Vous êtes sur la page 1sur 2

CO UR S E D E S CR I P TI O N

CHP155 – Relion® 670/650 series with


PCM600 for Grid Protection Solutions –
Configuration

Course goal
The participants acquire in-depth product knowledge that enables them to implement line protection
solutions in practice. They are using the operating program PCM600 to manage, structure, configure
and program a protection application. They are able to integrate an RE.670/650 into an SA system.

Main learning objectives Prerequisites


The participants will be able to: Engineering degree, technical college qualifica-
— Understand product/system architecture tions or equivalent. Basics of protection and
and its ordering specification substation automation as well as PC based data
— Describe the tool environment and installa- processing.
tion Required course or relevant experience:
— Explain the basic configuration principle — CHP102 Protection for Electrical Power Sys-
— Configure hardware, alarms and event han- tems
dling Recommended courses or equivalent experi-
— Implement grid protection application solu- ence:
tions with the tool on the training models — CHP107 Digital Substation Automation Sys-
— Configure the communication interface tems
— Configure fault recording function handling — CHP115 Relion® 670/650 series with PCM600
— Realize additional logic with the logic editor — CHP132 Protection for Transmission Lines
e.g. trip scheme
— Implement modifications in the system such Topics
as additional alarms, graphic displays and — Product/System architecture
functions HW/SW structure, system layout and compo-
— Identify possible cyber security features nents, applications, identification, technical
— Test and verify the implemented application data, functionality, documentation
example — Operating program overview and concepts
— Troubleshoot the system, using the applica- Tool environment, function library, data dis-
tion and configuration manual play, application concept, configuration prin-
ciple, system integration
Copyright© 2019 ABB All rights reserved

Participant profile — Applied examples


Consultants and employees from the elec- E.g. Line, Line Diff and Transformer protec-
tricity supply industry. Technical personnel tion, creation of the function block diagram
of ABB companies. with signal configuration
— Testing of products or system
Application verification, troubleshooting and
diagnostic, safety instructions


ABB Switzerland Ltd
Learning Center Grid Automation 2018-12-01
Bruggerstrasse 72 http://new.abb.com/service/abb-university/ch/lc-ga
CH-5400 Baden ch-lc-ga@abb.com
+41 58 585 65 53 ABB MyLearning
1 /2
Course type To Register:
This is a face to face class room training with LMS:-MyLearning
maximum 12 participants. Sign In: Click SIGN IN to Sign-up or
Log-in with your myABB account.
Learning methods and tools Search: please enter course number or
Lectures, demonstrations, exercises and hands- title into the search field. (Please
on. check the language filter)
Laptop or tablet is required to have access to Unable to Sign In? Find a solution here
the e-documentation. Please bring your own de- The latest version of the course portfolio, and
vice course schedule can be found on our
Learning Center Webpage
Duration
5 days (till Friday noon

2 /2

Vous aimerez peut-être aussi