Vous êtes sur la page 1sur 4

Location: Greenland Subdivision, Marikina City

Distance from Active Fault Line (West Valley Fault Line): 4km

Total Weight Computation:

Column Area: 400 mm x 400 mm


Slab Thickness: 300mm
Beam: 300x500 mm
Exterior Wall Thickness: 180 mm
Interior Wall Thickness: 150 mm
*Other Superimposed Dead load:
CONCRETE TOPPINGS AT ROOF = 0.075m
CONCRETE TOPPINGS AT TYPICAL FLR. = 0.05m
* Assumed 1.2 meter high parapet RC wall along the perimeter of the roof level.

SECOND FLOOR:
COLUMNS = (24 kN/m3)(0.4m x 0.4m)(2.4m)(12) = 0.9216 kPa
10 m x 12 m

BEAMS = (0.3m x 0.4m)(24 kN/m3)(87.4) = 2.0976 kPa


10m x 12m

SLAB = (24 kN/m3)( 10m x 12m)(0.3m) = 7.2 kPa


10m x 12m

EXTERIOR WALLS
= (3.88 kPa)( 10m (2)+ 12m (2)-7m)(2.4m) =2.8712 kPa
10m x 12m

INTERIOR WALLS = (3.88 kPa)(50.8)(2.4m) = 3.9421 kPa


10m x 12m

TOPPING WEIGHT = (0.05m)(24kN/m3) = 1.2 kPa

TOTAL = 18.2325 kPa


TOTAL= 18.2325 kPa (10m x 12m) = 2187.9 kN
THIRD FLOOR:

COLUMNS = (24 kN/m3)(0.4m x 0.4m)(2.4m)(11) = 0.8448 kPa


(10m x 12m)

BEAMS = (0.3m x 0.5m)(24 kN/m3)( 87.4) = 2.622 kPa


(10m x 12m)

SLAB = (24 kN/m3)(10m x 12m)(0.3m) = 7.2 kPa


10m x 12m

EXTERIOR WALLS = (3.88 kPa)(10m+12m(2)+7-12m)(2.4m) = 2.2504 kPa


10m x 12m

INTERIOR WALLS = (3.88 kPa)(24m)(2.4m) = 1.8624 kPa


10m x 12m

TOPPING WEIGHT = (0.05m)(24kN/m3) = 1.2 kPa

TOTAL = 15.9796 kPa


TOTAL = 15.9796 kPa (10m x 12m) = 1917.552 kN

ROOF WEIGHT:

SLAB WEIGHT = 0.15m x 24kN/m3 = 3.60 kPa

TOPPING WEIGHT = 0.075m x 24kN/m3 = 1.80 kPa

PARAPET WEIGHT = (0.15m)(1.2m)(40m)(24kN/m3) = 1.44 kPa


10m x 12m

BEAMS = (0.3m x 0.5m)(24 kN/m3)( 87.4m) = 2.622 kPa


(10m x 12m)

COLUMNS = (24 kN/m3)(0.4m x 0.4m)(2.4m/2)(11) = 0.8448 kPa


(10m x 12m)

TOTAL = 10.3068 kPa


TOTAL = 10.3068 kPa (10m x 12m) = 1236.816 kN

TOTAL WEIGHT = T1+T2+T3 = 2187.9 kN + 1917.552 kN+ 1236.816 kN


TOTAL WEIGHT = 5342.268 kN
EARTHQUAKE LOAD COMPUTATION
PROPERTIES:
Total Height of Structure = 9.5m
Special Reinforced Concrete Moment Frame, R = 8.5
Importance Factor, I = 1.0 (Residential House)

Near Source Factor, Na = 1.2

Near Source Factor, Nv = 1.6

Ct = 0.0731

Soil Type = Sd

Seismic Zone, Z = 0.4

Seismic Coefficient for Na, Ca = 0.44Na = 0.44*1.2 = 0.528

Seismic Coefficient for Nv, Cv = 0.64Na = 0.64*1.6 = 1.024

Total Weight = 3623.3 kN

FUNDAMENTAL PERIOD OF VIBRATION:

T = Ct (hn)3/4
T = (0.0731)(9.5)3/4

T = 0.396 sec

Additional Concentrated Load at the Top of the Structure (Ft):


Ft = 0; since T ≤ 0.7 sec.

BASE SHEAR COMPUTATION:

V = CVIW = 1.024(1)(3623.3kN) = 1102.275 kN


RT 8.5(0.396)

BASE SHEAR MUST NOT EXCEED:

V = 2.5CaIW = 2.5(0.528)(1)(3623.3kN) = 562.677kN < 1102.275kN Not ok! Therefore my


R 8.5 new BASE SHEAR is
562.677kN
Base Shear must not be less than:
V = 0.11𝐶𝑎𝐼𝑊 = 0.11(0.528)(1)(3623.3kN) = 210.441 kN < 1102.275kN ok!

For Zone 4, BASE SHEAR SHALL NOT BE LESS THAN:

V = 0.8ZNVIW = 0.8(0.4)(1.6)(1)(3623.3kN) = 218.251 kN < 1102.275kN ok!


R 8.5

DESIGN SEISMIC FORCE AT EACH STORY LEVEL

Story Level hx (meters) Wx (kN) hxWx (kN*m) Fx (kN)

Roof 9.5 1236.816 kN 11749.752 240.9670

Third Floor 5.1 1917.552 kN 9779.5152 200.5609

Second Floor 2.7 2187.9 kN 5907.33 121.1491

27436.5972 562.677

SECOND FLOOR:

FX = (V- Ft)WXHX = (562.677kN - 0)(11749.752kN*m) = 240.9670 kN


ϵWXhX 27436.5972 kN*m

THIRD FLOOR:

FX = (V- Ft)WXHX = (562.677kN - 0)(9779.5152kN*m) = 200.5609 kN


ϵWXhX 27436.5972 kN*m

ROOF:

FX = (V- Ft)WXHX = (562.677kN - 0)(5907.33kN*m) = 121.1491 kN


ϵWXhX 27436.5972 kN*m