Volume I
Prepared by:
Khung (Sam) Foo (Data Analyst)
Checked by:
Harry Nomikoudis (Department Manager – Data Evaluation)
Approved by:
Neil Pain (Project Manager)
page 2
Client EXXON MOBIL INDONESIA Inspection Technologies
Contract Number n/a www.RosenInspection.net
Date March 26, 2010
ROSEN Project No. 8-6200-11486
ROSEN Line Name 30NSANSO
Inspection Type CDP / EGP
Revision Number 0
1 | Introduction 5
2 | Management Summary 6
3 | ROSOFT 14
page 3
Client EXXON MOBIL INDONESIA Inspection Technologies
Contract Number n/a www.RosenInspection.net
Date March 26, 2010
ROSEN Project No. 8-6200-11486
ROSEN Line Name 30NSANSO
Inspection Type CDP / EGP
Revision Number 0
8 | Attachments 26
Appendix
page 4
Client EXXON MOBIL INDONESIA Inspection Technologies
Contract Number n/a www.RosenInspection.net
Date March 26, 2010
ROSEN Project No. 8-6200-11486
ROSEN Line Name 30NSANSO
Inspection Type CDP / EGP
Revision Number 0
1 | Introduction
This report describes the pipeline inspection carried out by ROSEN in the 30 inch
102.25 km Gas Pipeline from NSO A Launcher Barrel to NSO Plant Receiver Barrel in
January 2010.
In general, the format of this Inspection Report is in line with the 'Specifications and
Requirements for Intelligent Pig Inspection of Pipelines, Version 3.2', as subscribed by
the members of the Pipeline Operator Forum (hereafter referred to as 'POF').
The inspection results in detail are given in section 10, ‘Inspection Results’.
We hereby would like to take the opportunity to thank EXXON MOBIL INDONESIA for
the assistance and co-operation received during the course of this project.
Note A summary of all abbreviations used is given in the Appendix ‘Terms and Definitions’.
page 5
Client EXXON MOBIL INDONESIA Inspection Technologies
Contract Number n/a www.RosenInspection.net
Date March 26, 2010
ROSEN Project No. 8-6200-11486
ROSEN Line Name 30NSANSO
Inspection Type CDP / EGP
Revision Number 0
2 | Management Summary
Section 2 of this report describes the general condition of the inspected pipeline. For more
detailed findings please refer to section 10, ‘Inspection Results’.
The data recorded during the inspection was checked in several independent steps for
completeness and quality.
The data is automatically searched for all pipeline components and anomalies. This is
achieved utilizing the ROSEN Automated Feature Search Software (AFS). Thereafter,
evaluation personnel interactively verify the results. All results are stored in database
files (.dbf).
All anomalies recorded and detected above the reporting threshold (see section 2.3,
‘Metal Loss Inspection’) are listed in this report.
In the event of single corrosion anomalies in close proximity to one another, interaction
rules may apply and the anomalies are clustered in accordance with the specifications.
The coordinates of the cluster refer to the start point of the cluster, the depth of the
cluster refers to the max. anomaly depth in the cluster. A description of the clustering
routine and a graphic description of the cluster coordinates as well as details about the
classification of anomalies are given in the Appendix, ‘Terms and Definitions’.
All distances are given in meters [m]. Upstream distances are signed with a minus sign
(-), whilst downstream distances have no sign. All anomalies are referenced to the
upstream girth weld.
The recorded CDP centre distance of the first valve in the launcher station has been set
to 0.001 m and is used as a reference distance. Please note that the recorded distance
has been adapted to the 2005 inspection log distance.
page 6
Client EXXON MOBIL INDONESIA Inspection Technologies
Contract Number n/a www.RosenInspection.net
Date March 26, 2010
ROSEN Project No. 8-6200-11486
ROSEN Line Name 30NSANSO
Inspection Type CDP / EGP
Revision Number 0
For detailed information, including information about any restrictions, please refer to section
6, ‘Data Quality’ and section 10, ‘Inspection Results’.
Note A differentiation between internal and non-internal has been performed for all metal loss
anomalies. For all other non metal loss anomalies recorded in weld areas (Heat Affected
Zone - HAZ), distinctions may not be provided. Furthermore, it should be noted that mid-
wall anomalies may be classified as ‘non-internal’.
For all anomalies caused by corrosion an Estimated Repair Factor (ERF) has been
calculated in accordance with ASME B31G Code. The formula used is given in the
Appendix ‘Terms and Definitions’.
page 7
Client EXXON MOBIL INDONESIA Inspection Technologies
Contract Number n/a www.RosenInspection.net
Date March 26, 2010
ROSEN Project No. 8-6200-11486
ROSEN Line Name 30NSANSO
Inspection Type CDP / EGP
Revision Number 0
≥ 60 % 0
40 – 59 % 0
20 – 39 % 1
10 – 19 % 78
Total 79
page 8
Client EXXON MOBIL INDONESIA Inspection Technologies
Contract Number n/a www.RosenInspection.net
Date March 26, 2010
ROSEN Project No. 8-6200-11486
ROSEN Line Name 30NSANSO
Inspection Type CDP / EGP
Revision Number 0
Geometric anomalies
Number of dents with an ID reduction ≥ 1 % and < 2 % 0
Number of dents with an ID reduction ≥ 2 % and < 6 % 0
Number of dents with an ID reduction ≥ 6 % 0
Number of ovalities ≥ 1 % and < 2 % 0
Number of ovalities ≥ 2 % and < 6 % 0
Number of ovalities ≥ 6 % 0
Others w/o calculation 0
Total 0
Components
Valves 5
Tees/offtakes 22
Others (flange, supports, fixtures, sleeves etc.) 1,812
Total 1,839
page 9
Client EXXON MOBIL INDONESIA Inspection Technologies
Contract Number n/a www.RosenInspection.net
Date March 26, 2010
ROSEN Project No. 8-6200-11486
ROSEN Line Name 30NSANSO
Inspection Type CDP / EGP
Revision Number 0
Rule 1 Anomalies with peak depth greater than or equal to 80% wall loss
Rule 2 Anomalies with ERF greater than or equal to 1
Rule 3 Anomalies with ERF greater than or equal to 0.95 and less than 1.0
Rule 4 Anomalies with peak depth greater than or equal to 20% and less than 80%
Reference information
log distance downstream of the tool launcher [m]
upstream weld log distance in [m]
joint length in [m]
Anomaly information
anomaly identification
anomaly dimension classification
o’clock position [hh:mm]
assigned or calculated wall thickness in [mm]
anomaly length in [mm]
anomaly width in [mm]
max. depth in [%] of actual wall thickness
average depth in [%] of actual wall thickness
surface location [internaI (INT) / non-internal (NON-INT) / not applicable (N/A)]
ERF (Estimated Repair Factor)
comment
location classification (location. class.) of the upstream edge of the anomaly rectangle
− W = on weld (± 0.025)
− C = close to weld (± 0.025 - 0.3 m)
− J = in joint
cluster type
− [X] = clustered
− [–] = single anomaly
cluster ID
Note In case that single corrosion anomalies within a cluster have a different internal / non-
internal distinction (combination of internal and external corrosion at the same location), the
‘CLUSTER’ will be set according to the cluster relevant anomaly.
The weld location indicators are calculated using the coordinates of the upstream edge
of the anomaly rectangle.
For details on anomaly descriptions please refer to the Appendix ‘Terms and
Definitions’.
page 10
Client EXXON MOBIL INDONESIA Inspection Technologies
Contract Number n/a www.RosenInspection.net
Date March 26, 2010
ROSEN Project No. 8-6200-11486
ROSEN Line Name 30NSANSO
Inspection Type CDP / EGP
Revision Number 0
page 11
Client EXXON MOBIL INDONESIA Inspection Technologies
Contract Number n/a www.RosenInspection.net
Date March 26, 2010
ROSEN Project No. 8-6200-11486
ROSEN Line Name 30NSANSO
Inspection Type CDP / EGP
Revision Number 0
The metal loss anomalies are grouped into four (4) categories as follows:
page 12
Client EXXON MOBIL INDONESIA Inspection Technologies
Contract Number n/a www.RosenInspection.net
Date March 26, 2010
ROSEN Project No. 8-6200-11486
ROSEN Line Name 30NSANSO
Inspection Type CDP / EGP
Revision Number 0
2.8 Conclusions
The Metal Loss and Geometry Inspections were successfully completed.
In total, 79 metal loss indications classified as pipe mill anomalies (ANOM-MIAN) with a
calculated wall loss ≥ 10 % have been reported.
In addition, six (6) girth weld anomalies (ANOM-GWAN) have been observed. These
indications may possibly be caused by girth weld anomalies such as lack of penetration,
lack of fusion or minor misalignment, etc. In addition, the accuracy of metal loss anomalies
reported close to the girth weld may be reduced due to the HAZ of the girth welds.
Furthermore, two (2) milling anomalies (ANOM-MILL) have also been observed and are
reported without wall loss calculations.
For further details please refer to section 2.4 ‘Inspection Findings’ and section 10,
‘Inspection Results’.
2.9 Recommendations
As far as can be concluded from this metal loss inspection, further investigation should
be considered for anomalies listed in section 2.5. ‘List of Most Severe Anomalies’.
Whether additional metal loss control measurements are required, could only be
determined by comparison with previous inspections and operational history.
page 13
Client EXXON MOBIL INDONESIA Inspection Technologies
Contract Number n/a www.RosenInspection.net
Date March 26, 2010
ROSEN Project No. 8-6200-11486
ROSEN Line Name 30NSANSO
Inspection Type CDP / EGP
Revision Number 0
3 | ROSOFT
3.1 Introduction
ROSOFT, a client software developed by ROSEN (RTRC), gives comprehensive
information of all the inspection results. It can assist an operator in planning of
maintenance and repair action. The software delivered to the client with the final report,
offers complete access to all database results.
Processor ≥ 2 GHZ, P4
HDD ≥ 80GB
Memory ≥ 1024 MB
Graphic Adapter ≥ 256 MB
Display Resolution ≥ 1024 x 768
DVD-Drive
Note Databases including high amount of anomalies or high-end ROSOFT implementations (e.g.
3D visualization) require significant higher system resources.
page 14
Client EXXON MOBIL INDONESIA Inspection Technologies
Contract Number n/a www.RosenInspection.net
Date March 26, 2010
ROSEN Project No. 8-6200-11486
ROSEN Line Name 30NSANSO
Inspection Type CDP / EGP
Revision Number 0
4 | Pipeline Data
This data is based on information as received from the client prior to the inspection.
page 15
Client EXXON MOBIL INDONESIA Inspection Technologies
Contract Number n/a www.RosenInspection.net
Date March 26, 2010
ROSEN Project No. 8-6200-11486
ROSEN Line Name 30NSANSO
Inspection Type CDP / EGP
Revision Number 0
5 | Field Work
CLP-30-MBD-LG
CLP-30-MBD-LBM
It was concluded that the line had no geometric obstructions preventing the EGP / CDP.
page 16
Client EXXON MOBIL INDONESIA Inspection Technologies
Contract Number n/a www.RosenInspection.net
Date March 26, 2010
ROSEN Project No. 8-6200-11486
ROSEN Line Name 30NSANSO
Inspection Type CDP / EGP
Revision Number 0
Tool and personnel were mobilized on January 15, 2010. Fieldwork was finalized on
January 25, 2010.
For details about data quality please refer to section 6, ‘Data Quality’.
For details about inspection conditions and recorded data please refer to the following data.
Inspection Conditions
Inspection Direction NSO A Launcher Barrel to NSO Plant Receiver
Barrel
Launching Date/Time January 22, 2010 / 09:15 h
Receiving Date/Time January 22, 2010 / 17:55 h
Duration incl. Tool Stops 8 h 40 mins
Average Velocity 3.36 m/s
Propellant gas
Pressure (max.) 5.36 MPa
Temperature (max.) 36.3 °C
Recorded Data
Start of Data Recording - 3.643 m
End of Data Recording 102,068.847 m
Minimum Velocity 2.17 m/s
Maximum Velocity 7.29 m/s
Note To enable a comparison of EGP and CDP data, the EGP distance recorded was adapted to
the CDP distance.
page 17
Client EXXON MOBIL INDONESIA Inspection Technologies
Contract Number n/a www.RosenInspection.net
Date March 26, 2010
ROSEN Project No. 8-6200-11486
ROSEN Line Name 30NSANSO
Inspection Type CDP / EGP
Revision Number 0
Tool and personnel were mobilized on January 15, 2010. Fieldwork was finalized on
January 25, 2010.
For details about data quality please refer to section 6., ‘Data Quality’.
For details about inspection conditions and recorded data please refer to the following data.
Inspection Conditions
Inspection Direction NSO A Launcher Barrel to NSO Plant Receiver
Barrel
Launching Date/Time January 24, 2010 / 13:13 h
Receiving Date/Time January 25, 2010 / 03:00 h
Duration incl. Tool Stops 13 h 47 mins
Average Velocity 2.08 m/s
Propellant gas
Pressure (max.) 5.36 MPa
Temperature E-Unit (max.) 37.8 °C
Recorded Data
Start of Data Recording - 3.643 m
End of Data Recording 102,068.847 m
Minimum Velocity 0.00 m/s (including tool stops)
Maximum Velocity 4.00 m/s
Recorded Rotation minimal
page 18
Client EXXON MOBIL INDONESIA Inspection Technologies
Contract Number n/a www.RosenInspection.net
Date March 26, 2010
ROSEN Project No. 8-6200-11486
ROSEN Line Name 30NSANSO
Inspection Type CDP / EGP
Revision Number 0
6 | Data Quality
The following pages are an overview of the quality of data recorded during the tool
run(s). Data quality is dependent on the specifications given for the tool used. These
specifications are given in section 7, ‘Inspection Specifications’. Furthermore, the
quality can be affected by the type of the pipe (grade, etc.) and the number of sensors
damaged during the run.
Note In case of different type of tools used, the information collected with the CDP tool were used
as master information, relevant e.g. for distance adaptation, definition of installation type
etc..
page 19
Client EXXON MOBIL INDONESIA Inspection Technologies
Contract Number n/a www.RosenInspection.net
Date March 26, 2010
ROSEN Project No. 8-6200-11486
ROSEN Line Name 30NSANSO
Inspection Type CDP / EGP
Revision Number 0
The tool velocity during the run was mainly within the pre-agreed ranges. Generally, in
areas where the velocity is out of range, the ROSEN standard accuracy may not be
achieved. In addition, data quality may be reduced in areas where tool vibrations were
observed.
To enable a comparison of EGP and CDP data, the EGP distance recorded was
adapted to the CDP distance.
6.1.2 CDP
The complete line was inspected in one (1) run.
All measuring channels, both primary and secondary, functioned properly and the data
recorded is of good quality and complete, except for four (4) primary sensor channels
that failed for the entire run, resulting in 0.70 % primary sensor loss.
Over the complete line length, the standard magnetization values of 10 – 30 kA/m were
achieved. In general, areas where the standard magnetization level was not achieved,
the ROSEN standard accuracy may be reduced.
The tool velocity during the run was within the pre-agreed ranges. Generally, in areas
where the velocity is out of range, the ROSEN standard accuracy may not be achieved.
To facilitate future comparisons, the recorded log distance was adapted to the 2005
ROSEN (CDP) inspection log distance.
For further details please refer to section 6.3.2, ‘Velocity CDP’ and section
6.5, ‘Magnetization CDP’.
page 20
Client EXXON MOBIL INDONESIA Inspection Technologies
Contract Number n/a www.RosenInspection.net
Date March 26, 2010
ROSEN Project No. 8-6200-11486
ROSEN Line Name 30NSANSO
Inspection Type CDP / EGP
Revision Number 0
Four (4) primary sensor channels failed for the entire run, resulting in 0.70 % primary
sensor loss.
The rotational tool position is given in degrees and counter clockwise measured in the
downstream direction.
6.3 Velocity
6.3.1 EGP
The EGP velocity during the inspection is constantly recorded. On basis of the velocity
information, the minimum and maximum velocity versus the pipeline length is calculated
in sampling intervals and can be seen on the following velocity graph.
The EGP tool was programmed to operate within the following velocity range:
In all areas where the velocity is out of range the ROSEN standard accuracy might not
be achieved.
6.3.2 CDP
On basis of the CDP velocity information recorded, the minimum and maximum velocity
has been calculated per joint. The velocity graph shows these values versus pipeline
length.
In all areas where the velocity is out of range the ROSEN standard accuracy might not
be achieved.
page 21
Client EXXON MOBIL INDONESIA Inspection Technologies
Contract Number n/a www.RosenInspection.net
Date March 26, 2010
ROSEN Project No. 8-6200-11486
ROSEN Line Name 30NSANSO
Inspection Type CDP / EGP
Revision Number 0
6.4 Temperature
6.4.1 EGP
This plot shows the temperature versus pipeline length during the EGP run.
The temperature probe is positioned inside the EGP electronic unit. It takes approx. 30
minutes before the temperature probe actually measures the temperature of the internal
EGP electronic unit.
6.4.2 CDP
This plot shows the internal tool temperature versus pipeline length during the CDP run,
listed per joint.
The temperature probe is positioned inside the CDP electronic unit. It takes
approximately 30 minutes before the temperature probe actually measures the
temperature of the internal CDP electronic unit.
The minimum and maximum standard values for the magnetization level to keep the
claimed specifications should be between 10 kA/m to 30 kA/m. (see section 7,
‘Inspection Specifications’).
page 22
Client EXXON MOBIL INDONESIA Inspection Technologies
Contract Number n/a www.RosenInspection.net
Date March 26, 2010
ROSEN Project No. 8-6200-11486
ROSEN Line Name 30NSANSO
Inspection Type CDP / EGP
Revision Number 0
7 | Inspection Specifications
page 23
Client EXXON MOBIL INDONESIA Inspection Technologies
Contract Number n/a www.RosenInspection.net
Date March 26, 2010
ROSEN Project No. 8-6200-11486
ROSEN Line Name 30NSANSO
Inspection Type CDP / EGP
Revision Number 0
page 24
Client EXXON MOBIL INDONESIA Inspection Technologies
Contract Number n/a www.RosenInspection.net
Date March 26, 2010
ROSEN Project No. 8-6200-11486
ROSEN Line Name 30NSANSO
Inspection Type CDP / EGP
Revision Number 0
page 25
Client EXXON MOBIL INDONESIA Inspection Technologies
Contract Number n/a www.RosenInspection.net
Date March 26, 2010
ROSEN Project No. 8-6200-11486
ROSEN Line Name 30NSANSO
Inspection Type CDP / EGP
Revision Number 0
8 | Attachments
page 26
Client EXXON MOBIL INDONESIA Inspection Technologies
Contract Number n/a www.RosenInspection.net
Date March 26, 2010
ROSEN Project No. 8-6200-11486
ROSEN Line Name 30NSANSO
Inspection Type CDP / EGP
Revision Number 0
page 27
Client EXXON MOBIL INDONESIA Inspection Technologies
Contract Number n/a www.RosenInspection.net
Date March 26, 2010
ROSEN Project No. 8-6200-11486
ROSEN Line Name 30NSANSO
Inspection Type CDP / EGP
Revision Number 0
page 28
Client EXXON MOBIL INDONESIA Inspection Technologies
Contract Number n/a www.RosenInspection.net
Date March 26, 2010
ROSEN Project No. 8-6200-11486
ROSEN Line Name 30NSANSO
Inspection Type CDP / EGP
Revision Number 0
As part of our ‘Quality Assurance’ system, we would appreciate you completing the
enclosed questionnaire regarding our inspection services. For us it is important that we
stay informed of our customers’ degree of satisfaction. Your valuable answers to our
questionnaire will allow us to improve our inspection services of the pipeline owner.
page 29
Client EXXON MOBIL INDONESIA Inspection Technologies
Contract Number n/a www.RosenInspection.net
Date March 26, 2010
ROSEN Project No. 8-6200-11486
ROSEN Line Name 30NSANSO
Inspection Type CDP / EGP
Revision Number 0
10 | Inspection Results
Listing
Individually Sentenced Anomaly Reports (ISAR’s)
Graphs
Pipe Tally
All distances are expressed in meters [m]. Upstream distances are signed with a minus
(-), downstream distances have no sign. All anomalies are referenced to the
upstream girth weld.
The CDP centre distance of the first valve in the launcher station has been set to
0.001 m, and is used as a reference distance. Please note that the recorded distance
has been adapted to the 2005 inspection log distance.
Any anomaly or pipeline feature that does not qualify for ROSEN Metal Loss
Performance Specifications due to its geometry, location, or run conditions is provided
for informational purposes only.
For further details please refer to section 7.3, ‘Metal Loss Inspection Performance
Specifications’ and Appendix ‘Terms and Definitions’.
page 30
Client EXXON MOBIL INDONESIA Inspection Technologies
Contract Number n/a www.RosenInspection.net
Date March 26, 2010
ROSEN Project No. 8-6200-11486
ROSEN Line Name 30NSANSO
Inspection Type CDP / EGP
Revision Number 0
The ‘List of Anomalies’ contains all anomalies detected and all anomalies classified as
metal loss with a calculated wall loss above the reporting threshold.
In the event of single anomalies in close proximity to one another, interaction rules may
apply and the anomalies were clustered in accordance with specification. The
coordinates of the cluster refer to the start point of the cluster, the depth of the cluster
refers to the max. anomaly depth in the cluster.
Reference information
log distance downstream of the tool launcher [m]
upstream weld log distance in [m]
joint length in [m]
Anomaly information
anomaly identification
anomaly dimension classification
o’clock position [hh:mm]
assigned or calculated wall thickness in [mm]
anomaly length in [mm]
anomaly width in [mm]
max. depth in [%] of actual wall thickness
surface location [internaI (INT) / non-internal (NON-INT) / not applicable (N/A)]
ERF (Estimated Repair Factor)
comment
location classification (location. class.) of the upstream edge of the feature rectangle
− W = on weld (± 0.025 m)
− C = close to weld (± 0.025 m - 0.3 m)
− J = in joint
cluster type
− [X] = clustered
− [–] = single feature
Note In case that single corrosion anomalies within a cluster have a different internal / non-
internal distinction (combination of internal and external corrosion at the same location), the
‘CLUSTER’ will be set according to the cluster relevant anomaly.
The weld location indicators are calculated using the coordinates of the upstream edge
of the anomaly rectangle.
For details on anomaly descriptions please refer to the Appendix ‘Terms and
Definitions’.
page 31
Client EXXON MOBIL INDONESIA Inspection Technologies
Contract Number n/a www.RosenInspection.net
Date March 26, 2010
ROSEN Project No. 8-6200-11486
ROSEN Line Name 30NSANSO
Inspection Type CDP / EGP
Revision Number 0
page 32
Client EXXON MOBIL INDONESIA Inspection Technologies
Contract Number n/a www.RosenInspection.net
Date March 26, 2010
ROSEN Project No. 8-6200-11486
ROSEN Line Name 30NSANSO
Inspection Type CDP / EGP
Revision Number 0
page 33
Client EXXON MOBIL INDONESIA Inspection Technologies
Contract Number n/a www.RosenInspection.net
Date March 26, 2010
ROSEN Project No. 8-6200-11486
ROSEN Line Name 30NSANSO
Inspection Type CDP / EGP
Revision Number 0
The components, which are expected to be easily referenced above ground were used
for reference information.
References:
distance to closest reference component in [m]
reference log distance in [m]
reference type
distance to closest marker in [m]
marker log distance in [m]
marker type / name
comments (if any)
page 34
Client EXXON MOBIL INDONESIA Inspection Technologies
Contract Number n/a www.RosenInspection.net
Date March 26, 2010
ROSEN Project No. 8-6200-11486
ROSEN Line Name 30NSANSO
Inspection Type CDP / EGP
Revision Number 0
page 35
Client EXXON MOBIL INDONESIA Inspection Technologies
Contract Number n/a www.RosenInspection.net
Date March 26, 2010
ROSEN Project No. 8-6200-11486
ROSEN Line Name 30NSANSO
Inspection Type CDP / EGP
Revision Number 0
page 36
Client EXXON MOBIL INDONESIA Inspection Technologies
Contract Number n/a www.RosenInspection.net
Date March 26, 2010
ROSEN Project No. 8-6200-11486
ROSEN Line Name 30NSANSO
Inspection Type CDP / EGP
Revision Number 0
The ERF calculation has been made according to ASME B31G Code.
Following the ASME B31G Code, an ERF calculation has been performed for metal loss
anomalies that have been identified as being caused by corrosion. For all other
anomalies no ERF values have been calculated.
Note No metal loss anomalies have been identified as being caused by corrosion, therefore this
graph is inapplicable.
For more detailed information please refer to Appendix ‘Terms and Definitions’
MAOP
ERF =
TDFP
For values where the TDFP lies below the MAOP, the ERF value is greater than 1.
The following values have been used for calculation as delivered by the client:
MAOP 6.89
× 0.909 = × 0.909 = 0.909
Pdesign 6.89
Note No metal loss anomalies have been identified as being caused by corrosion, therefore this
graph is inapplicable.
page 37
Client EXXON MOBIL INDONESIA Inspection Technologies
Contract Number n/a www.RosenInspection.net
Date March 26, 2010
ROSEN Project No. 8-6200-11486
ROSEN Line Name 30NSANSO
Inspection Type CDP / EGP
Revision Number 0
The following values have been used for calculation, as delivered by the client:
Based on Barlow’s formula and the information provided, the calculated safety factor
below has been utilised to produce this graph.
OD x Pdesign
Design factor =
2 x SMYS x t
1
Safety factor =
design factor
The above values can be changed for customised calculations within ROSOFT.
Note No metal loss anomalies have been identified as being caused by corrosion, therefore this
graph is inapplicable.
page 38
Client EXXON MOBIL INDONESIA Inspection Technologies
Contract Number n/a www.RosenInspection.net
Date March 26, 2010
ROSEN Project No. 8-6200-11486
ROSEN Line Name 30NSANSO
Inspection Type CDP / EGP
Revision Number 0
Note No metal loss anomalies have been detected as non-internal, therefore these graphs are
inapplicable.
page 39
Client EXXON MOBIL INDONESIA Inspection Technologies
Contract Number n/a www.RosenInspection.net
Date March 26, 2010
ROSEN Project No. 8-6200-11486
ROSEN Line Name 30NSANSO
Inspection Type CDP / EGP
Revision Number 0
Note An ERF value has been calculated for all anomalies caused by corrosion calculated with
wall loss ≥ 10% and < 80%.
page 40
Client EXXON MOBIL INDONESIA Inspection Technologies
Contract Number n/a www.RosenInspection.net
Date March 26, 2010
ROSEN Project No. 8-6200-11486
ROSEN Line Name 30NSANSO
Inspection Type CDP / EGP
Revision Number 0
Note No metal loss anomalies have been detected with depth ≥ 40 % or ERF ≥ 0.8, therefore
these graphs are inapplicable.
page 41
Client EXXON MOBIL INDONESIA Inspection Technologies
Contract Number n/a www.RosenInspection.net
Date March 26, 2010
ROSEN Project No. 8-6200-11486
ROSEN Line Name 30NSANSO
Inspection Type CDP / EGP
Revision Number 0
• Data Plots
One (1) ISAR has been prepared following the ‘List of Most Severe Anomalies’,
described under section 2.5, sorted by severity then log distance.
Data Plot
The data charts can be read as follows:
Left
• Distance in [mm] starting at 12 o’clock position looking downstream and measured
counter clockwise
• O’clock position looking downstream
Bottom
• Distance measurement [m]
Additional Information
In case of clustered anomalies, the upstream edge of the anomaly rectangle is given as
(start) log distance. Please find below following additional information:
Anomaly No. 1
Log distance 39,058.282 m
O‘clock position 10:28 h
Type / Classification pipe mill anomaly
Length / Width 18 mm x 16 mm
Maximum Calculated WL 27 %
Calculated ERF n/a
Internal / non-internal internal
Comments Possible longitudinal weld anomaly.
page 42
Client EXXON MOBIL INDONESIA Inspection Technologies
Contract Number n/a www.RosenInspection.net
Date March 26, 2010
ROSEN Project No. 8-6200-11486
ROSEN Line Name 30NSANSO
Inspection Type CDP / EGP
Revision Number 0