500W-SMD**-12 72~144V 12V 40.0A 150mV 87%
HF500W-SMD**-24 72~144V 24V 21.0A 150mV 89%
High reliability
**means DC input voltage, such as 24, 48, 110, etc.
Built-in fan speed control
100% full load burn-in test
Protections: overload/ over voltage/
over temperature/ short circuit 500~1000W DC/DC Series
5 years limited warranty
F632C 215 x 115 x 50(mm) High reliability
Built-in EMI filter
100% full load burn-in test
DC input voltage ............................. 24VDC, 48VDC, 110VDC Protections: overload/ over voltage/
Line regulation (full load) ................. 0.5% over temperature/ short circuit
Output voltage adjust range ........... 10% 5 years limited warranty
Output overload protection ............. 105~150%, hiccup mode, auto recovery F650 250 x 160 x 87(mm)
Output over voltage protection ....... 115~150%, shut off, re-power on to recover
Withstand voltage ........................... I/P -O/P: 1.5KVAC/1min
I/P -F/G: 1.5KVAC/1min
DC input voltage ............................. 48VDC, 110VDC
O/P-F/G: 0.5KVAC/1min
Line regulation (full load) ................. 0.5%
Isolation resistance ......................... 100M @500VDC
Output voltage adjust range ........... 10%
Operating temperature ................... -20 ~+50
Output overload protection ............. 110~130%, current limiting, auto recovery
Safety standards ............................ design refer to LVD
Output over voltage protection ....... 115~150%, shut off, re-power on to recover
EMC standards ............................... design refer to EN55022, EN61000-4
Withstand voltage ........................... I/P -O/P: 1.5KVAC/1min
Cooling method ............................... fan
I/P -F/G: 1.5KVAC/1min
O/P-F/G: 0.5KVAC/1min
Isolation resistance ......................... 100M @500VDC
Model DC Output Load regul. R&N Efficiency Operating temperature ................... -20 ~+50
HF300W-SD**-12 12V 25.0A 0.5% 150mV 82% Safety standards ............................ design refer to LVD
EMC standards ............................... design refer to EN55022, EN61000-4
HF300W-SD**-15 15V 20.0A 0.5% 150mV 83% Cooling method ............................... fan
HF300W-SD**-24 24V 12.5A 0.5% 150mV 85%
HF300W-SD**-48 48V 6.3A 0.5% 240mV 88%
**means DC input voltage, such as 24, 48, 110, etc. Model DC Output Load regul. R&N Efficiency
HF500W-SD**-12 12V 42A 0.5% 150mV 82%
HF500W-SD**-24 24V 21A 0.5% 150mV 82%
For more details, we sincerely invite you to visit HF500W-SD**-48 48V 11A 0.5% 240mV 84%
our website: www.hengfu.com HF600W-SD**-48 48V 13A 0.5% 240mV 84%
HF700W-SD**-24 24V 29A 0.5% 150mV 82%
HF800W-SD**-24 24V 35A 0.5% 150mV 82%
HF800W-SD**-48 48V 17A 0.5% 240mV 84%


We were honoured to offer power supplies for Beijing
Olympic Games, 60th National anniversary ceremony HF1000W-SD**-24 24V 42A 0.5% 150mV 82%
and Shanghai Expo2010. HF1000W-SD**-48 48V 21A 0.5% 240mV 84%
**means DC input voltage, such as 48, 110, etc.
40W~150W Single Output Telecom Series
40W Single Output Telecom Series 100W Single Output Telecom Series
Wide AC input range Wide AC input range
Wide operating temperature Wide operating temperature
Built-in lightningproof 3000A (8/20us) Built-in lightningproof 3000A (8/20us)
AC input failure signal (option) AC input failure signal (option)
Protections: overload/ over voltage/ Protections: overload/ over voltage/
short circuit short circuit
5 years limited warranty 5 years limited warranty
F603 129 x 98 x 40(mm) F610 199 x 98 x 39(mm)

AC input voltage range ................... 160~280VAC (210~370VDC) AC input voltage range ................... 160~280VAC (210~370VDC)
AC input voltage range (option) ...... 85~280VAC (120~370VDC) Input frequency .............................. 47~63Hz
Input frequency .............................. 47~63Hz Inrush current .................................. cold start, 40A/230V
Inrush current .................................. cold start, 40A/230V Input leakage current ...................... 0.7mA/ 230VAC
Input leakage current ...................... 0.7mA/ 230VAC Line regulation (full load) ................. 0.5%
Line regulation (full load) ................. 0.5% Output voltage adjust range ........... 10%
Output voltage adjust range ........... 10% Output overload protection ............. 110~130%, shut off, re-power on to recover
Output overload protection ............. 105~150%, hiccup mode, auto recovery Output over voltage protection ....... 115~150%, shut off, re-power on to recover
Output over voltage protection ....... 115~150%, hiccup mode, auto recovery Withstand voltage ........................... I/P -O/P: 3.0KVAC/1min
Withstand voltage ........................... I/P -O/P: 3.0KVAC/1min (gas tube must be deleted when test) I/P -F/G: 1.5KVAC/1min
(gas tube must be deleted when test) I/P -F/G: 1.5KVAC/1min O/P-F/G: 0.5KVAC/1min
O/P-F/G: 0.5KVAC/1min Rise time ......................................... 50ms@full load (typical)
Rise time ......................................... 50ms@full load (typical) Hold up time .................................... 20ms@full load (typical)
Hold up time .................................... 20ms@full load (typical) Operating temperature ................... -25 ~+65
Operating temperature ................... -25 ~+65 Safety standards ............................ design meet GB4943, UL60950, EN60950
Safety standards ............................ design meet GB4943, UL60950, EN60950 EMC standards ............................... design meet GB9254, EN55022 classB
EMC standards ............................... design meet GB9254, EN55022 classB EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11
EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11 Cooling method ............................... convection
Cooling method ............................... convection

Model DC Output Load regul. R&N Efficiency Model DC Output Load regul. R&N Efficiency
HF40W-ST-12 12V 3.5A 0.5% 120mV 80% HF100W-ST-12 12V 9.0A 0.5% 120mV 82%
HF40W-ST-13.5 13.5V 3.0A 0.5% 120mV 80% HF100W-ST-13.5 13.5V 7.4A 0.5% 120mV 83%
HF40W-ST-24 24V 1.8A 0.5% 150mV 82% HF100W-ST-24 24V 4.5A 0.5% 150mV 84%
HF40W-ST-27 27V 1.5A 0.5% 150mV 83% HF100W-ST-27 27V 3.7A 0.5% 150mV 85%
HF40W-ST-48 48V 0.9A 0.5% 150mV 84% HF100W-ST-48 48V 2.2A 0.5% 150mV 87%

70W Single Output Telecom Series 150W Single Output Telecom Series
Wide AC input range Wide AC input range
Wide operating temperature Wide operating temperature
Built-in lightningproof 3000A (8/20us) Built-in lightningproof 3000A (8/20us)
AC input failure signal (option) AC input failure signal (option)
Protections: overload/ over voltage/ Protections: overload/ over voltage/
short circuit short circuit
5 years limited warranty 5 years limited warranty
F605 160 x 98 x 39(mm) F615 199 x 98 x 50(mm)

AC input voltage range ................... 160~280VAC (210~370VDC) AC input voltage range ................... 160~280VAC (210~370VDC)
AC input voltage range (option) ...... 85~280VAC (120~370VDC) Input frequency .............................. 47~63Hz
Input frequency .............................. 47~63Hz Inrush current .................................. cold start, 40A/230V
Inrush current .................................. cold start, 40A/230V Input leakage current ...................... 0.7mA/ 230VAC
Input leakage current ...................... 0.7mA/ 230VAC Line regulation (full load) ................. 0.5%
Line regulation (full load) ................. 0.5% Output voltage adjust range ........... 10%
Output voltage adjust range ........... 10% Output overload protection ............. 110~130%, shut off, re-power on to recover
Output overload protection ............. 105~150%, hiccup mode, auto recovery Output over voltage protection ....... 115~150%, shut off, re-power on to recover
Output over voltage protection ....... 115~150%, hiccup mode, auto recovery Withstand voltage ........................... I/P -O/P: 3.0KVAC/1min
Withstand voltage ........................... I/P -O/P: 3.0KVAC/1min (gas tube must be deleted when test) I/P -F/G: 1.5KVAC/1min
(gas tube must be deleted when test) I/P -F/G: 1.5KVAC/1min O/P-F/G: 0.5KVAC/1min
O/P-F/G: 0.5KVAC/1min Rise time ......................................... 50ms@full load (typical)
Rise time ......................................... 50ms@full load (typical) Hold up time .................................... 20ms@full load (typical)
Hold up time .................................... 20ms@full load (typical) Operating temperature ................... -25 ~+65
Operating temperature ................... -25 ~+65 Safety standards ............................ design meet GB4943, UL60950, EN60950
Safety standards ............................ design meet GB4943, UL60950, EN60950 EMC standards ............................... design meet GB9254, EN55022 classB
EMC standards ............................... design meet GB9254, EN55022 classB EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11
EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11 Cooling method ............................... convection
Cooling method ............................... convection

Model DC Output Load regul. R&N Efficiency Model DC Output Load regul. R&N Efficiency
HF70W-ST-12 12V 6.0A 0.5% 120mV 82% HF150W-ST-12 12V 12.5A 0.5% 120mV 85%
HF70W-ST-13.5 13.5V 5.2A 0.5% 120mV 82% HF150W-ST-13.5 13.5V 11.1A 0.5% 120mV 85%
HF70W-ST-24 24V 3.0A 0.5% 150mV 83% HF150W-ST-24 24V 6.3A 0.5% 150mV 85%
HF70W-ST-27 27V 2.6A 0.5% 150mV 83% HF150W-ST-27 27V 5.6A 0.5% 150mV 87%
HF70W-ST-48 48V 1.5A 0.5% 150mV 84% HF150W-ST-48 48V 3.1A 0.5% 150mV 89%
200~400W Single / 70~100W Dual Output Telecom Series
200W Single Output Telecom Series 70W Dual Output Telecom Series
Wide AC input range Wide AC input range
Wide operating temperature Wide operating temperature
Built-in lightningproof 3000A (8/20us) Built-in lightningproof 3000A (8/20us)
AC input failure signal (option) 100% full load burn-in test
Protections: overload/ over voltage/ Protections: overload/ over voltage/
short circuit short circuit
5 years limited warranty 5 years limited warranty
F620 200 x 110 x 50(mm) F605 160 x 98 x 39(mm)

AC input voltage range ................... 160~280VAC (210~370VDC) AC input voltage range ................... 160~280VAC (210~370VDC)
Input frequency .............................. 47~63Hz AC input voltage range (option) ...... 85~280VAC (120~370VDC)
Inrush current .................................. cold start, 40A/230V Input frequency .............................. 47~63Hz
Input leakage current ...................... 0.7mA/ 230VAC Inrush current .................................. cold start, 40A/230V
Line regulation (full load) ................. 0.5% Input leakage current ...................... 0.7mA/ 230VAC
Output voltage adjust range ........... 10% Line regulation (full load) ................. 0.5%
Output overload protection ............. 110~130%, shut off, re-power on to recover Output voltage adjust range ........... V1: 5% of rated output voltage
Output over voltage protection ....... 115~150%, shut off, re-power on to recover Output overload protection ............. 105~150%, hiccup mode, auto recovery
Withstand voltage ........................... I/P -O/P: 3.0KVAC/1min Output over voltage protection ....... 115~150%, hiccup mode, auto recovery
(gas tube must be deleted when test) I/P -F/G: 1.5KVAC/1min Withstand voltage ........................... I/P -O/P: 3.0KVAC/1min
O/P-F/G: 0.5KVAC/1min (gas tube must be deleted when test) I/P -F/G: 1.5KVAC/1min
Rise time ......................................... 50ms@full load (typical) O/P-F/G: 0.5KVAC/1min
Hold up time .................................... 20ms@full load (typical) Rise time ......................................... 50ms@full load (typical)
Operating temperature ................... -25 ~+65 Hold up time .................................... 20ms@full load (typical)
Safety standards ............................ design meet GB4943, UL60950, EN60950 Operating temperature ................... -25 ~+65
EMC standards ............................... design meet GB9254, EN55022 classA Safety standards ............................ design meet GB4943, UL60950, EN60950
Cooling method ............................... convection EMC standards ............................... design meet GB9254, EN55022 classB
EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11
Cooling method ............................... convection

Model DC Output Load regul. R&N Efficiency


Model DC Output Load regul. R&N Efficiency 27V 2.3A 0.5% 150mV
HF70W-DT-A 81%
HF200W-ST-12 12V 16.7A 0.5% 120mV 85% 9V 1.0A 3.0% 100mV
HF200W-ST-13.5 13.5V 14.8A 0.5% 120mV 85% 27V 2.2A 0.5% 150mV
HF70W-DT-B 81%
HF200W-ST-24 24V 8.3A 0.5% 150mV 86% 12V 1.0A 3.0% 120mV
HF200W-ST-27 27V 8.0A 0.5% 150mV 86% 24V 2.4A 0.5% 150mV
HF70W-DT-C 79%
HF200W-ST-48 48V 4.2A 0.5% 150mV 88% 12V 1.0A 3.0% 120mV

300~400W Single Output Telecom Series 100W Dual Output Telecom Series
Wide AC input range Wide AC input range
Wide operating temperature Wide operating temperature
Built-in lightningproof 3000A (8/20us) Built-in lightningproof 3000A (8/20us)
AC input failure signal (option) 100% full load burn-in test
Protections: overload/ over voltage/ Protections: overload/ over voltage/
over temperature/ short circuit short circuit
5 years limited warranty 5 years limited warranty
F630 241 x 124 x 65(mm) F610 199 x 98 x 39(mm)

AC input voltage range ................... 160~280VAC (210~370VDC) AC input voltage range ................... 160~280VAC (210~370VDC)
Input frequency .............................. 47~63Hz Input frequency .............................. 47~63Hz
Inrush current .................................. cold start, 40A/230V Inrush current .................................. cold start, 40A/230V
Input leakage current ...................... 0.7mA/ 230VAC Input leakage current ...................... 0.7mA/ 230VAC
Line regulation (full load) ................. 0.5% Line regulation (full load) ................. 0.5%
Output voltage adjust range ........... 10% Output voltage adjust range ........... V1: 5% of rated output voltage
Output overload protection ............. 110~130%, current limiting, auto recovery Output overload protection ............. 110~130%, shut off, re-power on to recover
Output over voltage protection ....... 115~150%, shut off, re-power on to recover Output over voltage protection ....... 115~150%, shut off, re-power on to recover
Withstand voltage ........................... I/P-O/P:3.0KVAC/1min;I/P-F/G:1.5KVAC/1min Withstand voltage ........................... I/P -O/P: 3.0KVAC/1min
(gas tube must be deleted when test) O/P-F/G:0.5KVAC/1min (gas tube must be deleted when test) I/P -F/G: 1.5KVAC/1min
Rise time ......................................... 50ms@full load (typical) O/P-F/G: 0.5KVAC/1min
Hold up time .................................... 20ms@full load (typical) Rise, Hold up time ......................... 50ms, 20ms@full load (typical)
Operating temperature ................... -25 ~+65 Operating temperature ................... -25 ~+65
Safety standards ............................ design meet GB4943, UL60950, EN60950 Safety standards ............................ design meet GB4943, UL60950, EN60950
EMC standards ............................... design meet GB9254, EN55022 classA EMC standards ............................... design meet GB9254, EN55022 classB
Cooling method ............................... fan EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11
Cooling method ............................... convection

Model DC Output Load regul. R&N Efficiency


HF300W-ST-12 12V 25.0A 0.5% 150mV 84%
HF300W-ST-24 24V 12.5A 0.5% 150mV 85% Model DC Output Load regul. R&N Efficiency
HF300W-ST-27 27V 11.1A 0.5% 200mV 85% 27V 3.0A 0.5% 150mV
HF100W-DT-A 82%
HF300W-ST-48 48V 6.3A 0.5% 240mV 88% 9V 3.0A 3.0% 100mV
HF400W-ST-13.5 13.5V 29.6A 0.5% 150mV 85% 27V 3.0A 0.5% 150mV
HF100W-DT-B 83%
HF400W-ST-24 24V 17.0A 0.5% 150mV 86% 12V 2.0A 3.0% 120mV
HF400W-ST-27 27V 15.0A 0.5% 200mV 86% 24V 3.2A 0.5% 150mV
HF100W-DT-C 80%
HF400W-ST-48 48V 8.3A 0.5% 240mV 88% 12V 2.0A 3.0% 120mV
150W~300W Dual Output Telecom Series
150W Dual Output Telecom Series 300W Dual Output Telecom Series
Wide AC input range Wide AC input range
Wide operating temperature Wide operating temperature
Built-in lightningproof 3000A (8/20us) Built-in lightningproof 3000A (8/20us)
100% full load burn-in test AC input failure signal (option)
Protections: overload/ over voltage/ Protections: overload/ over voltage/
short circuit over temperature/ short circuit
5 years limited warranty 5 years limited warranty
F615 199 x 98 x 50(mm) F630 241 x 124 x 65(mm)

AC input voltage range .................... 160~280VAC (210~370VDC) AC input voltage range .................... 160~280VAC (210~370VDC)
Input frequency ................................ 47~63Hz Input frequency ................................ 47~63Hz
Inrush current ................................... cold start, 40A/230V Inrush current ................................... cold start, 40A/230V
Input leakage current ....................... 0.7mA/ 230VAC Input leakage current ....................... 0.7mA/ 230VAC
Line regulation (full load) .................. 0.5% Line regulation (full load) .................. 0.5%
Output voltage adjust range ............ V1: 5% of rated output voltage Output voltage adjust range ............ V1: 5% of rated output voltage
Output overload protection .............. 110~130%, shut off, re-power on to recover Output overload protection .............. 110~130%, current limiting, auto recovery
Output over voltage protection ....... 115~150%, shut off, re-power on to recover Output over voltage protection ....... 115~150%, shut off, re-power on to recover
Withstand voltage ............................ I/P -O/P: 3.0KVAC/1min Withstand voltage ............................ I/P -O/P: 3.0KVAC/1min
(gas tube must be deleted when test) I/P -F/G: 1.5KVAC/1min (gas tube must be deleted when test) I/P -F/G: 1.5KVAC/1min
O/P-F/G: 0.5KVAC/1min O/P-F/G: 0.5KVAC/1min
Rise time .......................................... 50ms@full load (typical) Rise time .......................................... 50ms@full load (typical)
Hold up time ..................................... 20ms@full load (typical) Hold up time ..................................... 20ms@full load (typical)
Operating temperature .................... -25 ~+65 Operating temperature .................... -25 ~+65
Safety standards ............................. design meet GB4943, UL60950, EN60950 Safety standards ............................. design meet GB4943, UL60950, EN60950
EMC standards ................................. design meet GB9254, EN55022 classB EMC standards ................................. design meet GB9254, EN55022 classA
EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11 Cooling method ................................ fan
Cooling method ................................ convection

Model DC Output Load regul. R&N Efficiency Model DC Output Load regul. R&N Efficiency
27V 4.5A 0.5% 150mV 27V 10.0A 0.5% 200mV
HF150W-DT-A 80% HF300W-DT-A 84%
9V 3.0A 3.0% 100mV 9V 3.0A 3.0% 100mV
27V 4.0A 0.5% 150mV 27V 10.0A 0.5% 200mV
HF150W-DT-B 79% HF300W-DT-B 84%
12V 3.0A 3.0% 120mV 12V 3.0A 3.0% 120mV
24V 5.0A 0.5% 150mV 24V 11.0A 0.5% 150mV
HF150W-DT-C 79% HF300W-DT-C 84%
12V 2.0A 3.0% 120mV 12V 3.0A 3.0% 120mV

200W Dual Output Telecom Series If you have any question of product application or

Wide AC input range


technical problem, our professional engineers are
ready to give assistance.
V
Wide operating temperature
Built-in lightningproof 3000A (8/20us)
AC input failure signal (option)
Protections: overload/ over voltage/
short circuit
5 years limited warranty
F620 200 x 110 x 50(mm)

AC input voltage range .................... 160~280VAC (210~370VDC)


Input frequency ................................ 47~63Hz
Inrush current ................................... cold start, 40A/230V
Input leakage current ....................... 0.7mA/ 230VAC
Line regulation (full load) .................. 0.5%
Output voltage adjust range ............ V1: 5% of rated output voltage
Output overload protection .............. 110~130%, shut off, re-power on to recover
Output over voltage protection ....... 115~150%, shut off, re-power on to recover
Withstand voltage ............................ I/P -O/P: 3.0KVAC/1min
(gas tube must be deleted when test) I/P -F/G: 1.5KVAC/1min
O/P-F/G: 0.5KVAC/1min
Rise time .......................................... 50ms@full load (typical)
Hold up time ..................................... 20ms@full load (typical)
Operating temperature .................... -25 ~+65
Safety standards ............................. design meet GB4943, UL60950, EN60950
EMC standards ................................. design meet GB9254, EN55022 classA
Cooling method ................................ convection

Model DC Output Load regul. R&N Efficiency


27V 6.0A 0.5% 150mV
HF200W-DT-A 86%
9V 3.0A 3.0% 100mV
27V 6.0A 0.5% 150mV
HF200W-DT-B 83%
12V 3.0A 3.0% 120mV
24V 6.8A 0.5% 150mV
HF200W-DT-C 84%
12V 3.0A 3.0% 120mV
Drawing
Drawing
Drawing
Drawing
Instructions
Technical Instructions & Safety Precautions:
1. Test condition:
(1) All parameters are measured at 230VAC input, rated load and 25 of ambient temperature.
(2) Line regulation is measured from low line to high line at rated load.
(3) Load regulation is measured from 0% to 100% of rated load for single output models. For multi-output models, it is
measured from 20% to 100% of rated load, and other output at 60% rated load.
(4) Ripple & noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1uF & 47uF
parallel capacitor.
(5) The power supply is regarded as a component which will be installed into a final equipment. The final equipment must be
re-confirmed that it still meets EMC directives.

2. Input voltage: Normally, power supplies with AC input can also be applied to DC input. The DC input voltage range shall be
120- 370VDC when the AC input voltage range is 85-264VAC; and 210-370VDC when the AC input voltage range is 170-264VAC,
or 85-132VAC/170-264VAC selected by switch.

3. Input inrush current: is the maximum peak current when cold start of the power supply.

4. Leakage current: When several sets of power supplies connected to ground at the same place, the leakage current will
be redoubled accordingly. Care must be taken to avoid electric shock.

5. Output ripple and noise:


As shown in fig.1, the ripple and noise of a switching power supply is
NOISE
normally specified by the peak to peak amplitude, and is made up of PWM FREQUENCY RIPPLE
SWITCHING
four AC components which can be identified: NOISE
(1) Low frequency ripple at 2f being of the AC mains frequency.
(2) High frequency ripple due to Pulse Width Modulation (PWM) to obtain
RECTIFIED MAIN RIPPLE
the required line and load regulation.
(3) The switching noise that has the same frequency of the switching 10ms
PWM.
(4) The aperiodic random noise that is not related to the AC source
frequency and/or the switching frequency.

6. Multi-output power supplies: For power supplies with multi-output, in our catalog it shows the maximum output current of
each output . But the total power of all outputs shall be within the rated power of the series.
For multi-output products, normally V1 is isolated from the other output(s). To make it common grounded, just connect +/-
(accordingly) of V1 to the common connector of the other output(s).

7. Battery charger: Most of our single output power supplies above 100W can be directly used as battery charger by means of
floating charge (constant current limiting).

8. Operating temperature: means the surrounding temperature of the

9. MTBF: is calculated according to MIL-HFBK-217F formular. It is based on calculation of average lifetime of the key components,
and the statistics of the working situation of many similar equipment, not considering abnormal working situation of power
supplies, air pollution, etc.

10. Torque of screw driver: normally 5kgs to connect wires into the screw terminal blocks.

11. Mounting screws: max. length 6mm.

Warranty Policy:
(1) Products found to be defective within 30 days from the date of receipt can be returned for credit or exchange. After the initial
30 days, we will repair the goods according to our warranty period. Contact us for further information on credit or a RMA
number. Defective units should be shipped as “freight prepaid” to us and we will repair and return the goods (freight prepaid).
Within 2 years, the repairing is free of charge. From 3rd to 5th year (some products), we will collect reasonable charge
for defective components replaced. If the warranty period has expired, a repair fee (20% of the original purchase price or min.
USD5.00/pcs) will be charged.

(2) If customers do the repair by themselves, we can provide reasonable quantity of free components for repair purpose.